1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 13126 11 2008 (2009)

16 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Unknown BS EN 13126 11 2008 ICS 91 190 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BRITISH STANDARD Building hardware — Requirements and test methods for windows and doors h[.]

BRITISH STANDARD Building hardware — Requirements and test methods for windows and doors height windows Part 11: Top projecting reversible hardware ICS 91.190 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BS EN 13126-11:2008 BS EN 13126-11:2008 National foreword This British Standard is the UK implementation of EN 13126-11:2008 It supersedes DD CEN TS 13126-11:2004 which is withdrawn The UK participation in its preparation was entrusted to Technical Committee B/538/4, Building hardware A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2009 © BSI 2009 ISBN 978 580 67206 Amendments/corrigenda issued since publication Date Comments BS EN 13126-11:2008 EUROPEAN STANDARD EN 13126-11 NORME EUROPÉENNE EUROPÄISCHE NORM November 2008 ICS 91.190 Supersedes CEN/TS 13126-11:2004 English Version Building hardware - Requirements and test methods for windows and doors height windows - Part 11: Top projecting reversible hardware Quincaillerie pour le bâtiment - Exigences et méthodes d'essai des ferrures de fenêtres et portes-fenêtres - Partie 11: Ferrures pour ouvrants l'italienne réversibles axe horizontal supérieur Baubeschläge - Beschläge für Fenster und Fenstertüren Anforderungen und Prüfverfahren - Teil 11: Umkehrbeschläge für auskragende SchwingKlappflügelfenster This European Standard was approved by CEN on October 2008 CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG Management Centre: rue de Stassart, 36 © 2008 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members B-1050 Brussels Ref No EN 13126-11:2008: E BS EN 13126-11:2008 EN 13126-11:2008 (E) Contents Page Foreword Scope .5 Normative references Terms and definitions 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 Classification General Category of use (1 – first digit) .6 Durability (2 – second digit) Mass (3 – third digit) Fire resistance (4 – fourth digit) .6 Safety in use (5 – fifth digit) Corrosion resistance (6 – sixth digit) Security (7 – seventh digit) .6 Application (8 – eighth digit) Test sizes – Size limitations (9 – ninth digit) .6 Example of classification for top projecting reversible hardware 5.1 5.2 5.3 5.4 5.5 Requirements General Integrated restrictors .7 Ease of sash movement test Durability test Static load test Test equipment .8 7.1 7.2 7.3 7.4 7.5 Test methods Samples Ease of sash movement test procedure Durability test procedure .9 Static load test procedure .10 Corrosion resistance .10 Annex A (informative) Test method diagrams 11 Annex B (normative) Flow chart of test procedure 12 BS EN 13126-11:2008 EN 13126-11:2008 (E) Foreword This document (EN 13126-11:2008) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2009, and conflicting national standards shall be withdrawn at the latest by May 2009 This document supersedes CEN/TS 13126-11:2004 This European Standard is one of a series of European Standards dedicated to building hardware products A full contribution to the preparation of this European Standard has been made by the European manufacturers´ organization “ARGE” and national standards bodies EN 13126 Building hardware — Requirements and test methods for windows and doors height windows consists of the following parts: Part 1: Requirements common to all types of hardware ) Part 2: Casement fastener handles1 1) Part 3: Manoeuvring fittings for espagnolette bolts/sliding button Part 4: Espagnolette bolts 1) Part 5: Devices that restrict the opening of windows 1) Part 6: Variable geometry stay hinges (with or without a friction system) Part 7: Finger catches Part 8: Tilt&Turn, Tilt-First and Turn-Only hardware 1) Part 9: Pivot hinges Part 10: Arm balancing systems Part 11: Top projecting reversible hardware Part 12: Side projecting reversible hardware Part 13: Sash balances 1) Part 14: Sash fasteners 1) Part 15: Rollers for horizontal sliding and sliding folding windows and doors 1) To be revised, for the time being CEN/TS BS EN 13126-11:2008 EN 13126-11:2008 (E) Part 16: Hardware for Lift&Slide windows and doors Part 17: Hardware for Tilt&Slide windows and doors Part 18: Fan light openers for windows and door height windows Part 19: Sliding Closing Devices (SCD) for windows and door height windows Informative Annex A of EN 13126-1:2006 gives detailed schedules of the elements of components of the 17 first parts of this European Standard Informative Annex B of EN 13126-1:2006 gives schedules of the elements of components used on the 21 types of window opening functions The performance tests incorporated in this European Standard are considered to be reproducible and as such will provide a consistent and objective assessment of the performance of these products throughout CEN Member States According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom BS EN 13126-11:2008 EN 13126-11:2008 (E) Scope This part of EN 13126 specifies the requirements and test methods for durability, strength, security and function of top projecting reversible hardware for windows NOTE This European Standard is applicable to top projecting reversible hardware whether fitted with integral restrictors or not Normative references The following referenced documents are indispensable for the application of this document For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies EN 12519:2004, Windows and pedestrian doors — Terminology EN 13126-1:2006, Building hardware — Requirements and test methods for windows and doors height windows — Part 1: Requirements common to all types of hardware CEN/TS 13126-5, Building hardware, fittings for windows and door height windows — Requirements and test methods — Part 5: Devices that restrict the opening of windows EN 1670, Building hardware — Corrosion resistance — Requirements and test methods ISO 4520:1981, Chromate conversion coatings on electroplated zinc and cadmium coatings Terms and definitions For the purposes of this document, the terms and definitions given in EN 13126-1:2006 and EN 12519:2004 and the following apply NOTE The following terms and definitions apply to windows made of wood, PVC-u, aluminium or steel and their appropriate material combinations 3.1 pivot retainer device (may be integrated onto hinge arm system) fitted to the sash to hold it during rotation on hinge mechanism 3.2 integrated restrictor mechanism that is an integral part of the top projecting reversible hardware that limits the initial opening of the window and may or may not also hold an opening light firmly in the reverse position 3.3 top glider assembly consisting of plate and swivel bracket fitted to the sash, which guides movement in the vertical plane 3.4 top projecting reversible hinge mechanism consisting of sliding rails and moving arms fitted into the frame sides of the window, to support the sash allowing it to open outward, without projecting into the room, and be reversed for cleaning from the inside BS EN 13126-11:2008 EN 13126-11:2008 (E) 4.1 Classification General The classification for top projecting reversible hardware shall be in accordance with the requirements of Clause EN 13126-1:2006 4.2 Category of use (1 – first digit) No marking is required for the category of use in accordance with 4.2 of EN 13126-1:2006 4.3 Durability (2 – second digit) Grades shall be in accordance with 4.3 of EN 13126-1:2006 4.4 Mass (3 – third digit) Grades shall be in accordance with 4.4 of EN 13126-1:2006 4.5 Fire resistance (4 – fourth digit) One grade shall be identified in accordance with 4.5 of EN 13126-1:2006  4.6 grade 0: no requirements Safety in use (5 – fifth digit) One grade shall be identified in accordance with 4.6 of EN 13126-1:2006  4.7 grade 1: hardware shall conform to the requirements of EN 13126-1 and EN 13126-11 Corrosion resistance (6 – sixth digit) Grades shall be in accordance with 4.7 of EN 13126-1:2006 4.8 Security (7 – seventh digit) No marking is required for the category of security in accordance with 4.8 of EN 13126-1:2006 4.9 Application (8 – eighth digit) The eighth digit shows “11” indicating the part of the standard which was used for testing the top turn projecting reversible hardware in accordance with 4.9 of EN 13126-1:2006 4.10 Test sizes – Size limitations (9 – ninth digit) The ninth digit shows the test sizes in accordance with 4.10 of EN 13126-1:2006 as follows: S.R.W 2) in mm / S.R.H 3) in mm 2) S.R.W = sash rebate width 3) S.R.H = sash rebate height BS EN 13126-11:2008 EN 13126-11:2008 (E) EXAMPLE 500 S.R.W × 500 S.R.H The specified size is a test size only It does not relate to the maximum size to which a window may be fabricated For instances where the top projecting reversible hardware is available in a range of module sizes to suit differing window sizes it shall be tested at the size which gives the most severe impact on the hardware, as recommended by the hardware manufacturer This size is then recorded as the ninth digit 4.11 Example of classification for top projecting reversible hardware Table — Example of classification for top projecting reversible hardware - 060 - 11 500/1 500 This denotes Top Hung Projecting Reversible hardware, which has the following: Digit category of use - (no requirements); Digit durability grade (25 000 cycles); Digit mass 60 kg; Digit fire resistance grade (no requirements); Digit safety in use grade 1; Digit corrosion resistance grade 3; Digit security - (no requirements); Digit applicable part tested in accordance with Part 11 of this standard; Digit test sizes S.R.W 5.1 1) 2) = 500 mm, S.R.H = 500 mm Requirements General The requirements for top projecting reversible hardware shall be in accordance with Clause of EN 13126-1:2006 5.2 Integrated restrictors Where top projecting reversible hardware is fitted with an integrated restrictor the hardware shall be tested in accordance with CEN/TS 13126-5 5.3 Ease of sash movement test The test specified in 7.2 shall be used to determine the forces required to operate the hardware is appropriate for the intended use On completion of the ease of sash movement test in accordance with 7.2 BS EN 13126-11:2008 EN 13126-11:2008 (E)  Force required to initiate movement in either the opening or closing direction shall not have exceeded 100 N  Force required to sustain movement in either the opening or closing direction shall not have exceeded 100 N 5.4 Durability test The test specified in 7.3 shall be used to ensure the hardware is capable of continued operation after cycling in accordance with grades specified in 7.3, with regard given to normal maintenance On completion of the durability test in accordance with 7.3  5.5 Top projecting reversible hardware shall continue to function normally Static load test The test specified in 7.4 shall be used to ensure the mechanical strength of the hardware is appropriate for its intended use On completion of the static load test in accordance with 7.4  Top projecting reversible hardware shall continue to function normally  Measured clearance gap between sash and frame shall not have increased by more than mm from the measured clearance gap prior to the test commencing Test equipment The top projecting reversible hardware shall be installed in the test specimen for testing as in Clause of EN 13126-1:2006, and in accordance with the manufacturers fixing instructions NOTE The hardware manufacturer should provide test specimens for the testing institute A drawing of the profile cross-section with relevant information should be enclosed in the test application, which also contains the necessary hardware installation information for the windows The test shall be conducted on a test rig which corresponds in function and shape to the window for which the hardware was intended The hardware tested shall conform to the manufacturers’ recommendation for size and mass of the test specimen 7.1 Test methods Samples Three samples shall be tested in accordance with this European Standard sample A – performance tests; sample B – corrosion test; sample C – retained for reference control NOTE Sample B should only be necessary if no test report can be supplied by the manufacturer regarding the testing of the hardware component or set in accordance with EN 1670 BS EN 13126-11:2008 EN 13126-11:2008 (E) NOTE Sample C should be retained by the test institute for the duration of the validity of the test report NOTE All window fastening devices should not be engaged when measuring the clearance gap between sash and frame 7.2 Ease of sash movement test procedure All integrated or additional restrictors shall be disabled before any testing commences With the sash in the fully closed position record the amount of force in Newtons required to initiate movement of the sash Return the sash to the fully closed position and record the amount of force in Newtons required to sustain uniform movement of sash to between 200 mm and 300 mm from the closed position With the sash at an open position of between 200 mm and 300 mm from the closed position record the amount of force in Newtons required to initiate movement of the sash Return the sash to an open position of between 200 mm and 300 mm from the closed position and record the amount of force in Newtons required to sustain uniform movement of sash to the closed position The force shall be applied in the direction that would be used for the conventional opening and closing of the sash The hardware shall conform to the acceptance criteria of 8.4 of EN 13126-1:2006 and 5.3 of this European Standard 7.3 Durability test procedure All integrated or additional restrictors shall be disabled before any testing commences + 25 Cycle the window in accordance with one of the following grades at the rate of 250  grade 3: 10 000 cycles (+ %) cycles;  grade 4: 15 000 cycles (+ %) cycles;  grade 5: 25 000 cycles (+ %) cycles cycles/h The cycle test of the window is performed by repeating the following stages (see Figure A.1) Stage Cycle the sash from the fully closed position to an open position of between 25° and 40° for a total of 500 + % cycles Stage Cycle the sash from an open position of up to 25° through the maximum opening position and into a reverse position of a minimum of 155° for a total of 500 + % cycles in accordance with Clause of EN 13126-1:2006 NOTE All moving parts requiring lubrication may be lubricated unless the manufacturer has specified the hardware as maintenance free in accordance with hardware manufacturers’ instructions Return the window to the closed position The hardware shall conform to the acceptance criteria of 8.4 of EN 13126-1:2006 and 5.4 of this European Standard BS EN 13126-11:2008 EN 13126-11:2008 (E) 7.4 Static load test procedure Measure and record the clearance gap between the sash and frame at the bottom of the window Measurements shall be taken at two points; at each corner of the sash at no more than 50 mm from each side, and along the opening edge (see Figure A.2) Open the sash to 90° ± 2° Secure the top of the sash in this position preventing further sash movement (see Figure A.3)  + 25 Apply a vertical downward force of 500 N + 25 N in increments of 100 N N at the centre of +5 the bottom of the sash Maintain force of 500 N for 60 s s Return the window to the closed position Measure and record the clearance gap between the sash and the frame at the bottom of the window Measurements shall be taken at the same position as used prior to the test commencing The hardware shall conform to the acceptance criteria of 8.4 of EN 13126-1:2006 and 5.5 of this European Standard 7.5 Corrosion resistance NOTE A test should only be necessary if no test report can be supplied by the manufacturer in accordance with EN 1670 All corrosion tests shall be on original new samples For Zinc galvanized surfaces on iron or steel the specified thickness of 12 µ (class 3) or 16 µ (class 4) is not necessary if other surface protection methods are used to conform to the requirements (minimum time to formation of white corrosion products) of ISO 4520:1981 (µ = micrometre) Unless a test report can be provided by the manufacturer the hardware shall be tested in accordance with EN 1670 NOTE The evaluation of the corrosion resistance is limited to the essential areas (as a rule, the visible surfaces of the installed hardware) The following are exempt from the corrosion resistance evaluation:  rivet locations;  locations of later processing (for example: cleaved surfaces that result from cropping the hardware components, millings);  non surface-treated parts/surfaces, provided they are not in the visible vicinity of the hardware (for example: screw guide-holes made of zinc die-cast);  welding joints and their immediate surroundings 10 BS EN 13126-11:2008 EN 13126-11:2008 (E) Annex A (informative) Test method diagrams 3 M Figure A.1 — Durability test rig 4 Figure A.2 — Durability test rig - plan view Key 500 N width height specimen measured clearance dual action motor stop block bottom rail M motor Figure A.3 — Static load test 11 BS EN 13126-11:2008 EN 13126-11:2008 (E) Annex B (normative) Flow chart of test procedure Start Sample A Sample B Sample C 7.2 Ease of Sash Movement 7.5 Corrosion Resistance Retain for reference control 7.3 Durability Test 7.4 Static Load Test 7.2 Ease of Sash Movement Finish 12 BS EN 13126-11:2008 This page has been intentionally left blank BS EN 13126-11:2008 BSI - British Standards Institution BSI is the independent national body responsible for preparing British Standards It presents the UK view on standards in Europe and at the international level It is incorporated by Royal Charter Revisions British Standards are updated by amendment or revision Users of British Standards should make sure that they possess the latest amendments or editions It is the constant aim of BSI to improve the quality of our products and services We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover Tel: +44 (0)20 8996 9000 Fax: +44 (0)20 8996 7400 BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards Buying standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001 Email: orders@bsigroup.com You may also buy directly using a debit/credit card from the BSI Shop on the Website http://www.bsigroup.com/shop In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested Information on standards BSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service Various BSI electronic information services are also available which give details on all its products and services Contact Information Centre Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: info@bsigroup.com Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards For details of these and other benefits contact Membership Administration Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: membership@bsigroup.com Information regarding online access to British Standards via British Standards Online can be found at http://www.bsigroup.com/BSOL Further information about BSI is available on the BSI website at http:// www.bsigroup.com Copyright BSI Group Headquarters 389 Chiswick High Road, London, W4 4AL, UK Tel +44 (0)20 8996 9001 Fax +44 (0)20 8996 7001 www.bsigroup.com/ standards Copyright subsists in all BSI publications BSI also holds the copyright, in the UK, of the publications of the international standardization bodies Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained Details and advice can be obtained from the Copyright and Licensing Manager Tel: +44 (0)20 8996 7070 Email: copyright@bsigroup.com

Ngày đăng: 14/04/2023, 00:56

Xem thêm:

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN