1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Siemens Text panel

16 272 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Nội dung

tài liệu Siemens

CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 TRANG 1 Text Panels - SIMATIC TD17 Overview • Text display for displaying and storing messages • For use directly at the machine as well as in a control room • LED-backlit LCD: - 4-line, 20 characters/line; character height 11 mm or - 8-line, 40 characters/line; character height 6 mm. • 7 system keys Benefits • Clearly contrasting display, easier to read • Large keys for enhanced operating reliability • Fast variable updating • Easy handling and configuration • Maintenance-free thanks to electronic fuse Area of application The TD17 Text Displays can be used in all applications in which monitoring of machines and installations is required on site – whether in production automation, process automation or building service automation. They are in use in an extensive range of sectors and applications. The TD17 is simply for display purposes and does not support intervention in the process. CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 TRANG 2 Design The TD17 Text Display is based on OP7/OP17 technology. • LED-backlit LCD: - 4-line, 20 characters/line; character height 11 mm or - 8-line, 40 characters/line; character height 6 mm. • 7 system keys • Metal-reinforced plastic housing with membrane front • The front is resistant to various oils, greases and standard detergents • 47 mm mounting depth • Electronic fuse Functions Message functions • Integration of up to 8 process values per alarm • Operating and system message buffer • Scrolling in messages • Specification of message priorities • Date and time in messages • Mixed operation using upper and lower case letters Other functions • Loadable firmware • Contrast adjustment • User-friendly native driver for various non-Siemens PLCs • Backup/restore function for firmware and user data (ProSave) • PLC orders to trigger PLC-controlled actions • Language selection with 3 online languages Configuration Configuring is performed using the configuration software SIMATIC ProTool/Lite, SIMATIC ProTool or SIMATIC ProTool/Pro Configuration (see configuration or visualization software) Integration The TD17 can be connected to: • SIMATIC S7-200/-300/-400 • SIMATIC WinAC Software/Slot PLC • SIMATIC S5 • SIMATIC 505 • SINUMERIK • Third-party PLCs, including - Allen Bradley - Mitsubishi - Telemecanique - Modicon - Omron - GE Fanuc CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 TRANG 3 Note: For further information, see "System interfaces". Technical Specifications Type TD17 Display LCD • Line display - Line number (max.) 8 - Characters per line (max.) 40 • Character height (mm) 6 or 11 • Colors Monochrome • MTBF of backlighting at 25 °C Approx. 200,000 hours Control elements Membrane keyboard • System keys 7 system keys Operating system RMOS Memory • Type Flash / RAM • Usable memory for user data 128 KB Interfaces 1 x TTY, 1 x RS232, 1 x RS422, 1 x RS485 Interface with PLC S5, S7-200, S7-300/400, 505, SINUMERIK, Mitsubishi (FX), Telemecanique (ADJUST), Modicon (Modbus), other non-Siemens PLCs Supply voltage 24 V DC • Rated voltage 24 V • Permitted range +18 to +30 V DC • Current consumption, typ. 0.34 A Backup battery Optional, 3.6 V Clock Hardware clock, with back-up Degree of protection • Front IP 65 (installed) • Rear IP 20 Certification GL, FM, UL, CSA, CE Dimensions • Front (W x H in mm) 240 x 98 • Mounting cutout/depth W x H x D (mm) 231 x 89 x 47 Weight (kg) 0.9 Ambient conditions • Mounting position - max. permissible angle of inclination without forced ventilation 35° • Temperature - Operation (vertical installation) 0 °C to +50 °C - Operation (max. inclination) 0 °C to +35 °C - Transport, storage -25 °C to +70 °C • Relative humidity, max. 95% CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 TRANG 4 Functionality 1) Message system • Status messages 999 • System messages Yes • Message length (lines x characters) 4 x 20 or 8 x 40 • Number of process values per message 8 • Message buffer Battery-backed cyclic buffer, 256 entries each Password protection (levels) 10 Help text Yes Online languages 3 • Project languages Danish, German, traditional Chinese, simplified Chinese, English, Finnish, French, Italian, Dutch, Norwegian, Polish, Portuguese, Spanish, Czech, Turkish, Hungarian Configuration tool ProTool/Lite Version 2.51 upwards, executable under Windows 98/SE/ME/NT/2000 (must be ordered separately) • Configuration transfer Serial 1) The specifications are maximum values. The total number of configurable elements is limited by the size of the user memory. Further Information Additional information is available in the Internet under: http://www.siemens.com/panels Text Panels - SIMATIC OP3 CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 TRANG 5 Overview • Operator panel for operator control and monitoring of small machines and plants • Specifically for SIMATIC S7 • Can also be used as a hand-held device • LED-backlit LCD: 2-line, 20 characters/line; character height 5 mm. • 18 system keys, of which 5 are freely configurable function keys Benefits • Easy handling and configuration • Small and compact • Extensive functionality, e.g.: - Linear conversion - Variable limit values - PG function STATUS/CONTROL of variables Area of application The OP3 Operator Panels can be used in all small-scale applications in which operator control and monitoring of machines and installations is required on site – whether in production automation, process automation or building service automation. They are in use in an extensive range of sectors and applications. Design • LED-backlit LCD, 2-line, 20 characters/line; character height 5 mm. • 18 system keys, of which 5 are freely configurable function keys • Plastic housing with membrane front • The front is resistant to various oils, greases and standard detergents • 25 mm mounting depth Functions Operator functions • Alphanumeric setpoint input using system keys • Softkeys (function of the keys can be configured specific to the display) Message functions • Process value indication • Management and editing of operating messages • Date and time in messages • Definition of message priorities Other functions • Limit value check for inputs CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 TRANG 6 • STATUS VAR/CONTROL VAR in conjunction with SIMATIC S7 • Password protection • Language selection with 3 online languages • Contrast adjustment • Linear conversion • Variable limit values Configuration Configuring is performed using the configuration software SIMATIC ProTool/Lite, SIMATIC ProTool or SIMATIC ProTool/Pro Configuration (see configuration or visualization software) Integration Fast and easy connection to SIMATIC S7-200/-300/-400 PLCs is possible via the integrated interface. An additional master (e.g. PG or OP) in the PPI network is permissible. Note: For further information, see "System interfaces". Technical Specifications Type OP3 Display LCD • Line display - Characters per line (max.) 20 - Number of lines (max.) 2 • Character height (mm) 5 • Colors Monochrome • MTBF backlighting (at 25 °C) Approx. 200,000 hours Control elements Membrane keyboard • Function keys, programmable 5 function keys • System keys 18 system keys • Numeric/alphanumeric input Yes/yes Operating system RMOS Memory • Type Flash / RAM • Usable memory for user data 128 KB Interfaces 1 x RS 232, 1 x RS 485 Connection to PLC S7-200, S7-300/400 Supply voltage 24 V DC • Rated voltage 24 V • Permitted range +18 to +30 V DC • Current input, typ. 0.07 A Clock Software clock Degree of protection • Front IP 65 (built-in) CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 TRANG 7 • Rear IP 20 Certification GL, FM, UL, CSA, CE Dimensions • Front W x H (mm) 148 x 76 • Mounting cutout/depth W x H x D (mm) 138 x 68 x 25 Weight (kg) 0.25 Ambient conditions • Mounting position - Max. permissible angle of inclination without forced ventilation 180° • Temperature - Operation (vertical mounting) 0 °C to +60 °C - Operation (max. angle of inclination) 0 °C to +60 °C - Transport, storage -20 °C to +60 °C • Relative humidity, max. 85% Functionality 1) Message system • Operating messages 499 • Fault messages No • System messages Yes • Message length (lines x characters) 2 x 20 • Number of process values per message 8 • Message buffer No Process diagrams 40 • Entries per diagram 20 • Graphics objects Character graphics Variables 1,024 Password protection (levels) 10 Online languages 3 • Project languages English, German, French, Italian and Spanish PG functions (STATUS/CONTROL) Yes for S7 Configuration tool ProTool/Lite Version 2.51 upwards, executable under Windows 98/SE/ME/NT/2000 (must be ordered separately) • Transfer of the configuration Serial / MPI 1) The specifications are maximum values. The total number of configurable elements is limited by the size of the user memory. Further Information Additional information is available in the Internet under: http://www.siemens.com/panels CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 TRANG 8 Text Panels - SIMATIC OP7 Overview • Compact, multi-functional operator panel for operator control and monitoring of machines and plants • LED-backlit LCD: 4-line, 20 characters/line; character height 8 mm • 22 system keys, 8 freely-configurable and freely-inscribable function keys (4 with LEDs) Benefits • Clearly contrasting display, easier to read • Large keys for enhanced operating reliability • Fast variable updating • Extensive functionality for efficient HMI – from receipe management through linear conversion as far as the backing up and restoring of firmware and user data • Easy handling and configuration • Maintenance-free thanks to electronic fuse Area of application The OP7 Operator Panels can be used in all applications in which operator control and monitoring of machines and installations is required on site – whether in production automation, process automation or building service automation. They are in use in an extensive range of sectors and applications. Design • LED-backlit LCD, 4-line, 20 characters/line; character height 8 mm CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 TRANG 9 • 22 system keys, 8 freely-configurable and freely-inscribable function keys (4 with LEDs) • Plastic housing with membrane front • The front is resistant to various oils, greases and standard detergents • 38.5 mm mounting depth • Electronic fuse • Interfaces: - OP7/PP: RS 232/TTY, RS 485/422 - OP7/DP: RS 232, RS 485/422, PPI/MPI/PROFIBUS DP up to 1.5 Mbit/s - OP7/DP-12: RS 232/TTY, RS 485/422, PPI/MPI/PROFIBUS DP up to 12 Mbit/s Functions Operator functions • Alphanumeric setpoint input using system keys • Softkeys (function of the keys can be configured specific to the display) • Insertion strips for all softkeys and function keys • Dual softkey rows can be configured • Function keys with LEDs Message functions • Process value indication • Management and editing of operating and fault messages • Date and time in messages • Definition of message priorities • Differentiation between first and last value messages • Help text on messages, diagrams, etc. Other functions • Limit value check for inputs • STATUS VAR/CONTROL VAR in conjunction with SIMATIC S5 and S7 • Password protection • Language selection with 3 online languages • Selection from 17 languages, including system messages (also with Cyrillic character set) • Contrast adjustment • Automation equipment orders to trigger automation equipment-controlled actions • Recipe management • DP direct keys for fast and deterministic operator actions • Linear conversion • Native drivers for third-party PLCs • PROFIBUS DP up to 12 Mbit/s • Variable limit values • Integrated printer port Service concept • Backup/restoring of configuration, firmware and recipe data records • Downloadable firmware CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 TRANG 10 Configuration Configuring is performed using the configuration software SIMATIC ProTool/Lite, SIMATIC ProTool or SIMATIC ProTool/Pro Configuration (see configuration or visualization software) Integration The OP7 can be connected to: • SIMATIC S7-200/-300/-400 • SIMATIC WinAC Software/Slot PLC • SIMATIC S5 • SIMATIC 505 • SINUMERIK • Third-party PLCs, e.g. - Allen Bradley - Mitsubishi - Telemecanique - Modicon - Omron - GE Fanuc Note: For further information see "System interfaces" Technical Specifications Type OP7 Display LCD • Line display - Characters per line (max.) 20 - Number of lines (max.) 4 • Character height (mm) 8 • Colors Monochrome • MTBF backlighting (at 25 °C) Approx. 100,000 hours Control elements Membrane keyboard • Function keys, programmable 8 function keys, 4 with LEDs • System keys 22 system keys • Numeric/alphanumeric input Yes/yes Operating system RMOS Memory • Type Flash / RAM • Usable memory for user data 128 KB Interfaces 1 x TTY (not for OP7-DP), 1 x RS232, 1 x RS485, 1 x RS422 Printer Yes Connection to PLC S5, S7-200, S7-300/400, 505, SINUMERIK, Mitsubishi (FX), Telemecanique (ADJUST) Modicon (Modbus), other non-Siemens PLCs Supply voltage 24 V DC • Rated voltage 24 V [...]... number of configurable elements is limited by the size of the user memory Further Information Additional information is available in the Internet under: http://www .siemens. com/panels Text Panels - SIMATIC OP17 Overview • High-performance operator panel for easy operator control and monitoring of machines and plants • LED-backlit LCD: - 4-line, 20 characters/line; character height 11 mm or - 8-line, 40 characters/line;... specifications are maximum values The total number of configurable elements is limited by the size of the user memory Further Information Additional information is available in the Internet under: http://www .siemens. com/panels TRANG 16 ... linear conversion as far as the backing up and restoring of firmware and user data • Easy handling and configuration • Maintenance-free thanks to electronic fuse Area of application The OP17 Operator Panels can be used in all applications in which operator control and monitoring of machines and installations is required locally – whether in production automation, process automation or building service... 13 CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 • Date and time in messages • Definition of message priorities • Differentiation between first and last value messages • Help text on messages, diagrams, etc • Mixed operation using upper and lower case letters Other functions • Limit value check for inputs • STATUS VAR/CONTROL VAR in conjunction with SIMATIC S5 and S7 • Password... for OP17-DP), 2 x RS232, 1 x RS422, 1 x RS485 (not for OP17-DP) Printer Yes Connection to PLC S5, S7-200, S7-300/400, 505, SINUMERIK, Mitsubishi (FX), Telemecanique (ADJUST) Modicon (Modbus), other non -Siemens PLCs Supply voltage 24 V DC • Rated voltage 24 V • Permitted range +18 to +30 V DC • Current input, typ 0.39 A Backup battery Optional, 3.6 V Clock Hardware clock, with back-up Degree of protection... displays, etc Online languages 3 • Project languages Czech, Danish, Dutch, German, English, Finnish, French, Greek, Hungarian, Italian, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, Turkish Help text Yes PG functions (STATUS/CONTROL) For SIMATIC S5/S7 Timer Yes Configuration tool ProTool/Lite Version 2.51 upwards, executable under Windows 98/SE/ME/NT/2000 (must be ordered separately) • Transfer... • Entries per diagram 99 • Graphics objects Character graphics Variables 2048 Password protection (levels) 10 Printer functions Messages, displays, recipes Online languages 3 • Project languages Help text Czech, Danish, Dutch, German, English, Finnish, French, Greek, Hungarian, Italian, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, Turkish Yes TRANG 11 CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN . under: http://www.siemens.com/panels Text Panels - SIMATIC OP3 CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 TRANG 5 Overview • Operator panel for operator control and. under: http://www.siemens.com/panels CÔNG TY CÔNG NGHỆ TỰ ĐỘNG TÂN TIẾN TEL : (84-8)9973944 MB : 0918730423 TRANG 8 Text Panels - SIMATIC OP7 Overview • Compact, multi-functional operator panel for operator. information is available in the Internet under: http://www.siemens.com/panels Text Panels - SIMATIC OP17 Overview • High-performance operator panel for easy operator control and monitoring of machines and

Ngày đăng: 14/05/2014, 22:01

Xem thêm

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN