CEI IEC NORME INTERNATIONALE 127-3 INTERNATIONAL STANDARD Deuxième édition Second edition 1988 Amendement Amendment 1991-11 Coupe-circuit miniatures Troisième partie: Eléments de remplacement subminiatures Amendment Miniature fuses Part 3: Sub-miniature fuse-links Les feuilles de cet amendement sont insérer dans la Publication 127-3 (1988) The sheets contained in this amendment are to be inserted in Publication 127-3 (1988) © CEI 1991 Droits de reproduction réservés — Copyright — all rights reserved Bureau Central de la Commission Electrotechnique Internationale 3, rue de Varembé Genève, Suisse IEC• Commission Electrotechnique Internationale international Electrotechnical Commission MemcayHapoa+aa 3nearporexrMVecaaa KoMKccx+a • CODE PRIX PRICE CODE Pour Nix, voir catalogue en vigueur For price, see current catalogue LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Amendement LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU INSTRUCTIONS POUR L'INSERTION DES NOUVELLES PAGES ET FEUILLES DANS LA PUBLICATION 127-3 (1988) INSTRUCTIONS FOR THE INSERTION OF NEW PAGES AND SHEETS IN PUBLICATION 127-3 (1988) Retirer les pages 20 et insérer les nouvelles pages 22 Remove pages to 20 and insert new pages to 22 Retirer les feuilles de normes particulières et insérer les nouvelles feuilles de nonnes particulières Remove standard sheets to and insert new standard sheets to LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU CEI I EC NORME INTERNATIONALE 127-3 INTERNATIONAL STANDARD Deuxième édition Second edition 1988 Modifiée selon l'amendement (1991) Amended in accordance with Amendment (1991) Troisième partie: Eléments de remplacement subminiatures Miniature fuses Part 3: Sub-miniature fuse-links © CEI 1991 Droits de reproduction réservés — Copyright — all rights reserved Aucune partie de cette publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de l'éditeur No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission In writing from the publisher Bureau Central de la Commissio n Electrotechnique Inte rn ationale 3, rue de Varembé Genève, Suisse IEC ^ Commission Electrotechnique Internationale International Electrotechnical Commission Meat,4ynapopitaa 3nelcrporexHwlecisaa KoMHCCwa • LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Coupe-circuit miniatures Publication 127-3 de la CEI IEC Publication 127-3 (Deuxième édition - 1988) (Second edition - 1988) Amendement (1991) Amendment (1991) Coupe-circuit miniatures Miniature fuses Troisième partie: Eléments de remplacement subminiatures Part 3: Sub-miniature fuse-links CORRIGENDUM In Standard Sheet 2, page 1, top of page, replace the existing diagram by the new diagram below NOTE - Optional insulating sleeve 1EC 956/94 Dimensions en millimètres Octobre 1994 Dimensions in millimetres October 1994 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Dans la Feuille de norme 2, page 1, remplacer le schéma existant au haut de la page par le nouveau schéma ci-dessous Publication 127-3 de la CEI IEC Publication 127-3 Amendement – 1991 Amendment – 1991 Coupe-circuit miniatures Miniatures fuses Troisième partie: Eléments de remplacement subminiatures Part 3: Subminiatures fuse-links CORRIGENDUM Page 13 9.4.3 Méthode d’essai B 9.4.3 Test method B Remplacer la page 14 le texte existant du point c) par le nouveau texte suivant: Replace on page 15 the existing text of item c) by the following new text: La chute de tension mesurée au point b) de 9.4.3 ne doit pas avoir augmenté de plus de 10 % de la valeur mesurée avant l’essai et elle ne doit pas dépasser la valeur maximale permise dans la feuille de norme particulière The voltage drop measured in item b) of 9.4.3 shall not have increased by more than 10 % of the value measured before the test and shall not exceed the maximum allowed value in the relevant standard sheet Juin 1996 June 1996 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Page 12 – – 127-3 amend ©CEI SOMMAIRE Pages PRÉAMBULE PRÉFACE INTRODUCTION SECTION UN – PRESCRIPTIONS SUPPLÉMENTAIRES ET ÉQUIPEMENTS D'ESSAI Articles Domaine d'application Objet Définitions Prescriptions générales Valeurs assignées Marquage Généralités sur les essais Dimensions et construction 10 Prescriptions d'ordre électrique 12 8 TABLEAU 16 TABLEAU 18 FIGURES 20 SECTION DEUX – FEUILLES DE NORMES PARTICULIÈRES Feuille de norme 1– Eléments de remplacement subminiatures Fusion rapide, faible pouvoir de coupure Feuille de norme – Eléments de remplacement subminiatures Fusion rapide, faible pouvoir de coupure Feuille de nonne – Eléments de remplacement subminiatures Fusion rapide, faible pouvoir de coupure Feuille de norme – Eléments de remplacement subminiatures Fusion temporisée, faible pouvoir de coupure LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 127-3 Amend © IEC —3— CONTENTS Page FOREWORD PREFACE INTRODUCTION SECTION ONE — ADDITIONAL REQUIREMENTS AND TEST EQUIPMENT Clause Scope Object Definitions General requirements Standard ratings Marking General notes on tests Dimensions and construction 11 Electrical requirements 13 9 9 TABLE 17 TABLE 19 FIGURES 20 SECTION TWO — STANDARD SHEETS Standard Sheet 1— Sub-miniature fuse-links Quick-acting, low breaking capacity Standard Sheet — Sub-miniature fuse-links Quick-acting, low breaking capacity Standard Sheet — Sub-miniature fuse-links Quick-acting, low breaking capacity Standard Sheet — Sub-miniature fuse-links Time lag, low breaking capacity LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU -4– 127-3 amend © CEI COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE COUPE-CIRCUIT MINIATURES Troisième partie: Eléments de remplacement subminiatures PRÉAMBULE 2) Ces décisions constituent des recommandations internationales et sont agréées comme telles par les Comités nationaux 3) Dans le but d'encourager l'unification internationale, la CEI exprime le voeu que tous les Comités nationaux adoptent dans leurs règles nationales le texte de la recommandation de la CEI, dans la mesure où les conditions nationales le permettent Toute divergence entre la recommandation de la CEI et la Règle nationale correspondante doit, dans la mesure du possible, être indiquée en termes clairs dans cette dernière PRÉFACE La présente norme a été établie par le Sous-Comité 32C: Coupe-circuit fusibles miniatures, du Comité d'Études n° 32 de la CEI: Coupe-circuit fusibles Le texte de cette norme est issu des documents suivants: Amendement Règle des Six Mois/DIS Rapport de vote Procédure des Deux Mois Rappo rt de vote 32C(BC)49 32C(BC)58 – – 32C(BC)61 32C(BC)63 32C(BC)64 32C(BC)65 Les rapports de vote indiqués dans le tableau ci-dessus donnent toute information sur le vote ayant abouti l'approbation de cette norme Les publications suivantes de la CEI sont citées dans la présente norme: Publications n g 68-2-20 (1979): Essais fondamentaux climatiques et de robustesse mécanique, Deuxième partie: Essais – Essai T: Soudure 68-2-21 (1983): 695: Essai U: Robustesse des sorties et des dispositifs de fixation Essais relatifs aux risques du feu LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 1) Les décisions ou accords officiels de la CEI en ce qui concerne les questions techniques, préparés par des Comités d'Etudes où sont représentés tous les Comités nationaux s'intéressant ces questions, expriment dans la plus grande mesure possible un accord international sur les sujets examinés 127-3 Amend © IEC Standard Sheet Sub-miniature fuse-links Quick-acting, low breaking capacity Page Marking Sub-miniature fuse-links shall be marked with: a) rated current b) rated voltage c) manufacturer's name or trade mark Pre-arcing time, current characteristic The pre-arcing time shall be within the following limits: In 2,75 In I 10 In minimum maximum maximum maximum maximum 4h 5s 300 ms 30 ms ms mA to A inclusive Breaking capacity Rated breaking capacity: 50 A, tested with a.c and d.c using the circuit given in Figure for the breaking capacity test Endurance test 100 h minimum at a continuous current of 0,8 times the rated current, according to test method B of subclause 9.4.3 Sub-miniature fuse-link contact test The contact leads shall be evaluated in accordance with subclause 8.3 for : a) tensile b) thrust c) bending (applicable only if the length of the terminations is over mm) Sub-miniature fuse-link temperature-rise test The initial current according to subclause 9.7 shall be In Notes I.— For design information relative to minimum spacing between conductive tracks, refer to the second paragraph of subclause 8.4 2.— The maximum operating ambient temperature is +85 °C When the sub-miniature fuse-link is operating under these conditions the current load should be reduced to 0,9 n LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Rated current In 127-3 amend © CEI Eléments de remplacement subminiatures Fusion rapide, faible pouvoir de coupure Feuille de norme Page Dimensions en millimètres 40 max 10 max 40 max o o (1 n• e CEI 880191 Note.— Gaine isolante facultative Sorties a) La sortie doit passer travers un trou de mm et doit avoir une section minimale assignée de 0,150 mm2 b) La forme de la section est laissée au choix Courant Tension assigné assignée * maximale V 50 mA 63 mA 80 mA 100 mA 125 mA 160 mA 200 mA 250 mA 315 mA 400 mA 500 mA 630 mA 800 mA 1A 1,25 A 1,6 A 2A 2,5 A 3,15 A 4A 5A Chute de tension 125 mV 250 230 200 1750 500 1500 1500 000 1000 1000 1000 500 275 275 275 275 250 250 250 225 225 Puiss ance maximale dissipée mW** 123 154 194 193 206 264 330 275 347 440 550 347 242 303 378 484 550 688 866 990 1238 * Les valeurs intermédiaires doivent être choisies dans la série R 20 ou R 40 ** Mesurée au bout de h sous In LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU ^ ^ Li 127-3 amend © CEI Feuille de norme Eléments de remplacement subminiatures Fusion rapide, faible pouvoir de coupure Page Marquage Les éléments de remplacement subminiatures doivent porter les indications ci-après: a) courant assigné b) nom du fabricant ou marque de fabrique ô,1 mm Note.— En cas d'utilisation de bandes de couleurs, les valeurs pour d et s doivent être de 0,4 Caractéristique temps/ courant de préarc La durée de préarc doit être comprise entre les limites suivantes: 50 mA A inclus In 1n 2,751n 1n 10 I minimal maximal maximal maximal maximal 4h 5s 300 ms 30 ms ms Pouvoir de coupure Pouvoir de coupure assigné: 50 A, essayé en courant alternatif et en courant continu, avec les circuits représentés la figure pour l'essai du pouvoir de coupure Essai d'endurance Courant continu égal 0,8 fois le courant assigné pendant 100 h au minimum, suivant la méthode d'essai B du paragraphe 9.4.3 Essai des sorties de l'élément de remplacement subminiature Les sorties doivent être évaluées suivant le paragraphe 8.3 en ce qui concerne: a) la traction b) le pliage Essai d' échauffement de r élément de remplacement subminiature Le courant initial suivant le paragraphe 9.7 doit être In Note.— La température ambiante maximale de fonctionnement est de +85 °C Lorsque l'élément de remplacement subminiature fonctionne dans ces conditions, l'intensité du courant est normalement réduite 0,9 In LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Courant assigné 127-3 Amend © IEC Standard Sheet Sub-miniature fuse-links Quick-acting, low breaking capacity Page Dimensions in millimetres max 40 max 40 max ^ LI U n IEC 880/91 Note.— Optional insulating sleeve Terminations a) The termination must go through a mm hole and have a rated minimum cross-sectional area of 0,150 mm2 b) The cross-sectional shape of the termination is optional Rated current * Rated voltage V 50 mA 63 mA 80 mA 100 mA 125 mA 160 mA 200 mA 250 mA 315 mA 400 mA 500 mA 630 mA 800 mA 1A 1,25 A 1,6 A 2A 2,5 A 3,15 A 4A 5A 125 Maximum voltage drop mV 250 230 200 1750 1500 1500 1500 1000 1000 1000 1000 500 275 275 275 275 250 250 250 225 225 Maximum sustained dissipation mW** 123 154 194 193 206 264 330 275 347 440 550 347 242 303 378 484 550 688 866 990 1238 * Intermediate values shall be chosen from the R 20 or R 40 series ** Measured after h at In LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU ^ 127-3 Amend © IEC Standard Sheet Sub-miniature fuse-links Quick-acting, low breaking capacity Page Marking Sub-miniature fuse-links shall be marked with: a) rated current b) manufacturer's name or trade mark , 1434,1 mm Note.— Where colour b ands are used, the values for d and s shall be 04 Pre-arcing time/ current characteristic The pre-arcing time shall be within the following limits: 50 mA to A inclusive 2n 2,75 In 10 n minimum maximum maximum maximum maximum 4h 5s 300 ms 30 ms ms Breaking capacity Rated breaking capacity: 50 A, tested with a.c and d.c using the circuit given in Figure for the breaking capacity test Endurance test 100 h minimum at a continuous current of 0,8 times the rated current, according to test method B of subclause 9.4.3 Sub-miniature fuse-link contact test The contact leads shall be evaluated in accordance with subclause 8.3 for: a) tensile b) bending Sub-miniature fuse-link temperature-rise test The initial current according to subclause 9.7 shall be In Note.— The maximum operating ambient temperature is +85 °C When the sub-miniature fuse-link is operating under these conditions the current load should be reduced to 0.9 In LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Rated current I In 127-3 amend © CEI Eléments de remplacement subminiatures Fusion rapide, faible pouvoir de coupure Feuille de norme Page Dimensions en millimètres CE! 881191 a) La longueur des sorties peut être adaptée l'emballage par mise en bande b) La sortie doit passer travers un trou de mm et doit avoir une section minimale assignée de 0,150 mm2 c) La forme de la section est laissée au choix Courant Tension assigné assignée * V 50 mA 63 mA 80 mA 100 mA 125 mA 160 mA 200 mA 250 mA 315 mA 400 mA 500 mA 630 mA 800 mA 1A 1,25 A 1,6 A 2A 2,5 A 3,15 A 4A 5A 250 Chute de tension maximale mV 850 750 650 600 550 500 480 440 400 370 350 320 300 280 280 250 240 200 180 160 150 Puiss an ce maximale dissipée mW** 112 124 137 158 180 210 252 289 331 389 459 529 630 735 919 1050 1260 1313 488 1680 1969 * Les valeurs intermédiaires doivent être choisies dans la série R 20 ou R 40 ** Mesurée au bout de h sous 1,5 In LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Dorties 127-3 amend © CEI Feuille de norme Eléments de remplacement subminiatures Fusion rapide, faible pouvoir de coupure Page Marquage Les éléments de remplacement subminiatures doivent porter les indications ci-après: a) courant assigné b) tension assignée c) nom du fabricant ou marque de fabrique d) symbole caractéristique F Caractéristique temps/ courant de préarc La durée de préarc doit être comprise entre les limites suivantes: Courant assigné 50 mA A inclus i 2,75 in 10 in maximal minimal maximal minimal maximal maximal 30 10 ms 3s ms 300 ms 20 ms Pouvoir de coupure Pouvoir de coupure assigné: 35 A ou lO ln selon la valeur la plus grande, essayé en courant alternatif avec les circuits représentés la figure pour l'essai du pouvoir de coupure Essai d' endurance Au courant assigné, 100 cycles suivant la méthode d'essai A du paragraphe 9.4.2 et ensuite 1,5 fois le courant assigné pendant h Essai des sorties de l'élément de remplacement subminiature Les sorties doivent être évaluées suivant le paragraphe 8.3 en ce qui concerne: a) la traction b) la poussée c) le pliage (applicable seulement si la longueur des sorties est supérieure mm) Essai d'échauffement de l'élément de remplacement subminiature Le courant initial suivant le paragraphe 9.7 doit être 1,5 In Note.– La température ambiante maximale de fonctionnement est de +85 °C Lorsque l'élément de remplacement subminiature fonctionne dans ces conditions, l'intensité du courant est normalement réduite 0,9 /n LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 2,1 in 127-3 Amend © IEC Sub-miniature fuse-links Quick-acting, low breaking capacity Standard Sheet Page Dimensions in millimetres 1EC 881/91 a) The length of the terminations may be adapted for a lead taping type of packaging b) The termination must go through a mm hole and have a rated minimum cross-sectional area of 0,150 mm2 c) The cross-sectional shape of the termination is optional Rated current * Rated voltage V 50 mA 63 mA 80 mA 100 mA 125 mA 160 mA 200 mA 250 mA 315 mA 400 mA 500 mA 630 mA 800 mA 1A 1,25 A 1,6 A 2A 2,5 A 3,15 A 4A 5A 250 Maximum voltage drop mV 850 750 650 600 550 500 480 440 400 370 350 320 300 280 280 250 240 200 180 160 150 Maximum sustained dissipation mW** 112 124 137 158 180 210 252 289 331 389 459 529 630 735 919 1050 1260 1313 1488 1680 1969 * Intermediate values shall be chosen from the R 20 or R 40 series ** Measured after h at 1,5 /n LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Terminations 127-3 Amend © IEC Standard Sheet Sub-miniature fuse-links Quick-acting, low breaking capacity Page Marking Sub-miniature fuse-links shall be marked with: a) rated current b) rated voltage c) manufacturer's name or trade mark d) characteristic symbol F Pre-arcing time/current characteristic The pre-arcing time shall be within the following limits: 50 mA at A inclusive 1n 2,75 n 10 n maximum minimum maximum minimum maximum maximum 30 10 ms 3s ms 300 ms 20 ms Breaking capacity Rated breaking capacity: 35 A or 10 In whichever is greater, tested with a.c using the circuit given in Figu re for the breaking capacity test Endurance test 100 cycles at rated current according to test method A of subclause 9.4.2 followed by h at 1,5 times the rated current Sub-miniature fuse-link contact test The contact leads shall be evaluated in accordance with subclause 8.3 for: a) tensile b) thrust c) bending (applicable only if the length of the terminations is over mm) Sub-miniature fuse-link temperature-rise test The initial current according to subclause 9.7 shall be 1,5 IR Note.— The maximum operating ambient temperature is +85 °C When the sub-miniatu re fuse-link is operating under these conditions the current load should be reduced to 0,9In LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 2,1 In Rated current 127-3 amend © CEI Eléments de remplacement subminiatures Fusion temporisée, faible pouvoir de coupure Feuille de norme Page Dimensions en millimètres a) La longueur des sotties peut être adaptée l'emballage par mise en bande b) La sortie doit passer travers un trou de mm et doit avoir une section minimale assignée de 0,150 mm2 c) La forme de la section est laissée au choix Courant Tension assigné assignée * 40 mA 50 mA 63 mA 80 mA 100 mA 125 mA 160 mA 200 mA 250 mA 315 mA 400 mA 500 mA 630 mA 800 mA 1A 1,25 A 1,6 A 2A 2,5 A 3,15 A 4A V 250 Chute de tension maximale mV 600 550 480 400 350 300 280 260 240 220 200 190 180 160 140 130 120 100 100 100 100 Puiss ance maximale dissipée mW** 150 155 160 165 170 180 190 200 220 250 280 310 360 430 500 600 730 870 1000 1200 1400 * Les valeurs intermédiaires doivent être choisies dans la série R 20 ou R 40 ** Mesurée au bout de h sous 1,5 In LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU CEI 881/91 Sorties 127-3 amend © CEI Feuille de norme Eléments de remplacement subminiatures Fusion temporisée, faible pouvoir de coupure Page Marquage Les éléments de remplacement subminiatures doivent porter les indications ci-après: a) courant assigné b) tension assignée c) nom du fabricant ou marque de fabrique d) symbole caractéristique T Caractéristique temps/ courant de préarc La durée de préarc doit être comprise entre les limites suivantes: Courant assigné 40 mA A inclus I 2,75 1n 10In maximal minimal maximal minimal maximal minimal maximal 400 ms 10s 150 ms 3s 20 ms 150 ms Essai la température de 70 ± °C Les éléments de remplacement subminiatures doivent être parcourus pendant h par un courant de 1,0 In et ne doivent pas fonctionner Pouvoir de coupure la valeur la plus grande, essayé en courant alternatif avec les Pouvoir de coupure assigné: 35 A ou 10 In circuits représentés la figure pour l'essai du pouvoir de coupure Essai d' endurance Au courant assigné, 100 cycles suivant la méthode d'essai A du paragraphe 9.4.2 et ensuite 1,5 fois le courant assigné pendant h Essai des sorties de l'élément de remplacement subminiature Les sorties doivent être évaluées suivant le paragraphe 8.3 en ce qui concerne: a) la traction b) la poussée c) le pliage (applicable seulement si la longueur des sorties est supérieure mm) Essai d'échauffement de l'élément de remplacement subminiature Le courant initial suivant le paragraphe 9.7 doit être 1,5 I Note.— La température ambiante maximale de fonctionnement est de +85 °C Lorsque l'élément de remplacement subminiature fonctionne dans ces conditions, l'intensité du courant est normalement réduite 0,9 /n LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 2,11n 127-3 Amend © IEC Standard Sheet Page Sub-miniature fuse-links Time lag, low breaking capacity Dimensions in millimetres fEC 88! / 9! a) The length I of the terminations may be adapted for a lead taping type of packaging b) The termination shall go through a turn hole and have a rated minimum cross-sectional area of 0,150 mm2 c) The cross-sectional shape of the termination is optional Rated current * Rated voltage V 40 mA 50 mA 63 mA 80 mA 100 mA 125 mA 160 mA 200 mA 250 mA 315 mA 400 mA 500 mA 630 mA 800 mA 1A 1,25 A 1,6 A 2A 2,5 A 3,15 A 4A 250 Maximum voltage drop mV 600 550 480 400 350 300 280 260 240 220 200 190 180 160 140 130 120 100 100 100 100 Maximum sustained dissipation mW** 150 155 160 165 170 180 190 200 220 250 280 310 360 430 500 600 730 870 1000 1200 1400 * Intermediate values shall be chosen from the R 20 or R 40 series ** Measured after h at 1,5 In LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Terminations 127-3 Amend © IEC Standard Sheet Sub-miniature fuse-links Time lag, low breaking capacity Page Marking Sub-miniature fuse-links shall be marked with: a) rated current b) rated voltage c) manufacturer's name or trade mark d) characteristic symbol T Pre-arcing timelcurrent characteristic The pre-arcing time/current shall be within the following limits: maximum minimum maximum minimum maximum minimum maximum 400 ms 10 s 150 ms 3s 20 ms 150 ms Test at a temperature of 70 ± °C A current of 1,0 In shall be passed through the sub-miniature fuse-links for h and they shall not operate Breaking capacity Rated breaking capacity: 35 A or 10 In whichever is greater, tested with a.c using the circuit given in Figure for the breaking capacity test Endurance test 100 cycles at rated current according to test method A of subclause 9.4.2 followed by h at 1,5 times the rated current Sub-miniature fuse-link contact test The contact leads shall be evaluated in accordance with subclause 8.3 for: a) tensile b) thrust c) bending (applicable only if the length of the terminations is over mm) Sub-miniature fuse-link temperature-rise test The initial current according to subclause 9.7 shall be 1,5 In Note.— The maximum operating ambient temperature is +85 °C When the sub-miniature fuse-link is operating under these conditions the current load should be reduced to 0,9 In LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 40 mA to A inclusive 10 1n In 2,75 n 2,1 In Rated current LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU ICS 29.120.50 Typeset an d printed by the IEC Central Office GENEVA, SWITZERLAND