1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 60730 2 7 2010 (2011)

24 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

BS EN 60730-2-7:2010 Incorporating corrigendum December 2011 BSI Standards Publication Automatic electrical controls for household and similar use Part 2-7: Particular requirements for timers and time switches BRITISH STANDARD BS EN 60730-2-7:2010 National foreword This British Standard is the UK implementation of EN 60730-2-7:2010, incorprating corrigendum December 2011 It was derived from IEC 60730-2-7:2008 It supersedes BS EN 60730-2-7:1992, which will be withdrawn on October 2013 The start and finish of text introduced or altered by corrigendum is indicated in the text by tags Text altered by CENELEC corrigendum December 2011 is indicated in the textˆ‰ by The CENELEC common modifications have been implemented at the appropriate places in the text and are indicated by tags (e.g }~) The UK participation in its preparation was entrusted to Technical Committee CPL/72, Electrical control devices for household equipment and appliances A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © The British Standards Institution 2012 ISBN 978 580 77552 ICS 39.040.99; 97.120 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2011 Amendments/corrigenda issued since publication Date Text affected 29 February 2012 Implementation of CENELEC corrigendum December 2011 EUROPEAN STANDARD EN 60730-2-7 NORME EUROPÉENNE October 2010 EUROPÄISCHE NORM ICS 97.120 Incorporating corrigendum December 2011 Supersedes EN 60730-2-7:1991 + corr Mar.2001 + A1:1997 + corr Mar.2001 + A11:1994 + corr Mar.2001 + A12:1993 + corr Mar.2001 + A13:2003 + A14:2003 English version Automatic electrical controls for household and similar use Part 2-7: Particular requirements for timers and time switches (IEC 60730-2-7:2008, modified) Dispositifs de commande électrique automatiques usage domestique et analogue Partie 2-7: Règles particulières pour les minuteries et les minuteries cycliques (CEI 60730-2-7:2008, modifiée) Automatische elektrische Regel- und Steuergeräte für den Hausgebrauch und ähnliche Anwendungen Teil 2-7: Besondere Anforderungen an Zeitsteuergeräte und Schaltuhren (IEC 60730-2-7:2008, modifiziert) This European Standard was approved by CENELEC on 2010-10-01 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels © 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members Ref No EN 60730-2-7:2010 E BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) –2– Foreword The text of the International Standard IEC 60730-2-7:2008, prepared by IEC TC 72, Automatic controls for household use, together with the common modifications prepared by the Technical Committee CENELEC TC 72, Automatic controls for household use, was submitted to the CENELEC Unique Acceptance Procedure and was approved as ˆEN 60730-2-7‰on 2010-10-01 This document supersedes EN 60730-2-7:1991 + A1:1997 + A11:1994 + A12:1993 + A13:2003 + A14:2003 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CEN and CENELEC shall not be held responsible for identifying any or all such patent rights The following dates are fixed: – – latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-10-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2013-10-01 This Part 2-7 is to be used in conjunction with EN 60730-1:2000, Automatic electrical controls for household and similar use – Part 1: General requirements, and any subsequent amendments This European Standard has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association and covers essential requirements of EC Directive 2004/108/EC See Annex ZZ Annexes ZA and ZZ have been added by CENELEC Endorsement notice The text of the International Standard IEC 60730-2-7:2008 was approved by CENELEC as a European Standard with agreed common modifications –3– BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) CONTENTS Scope and normative references Definitions General requirements .6 General notes on tests .6 Rating 6 Classification 7 Information 8 Protection against electric shock 9 Provision for protective earthing 10 Terminals and terminations 11 Constructional requirements 12 Moisture and dust resistance 10 13 Electric strength and insulation resistance 10 14 Heating 10 15 Manufacturing deviation and drift 11 16 Environmental stress 11 17 Endurance 11 18 Mechanical strength 19 Threaded parts and connections 20 Creepage distances, clearances and distances through solid insulation 21 Fire hazard testing 22 Resistance to corrosion 23 Electromagnetic compatibility (EMC) requirements – emission 24 Components 25 Normal operation 26 Electromagnetic compatibility (EMC) requirements – immunity 27 Abnormal operation 28 Guidance on the use of electronic disconnection Annex H (normative) Requirements for electronic controls 16 Annex AA (normative) Number of cycles, automatic and manual action 18 Annex ZA (normative) Normative references to international publications with their corresponding European publications 19 Annex ZZ (informative) Coverage of Essential Requirements of EC Directives 20 Table AA.1 – Values for free standing, independently mounted and in-line cord timers and time switches a 18 BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) –4– AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE – Part 2-7: Particular requirements for timers and time switches Scope and normative references This clause of Part is applicable except as follows: 1.1 Replacement: In general, this part of IEC 60730 applies to timers and time switches for household and similar use that may use electricity, gas, oil, solid fuel, solar thermal energy, etc or a combination thereof, including heating, air conditioning and similar applications This standard is also applicable to individual timers utilized as part of a control system or timers which are mechanically integral with multifunctional controls having non-electrical outlets This standard does not apply to time-delay switches (TDS) within the scope of IEC 60669-2-3 1) Throughout this standard, the word “timers” means timers and time switches, unless the type is specifically mentioned Devices which only indicate time or passage of time are not included This standard does not apply to multi-functional controls having an integrated timing function which is not capable of being tested as a separate timing device 1.1.1 This standard applies to the inherent safety, to the operating characteristics where such are associated with equipment protection and to the testing of automatic electrical control devices used in appliances and other apparatus, electrical and non-electrical, for household and similar purposes, but also extended to industrial purposes when no dedicated product standards exist, such as that for central heating, air conditioning, process heating, etc Timers for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard This standard is also applicable to timers for appliances within the scope of IEC 60335-1 This standard does not apply to timers designed exclusively for industrial applications Throughout this standard, the word "equipment" means "appliance and equipment" 1.1.2 This standard applies to automatic electrical control devices, mechanically, electromechanically, electrically or electronically operated, responsive to or controlling parameters such as temperature, pressure, passage or time, humidity, light, electrostatic effect, flow or liquid level _ 1) IEC 60669-2-3:2006, Switches for household and similar fixed electrical installations – Part 2-3: Particular requirements – Time-delay switches (TDS) –5– BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) 1.1.3 This standard applies to automatic electrical control devices serving the starting of small motors that are used principally in appliances and apparatus for household and similar purposes Such control devices may be built into or be separate from the motor 1.1.4 This standard applies to non-automatic control devices when such are associated with automatic control devices 1.2 Replacement: This standard applies to controls with a rated voltage not exceeding 690 V and a rated current not exceeding 63 A 1.3 Replacement: This standard does not take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment If a response value is of significant purpose for the safety of the user or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer shall apply 1.4 Replacement: This standard applies also to timers incorporating electronic devices, requirements for which are contained in Annex H 1.5 Normative references This subclause of Part applies except as follows: Addition: IEC 60669-1:1998, Switches for household and similar fixed-electrical installations – Part 1: General requirements 2) Amendment (1999) Amendment (2006) IEC 61010-1, Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements Definitions This clause of Part is applicable except as follows: 2.3 Definitions relating to the function of controls Additional definition: 2.3.101 timing cycle program including all the switching activities involved in a start-to-finish operation of a controlled appliance _ 2) There exists a consolidated edition 3.2 (2007) that includes edition and its Amendments and BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) 2.5 –6– Definitions of types of control according to construction Additional definitions: 2.5.101 plug-in timer timer or time switch designed for direct plug-in to a socket-outlet NOTE The plug-in timer is equipped with conductor blades, pins or other means, protruding from the enclosure of the control or the control body itself, to match the dimensional parameters of the socket-outlet to which the control will be connected 2.5.102 TV timer control for television equipment that can be set by the user, switching very high inrush currents of a very short duration generated by electrical power supply components and associated electronic component parts with various electrical characteristics NOTE Examples are power transformers, electronic tube filaments, large electric capacitors and others in television receivers, radio and video products 2.5.103 synchronous timer timer or a time switch in which the transmission is effected by a device that is time-based on the frequency of the power supply for the prime mover or the load 2.5.104 hand-wound timer timer or time switch in which the transmission is provided by actuation General requirements This clause of Part is applicable General notes on tests This clause of Part is applicable except as follows: 4.1.4 Addition: }Text deleted~ 4.3.2.1 Addition: }Text deleted~ Rating This clause of Part is applicable –7– BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) Classification This clause of Part is applicable except as follows: 6.3 6.3.6 According to their purpose Additional subclause: 6.3.6.101 – TV timer; }Text deleted~ 6.4 6.4.3 According to features of automatic action Additional subclauses: 6.4.3.101 – a timing action which automatically resets upon loss of the electrical supply (Type 1.Q or 2.Q); 6.4.3.102 – a timing action which is interrupted upon loss of the electrical supply and resumes at the point of interruption upon restoration of the electrical supply (Type 1.R or 2.R); 6.4.3.103 – a timing action of a time switch which, after interruption of the electrical supply for any interval up to the declared period of power reserve, resumes its intended operating sequence as if no interruption of the supply has occurred (Type 1.S or 2.S); 6.4.3.104 – a timing action with a declared running accuracy in an ambient temperature of 20 °C to 25 °C (Type 1.T or 2.T); 6.4.3.105 – a timing action in which the difference between set time and actual switching time does not exceed the declared amount (Type 1.U or 2.U) 6.5 According to the degree of protection and control pollution degree Additional subclause: 6.5.101 6.10 According to declared industrial environmental conditions (see IEC 61010-1): According to number of cycles of actuation (M) for each manual actuation Additional subclauses: 6.10.101 – 500 cycles; 6.10.102 – 500 cycles; 6.10.103 – 000 cycles 6.15 According to construction Additional subclause: 6.15.101 – plug-in timer BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) –8– Information This clause of Part is applicable except as follows: 7.2 Methods of providing information 7.2.9 Addition: }Where symbols are used~ , for Type 1.S or 2.S actions, the power reserve is to be marked on the timer by the letter "R", followed by the duration of the power reserve, followed by the symbol indicating the time unit as follows: minutes hours h days d years a Table 7.2 Modification: Replace the lines corresponding to items 7, 26, 27 and 28 by the following: Information The type of load controlled by each circuit 7) 101) Clause or subclause Method 6.2 C 14 17 26 Number of cycles of actuation (M) for each manual action 102) 6.10 X 27 Number of automatic cycles (A) for each automatic action 102) 6.11 X 6.16 X Clause or subclause Method 28 Ageing period (Y) for Type 1.M or 2.M action 102) Add the following additional items: Information ‰ ˆ Text deleted 102 Power reserve duration 6.4.3.103 }C ~ 6.4.3.104 D ‰ ˆ Text deleted 104 Running accuracy and setting accuracy 6.4.3.105 11.4.104 –9– BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) }Text deleted~ Protection against electric shock This clause of Part is applicable Provision for protective earthing This clause of Part is applicable 10 Terminals and terminations This clause of Part is applicable 11 Constructional requirements This clause of Part is applicable except as follows: 11.4 Actions Additional subclauses: 11.4.101 Type 1.Q or 2.Q action A Type 1.Q or 2.Q action shall be so designed that it resets automatically upon loss of the electrical supply Compliance is checked by inspection and by test 11.4.102 Type 1.R or 2.R action A Type 1.R or 2.R action shall be so designed that it is interrupted upon loss of the electrical supply and resumes at the point of interruption upon restoration of the electrical supply Compliance is checked by inspection and by test BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) 11.4.103 – 10 – Type 1.S or 2.S action A Type 1.S or 2.S action shall be so designed that, after interruption of the electrical supply for any interval up to the declared period of power reserve, it resumes its intended operating sequence as if no interruption of the supply has occurred Compliance is checked by a switching operation, carried out immediately after a given period of power reserve The power reserve shall be obtained at a voltage equal to 0,85 times rated voltage and 1,1 times rated voltage Each test shall be carried out once after a complete wind-up of the time switch In the case of a manually wound time switch, the running time shall be as declared }Text deleted ~ The minimum running time shall be three days and preferably up to eight days 11.4.104 Type 1.T or 2.T action A Type 1.T or 2.T action shall be so designed that its running accuracy in an ambient temperature of 20 °C to 25 °C is as declared }Text deleted~ The running accuracy for time switches shall be within ±60 s per day For the power reserve period of synchronous time switches (Type S.T), the running accuracy shall be within ±500 s per day The deviation from the calculated elapsed time shall be less than 30 per year, relative to } actual elapsed time under fluctuations of 0,85 times to 1,1 times rated voltage and ±2 % rated frequency Compliance is checked by inspection and by test 11.4.105 Type 1.U or 2.U action A Type 1.U or 2.U action shall be so designed that its setting means, dial assembly, indicating devices and switch operating means function so that the difference between set time and actual time shall not be more than the declared amount This deviation shall not be more than: ±1 for time switches with "hour" dial; ±30 for time switches with "24 hour" dial; ±3,5 h for time switches with "7 day" dial; ±14 h for time switches with "month" dial; ±7 days for time switches with "12 month" dial Compliance is checked only on time switches with hour, 24 hour and day dial by three consecutive measurements 12 Moisture and dust resistance This clause of Part is applicable 13 Electric strength and insulation resistance This clause of Part is applicable 14 Heating This clause of Part is applicable – 11 – BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) }Text deleted~ 15 Manufacturing deviation and drift This clause of Part is applicable 16 Environmental stress This clause of Part is applicable 17 Endurance This clause of Part is applicable except as follows: 17.1.3 17.1.3.3 Test sequence and conditions Addition: For manual actions which have been tested during the tests of 17.7 and 17.8, the number of cycles of actuation is reduced by the number of cycles carried out during those tests If a clutch is used during the tests of 17.10 to 17.13 inclusive, care should be taken to ensure that it does not fail due to the acceleration If it fails or is considered liable to fail, the speeds of actuation shall be as specified, but rest periods shall be introduced between cycles to allow the heat dissipation which would occur during normal use Additional subclause: 17.1.3.101 At the end of each cycle, for timers only, an appropriate actuation shall be performed to initiate the next cycle If a timer or time switch has different programs, that program which utilizes the maximum number of contact operations shall be chosen, unless a timer with a special test program has been submitted by the manufacturer If the program does not cause all the contacts to be operated, the test shall be repeated on a new set or sets of samples operating on other programs to ensure that all contacts are tested These extra samples need not be tested where the design is such that the results can be reasonably predicted from the result of the first set of samples, as could be done if the design of all contacts were identical BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) – 12 – If a timer with a special test program is used, it shall be so designed that it is possible, by carrying out the special program, to reasonably predict the test results for all specific application programs of the timer In-line cord, free-standing and independently mounted controls shall be tested as follows – For timers declared for resistive load, the number of cycles of contact operation for each contact of the time switch shall be A = 000 The number of cycles of actuation (M) for each manual action of the time switch shall be M = 500 (inducing 500 cycles of contact operation) – For timers declared for resistive or inductive load, the number of cycles of contact operation for each contact so rated shall be 000, consisting of a first number of cycles A = 500, to be tested with a substantially resistive load as specified in Table 17.2-1, ˆText deleted‰ followed by a second number of cycles, A = 500, which shall be conducted at the conditions specified in Table 17.2-1 ˆText deleted‰ , for resistive or inductive load The number of cycles of actuation (M) for each manual action of these timers shall be M = 500 (inducing 500 cycles of contact operation, tested under resistive load conditions) – If the timer requires an external electrical or mechanical signal to move it from a rest position this shall be simulated, if necessary in the manner declared by the manufacturer – For timers and time switches with Type actions, any electrically driven prime mover shall for at least 50 % of the test, be connected to a supply of 0,9 V R , all other loads and connections remaining as in 17.7 – For timers and time switches with Type actions, if there is any failure attributable to the acceleration (such as the excessive use of a clutch), then the test is held to be invalid and should be repeated in another manner 17.2 Electrical conditions for the tests Table 17.2-1 – Electrical conditions for the overvoltage test Modification: In the line “Declared specific load (classified 6.2.3)” in the column “Type of circuit as 101) classified in 6.2” add reference to note Additional note to Table 17.2-1: 101) For the tests of tungsten filament lamp load, the load and test of 18.2 of IEC 60669-1, and for fluorescent lamp load, the load of 19.2 of IEC 60669-1, shall be used, under the conditions as specified in 17.6 Table 17.2-2 – Electrical conditions for the overload tests of 17.7 and 17.10 ˆText deleted‰ Table 17.2-3 – Electrical conditions for the overload tests of 17.8, 17.9, 17.11, 17.12 and 17.13 ˆText deleted‰ Additional notes to Tables 17.2-2 and 17.2-3: ˆText deleted‰ – 13 – BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) Additional subclause: 17.2.101 ˆText deleted‰ 17.15 Not applicable 17.16 Test for particular purpose controls Additional subclauses: 17.16.101 Tungsten-filament lamp loads 17.16.101.1 Timers classified by the manufacturer under 6.2.3, declared specific load, for tungsten-filament lamp load with a rating as declared according to Table 7.2, requirement 7, are submitted to the test tungsten-filament lamp test of 18.2 of IEC 60669-1, with the number of contact cycles as declared by the manufacturer The operating cycle shall be such that the lamps are off for at least 55 s of each test cycle Timers classified for use with tungsten-filament lamp loads are tested at rated voltage and at no less than 1,2 times the rated current The test is carried out by using a number of 200 W tungsten-filament lamps If such lamps with rated voltage equal to the rated voltage of the timer are not available, lamps with the nearest lower voltage can be used but should not be lower than 95 % of the rated voltage of the timer, if possible The test voltage shall be the rated voltage of the lamps The number of lamps shall be the smallest number giving a test current not less than 1,2 times the rated current of the timer The operating cycle shall be such that the lamps are off for at least 55 s of each test cycle The number of operations shall be as declared The available short-circuit current of the supply shall be at least 500 A During the test, no sustained arcing shall occur at the contacts of the samples and after the test they shall show no damage which may impair their further use Examples: Timer rating 10 A, 250 V, 200 W tungsten-filament lamps only with rating of 240 V available Test voltage 240 V and number of lamps (240 × 1,2 × 10/200 = 15) 17.16.101.2 Timers classified by the manufacturer under 6.2.3 for fluorescent lamp loads with a rating as declared according to Table 7.2, requirement are submitted to the fluorescent lamp test of 19.2 of IEC 60669-1, with the number of contact cycles as declared by the manufacturer BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) 17.16.101.3 – 14 – }Text deleted~ ˆSub clause deleted ‰ 17.16.102 Synthetic loads ˆText deleted‰ 17.16.103 TV timers ˆDelete the subordinate clauses 17.16.103.1 to 17.16.103.1.5 inclusive‰ – 15 – BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) 18 Mechanical strength This clause of Part is applicable except as follows: 18.6.1 Not applicable to plug-in time switches 19 Threaded parts and connections This clause of Part is applicable 20 Creepage distances, clearances and distances through solid insulation This clause of Part is applicable 21 Fire hazard testing This clause of Part is applicable except as follows: 21.2.4 Addition: Other small parts (gears, cams, levers and the like) which are not in direct contact with live parts or current-carrying parts are not submitted to the glow-wire test Additional subclause: }Text deleted~ 22 Resistance to corrosion This clause of Part is applicable 23 Electromagnetic compatibility (EMC) requirements – emission This clause of Part is applicable 24 Components This clause of Part is applicable 25 Normal operation This clause of Part is applicable 26 Electromagnetic compatibility (EMC) requirements – immunity This clause of Part is applicable 27 Abnormal operation This clause of Part is applicable 28 Guidance on the use of electronic disconnection This clause of Part is applicable Figures The figures of Part are applicable Annexes The annexes of Part are applicable except as follows: }Annex D deleted ~ BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) – 16 – Annex H (normative) Requirements for electronic controls This annex of Part is applicable except as follows: H.7 Information Table 7.2 Replace the text in requirement 54 with the words “Not applicable” Add to note 17), after the second paragraph of class A, the following new paragraph: Software functions for timers and time switches within the scope of IEC 60730-2-7 are classified as class A, unless otherwise declared by the manufacturer H.11.12 Controls using software Add after the first paragraph, the following new paragraph: Software functions for timers and time switches within the scope of IEC 60730-2-7 are classified as class A, unless otherwise declared by the manufacturer H.26.6 Test of influence of voltage unbalance This subclause is not applicable H.26.9 Electrical fast transient/burst test Additional subclause: H.26.9.101 Test procedure The control is subjected to five tests The tests are performed with the maximum number of outputs connected as permitted by the operating sequence Three tests are performed with power delivered to the load(s) and two tests are performed without power delivery to the load(s) H.26.11 Electrostatic discharge test Addition: Five discharges are applied to all accessible surfaces The tests are performed with the maximum number of outputs connected as permitted by the operating sequence Three tests are performed with power delivered to the load(s) and two tests are performed without power delivered to the load(s) – 17 – BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) Accessible parts include parts which are accessible after the removal of detachable parts as described in 8.1.9.5 of Part }Text deleted~ Additional subclause: H.26.15.4.101 The compliance criteria shall comply with H.26.15.4, item a) in Part BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) – 18 – Additional annex: Annex AA (normative) Number of cycles, automatic and manual action Table AA.1 – Values for free standing, independently mounted and in-line cord timers and time switches a A b M c Type of load 000 500 Substantially resistive 500 250 Resistive and inductive 25 000 50 High-inrush current (in-line cord TV-timers) a Values for integrated and incorporated controls are given in the appropriate equipment standard b Automatic c Manual _ – 19 – BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies NOTE Where an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies Publication Year Title EN/HD Year IEC 60669-1 (mod) 1998 1999 + A1 (mod) 2006 + A2 (mod) Switches for household and similar fixedelectrical installations Part 1: General requirements EN 60669-1 + A1 + A2 1999 2002 2008 IEC 61010-1 Safety requirements for electrical equipment EN 61010-1 for measurement, control, and laboratory use Part 1: General requirements - - BS EN 60730-2-7:2010 EN 60730-2-7:2010 (E) – 20 – Annex ZZ (informative) Coverage of Essential Requirements of EC Directives This European Standard has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association and within its scope the standard covers all relevant essential requirements as given in Article of Annex I of the EC Directive EMC (2004/108/EC) Compliance with this standard provides one means of conformity with the specified essential requirements of the Directive concerned WARNING: Other requirements and other EC Directives may be applicable to the products falling within the scope of this standard This page deliberately left blank NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW British Standards Institution (BSI) BSI is the national body responsible for preparing British Standards and other standards-related publications, information and services BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited About us Revisions We bring together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions Our British Standards and other publications are updated by amendment or revision The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process Organizations of all sizes and across all sectors choose standards to help them achieve their goals Information on standards We can provide you with the knowledge that your organization needs to succeed Find out more about British Standards by visiting our website at bsigroup.com/standards or contacting our Customer Services team or Knowledge Centre Buying standards You can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at bsigroup.com/shop, where hard copies can also be purchased If you need international and foreign standards from other Standards Development Organizations, hard copies can be ordered from our Customer Services team Subscriptions Our range of subscription services are designed to make using standards easier for you For further information on our subscription products go to bsigroup.com/subscriptions With British Standards Online (BSOL) you’ll have instant access to over 55,000 British and adopted European and international standards from your desktop It’s available 24/7 and is refreshed daily so you’ll always be up to date You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single copy and subscription format, by becoming a BSI Subscribing Member PLUS is an updating service exclusive to BSI Subscribing Members You will automatically receive the latest hard copy of your standards when they’re revised or replaced To find out more about becoming a BSI Subscribing Member and the benefits of membership, please visit bsigroup.com/shop With a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet Licences can cover as few or as many users as you wish With updates supplied as soon as they’re available, you can be sure your documentation is current For further information, email bsmusales@bsigroup.com BSI Group Headquarters 389 Chiswick High Road London W4 4AL UK We continually improve the quality of our products and services to benefit your business If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please inform the Knowledge Centre Copyright All the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that owns copyright in the information used (such as the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI Details and advice can be obtained from the Copyright & Licensing Department Useful Contacts: Customer Services Tel: +44 845 086 9001 Email (orders): orders@bsigroup.com Email (enquiries): cservices@bsigroup.com Subscriptions Tel: +44 845 086 9001 Email: subscriptions@bsigroup.com Knowledge Centre Tel: +44 20 8996 7004 Email: knowledgecentre@bsigroup.com Copyright & Licensing Tel: +44 20 8996 7070 Email: copyright@bsigroup.com

Ngày đăng: 14/04/2023, 14:38

Xem thêm:

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN