BS EN 12566-1:2016 BSI Standards Publication Small wastewater treatment systems for up to 50 PT Part 1: Prefabricated septic tanks BS EN 12566-1:2016 BRITISH STANDARD National foreword This British Standard is the UK implementation of EN 12566-1:2016 It supersedes BS EN 12566-1:2000 which is withdrawn The UK participation in its preparation was entrusted to Technical Committee B/505, Wastewater engineering A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © The British Standards Institution 2016 Published by BSI Standards Limited 2016 ISBN 978 580 91476 ICS 13.060.30 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2016 Amendments/corrigenda issued since publication Date Text affected BS EN 12566-1:2016 EN 12566-1 EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM August 2016 ICS 13.060.30 Supersedes EN 12566-1:2000 English Version Small wastewater treatment systems for up to 50 PT - Part 1: Prefabricated septic tanks Petites installations de traitement des eaux usées jusqu'à 50 PTE - Partie 1: Fosses septiques préfabriquées Kleinkläranlagen für bis zu 50 EW - Teil 1: Werkmäßig hergestellte Faulgruben This European Standard was approved by CEN on 25 June 2016 CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels © 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members Ref No EN 12566-1:2016 E BS EN 12566-1:2016 EN 12566-1:2016 (E) Contents Page European foreword Scope Normative references Terms and definitions 4.1 4.1.1 4.1.2 4.1.3 4.2 4.3 4.3.1 4.3.2 4.3.3 4.3.4 4.4 4.5 4.6 4.7 4.8 4.8.1 4.8.2 4.8.3 4.9 Product characteristics Dimensions Inlets, outlets and connections Ventilation Design Basis Load bearing capacity Watertightness 10 General 10 Water test 10 Vacuum test 10 Pneumatic pressure test 10 Hydraulic efficiency 10 Design 10 Access 10 Durability 11 Reaction to fire 11 General 11 Septic tank classified as Class A1 without the need for testing 11 Septic tank classified according to the test results 12 Dangerous substances 12 5.1 5.1.1 5.1.2 5.1.3 5.2 5.3 Testing, assessment and sampling methods 12 Load bearing capacity 12 General 12 Load bearing capacity determined by calculation 13 Load bearing capacity determined by testing 13 Watertightness 15 Hydraulic efficiency 15 6.1 6.2 6.2.1 6.2.2 6.2.3 6.2.4 6.2.5 6.3 6.3.1 6.3.2 6.3.3 6.3.4 6.3.5 Assessment and verification of constancy of performance – AVCP 16 General 16 Type testing 16 General 16 Test samples, testing and compliance criteria 17 Test reports 17 Shared other party results 17 Cascading determination of the product type results 18 Factory production control 19 General 19 Requirements 20 Product specific requirements 23 Initial inspection of factory and of FPC 23 Continuous surveillance of FPC 24 BS EN 12566-1:2016 EN 12566-1:2016 (E) 6.3.6 6.3.7 Procedure for modifications 24 One-off products, pre-production products (e.g prototypes) and products produced in very low quantity 24 7.1 7.2 Classification and designation 25 Classification 25 Nominal capacity 25 8.1 8.2 8.3 Marking, labelling and packaging 25 Marking 25 Installation instructions 26 Operating and maintenance instructions 26 Annex A (normative) Watertightness and nominal capacity tests 27 A.1 General 27 A.2 Capacity test 27 A.2.1 Sample 27 A.2.2 Procedure 27 A.2.3 Expression of results 27 A.3 Watertightness tests 27 A.3.1 Selection of the test 27 A.3.2 Water test 27 A.3.2.1 Sample 27 A.3.2.2 Procedure 28 A.3.2.3 Expression of results 28 A.3.3 Air permeability vacuum test 28 A.3.3.1 Sample 28 A.3.3.2 Procedure 28 A.3.3.3 Expression of results 29 A.3.4 Pneumatic pressure test 29 A.3.4.1 Sample 29 A.3.4.2 Procedure 29 A.3.4.3 Expression of results 30 Annex B (normative) Hydraulic efficiency test 31 B.1 General 31 B.2 Experimental apparatus 31 B.3 Synthetic materials used for testing 32 B.4 Preparation of test 32 B.5 Test parameters 32 B.6 Procedure 33 B.7 Calculation of test results 33 BS EN 12566-1:2016 EN 12566-1:2016 (E) Annex C (informative) Information for execution 34 C.1 Examples for outlet devices 34 C.2 Openings in internal walls 35 Annex D (normative) Test methods for structural behaviour 36 D.1 Selection of test method 36 D.2 Concrete septic tank 36 D.2.1 Crushing test methods 36 D.2.2 Test procedures 37 D.2.2.1 Type A test (vertical load) 37 D.2.2.1.1 Sample 37 D.2.2.1.2 Procedure 37 D.2.2.1.3 Expression of results 37 D.2.2.2 Type B test (horizontal load) 38 D.2.2.2.1 Sample 38 D.2.2.2.2 Procedure 38 D.2.2.2.3 Expression of results 38 D.2.2.3 Type C test (vertical load) 39 D.2.2.3.1 Sample 39 D.2.2.3.2 Procedure 39 D.2.2.3.3 Expression of results 39 D.3 Polyethylene septic tank 39 D.3.1 General 39 D.3.2 Vertical load test 39 D.3.2.1 Sample 39 D.3.2.2 Procedure 40 D.3.2.3 Expression of results 40 D.4 Determination of mechanical characteristics of test samples used for calculation 40 D.4.1 Concrete 40 D.4.2 Glass Reinforced Plastic 41 D.5 Vacuum test for Glass Reinforced Plastic or steel septic tank 41 D.6 Pit test 41 D.6.1 Sample 41 D.6.2 Procedure 41 D.6.3 Expression of results 42 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation 43 ZA.1 Scope and relevant characteristics 43 BS EN 12566-1:2016 EN 12566-1:2016 (E) ZA.2 Procedure of attestation of conformity of prefabricated septic tanks 44 ZA.2.1 System(s) of AVCP 44 ZA.2.2 Declaration of performance (DoP) 47 ZA.2.2.1 General 47 ZA.2.2.2 Content 47 ZA.2.2.3 Example of DoP 48 ZA.3 CE marking and labelling 50 Bibliography 53 BS EN 12566-1:2016 EN 12566-1:2016 (E) European foreword This document (EN 12566-1:2016) has been prepared by Technical Committee CEN/TC 165 “Waste water engineering”, the secretariat of which is held by DIN This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2017, and conflicting national standards shall be withdrawn at the latest by May 2018 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights This document supersedes EN 12566-1:2000 The differences between this version and EN 12566-1:2000 are mainly editorial changes according to the Construction Product Regulation (CPR) This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s) For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document The standard series EN 12566 “Small wastewater treatment systems for up to 50 PT” contains the following parts (see Figure 1): — Part 1: Prefabricated septic tank (this document); — Part 3: Packaged and/or site assembled domestic wastewater treatment plants; — Part 4: Septic tanks assembled in situ from prefabricated kits; — Part 6: Prefabricated treatment unit used for septic tank effluent; — Part 7: Prefabricated tertiary treatment unit For filtration systems, CEN/TC 165 decided to publish the following CEN Technical reports, which are considered as Code of practices and not specify treatment requirements: — Part 2: Soil infiltration systems — Part 5: Pre-treated Effluent Filtration systems BS EN 12566-1:2016 EN 12566-1:2016 (E) Key A domestic wastewater prefabricated septic tank C treated infiltrated effluent packaged and/or site assembled domestic wastewater treatment plant B D E septic tank effluent treated wastewater tertiary wastewater treated soil infiltration system septic tank assembled in situ from prefabricated kit pre-treated effluent filtration system prefabricated treatment unit used for septic tank effluent prefabricated tertiary treatment unit National regulations may specify different arrangements between the products described in the standard series EN 12566 Figure — Scheme related to the arrangement of the parts of EN 12566 According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom BS EN 12566-1:2016 EN 12566-1:2016 (E) Scope This part of this standard specifies the requirements for prefabricated septic tanks and ancillary equipment used for the partial treatment of domestic wastewater for a population ≤ 50 PT Pipes sizes, loads, watertightness, marking and quality control are specified The following cases are excluded: 1) Septic tanks receiving grey water only; 2) In situ constructed septic tanks Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies EN 12566-3:2016, Small wastewater treatment systems up to 50 PT — Part 3: Packaged and/or site assembled domestic wastewater treatment plants EN 16323, Glossary of wastewater engineering terms EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire tests EN 13369, Common rules for precast concrete products EN ISO 14125, Fibre-reinforced plastic composites — Determination of flexural properties (ISO 14125) Terms and definitions For the purposes of this document, the terms and definitions given in EN 16323:2014 and the following apply 3.1 extension shaft component which, placed on the top of the septic tank, allows it to be fitted flush with the ground surface or slightly above ground surface, permits installations to be fitted below the frost line, allows accessibility and enables maintenance work to be carried out Depending on the requirements, it may be vertical extension pieces of the installation housing, or components, which are fitted over maintenance access holes and manholes 3.2 nominal capacity (NC) numerical designation of the volume of a septic tank, expressed as an integer in cubic metres 3.3 prefabricated septic tank single piece factory made unit, including inlet and outlet level openings which leaves the factory completed, controlled and ready for installation BS EN 12566-1:2016 EN 12566-1:2016 (E) Step 4: Step 5: Step 6: Step 7: For tanks made of other materials, discharge the septic tank and measure the volume of water in the septic tank one day later Check the position of the inlet and outlet pipe works Complete the backfill with gravel up to the maximum depth in accordance with the manufacturer’s installation instructions, including the pedestrian load (2,5 kN/m2), converted to a uniform backfill load Seal the inlet and outlet pipe works and, for a wet ground test, add water in the excavation to the level of the top of the septic tank For a septic tank made of concrete or GRP, maintain the test conditions for 24 h For a septic tank made with other materials, maintain the test conditions for weeks In wet condition: examine the inside of the septic tank to show the watertightness is maintained Discharge the water from the excavation If the septic tank is watertight, refill with water, and measure any change in the capacity of the septic tank In dry condition: examine the inside of the septic tank Refill with the volume of water required to fill the septic tank and measure any change in the capacity of the septic tank D.6.3 Expression of results For septic tanks made of concrete or GRP, no failure shall occur during the test In addition, no lack of watertightness shall be recorded For septic tanks made with other materials: — the variation of the volume of the septic tank (expressed in litres) shall be lower than 20 % of the internal volume of the septic tank; — the movement of inlet, outlet and interconnecting pipe works shall not lead to a lack of watertightness Key water table level backfill 42 Figure D.5 — Scheme of the principle for the pit test BS EN 12566-1:2016 EN 12566-1:2016 (E) Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation ZA.1 Scope and relevant characteristics This European Standard has been prepared under Mandate M/118 “Wastewater engineering products” given to CEN by the European Commission and the European Free Trade Association If this European Standard is cited in the Official Journal of the European Union (OJEU), the clauses of this standard, shown in this annex, are considered to meet the provisions of the relevant mandate, under the Regulation (EU) No 305/2011 This annex deals with the CE marking of the prefabricated septic tank intended for the uses indicated in Table ZA.1 and shows the relevant clauses applicable This annex has the same scope as in Clause of this standard related to the aspects covered by the mandate and is defined by Table ZA.1 43 BS EN 12566-1:2016 EN 12566-1:2016 (E) Table ZA.1 — Relevant clauses for product and intended use Product: Prefabricated septic tanks Intended use: To be used outside buildings for faecal water and organic effluent for a population up to 50 PE Clauses in this standard related to essential characteristics Regulatory classes Hydraulic efficiency 4.4 - Tested according to expressed in g of beads Structural behaviour 4.2 - Calculation or test methods in Annex D Essential Characteristics Watertightness 4.3 Durability Reaction to fire Release substance of dangerous 4.7 - - 4.8 A1 to F 4.9 - Notes Annex B and a) Tested according to Annex A; and b) Expressed as “Pass/Fail” together with the test method used a) Tested according to 4.7 (as appropriate) and the material used; and b) Expressed as “Pass/Fail” a) Either classified and declared without need for testing (CWT); or b) Classified and declared, on the basis of the material of the lowest class, in accordance with EN 13501–1 using the relevant test method(s) specified therein As relevant, according to 4.9 The declaration of the product performance related to certain essential characteristics is not required in those Member States (MS) where there are no regulatory requirements on these essential characteristics for the intended use of the product In this case, manufacturers placing their products on the market of these MS are not obliged to determine nor declare the performance of their products with regard to these essential characteristics and the option “No performance determined” (NPD) in the information accompanying the CE marking and in the declaration of performance (see ZA.3) may be used for those essential characteristics ZA.2 Procedure of attestation of conformity of prefabricated septic tanks ZA.2.1 System(s) of AVCP The AVCP system(s) of kits and elements for wastewater treatment plants indicated in Table ZA.1, established by EC Decision(s) 97/464/EC of 27 June 1997 (OJEU L198 of 25.7.1997) as amended by EC decision 2004/663/EC of 20 September 2004 (OJEU L302 of 29.9.2004) is shown in Table ZA.2 for the indicated intended use(s) and relevant level(s) or class(es) of performance 44 BS EN 12566-1:2016 EN 12566-1:2016 (E) Table ZA.2 — System(s) of AVCP Product(s) Kits and elements for wastewater treatment plants* Intended use(s) Level(s) or class(es) of performance AVCP system(s) To be used outside buildings for faecal water and organic effluent - A1**, A2**, B**, C**, D, E For all uses when subject to regulations on reaction to fire A1*, A2*, B*, C* (A1 to E)***, F System 1: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.2 System 3: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.4 System 4: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.5 * Products/ materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g an addition of fire retardants or a limiting of organic material) ** Products/ materials not covered by footnote (*) *** Products/ materials that not require to be tested for reaction to fire (e.g Products/materials of class A1 according to the Decision 96/603/EC, as amended) NOTE Prefabricated septic tanks for a population up to 50 PE are considered kits and elements for wastewater treatment plants The AVCP of the Kits and elements for wastewater treatment plants in Table ZA.1 shall be according to the AVCP procedures indicated in Table(s) ZA.3.1 to ZA.3.3 resulting from application of the clauses of this or other European Standard indicated therein The content of tasks of the notified body shall be limited to those essential characteristics as provided for, if any, in Annex III of the relevant mandate and to those that the manufacturer intends to declare 45 BS EN 12566-1:2016 EN 12566-1:2016 (E) Table ZA.3.1 — Assignment of AVCP tasks for prefabricated septic plants under system Tasks Tasks for the manufacturer Tasks for the notified testing laboratory Factory production control (FPC) Further testing of samples taken at factory according to the prescribed test plan Determination of the producttype on the basis of type testing (based on sampling carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the product Initial inspection of manufacturing plant and of FPC Continuous surveillance, assessment and evaluation of FPC Content of the task AVCP clauses to apply All essential characteristics of Table ZA.1 relevant for the intended use which are declared 6.3.1, 6.3.2, 6.3.3, 6.3.6, 6.3.7 Reaction to fire 6.3 All essential characteristics of Table ZA.1 relevant for the intended use which are declared except reaction to fire 6.2 Reaction to fire 6.3.4 Reaction to fire 6.3.5 Table ZA.3.2 — Assignment of AVCP tasks for prefabricated septic plants under system Tasks Tasks for the manufacturer Tasks for notified testing laboratory 46 a Factory production control (FPC) Determination of the producttype on the basis of type testing (based on sampling carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the product Content of the task AVCP clauses to apply All essential characteristics of Table ZA.1 relevant for the intended use which are declared 6.3.1, 6.3.2, 6.3.3, 6.3.6, 6.3.7 All essential characteristics of Table ZA.1 relevant for the intended use which are declared 6.2 BS EN 12566-1:2016 EN 12566-1:2016 (E) Table ZA.3.3 — Assignment of AVCP tasks for prefabricated septic plants under system Tasks Tasks for the manufacturer Factory production control (FPC) Determination of the producttype on the basis of type testing, type calculation, tabulated values or descriptive documentation of the product Content of the task AVCP clauses to apply All essential characteristics of Table ZA.1 relevant for the intended use which are declared 6.3.1, 6.3.2, 6.3.3, 6.3.6, 6.3.7 All essential characteristics of Table ZA.1 relevant for the intended use which are declared 6.2 ZA.2.2 Declaration of performance (DoP) ZA.2.2.1 General The manufacturer draws up the DoP and affixes the CE marking on the basis of the different AVCP systems set out in Annex V of the Regulation (EU) No 305/2011: In case of products under system — the factory production control and further testing of samples taken at the factory according to the prescribed test plan, carried out by the manufacturer; and — the certificate of constancy of performance issued by the notified product certification body on the basis of determination of the product type on the basis of type testing (including sampling), type calculation, tabulated values or descriptive documentation of the product; initial inspection of the manufacturing plant and of factory production control and continuous surveillance, assessment and evaluation of factory production control In case of products under system — the factory production control carried out by the manufacturer; and — the determination of the product-type on the basis of type testing (based on sampling carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the product, carried out by the notified testing laboratory In case of products under system — the factory production control carried out by the manufacturer; — the determination by the manufacturer of the product-type on the basis of type testing, type calculation, tabulated values or descriptive documentation of the product ZA.2.2.2 Content The model of the DoP is provided in Regulation (EU) No 574/2014 According to this Regulation, the DoP shall contain, in particular, the following information: — the reference of the product-type for which the declaration of performance has been drawn up; — the AVCP system or systems of the construction product, as set out in Annex V of the CPR; 47 BS EN 12566-1:2016 EN 12566-1:2016 (E) — the reference number and date of issue of the harmonized standard which has been used for the assessment of each essential characteristic; — where applicable, the reference number of the Specific Technical Documentation used and the requirements with which the manufacturer claims the product complies The DoP shall in addition contain: a) the intended use or uses for the construction product, in accordance with the applicable harmonized technical specification; b) the list of essential characteristics, as determined in the harmonized technical specification for the declared intended use or uses; c) the performance of at least one of the essential characteristics of the construction product, relevant for the declared intended use or uses; d) where applicable, the performance of the construction product, by levels or classes, or in a description, if necessary based on a calculation in relation to its essential characteristics determined in accordance with the Commission determination regarding those essential characteristics for which the manufacturer shall declare the performance of the product when it is placed on the market or the Commission determination regarding threshold levels for the performance in relation to the essential characteristics to be declared; e) the performance of those essential characteristics of the construction product which are related to the intended use or uses, taking into consideration the provisions in relation to the intended use or uses where the manufacturer intends the product to be made available on the market; f) for the listed essential characteristics for which no performance is declared, the letters “NPD” (No Performance Determined); Regarding the supply of the DoP, article of the Regulation (EU) No 305/2011 applies The information referred to in Article 31 or, as the case may be, in Article 33 of Regulation (EC) No 1907/2006, (REACH) shall be provided together with the DoP ZA.2.2.3 Example of DoP The following gives an example of a filled-in DoP for prefabricated septic tanks DECLARATION OF PERFORMANCE No 0012013-07-14 Unique identification code of the product-type: Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11: Prefabricated septic tank BWV 714 (concrete) BWV 714 from to 50 PT 48 BS EN 12566-1:2016 EN 12566-1:2016 (E) Intended use or uses of the construction product, in accordance with the applicable harmonized technical specification, as foreseen by the manufacturer: To be used outside buildings for faecal water and organic effluent for a population up to 50 PE Name, registered trade name or registered trade mark and contact address of the manufacturer as required under Article 11: AnyCo SA, PO Box 21 B-1050 Brussels, Belgium Tel +32987654321 Email: anyco.sa@provider.be Where applicable, name and contact address of the authorized representative whose mandate covers the tasks specified in Article 12: Anyone Ltd Flower Str 24 West Hamfordshire UK-589645 United Kingdom Tel +44987654321 e-mail: anyone.ltd@provider.uk System or systems of assessment and verification of constancy of performance of the construction product as set out in CPR, Annex V: System for all essential characteristics except reaction to fire System for reaction to fire In case of the declaration of performance concerning a construction product covered by a harmonized standard: Notified body number 0001 performed product type testing under system and issued test report 12345/2013 No European Technical Assessment has been issued for this product 49 BS EN 12566-1:2016 EN 12566-1:2016 (E) Declared performance Essential characteristics Reaction to fire Hydraulic efficiency Nominal capacity Watertightness Crushing resistance Durability Release of dangerous substance Performance Class A1 XXX g of beads Harmonized technical specification EN 12566–1:2016 m3 Pass xxx kN Pass NPD 10 The performance of the product identified in points and is in conformity with the declared performance in point This declaration of performance is issued under the sole responsibility of the manufacturer identified in point Signed for and on behalf of the manufacturer by: (name and function) (place and date of issue) ZA.3 CE marking and labelling (signature) The CE marking symbol shall be in accordance with the general principles set out in Article 30 of Regulation (EC) No 765/2008 and shall be affixed visibly, legibly and indelibly: — to the prefabricated septic tank; — to a label attached to it Where this is not possible or not warranted on account of the nature of the product, it shall be affixed: — to the packaging; or — to the accompanying documents The CE marking shall be followed by: — the last two digits of the year in which it was first affixed; — the name and the registered address of the manufacturer, or the identifying mark allowing identification of the name and address of the manufacturer easily and without any ambiguity; — the unique identification code of the product-type; 50 BS EN 12566-1:2016 EN 12566-1:2016 (E) — the reference number of the declaration of performance; — the level or class of the performance declared; — the dated reference to the harmonized technical specification applied as it appears in OJEU; — the identification number of the notified body; — the intended use as laid down in the harmonized technical specification applied The CE marking shall be affixed before the construction product is placed on the market It may be followed by a pictogram or any other mark notably indicating a special risk or use Figure ZA.1 gives an example of the information related to products subject to AVCP under system (all characteristics except reaction to fire) and (for reaction to fire) 51 BS EN 12566-1:2016 EN 12566-1:2016 (E) “CE marking, consisting of the “CE”-symbol Identification number of the notified test laboratory 9876 Any Co Ltd, P.O Box 21, B–1050 Name and the registered address of the manufacturer, or identifying mark 16 Last two digits of the year in which the marking was first affixed 0012013–07–14 Reference number of the DoP EN 12566–1:2016 No of European Standard applied, as referenced in OJEU Prefabricated septic tank — Product’s reference code: — Material: “BWV 714” CONCRETE Hydraulic efficiency XXX g of beads Nominal capacity m3 Watertightness: test) Crushing resistance Durability Reaction to fire Release of substances Unique identification code of the product-type Intended use of the product as laid down in the European Standard applied Level or class of the performance declared (water Pass xxx kN Pass A1 dangerous NPD Figure ZA.1 — Example CE marking information of products under AVCP system (all characteristics except reaction to fire) and (reaction to fire) 52 BS EN 12566-1:2016 EN 12566-1:2016 (E) Bibliography [1] [2] EN ISO 9001, Quality management systems — Requirements (ISO 9001) EN 476, General requirements for components used in drains and sewers 53 This page deliberately left blank This page deliberately left blank NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW British Standards Institution (BSI) BSI is the national body responsible for preparing British Standards and other standards-related publications, information and services BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited About us Reproducing extracts We bring together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions For permission to reproduce content from BSI publications contact the BSI Copyright & Licensing team The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process Organizations of all sizes and across all sectors choose standards to help them achieve their goals Information on standards We can provide you with the knowledge that your organization needs to succeed Find out more about British Standards by visiting our website at bsigroup.com/standards or contacting our Customer Services team or Knowledge Centre Buying standards You can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at bsigroup.com/shop, where hard copies can also be purchased If you need international and foreign standards from other Standards Development Organizations, hard copies can be ordered from our Customer Services team Copyright in BSI publications All the content in BSI publications, including British Standards, is the property of and copyrighted by BSI or some person or entity that owns copyright in the information used (such as the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use Save for the provisions below, you may not transfer, share or disseminate any portion of the standard to any other person You may not adapt, distribute, commercially exploit, or publicly display the standard or any portion thereof in any manner whatsoever without BSI’s prior written consent Storing and using standards Standards purchased in soft copy format: • A British Standard purchased in soft copy format is licensed to a sole named user for personal or internal company use only • The standard may be stored on more than device provided that it is accessible by the sole named user only and that only copy is accessed at any one time • A single paper copy may be printed for personal or internal company use only Standards purchased in hard copy format: • A British Standard purchased in hard copy format is for personal or internal company use only • It may not be further reproduced – in any format – to create an additional copy This includes scanning of the document If you need more than copy of the document, or if you wish to share the document on an internal network, you can save money by choosing a subscription product (see ‘Subscriptions’) Subscriptions Our range of subscription services are designed to make using standards easier for you For further information on our subscription products go to bsigroup.com/subscriptions With British Standards Online (BSOL) you’ll have instant access to over 55,000 British and adopted European and international standards from your desktop It’s available 24/7 and is refreshed daily so you’ll always be up to date You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single copy and subscription format, by becoming a BSI Subscribing Member PLUS is an updating service exclusive to BSI Subscribing Members You will automatically receive the latest hard copy of your standards when they’re revised or replaced To find out more about becoming a BSI Subscribing Member and the benefits of membership, please visit bsigroup.com/shop With a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet Licences can cover as few or as many users as you wish With updates supplied as soon as they’re available, you can be sure your documentation is current For further information, email subscriptions@bsigroup.com Revisions Our British Standards and other publications are updated by amendment or revision We continually improve the quality of our products and services to benefit your business If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please inform the Knowledge Centre Useful Contacts Customer Services Tel: +44 345 086 9001 Email (orders): orders@bsigroup.com Email (enquiries): cservices@bsigroup.com Subscriptions Tel: +44 345 086 9001 Email: subscriptions@bsigroup.com Knowledge Centre Tel: +44 20 8996 7004 Email: knowledgecentre@bsigroup.com Copyright & Licensing Tel: +44 20 8996 7070 Email: copyright@bsigroup.com BSI Group Headquarters 389 Chiswick High Road London W4 4AL UK

Ngày đăng: 14/04/2023, 00:40

Xem thêm:

TỪ KHÓA LIÊN QUAN

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN