1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 15037 4 2010 + a1 2013

58 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 58
Dung lượng 1,69 MB

Nội dung

BRITISH STANDARD Precast concrete products — Beam-andblock floor systems Part 4: Expanded polystyrene blocks ICS 91.100.30 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BS EN 15037-4:2010 +A1:2013 BS EN 15037-4:2010+A1:2013 National foreword This British Standard is the UK implementation of EN 15037-4:2010+A1:2013 It supersedes BS EN 15037-4:2010, which is withdrawn The start and finish of text introduced or altered by amendment is indicated in the text by tags Tags indicating changes to CEN text carry the number of the CEN amendment For example, text altered by CEN amendment A1 is indicated by !" The UK participation in its preparation was entrusted to Technical Committee B/524, Precast concrete products A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 February 2010 © The British Standards Institution 2013 Published by BSI Standards Limited 2013 ISBN 978 580 79500 Amendments/corrigenda issued since publication Date Comments 30 June 2013 Implementation of CEN amendment A1:2013 EUROPEAN STANDARD EN 15037-4:2010+A1 NORME EUROPÉENNE EUROPÄISCHE NORM May 2013 ICS 91.100.30 Supersedes EN 15037-4:2010 English Version Precast concrete products - Beam-and-block floor systems Part 4: Expanded polystyrene blocks Produits préfabriqués en béton - Systèmes de planchers poutrelles et entrevous - Partie 4: Entrevous en polystyrène expansé Betonfertigteile - Balkendecken mit Zwischenbauteilen Teil 4: Zwischenbauteile aus Polystyrolhartschaum This European Standard was approved by CEN on November 2009 and includes Amendment approved by CEN on 14 March 2013 CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels © 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members Ref No EN 15037-4:2010+A1:2013: E BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Contents Page The numbering of clauses is strictly related to EN 13369:2004, Common rules for precast concrete products, at least for the first three digits When a clause of EN 13369:2004 is not relevant or included in a more general reference of this standard, its number is omitted and this can result in a gap on numbering Foreword Introduction Scope Normative references Terms and definitions 4.1 4.2 4.3 Requirements Material requirements Production requirements Finished product requirements 5.1 5.2 5.3 5.4 5.5 Test methods 13 Measuring of dimensions 13 Mechanical strength 17 Compressive resistance test 25 Thermal conductivity 25 Thermal resistance of the floor system 25 6.1 6.2 6.3 Evaluation of conformity 25 General 25 Initial type tests 25 Factory production control 26 Marking 26 Technical documentation 26 Annex A (normative) Sampling for initial type testing and for independent testing of consignments 27 A.1 General 27 A.2 Sampling procedure 27 Annex B (normative) Factory production control 29 Annex C (normative) Gravity loading tests 31 C.1 Test rig 31 C.2 Procedure 37 C.3 Test report 37 Annex D (normative) Calibration of concentrated loads testing machine 39 D.1 Sample 39 D.2 Procedure 39 D.3 Validity 40 Annex E (normative) Compliance criteria for resistance to concentrated loads 41 Annex F (informative) Calculation assumptions for calculating the thermal resistance of floors 42 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Directive 45 ZA.1 Scope and relevant characteristics 45 ZA.2 Procedure for attestation of conformity of EPS blocks for beam-and-block floor systems 46 ZA.3 CE marking and labelling 51 Bibliography 55 BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Foreword This document (EN 15037-4:2010+A1:2013) has been prepared by Technical Committee CEN/TC 229 “Precast concrete products”, the secretariat of which is held by AFNOR, and was examined by and agreed with a joint working party appointed by the Liaison Group CEN/TC 229-TC 250, particularly for its compatibility with structural Eurocodes This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2013, and conflicting national standards shall be withdrawn at the latest by November 2013 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights This document includes Amendment 1, approved by CEN on 2013-03-14 This document supersedes EN 15037-4:2010 The start and finish of text introduced or altered by amendment is indicated in the text by tags !" This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s) For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document EN 15037, Precast concrete products ― Beam-and-block floor systems, consists of five parts:  Part 1: Beams  Part 2: Concrete blocks  Part 3: Clay blocks  Part 4: Expanded polystyrene blocks  Part 5: Lightweight blocks for simple formwork 1) For common aspects of concrete products, reference is made to EN 13369, from which also the relevant requirements of the EN 206-1 are taken The references to EN 13369 by CEN/TC 229 product standards are intended to make them homogeneous and to avoid repetitions of similar requirements Eurocodes are taken as a common reference for design aspects The installation of some structural precast concrete products is dealt with by ENV 13670-1 In all countries it may be accompanied by alternatives for national application and it should not be treated as a European Standard The program of standards for structural precast concrete products comprises the following European Standards, in some cases consisting of several parts: EN 1168, Precast concrete products — Hollow core slabs 1) To be developed BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) EN 12794, Precast concrete products — Foundation piles EN 12843, Precast concrete products — Masts and poles EN 13224, Precast concrete products — Ribbed floor elements EN 13225, Precast concrete products — Linear structural elements EN 13693, Precast concrete products — Special roof elements EN 13747, Precast concrete products — Floor plates for floor systems EN 13978, Precast concrete products — Precast concrete garages EN 14843, Precast concrete products — Stairs EN 14844, Precast concrete products — Box culverts EN 14991, Precast concrete products — Foundation elements EN 14992, Precast concrete products — Wall elements EN 15037, Precast concrete products — Beam-and-block floor systems EN 15050, Precast concrete products — Bridge elements EN 15258, Precast concrete products — Retaining wall elements According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Introduction The evaluation of conformity refers to the completed precast elements which are supplied to the market and covers all the production operations carried out in the factory For design rules reference is made to EN 1992-1-1 Additional complementary rules are provided where necessary NOTE This European Standard is applied in Europe under different climatic and geographical conditions, different levels of protection and under different, well-established, regional traditions and experience Classes for EPS blocks have been introduced to cover these situations Where such general solutions were not possible, the relevant clauses contain permission for the application of national standards or provisions valid in the place of use of the EPS Blocks (see 4.3.3) BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Scope This European Standard deals with the requirements and the basic performance criteria for blocks made in expanded polystyrene (EPS), used in conjunction with precast concrete beams in compliance with EN 15037-1, with or without cast-in-situ concrete for the construction of beam-and-block floor systems EPS block may be totally made in EPS or combined with different materials such as plaster or wood wool If EPS is combined with other materials, these materials should not contribute to more than 50 % of the mechanical resistance of the block If not, the block is covered by EN 15037-5, Precast concrete products ― Beam-and-block floor systems ― Part 5: Lightweight blocks for simple formwork Examples of typology of floor systems are given in Annex B of EN 15037-1:2008 Normative references The following referenced documents are indispensable for the application of this document For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies EN 826, Thermal insulating products for building applications — Determination of compression behaviour EN 1365-2, Fire resistance tests for loadbearing elements — Part 2: Floors and roofs EN 12390-4:2000, Testing hardened concrete — Part 4: Compressive strength — Specification for testing machines EN 12667, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Products of high and medium thermal resistance EN 13163:2008, Thermal insulation products for buildings — Factory made products of expanded polystyrene (EPS) — Specification EN 13369:2004, Common rules for precast concrete products EN 15037-1:2008, Precast concrete products — Beam-and-block floor systems — Part 1: Beams EN 13501-1, Fire classification of construction products and buildings elements — Part 1: Classification using test data from reaction to fire tests EN ISO 10211, Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations (ISO 10211:2007) !EN ISO 11925-2, Reaction to fire tests — Ignitability of products subjected to direct impingement of flame — Part 2: Single-flame source test (ISO 11925-2)" Terms and definitions For the purposes of this document, the following terms and definitions apply 3.1 EPS block type R1 block with no mechanical function in the final floor system NOTE Its only mechanical function is that of formwork during the construction of the floor system BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Figure — Examples of EPS blocks type R1 3.2 EPS block type R2 block that contributes to the mechanical function of the final floor in conjunction with a timber deck or screed NOTE EPS blocks type R2 are generally used with self-bearing beams Figure — Examples of EPS blocks type R2 3.3 cut block EPS block formed by cutting from EPS block 3.4 moulded block EPS block formed by moulding 3.5 family group of products for which the test results for one or more characteristics from any one product within the family are valid for all other products within the family 3.6 batch quantity of EPS blocks defined by:  a same reference of raw material;  similar parameters and conditions of expansion;  similar parameters and conditions of moulding;  an expanded volume which does not exceed 000 m BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Requirements 4.1 Material requirements The material EPS used shall comply the relevant requirements defined in EN 13163 If other materials are used in combination with EPS, there suitability shall be established The establishment of suitability may result from a European Standard which refers specifically to the use of this material in building products; in absence of a European Standard it may also result, under the same conditions, from an ISO standard Where this material is not covered by a European or International Standard, or if it deviates from the requirements of these standards, the establishment of suitability may result from:  the relevant national standards or provisions valid in the place of use of the product which refer specifically to the use of this material in building products; or  a European Technical Approval specifically for the use of this material in building products 4.2 Production requirements Only the materials in accordance with 4.1 shall be used in the production of EPS blocks 4.3 Finished product requirements 4.3.1 Geometrical properties NOTE For technical documentation, see Clause 4.3.1.1 Production tolerances 4.3.1.1.1 Dimensional tolerances The dimensions shall be verified according to 5.1.1 The tolerances on the dimensions are given in Table BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Annex F (informative) Calculation assumptions for calculating the thermal resistance of floors In general, calculation is performed for the system based on its dimensional properties However, the following simplifications and assumptions are accepted: a) lateral clearance between the support nib and the beam (dimension j3): Calculation is performed as though this space were filled with concrete; b) lateral clearance between the toe of the beam and the block (dimension j1): Calculation is performed as though this space were filled with polystyrene; this clearance will be continuous down to the air space as shown in Figure F.1 Key EPS block air space Figure F.1 — Clearance between the beam and the block In the case of a system combining blocks having a support nib shape different from that of the toe of the beam, the calculations shall be performed as shown in the following diagrams: BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Key EPS block concrete Figure F.2 — Support nib shape different from that of the toe of the beam vertical clearance between the toe of the beam and the tongue (dimension j2): The air space is introduced as an equivalent thermal conductivity which is calculated in accordance with EN ISO 6946 c) Key r y tongue overlap width lateral clearance of the tongue connection Figure F.3 — Clearance and overlap of the tongue d) tongue overlap (dimension r): The calculation performed is valid only for r ≥ 10 mm In other configurations, a special study shall be performed; e) lateral clearance of the tongue connection (dimension y): BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) 1) if < y ≤ mm: calculation is performed with a closed, unventilated air space, the equivalent thermal conductivity of which is calculated in accordance with EN ISO 6946; 2) if < y ≤ 10 mm: calculation is performed in accordance with EN ISO 10077-2, i.e with a closed, slightly ventilated air space, the equivalent thermal conductivity of which is equal to twice that calculated in accordance with EN ISO 6946; 3) if y > 10 mm: calculation is performed by applying surface heat transfer to the developed surface created by the tongue; f) representation of the cores: the thermal conductivity of the air in the cores is represented by its equivalent thermal conductivity determined in accordance with EN ISO 6946 Non rectangular cores are transformed into an equivalent rectangular surface in accordance with the method given by EN ISO 10077-2, and the thermal conductivity calculated as per EN ISO 6946 based on this equivalent rectangular surface is applied to the true geometry of the cores; g) surface heat transfer: the calculations are performed assuming a floor over a crawl space, a basement or a cellar (descending vertical thermal flow); h) interior and exterior temperature: the calculation being performed in steady-state conditions, the imposed temperature difference is not an influential parameter However, calculations are usually performed with an interior temperature of 20 °C and an exterior temperature of °C, i.e a difference of 20 K; i) thermal conductivity of materials: the concrete shall be represented by a thermal conductivity of W/(m⋅K) (beams and compression flange) The thickness of the compression flange shall be cm unless otherwise specified The thermal conductivity of the expanded polystyrene to be allowed for is given below as a function of the type of polystyrene; j) the lines separating two materials having the same thermal properties on the system diagrams used for the calculation may be eliminated for meshing; k) for blocks with a variable core cross section (tapered base) over the length of the block, the calculation shall be performed for the floor system built with the block presenting mean core cross sections; l) when a core is truncated on the system drawing used for calculation, the thermal conductivity of the core is that obtained by calculation based on its complete geometry BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Directive ZA.1 Scope and relevant characteristics This European Standard has been prepared under the mandate M/100 "Precast Concrete Products" 2) given to CEN by the European Commission and the European Free Trade Association The clauses of this European Standard shown in this annex meet the requirements of the mandate given under the EU Construction Products Directive (89/106/EEC) Compliance with these clauses confers a presumption of fitness of the EPS blocks for beam-and-block floor systems covered by this annex for the intended uses indicated herein; reference shall be made to the information accompanying the CE marking !deleted text" This annex establishes the conditions for CE marking of blocks made of EPS, used in conjunction with beams in compliance with EN 15037-1 for beam-and-block floor systems, used for the construction of the structures of buildings and other civil engineering works, except bridges and shows the relevant clauses applicable This annex has the same scope as Clause of this standard and is defined by Table ZA.1 2) As amended BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Table ZA.1 — Relevant clauses for EPS blocks used in beam-and-block floor systems Essential characteristics Detailing Load bearing capacity (by testing) Requirement clauses in this European Standard 4.3.1 Geometrical properties 4.3.3 Mechanical resistance 4.3.4 Compressive resistance (if relevant) Resistance to fire 4.3.5.1 Resistance to fire Reaction to fire 4.3.5.2 Reaction to fire Airborne sound insulation and impact noise transmission (when 4.3.6 Acoustic properties the product is intended also for acoustic applications) Levels and/or a class(es)! " Notes and unit None mm Class KN, N/mm Testing, tabulated data, calculation A1 to F None dB or declared value of gross dry density and declared configuration Thermal conductivity and thermal 4.3.7 Thermal properties resistance None Declared value of thermal conductivity in W/(m⋅K) and thermal resistance !deleted text" in m ⋅K/W Durability 4.3.8 Durability None Ambient conditions Dangerous substances !4.3.9 Dangerous substances" None !deleted text" a ! The experience shows that EPS on the market are classified E or F." The requirement on a certain characteristic is not applicable in those Member States (MSs) where there are no regulatory requirements for that characteristic for the intended use of the product In this case, manufacturers placing their products on the market of these MSs are not obliged to determine nor to declare the performance of their products with regard to this characteristic and the option "No performance determined" (NPD) in the information accompanying the CE marking (see ZA.3) may be used The NPD option may not be used, however, where the characteristic is subject to a threshold level ZA.2 Procedure for attestation of conformity of EPS blocks for beam-and-block floor systems ! ZA.2.1 System of attestation of conformity The system of attestation of conformity of EPS blocks for beam-and-block floor systems, for the essential characteristics indicated in Table ZA.1, in accordance with the decision of the Commission 1999/94/EC of 25 January 1999 as amended by Commission Decision 2012/202/EU of 29 March 2012 (published as L109 the 21 April 2012) and as given in Annex III of the Mandate M/100 "Precast concrete products", is shown in Table ZA.2, for the indicated intended use and relevant levels or classes: BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Table ZA.2 — System of attestation of conformity Product Intended use Level or class Attestation of conformity system for structural use - 2+ (A1, A2, B, C)* (A1, A2, B, C)**, D, E (A1 to E)***, F Precast normal/lightweight/autoclaved aerated concrete products : EPS blocks for beamand-block floor systems Beam/block floor units and elements incorporating organic materials For uses subject to regulations on reaction to fire System 1: See Directive 89/106/EEC (CPD) Annex III.2.(i), without audit testing of samples System 2+: See Directive 89/106/EEC (CPD) Annex III.2.(ii), First possibility, including certification of the factory production control by an approved body on the basis of initial inspection of factory production and of factory production control as well as of its continuous surveillance, assessment and approval System 3: See Directive 89/106/EEC (CPD) Annex III.2.(ii), Second possibility System 4: See Directive 89/106/EEC (CPD) Annex III.2.(ii), third possibility * Products/materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g an addition of fire retardants or a limiting of organic material) ** Products/materials not covered by footnote (*) *** Products/materials that not require to be tested for reaction to fire (e.g Products/materials of Class A1 according to the Decision 96/603/EC, as amended) The attestation of conformity of EPS blocks for beam-and-block floor systems, for the essential characteristics indicated in Table ZA.1, shall be based on the evaluation of conformity procedure indicated in Tables ZA.3a to ZA.3c, resulting from the application of the clauses of this or other European Standards indicated therein BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Table ZA.3.a — Assignment of evaluation of conformity tasks for EPS blocks for beam-and-block floor systems under system 2+ , classified (A1, A2, B, C)* for reaction to fire under system Content of the task Evaluation of conformity clauses to apply Factory production control (FPC) Parameters related to all characteristics of Table ZA.1 relevant for the intended use 6.3 Further testing of samples taken at factory All characteristics of Table ZA.1 relevant for the intended use 6.3 Initial type testing by the manufacturer Parameters related to all characteristics of Table ZA.1 relevant for the intended use except reaction to fire 6.2 Initial type testing Reaction to fire 6.2 Initial inspection of factory and of FPC Reaction to fire 6.3 Continuous surveillance, assessment and approval of FPC Reaction to fire 6.3 Initial inspection of factory and of FPC Parameters related to the characteristics of Table ZA.1, i.e Tasks Tasks under the responsibility of the manufacturer Tasks under the responsibility of the product certification body Tasks under the responsibility of the FPC certification body Continuous surveillance, assessment and approval of FPC  dimensions;  mechanical resistance;  resistance to fire;  durability relevant 6.3 6.3 Table ZA.3.b— Assignment of evaluation of conformity tasks for EPS blocks for beam-and-block floor systems under system 2+ , classified (A1, A2, B, C)**, D, E for reaction to fire under system Tasks Tasks under the responsibility of the manufacturer Tasks under the responsibility of the FPC certification body Content of the task Evaluation of conformity clauses to apply Factory production control (FPC) Parameters related to all characteristics of Table ZA.1 relevant for the intended use 6.3 Initial type testing All characteristics of Table ZA.1 relevant for the intended use except the reaction to fire 6.2 Initial type testing by a notified laboratory Reaction to fire 6.2 Further testing of samples taken at factory according to the prescribed test plan Parameters related to all characteristics of Table ZA.1 relevant for the intended use 6.2 Initial inspection of factory and of FPC Parameters related to the relevant characteristics of Table ZA.1, i.e 6.3 Continuous surveillance, assessment and approval of FPC  dimensions;  mechanical resistance;  resistance to fire;  durability 6.3 BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Table ZA.3.c— Assignment of evaluation of conformity tasks for EPS blocks for beam-and-block floor systems under system 2+ , classified (A1 to E)***, F for reaction to fire under system Content of the task Evaluation of conformity clauses to apply Factory production control (FPC) Parameters related to EC of Table ZA.1 relevant for the intended use 6.3 Initial type testing Parameters related to all characteristics of Table ZA.1 relevant for the intended use 6.2 Further testing of samples taken at factory according to the prescribed test plan Parameters related to all characteristics of Table ZA.1 relevant for the intended use 6.2 Initial inspection of factory and of FPC Parameters related to the characteristics of Table ZA.1, i.e 6.3 Tasks Tasks under the responsibility of the manufacturer Tasks under the responsibility of the FPC certification body Continuous surveillance, assessment and approval of FPC  dimensions;  mechanical resistance;  resistance to fire;  durability relevant 6.3 ZA.2.2 EC Certificate and Declaration of conformity In case of products under systems 2+ and (for reaction to fire) When compliance with the conditions of this annex is achieved, the certification body shall draw up the EC Certificate of conformity (for fire only), which entitles the manufacturer to affix the CE marking The EC certificate of conformity shall include:  name, address and identification number of the certification body;  name and address of the manufacturer, or his authorised representative established in the EEA, and place of production; NOTE The manufacturer may also be the person responsible for placing the product onto the EEA market, if he takes responsibility for CE marking  description of the product (type, identification, use, );  provisions to which the product conforms (i.e Annex ZA of this EN);  particular conditions applicable to the use of the product (e.g provisions for use under certain conditions);  the number of the certificate;  conditions of validity of the certificate, where applicable;  name of, and position held by, the person empowered to sign the certificate BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) When compliance with the conditions of this annex is achieved, and once the notified body has drawn up the certificate mentioned below (for characteristics subject to system 2+ excluding the reaction to fire), the manufacturer or his agent established in the EEA shall draw up and retain a declaration of conformity, which entitles the manufacturer to affix the CE marking This declaration shall include:  name and address of the manufacturer, or his authorised representative established in the EEA, and the place of production; NOTE The manufacturer may also be the person responsible for placing the product onto the EEA market, if he takes responsibility for CE marking  description of the product (type, identification, use, ), and a copy of the information accompanying the CE marking; NOTE Where some of the information required for the Declaration is already given in the CE marking information, it does not need to be repeated  provisions to which the product conforms (i.e Annex ZA of this EN), and a reference to the ITT report(s) and factory production control records (if appropriate);  particular conditions applicable to the use of the product (e.g provisions for use under certain conditions);  the number of the accompanying factory production control certificate, and FPC records, where applicable;  name of, and position held by, the person empowered to sign the declaration on behalf of the manufacturer or his authorised representative The declaration shall be accompanied by a factory production control certificate, drawn up by the notified body, which shall contain, in addition to the information above, the following:  name and address of the notified body;  the number of the factory production control certificate;  conditions of validity of the certificate, where applicable;  name of, and position held by, the person empowered to sign the certificate In case of products under systems 2+ and (for reaction to fire), under systems 2+ and (for reaction to fire) When compliance with the conditions of this annex is achieved, and once the notified body has drawn up the FPC certificate mentioned below, the manufacturer or his agent established in the EEA shall draw up and retain the EC declaration of conformity, which entitles the manufacturer to affix the CE marking This EC declaration of conformity shall include:  name and address of the manufacturer, or his authorised representative established in the EEA, and the place of production; NOTE The manufacturer may also be the person responsible for placing the product onto the EEA market, if he takes responsibility for CE marking  description of the product (type, identification, use, ), and a copy of the information accompanying the CE marking; NOTE Where some of the information required for the Declaration is already given in the CE marking information, it does not need to be repeated BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E)  provisions to which the product conforms (i.e Annex ZA of this EN), and a reference to the ITT report(s) and factory production control records (if appropriate);  particular conditions applicable to the use of the product (e.g provisions for use under certain conditions);  the number of the accompanying factory production control certificate, and FPC records, where applicable;  name and address of the notified laboratory (only when system applies for reaction to fire);  name of, and position held by, the person empowered to sign the declaration on behalf of the manufacturer or his authorised representative The EC declaration of conformity shall be accompanied by the FPC certificate, drawn up by the notified body, which shall contain, in addition to the information above, the following:  name and address of the notified body;  the number of the factory production control certificate;  conditions of validity of the certificate, where applicable;  name of, and position held by, the person empowered to sign the certificate  name and address of the manufacturer, or his authorised representative established in the EEA, and place of production; NOTE The manufacturer may also be the person responsible for placing the product onto the EEA market, if he takes responsibility for CE marking  description of the product (type, identification, use, ), and a copy of the information accompanying the CE marking; NOTE Where some of the information required for the Declaration is already given in the CE marking information, it does not need to be repeated  provisions to which the product conforms (i.e Annex ZA of this EN), and a reference to the ITT report(s) and factory production control records (if appropriate);  particular conditions applicable to the use of the product (e.g provisions for use under certain conditions);  name of, and position held by, the person empowered to sign the declaration on behalf of the manufacturer or of his authorised representative The above mentioned EC declaration of conformity or the EC certificate of conformity shall be presented in the language or languages accepted in the Member State in which the product is to be used." ZA.3 CE marking and labelling ZA.3.1 General The manufacturer or his authorised representative established within the EEA is responsible for the affixing of the CE marking The CE marking symbol to affix shall be in accordance with Directive 93/68/EC and shall be shown on the EPS block (or when not possible it may be on the accompanying label, the packaging or on the accompanied commercial documents, e.g a delivery note) The following information shall be added to the CE marking symbol: BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E)  identification number of the certification body;  name or identifying mark and registered address of the producer;  the last two digits of the year in which the marking is affixed;  number of the EC factory production control certificate;  reference to this European Standard;  description of the product: generic name, dimensions, etc and intended use;  information on those relevant essential characteristics taken from Table ZA.1;  "No performance determined" for characteristics where this is relevant The "No performance determined" (NPD) option may not be used where the characteristic is subject to a threshold level Otherwise, the NPD option may be used when and where the characteristic, for a given intended use, is not subject to regulatory requirements in the Member State of destination In the following subclauses the conditions are given for the application of CE marking Figure ZA.1 gives the simplified label to affix to the product, containing the minimum set of information and the link to the accompanying document where the other required information are given The minimum set of information to be put directly in the affixed label or in the companying document is given in Figure ZA.1 and Figure ZA.2 ZA.3.2 Simplified label In the case of simplified label the following information shall be added to the CE marking symbol:  name or identifying mark and registered address of the producer;  identification number of the unit (to ensure traceability);  the last two digits of the year in which the marking is affixed;  number of the CE factory production control certificate;  reference to this European Standard The same identification number shall mark, in the accompanying documents, the information related to the unit All other information shall be provided in the accompanying documents Figure ZA.1 gives the simplified label to affix to the product, containing the minimum set of information The other information defined in ZA.3.1 and not given with the simplified label shall be provided with the accompanying documents BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) CE conformity marking consisting of the CE symbol given in Directive 93/68/EEC AnyCo Ltd, PO Bx 21, B-1050 Name or identifying mark and registered address of the producer 45PJ76/02 Identification number and last two digits of the year in which the marking was affixed 0123-CPD-0456 Number of the FPC certificate EN 15037-4 Number of this European Standard Figure ZA.1 — Example of simplified label NOTE For small elements or for product stamping reasons, the size may be reduced by removing reference to EN and/or to FPC certificate ZA.3.3 Information to be provided with the CE marking Figure ZA.2 gives, for a type of EPS blocks for beam-and-block floor systems, an example of the information to be provided with CE marking BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) CE conformity marking consisting of the CE symbol given in Directive 93/68/EEC 123 Identification of the notified body AnyCo Ltd, PO Bx 21, B-1050 Name or identifying mark and registered address of the producer 09 Last two digits of the year in which the marking was affixed 0123-CPD-0456 Number of the FPC certificate EN 15037-4 Beam-and-block floor systems – Part 4: EPS blocks Number and title of European Standard concerned EPS BLOCKS Generic name and intended use Mechanical resistance: Class R1 b Clearance with beams mm Conditions of installation as the clearance with beams or the lateral tightening of the beams Dimensions: Length × Width × Height 000 × 565 × 165 mm Tongue thickness 82 mm Reaction to fire Class F Thermal conductivity 0,036 W/m⋅K Thermal resistance of the floor 2,88 m ⋅K/W For configuration and durability see Technical Information Technical Information: Product Catalogue ABC : 2002 – Clause ii Dangerous substances: see Note below Information on product geometry and material characteristics including detailing (to be adapted to the specific product by the producer) Definition of the compatible beams for the EPS blocks and the inner spacing beams corresponding NOTE example Numerical values are only as NOTE The sketch may be omitted if equivalent information are available in clearly identified Technical Information (product catalogue) referred to Figure ZA.2 — Example of CE marking information !deleted text" BS EN 15037-4:2010+A1:2013 EN 15037-4:2010+A1:2013 (E) Bibliography [1] EN 206-1, Concrete — Part 1: Specification, performance, production and conformity [2] EN 1990, Eurocode — Basis of structural design [3] EN 1992-1-2, Eurocode 2: Design of concrete structures — Part 1-2: General rules — Structural fire design [4] ENV 13670-1, Execution of concrete structures — Part 1: Common [5] EN ISO 6946, Building components and building elements — Thermal resistance and thermal transmittance — Calculation method (ISO 6946:2007) [6] EN ISO 10077-2, Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames (ISO 10077-2:2003) [7] EN ISO 10456, Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values (ISO 10456:2007) [8] EN 1992-1-1, Eurocode 2: Design of concrete structures — Part 1-1: General rules and rules for buildings British Standards Institution (BSI) BSI is the independent national body responsible for preparing British Standards and other standards-related publications, information and services It presents the UK view on standards in Europe and at the international level BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited Revisions Information on standards British Standards and PASs are periodically updated by amendment or revision Users of British Standards and PASs should make sure that they possess the latest amendments or editions It is the constant aim of BSI to improve the quality of our products and services We would be grateful if anyone finding an inaccuracy or ambiguity while using British Standards would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover Similary for PASs, please notify BSI Customer Services Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001 BSI provides a wide range of information on national, European and international standards through its Knowledge Centre BSI offers BSI Subscribing Members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of British Standards and PASs Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: membership@bsigroup.com Tel: +44 (0)20 8996 7669 Fax: +44 (0)20 8996 7001 Email: plus@bsigroup.com Information regarding online access to British Standards and PASs via British Standards Online can be found at www.bsigroup.com/BSOL Further information about British Standards is available on the BSI website at www.bsigroup.com/standards Buying standards You may buy PDF and hard copy versions of standards directly using a credit card from the BSI Shop on the website www.bsigroup.com/shop In addition all orders for BSI, international and foreign standards publications can be addressed to BSI Customer Services Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001 Email: orders@bsigroup.com In response to orders for international standards, BSI will supply the British Standard implementation of the relevant international standard, unless otherwise requested Tel: +44 (0)20 8996 7004 Fax: +44 (0)20 8996 7005 Email: knowledgecentre@bsigroup.com BSI Subscribing Members are kept up to date with standards developments and receive substantial discounts on the purchase price of standards For details of these and other benefits contact Membership Administration Copyright All the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that owns copyright in the information used (such as the international standardization bodies) has formally licensed such information to BSI for commercial publication and use Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained Details and advice can be obtained from the Copyright & Licensing Department Tel: +44 (0)20 8996 7070 Email: copyright@bsigroup.com BSI 389 Chiswick High Road London W4 4AL UK Tel +44 (0)20 8996 9001 Fax +44 (0)20 8996 7001 www.bsigroup.com/standards raising standards worldwide™

Ngày đăng: 14/04/2023, 08:15