1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 12566 7 2016

52 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

BS EN 12566-7:2016 BSI Standards Publication Small wastewater treatment systems for up to 50 PT Part 7: Prefabricated tertiary treatment units BS EN 12566-7:2016 BRITISH STANDARD National foreword This British Standard is the UK implementation of EN 12566-7:2016 It supersedes BS EN 12566-7:2013 which is withdrawn The UK participation in its preparation was entrusted to Technical Committee B/505, Wastewater engineering A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © The British Standards Institution 2016 Published by BSI Standards Limited 2016 ISBN 978 580 91477 ICS 13.060.30 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2016 Amendments/corrigenda issued since publication Date Text affected BS EN 12566-7:2016 EN 12566-7 EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM August 2016 ICS 13.060.30 Supersedes EN 12566-7:2013 English Version Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units Petites installations de traitement des eaux usées jusqu'à 50 PTE - Partie 7: Unités préfabriquées de traitement tertiaire Kleinkläranlagen für bis zu 50 EW - Teil 7: Im Werk vorgefertigte Einheiten für eine dritte Reinigungsstufe This European Standard was approved by CEN on 25 June 2016 CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels © 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members Ref No EN 12566-7:2016 E BS EN 12566-7:2016 EN 12566-7:2016 (E) Contents Page European foreword Scope Normative references 3.1 3.2 Terms, definitions, symbols and abbreviated terms Terms and definitions Symbols and abbreviated terms 4.1 4.1.1 4.1.2 4.1.3 4.1.4 4.2 4.3 4.4 4.5 4.6 4.6.1 4.6.2 4.7 4.7.1 4.7.2 4.7.3 4.8 Product characteristics Design General Overall dimensions Inlets, outlets, internal pipework and connections Access Load bearing capacity Tertiary treatment efficiency Watertightness 10 Power consumption 10 Durability 10 General 10 Concrete, steel, PVC-U, PE, GRP, PDCPD and flexible sheets 10 Reaction to fire 10 General 10 Units classified as Class A1 without the need for testing 11 Units classified according to the test results 11 Dangerous substances 11 5.1 5.1.1 5.1.2 5.1.3 5.2 5.3 5.4 Testing, assessment and sampling 12 Load bearing capacity 12 Generals 12 Load bearing capacity determined by calculation 12 Load bearing capacity determined by testing 13 Tertiary treatment efficiency 15 Watertightness 15 Power consumption 15 6.1 6.2 6.2.1 6.2.2 6.2.3 6.2.4 6.2.5 6.3 6.3.1 6.3.2 6.3.3 6.3.4 6.3.5 6.3.6 Assessment and verification of constancy of performance – AVCP 15 General 15 Type testing 16 General 16 Test samples, testing and compliance criteria 16 Test reports 18 Shared other party results 18 Cascading determination of the product type results 19 Factory production control 20 General 20 Requirements 20 Product specific requirements 23 Initial inspection of factory and of FPC 23 Continuous surveillance of FPC 24 Procedure for modifications 24 BS EN 12566-7:2016 EN 12566-7:2016 (E) 6.3.7 One-off products, pre-production products (e.g prototypes) and products produced in very low quantity 24 Nominal designation 25 8.1 8.2 8.3 8.4 Marking, labelling and packaging 25 Marking 25 Technical information accompanying the unit 26 Installation instructions 27 Operation manual 27 Annex A (normative) Tertiary treatment efficiency test procedure 29 A.1 Preliminary requirements 29 A.1.1 General 29 A.1.2 Installation and commissioning 29 A.1.3 Operation procedures during testing 29 A.1.4 Data to be monitored 29 A.2 Test procedure 30 A.2.1 Time for establishment 30 A.2.2 Influent characteristics 30 A.2.3 Daily flow pattern for testing 30 A.2.4 Test procedure 30 A.2.4.1 General 30 A.2.4.2 Overload 31 A.2.4.3 Power breakdown/Machine breakdown 31 A.2.4.4 Power consumption 31 A.2.5 Influent and effluent sampling 32 A.3 Sample analysis 32 A.4 Test report 32 Annex B (normative) Definition of processes 33 Annex C (informative) Analysis method 34 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation 35 ZA.1 Scope and relevant characteristics 35 ZA.2 Procedure of attestation of conformity of prefabricated tertiary treatment unit 36 ZA.2.1 System(s) of AVCP 36 ZA.2.2 Declaration of performance (DoP) 39 ZA.2.2.1 General 39 ZA.2.2.2 Content 40 ZA.2.2.3 Example of DoP 41 ZA.3 CE marking and labelling 43 Bibliography 46 BS EN 12566-7:2016 EN 12566-7:2016 (E) European foreword This document (EN 12566-7:2016) has been prepared by Technical Committee CEN/TC 165 “Wastewater engineering”, the secretariat of which is held by DIN This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2017, and conflicting national standards shall be withdrawn at the latest by May 2018 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights This document supersedes EN 12566-7:2013 This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s) For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document The differences between this version and EN 12566-7:2013 are mainly editorial changes according to the Construction Product Regulation (CPR) and declaration of power consumption and desludging during treatment efficiency test The standard series EN 12566 “Small wastewater treatment systems for up to 50 PT” contains the following parts (see Figure 1): — Part 1: Prefabricated septic tanks; — Part 3: Packaged and/or site assembled domestic wastewater treatment plants; — Part 4: Septic tanks assembled in situ from prefabricated kits; — Part 6: Prefabricated treatment unit used for septic tank effluent; — Part 7: Prefabricated tertiary treatment unit (this document) For filtration systems, CEN/TC 165 decided to publish the following CEN Technical reports, which are considered as Code of practices and not specify treatment requirements: — Part 2: Soil infiltration systems; — Part 5: Pre-treated Effluent Filtration systems BS EN 12566-7:2016 EN 12566-7:2016 (E) Key A domestic wastewater prefabricated septic tank C treated infiltrated effluent packaged and/or site assembled domestic wastewater treatment plant B D E septic tank effluent treated wastewater tertiary wastewater soil infiltration system septic tank assembled in situ from prefabricated kit treated pre-treated effluent filtration system prefabricated treatment unit used for septic tank effluent prefabricated tertiary treatment unit National regulations may specify different arrangements between the products described in the standard series EN 12566 Figure — Scheme related to the arrangement of the parts of EN 12566 According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom BS EN 12566-7:2016 EN 12566-7:2016 (E) Scope This European Standard specifies requirements, test methods, the marking and evaluation of conformity for a packaged and/or site assembled tertiary treatment unit (see Figure 1) It applies for tertiary treatment units that are placed on the market as complete units used for the tertiary treatment of domestic wastewater by biological, physical, chemical, electrical processes and coming from: a) units in accordance with EN 12566-3 or EN 12566-6; b) installations designed and constructed in accordance with CEN/TR 12566-5 Equivalent secondary treated effluent may come from existing systems Package and/or site assembled tertiary treatment units according to this standard consist of one or more watertight tanks without any direct infiltration into the ground, made of concrete, corrosion resistant or coated steel, un-plasticised poly-vinyl chloride (PVC-U), polyethylene (PE), glass reinforced thermosetting plastics (GRP) based on polyester resin (UP) (GRP-UP), polypropylene (PP), polydicyclopentadiene (PDCPD) and flexible sheets (HDPE, PP, PVE and EPDM) This standard applies to tertiary treatment units for use above ground (outside the building) or buried in the ground where no vehicle loads are applied to the unit This standard does not apply to tertiary treatment systems forming part of units covered by EN 12566-3 and EN 12566-6 This standard does not cover the systems for microorganism reduction Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies EN 12566-3:2016, Small wastewater treatment systems for up to 50 PT — Part 3: Packaged and/or site assembled domestic wastewater treatment plants CEN/TR 12566-5, Small wastewater treatment systems up to 50 PT — Part 5: Pre-treated Effluent Filtration systems EN 12566-6:2016, Small wastewater treatment systems for up to 50 PT — Part 6: Prefabricated treatment units for septic tank effluent EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire tests EN 16323:2014, Glossary of wastewater engineering terms Terms, definitions, symbols and abbreviated terms 3.1 Terms and definitions For the purposes of this document, the terms and definitions given in EN 12566-3:2016, EN 12566-6:2016, EN 16323:2014 and the following apply BS EN 12566-7:2016 EN 12566-7:2016 (E) 3.1.1 tertiary treatment additional treatment process which results in further purification than that obtained by applying primary and secondary treatment Note to entry: It is recommended that the expression for the treatment, e.g nitrogen removal, phosphorus removal, polishing effects, suspended solid removal, is used since in some case the tertiary treatment can also be integrated in the secondary treatment 3.1.2 packaged unit prefabricated factory-built unit 3.1.3 site assembled unit unit composed of prefabricated components assembled on site coming from one manufacturer 3.1.4 biological processes processes in which the treatment is mainly carried out by micro-organism activity 3.1.5 physical processes processes in which the treatment is mainly carried out by using the physical properties of a media 3.1.6 chemical processes processes in which the treatment is mainly carried out by the addition of chemical agents 3.1.7 electrical processes processes in which the treatment is mainly carried out by the use of electricity 3.1.8 product family group of products in which, for the purpose of evaluation, the selected property(s) is/are similar for all products within the group Note to entry: The definition of family takes into account at least similar shape, equipment, materials and conditions of end use and ensures the minimum hydraulic efficiency and minimum structural behaviour for all the products in the range Note to entry: The minimum level of performance (hydraulic efficiency and structural behaviour) are given by the test carried out on one model of the family 3.1.9 tertiary treatment retrofit unit tertiary treatment unit installed within an existing package and/or site assembled domestic wastewater treatment plant in accordance with EN 12566-3, or a secondary treatment unit in accordance with EN 12566-6 or a pre-treated effluent filtration system in accordance with CEN/TR 12566-5 Note to entry: Where such a retrofit unit affects the declared performance of EN 12566–3 or EN 12566–6 unit in which it is installed, then the overall unit should be tested for its conformity with the relevant standard BS EN 12566-7:2016 EN 12566-7:2016 (E) 3.1.10 nominal designation expressed as an integer giving the maximum number of population equivalent appropriate to the plant 3.2 Symbols and abbreviated terms The following symbols and abbreviations are used in this standard: BOD5 (or BOD7) Biochemical oxygen demand at days (or days) Total N Total nitrogen COD SS Total P TOC PP PDCPD HDPE PVC EPDM PE Chemical oxygen demand Suspended solids Total phosphorus Total organic carbon Polypropylene Polydicyclopentadiene High Density Polyethylene Polyvinyl Chloride Ethylene Propylene Diene Monomer Polyethylene Product characteristics 4.1 Design 4.1.1 General Tertiary treatment units shall be designed to be structurally stable with the expected loads for the intended use In addition, the units shall be durable, watertight and corrosion resistant Where electrical, mechanical or hydraulic malfunction of the unit could lead to any failure, it shall be provided with an alarm to indicate such failure The functionality of the alarm shall be verified as referenced in Table A.2 4.1.2 Overall dimensions The overall dimensions of the prefabricated tertiary treatment unit (i.e height, width, length, diameters, etc.) shall be measured and declared together with a tolerance Assessment of overall dimensions shall be done by measurement with accuracy of ± 0,5 % of the dimension 4.1.3 Inlets, outlets, internal pipework and connections The nominal diameters for inlet and outlet pipework of the prefabricated tertiary treatment unit shall be declared in the technical documentation The hydraulic design of the unit, the internal pipework and the connections shall ensure that no accidental back-flows, blockage or surcharging occur during normal operation of the plant Inlet and outlet pipes shall be compatible with standardised pipe systems BS EN 12566-7:2016 EN 12566-7:2016 (E) − nominal hydraulic daily flow (QN) − maximum flow hydraulic Release of substance dangerous Watertightness Crushing resistance and/or maximum load deformation as: - Designated according to Clause and expressed in cubic metres of secondarily treated effluent per day (m3/d) 4.4 - Tested according to 4.4a and EN 12566–3:2016, Annex A, and expressed as “Pass” or “Fail” 4.8 - Designated according to Clause and expressed in cubic metres per unit of time As relevant, according to 4.8 a) load bearing capacity 4.2 - Durability 4.6 - b) c) Calculated according to 5.1.2 and EN 12566-3:2016, Annex D; or Tested according to Annex C; and Expressed as maximum allowed height of backfill (m) and possibility to install the plant in wet or dry site, expressed as WET with the indication of the maximum height of the water table measured from the base of the plant or DRY Tested according to 4.5.2 to 4.5.9 (as appropriate) of EN 12566-3:2016 and expressed as “Pass” or “Fail” The declaration of the product performance related to certain essential characteristics is not required in those Member States (MS) where there are no regulatory requirements on these essential characteristics for the intended use of the product In this case, manufacturers placing their products on the market of these MS are not obliged to determine nor declare the performance of their products with regard to these essential characteristics and the option “No performance determined” (NPD) in the information accompanying the CE marking and in the declaration of performance (see ZA.3) may be used for those essential characteristics ZA.2 Procedure of attestation of conformity of prefabricated tertiary treatment unit ZA.2.1 System(s) of AVCP The AVCP system(s) of prefabricated tertiary treatment unit indicated in Table ZA.1, established by EC Decision(s) 97/464/EC of 27 June 1997 (OJEU L198 of 25.7.1997) as amended by EC decision 2004/663/EC of 20 September 2004 (OJEU L302 of 29.9.2004) is shown in Table ZA.2 for the indicated intended use(s) and relevant level(s) or class(es) of performance 36 BS EN 12566-7:2016 EN 12566-7:2016 (E) Table ZA.2 — System(s) of AVCP Product Intended use Level(s) or class(es) Attestation of conformity systems Kits and elements for wastewater treatment plant To be used outside buildings for faecal water and organic effluent - A1*, A2*, B*, C* ––––– ––––––- (A1 to E)***, F For all use(s) when subject to regulations on reaction to fire A1**, A2**, B**, C**, D, E System 1: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.2 System 3: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.4 System 4: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.5 * Products/ materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g an addition of fire retardants or a limiting of organic material) ** Products/ materials not covered by footnote (*) *** Products/ materials that not require to be tested for reaction to fire (e.g Products/materials of class A1 according to the Decision 96/603/EC, as amended).*** Products/materials that not require to be tested for reaction to fire (e.g products/materials of class A1 according to the Decision 96/603/EC, as amended) NOTE Tertiary treatment units belong to the family of products indicated under product in Table ZA.2 The AVCP of the prefabricated tertiary treatment unit in Table ZA.1 shall be according to the AVCP procedures indicated in Table(s) ZA.3 to ZA.5 resulting from application of the clauses of this or other European Standard indicated therein The content of tasks of the notified body shall be limited to those essential characteristics as provided for, if any, in Annex III of the relevant mandate and to those that the manufacturer intends to declare 37 BS EN 12566-7:2016 EN 12566-7:2016 (E) Table ZA.3 — Assignment of evaluation of AVCP tasks for prefabricated tertiary treatment units under system a Tasks Content of the task AVCP clauses to apply Factory production All essential characteristics of Table ZA.1 relevant for 6.3.1, 6.3.2, 6.3.3, control (FPC) the intended use which are declared 6.3.6, 6.3.7 Tasks for the Further testing of samples taken at manufacturer factory according to the prescribed test plan Reaction to fire 6.3 Determination of the product-type on the basis of type testing (based on sampling All essential characteristics of Table ZA.1 relevant for carried out by the the intended use which are declared except reaction to 6.2 manufacturer), type fire calculation, tabulated Task for the values or descriptive notified testing documentation of the product laboratory a 38 Initial inspection of Reaction to fire factory and of FPC 6.3 Reaction to fire 6.3 Continuous surveillance, assessment and evaluation of FPC For products covered by footnote (*) of Table ZA.2 BS EN 12566-7:2016 EN 12566-7:2016 (E) Table ZA.4 — Assignment of AVCP tasks for prefabricated tertiary treatment units under system 3a Tasks Content of the task AVCP clauses to apply Tasks for the Factory production manufacturer control (FPC) All essential characteristics of Table ZA.1 relevant for 6.3 the intended use which are declared Tasks for a notified testing laboratory All essential characteristics of Table ZA.1 relevant for 6.2 the intended use which are declared a Determination of the product-type on the basis of type testing (based on sampling carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the product For products covered by footnote (**) of Table ZA.2 Table ZA.5 — Assignment of AVCP tasks for prefabricated tertiary treatment units under system 4a Tasks Factory production control (FPC) Determination of the product-type on the basis of type testing Tasks for the (based on sampling manufacturer carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the product a Content of the task AVCP clauses to apply All essential characteristics of Table ZA.1 relevant for 6.3 the intended use which are declared All essential characteristics of Table ZA.1 relevant for 6.2 the intended use which are declared For products covered by footnote (***) of Table ZA.2 ZA.2.2 Declaration of performance (DoP) ZA.2.2.1 General The manufacturer draws up the DoP and affixes the CE marking on the basis of the different AVCP systems set out in Annex V of the Regulation (EU) No 305/2011: In case of products under system — the factory production control and further testing of samples taken at the factory according to the prescribed test plan, carried out by the manufacturer; and — the certificate of constancy of performance issued by the notified product certification body on the basis of determination of the product type on the basis of type testing (including sampling), type calculation, tabulated values or descriptive documentation of the product; initial inspection of the 39 BS EN 12566-7:2016 EN 12566-7:2016 (E) manufacturing plant and of factory production control and continuous surveillance, assessment and evaluation of factory production control In case of products under system — the factory production control carried out by the manufacturer; and — the determination of the product-type on the basis of type testing (based on sampling carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the product, carried out by the notified testing laboratory In case of products under system — the factory production control carried out by the manufacturer; — the determination by the manufacturer of the product-type on the basis of type testing, type calculation, tabulated values or descriptive documentation of the product ZA.2.2.2 Content The model of the DoP is provided in Regulation (EU) No 574/2014 According to this Regulation, the DoP shall contain, in particular, the following information: — the reference of the product-type for which the declaration of performance has been drawn up; — the AVCP system or systems of the construction product, as set out in Annex V of the CPR; — the reference number and date of issue of the harmonized standard which has been used for the assessment of each essential characteristic; — where applicable, the reference number of the Specific Technical Documentation used and the requirements with which the manufacturer claims the product complies The DoP shall in addition contain: a) the intended use or uses for the construction product, in accordance with the applicable harmonized technical specification; b) the list of essential characteristics, as determined in the harmonized technical specification for the declared intended use or uses; c) the performance of at least one of the essential characteristics of the construction product, relevant for the declared intended use or uses; d) where applicable, the performance of the construction product, by levels or classes, or in a description, if necessary based on a calculation in relation to its essential characteristics determined in accordance with the Commission determination regarding those essential characteristics for which the manufacturer shall declare the performance of the product when it is placed on the market or the Commission determination regarding threshold levels for the performance in relation to the essential characteristics to be declared e) the performance of those essential characteristics of the construction product which are related to the intended use or uses, taking into consideration the provisions in relation to the intended use or uses where the manufacturer intends the product to be made available on the market; f) 40 for the listed essential characteristics for which no performance is declared, the letters “NPD” (No Performance Determined) BS EN 12566-7:2016 EN 12566-7:2016 (E) Regarding the supply of the DoP, article of the Regulation (EU) No 305/2011 applies The information referred to in Article 31 or, as the case may be, in Article 33 of Regulation (EC) No 1907/2006, (REACH) shall be provided together with the DoP ZA.2.2.3 Example of DoP The following gives an example of a filled-in DoP for prefabricated tertiary treatment units DECLARATION OF PERFORMANCE No 0012014-09-30 Unique identification code of the product-type: Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11: prefabricated tertiary treatment unit BWV 777 (concrete) BWV 777 from to 50 PT Intended use or uses of the construction product, in accordance with the applicable harmonized technical specification, as foreseen by the manufacturer: Name, registered trade name or registered trade mark and contact address of the manufacturer as required under Article 11: Treatment of secondarily treated effluent in small wastewater treatment systems for population up to 50 PT a AnyCo SA, PO Box 21 B-1050 Brussels, Belgium Tel +32987654321 Email: anyco.sa@provider.be Where applicable, name and contact address of the authorized representative whose mandate covers the tasks specified in Article 12: Anyone Ltd Flower Str 24 West Hamfordshire UK-589645 United Kingdom Tel +44987654321 e-mail: anyone.ltd@provider.uk 41 BS EN 12566-7:2016 EN 12566-7:2016 (E) System or systems of assessment and verification of constancy of performance of the construction product as set out in CPR, Annex V: System for all essential characteristics except reaction to fire System for reaction to fire 42 In case of the declaration of performance concerning a construction product covered by a harmonized standard: Notified body number 0001 performed product type testing under system and issued test report 12345/2014 No European Technical Assessment has been issued for this product BS EN 12566-7:2016 EN 12566-7:2016 (E) Declared performance Essential characteristics Reaction to fire Effectiveness of treatment expressed as: Tertiary treatment efficiency ratios for Phosphorus removal at — — Class A1 EN 12566–7:2016 0,05 kg/d Tested phosphorus load 0,02 kg/d Treatment capacity (Nominal designation) Nominal hydraulic daily flow Maximum hydraulic flow From to 50 PT 1,5 m3/d 0,7 m3/15 Number of desludging during CE test Power consumption 0,2 kWh/d Watertightness Pass Crushing resistance Durability Harmonized technical specification 80 % Tested organic daily load BOD5 Load bearing capacity Performance Height of backfill: 0,5 m WET: 1,20 m Release of dangerous substance Pass NPD 10 The performance of the product identified in points and is in conformity with the declared performance in point This declaration of performance is issued under the sole responsibility of the manufacturer identified in point Signed for and on behalf of the manufacturer by: ……………………………………………………………………………………………………………………………… (name and function) ………………………………… …………… ………………………………… …………… (place and date of issue) (signature) ZA.3 CE marking and labelling The CE marking symbol shall be in accordance with the general principles set out in Article 30 of Regulation (EC) No 765/2008 and shall be affixed visibly, legibly and indelibly: — to the prefabricated tertiary treatment units; or — to a label attached to it Where this is not possible or not warranted on account of the nature of the product, it shall be affixed: 43 BS EN 12566-7:2016 EN 12566-7:2016 (E) — to the packaging; or — to the accompanying documents The CE marking shall be followed by: — the last two digits of the year in which it was first affixed; — the name and the registered address of the manufacturer, or the identifying mark allowing identification of the name and address of the manufacturer easily and without any ambiguity; — the unique identification code of the product-type; — the reference number of the declaration of performance; — the level or class of the performance declared; — the dated reference to the harmonized technical specification applied as it appears in OJEU; — the identification number of the notified body; — the intended use as laid down in the harmonized technical specification applied The CE marking shall be affixed before the construction product is placed on the market It may be followed by a pictogram or any other mark notably indicating a special risk or use Figure ZA.1 gives an example of the information related to products subject to AVCP under system (all characteristics except reaction to fire) and (for reaction to fire) 44 BS EN 12566-7:2016 EN 12566-7:2016 (E) “CE marking, consisting of the “CE”-symbol Identification number of the notified test laboratory 9876 Any Co Ltd, P.O Box 21, B–1050 16 0012014–09–30 EN 12566–7:2016 prefabricated tertiary treatment unit — Product’s reference code: “BWV 777” — Material: CONCRETE Effectiveness of treatment: Treatment efficiency Phosphorus removal at — — for Tested organic daily load BOD5 Tested phosphorus load Number of desludging during CE test Power consumption Treatment capacity (nominal designation): 0,05 kg/d 0,02 kg/d 0,2 kWh/d Maximum hydraulic flow Watertightness: (water test) Pass — Load bearing capacity Durability Reaction to fire Release of substances dangerous No of European Standard applied, as referenced in OJEU Unique identification code of the product-type Intended use of the product as laid down in the European Standard applied Level or class of the performance declared 80 % PT Crushing resistance: name and the registered address of the manufacturer, or identifying mark Last two digits of the year in which the marking was first affixed Reference number of the DoP 0,7m3/15 Height of backfill 0,5 m WET 0,8 m Pass A1 NPD Figure ZA.1 — Example CE marking information of products under AVCP system (all characteristics except reaction to fire) and (reaction to fire) 45 BS EN 12566-7:2016 EN 12566-7:2016 (E) Bibliography [1] EN 476, General requirements for components used in drains and sewers [3] EN 1899-1, Water quality — Determination of biochemical oxygen demand after n days (BODn) — Part 1: Dilution and seeding method with allylthiourea addition (ISO 5815:1989, modified) [2] [4] [5] [6] [7] [8] EN 872, Water quality — Determination of suspended solids — Method by filtration through glass fibre filters EN 12260, Water quality — Determination of nitrogen — Determination of bound nitrogen (TNb), following oxidation to nitrogen oxides EN 25663, Water quality — Determination of Kjeldahl nitrogen — Method after mineralization with selenium (ISO 5663) EN ISO 11905-1, Water quality — Determination of nitrogen — Part 1: Method using oxidative digestion with peroxodisulfate (ISO 11905-1) EN ISO 6878, Water quality — Determination of phosphorus — Ammonium molybdate spectrometric method (ISO 6878) EN ISO 9001, Quality management systems — Requirements (ISO 9001) [9] EN ISO 10304-1, Water quality — Determination of dissolved anions by liquid chromatography of ions — Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate (ISO 10304-1) [10] EN ISO 11732, Water quality — Determination of ammonium nitrogen — Method by flow analysis (CFA and FIA) and spectrometric detection (ISO 11732) [11] [12] [13] [14] [15] EN ISO 11885, Water quality — Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES) (ISO 11885) EN ISO 15681-2, Water quality — Determination of orthophosphate and total phosphorus contents by flow analysis (FIA and CFA) — Part 2: Method by continuous flow analysis (CFA) (ISO 15681-2) EN ISO 13395, Water quality — Determination of nitrite nitrogen and nitrate nitrogen and the sum of both by flow analysis (CFA and FIA) and spectrometric detection (ISO 13395) EN ISO 14911, Water quality — Determination of dissolved Li+, Na+, NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ using ion chromatography — Method for water and waste water (ISO 14911) ISO 5664, Water quality — Determination of ammonium — Distillation and titration method [16] ISO 6060, Water quality — Determination of the chemical oxygen demand [18] ISO 7150-1, Water quality — Determination of ammonium — Part 1: Manual spectrometric method [17] 46 ISO 6778, Water quality — Determination of ammonium — Potentiometric method BS EN 12566-7:2016 EN 12566-7:2016 (E) [19] [20] [21] ISO 15705, Water quality — Determination of the chemical oxygen demand index (ST-COD) — Small-scale sealed-tube method EN 1992-1-1, Eurocode 2: Design of concrete structures — Part 1-1: General rules and rules for buildings EN 1993-1-1, Eurocode 3: Design of steel structures — Part 1-1: General rules and rules for buildings 47 This page deliberately left blank This page deliberately left blank NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW British Standards Institution (BSI) BSI is the national body responsible for preparing British Standards and other standards-related publications, information and services BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited About us Reproducing extracts We bring together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions For permission to reproduce content from BSI publications contact the BSI Copyright & Licensing team The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process Organizations of all sizes and across all sectors choose standards to help them achieve their goals Information on standards We can provide you with the knowledge that your organization needs to succeed Find out more about British Standards by visiting our website at bsigroup.com/standards or contacting our Customer Services team or Knowledge Centre Buying standards You can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at bsigroup.com/shop, where hard copies can also be purchased If you need international and foreign standards from other Standards Development Organizations, hard copies can be ordered from our Customer Services team Copyright in BSI publications All the content in BSI publications, including British Standards, is the property of and copyrighted by BSI or some person or entity that owns copyright in the information used (such as the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use Save for the provisions below, you may not transfer, share or disseminate any portion of the standard to any other person You may not adapt, distribute, commercially exploit, or publicly display the standard or any portion thereof in any manner whatsoever without BSI’s prior written consent Storing and using standards Standards purchased in soft copy format: • A British Standard purchased in soft copy format is licensed to a sole named user for personal or internal company use only • The standard may be stored on more than device provided that it is accessible by the sole named user only and that only copy is accessed at any one time • A single paper copy may be printed for personal or internal company use only Standards purchased in hard copy format: • A British Standard purchased in hard copy format is for personal or internal company use only • It may not be further reproduced – in any format – to create an additional copy This includes scanning of the document If you need more than copy of the document, or if you wish to share the document on an internal network, you can save money by choosing a subscription product (see ‘Subscriptions’) Subscriptions Our range of subscription services are designed to make using standards easier for you For further information on our subscription products go to bsigroup.com/subscriptions With British Standards Online (BSOL) you’ll have instant access to over 55,000 British and adopted European and international standards from your desktop It’s available 24/7 and is refreshed daily so you’ll always be up to date You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single copy and subscription format, by becoming a BSI Subscribing Member PLUS is an updating service exclusive to BSI Subscribing Members You will automatically receive the latest hard copy of your standards when they’re revised or replaced To find out more about becoming a BSI Subscribing Member and the benefits of membership, please visit bsigroup.com/shop With a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet Licences can cover as few or as many users as you wish With updates supplied as soon as they’re available, you can be sure your documentation is current For further information, email subscriptions@bsigroup.com Revisions Our British Standards and other publications are updated by amendment or revision We continually improve the quality of our products and services to benefit your business If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please inform the Knowledge Centre Useful Contacts Customer Services Tel: +44 345 086 9001 Email (orders): orders@bsigroup.com Email (enquiries): cservices@bsigroup.com Subscriptions Tel: +44 345 086 9001 Email: subscriptions@bsigroup.com Knowledge Centre Tel: +44 20 8996 7004 Email: knowledgecentre@bsigroup.com Copyright & Licensing Tel: +44 20 8996 7070 Email: copyright@bsigroup.com BSI Group Headquarters 389 Chiswick High Road London W4 4AL UK

Ngày đăng: 14/04/2023, 00:39

Xem thêm:

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN