1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 00490 2011 + a1 2017

36 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

BS EN 490:201 +A1 :201 BSI Standards Publication Concrete roofing tiles and fittings for roof covering and wall cladding — Product specifications BS EN 490:201 +A1 :201 BRITISH STANDARD National foreword This British Standard is the UK implementation of EN 490:201 +A1 :201 It supersedes BS EN 490:201 which is withdrawn The start and finish of text introduced or altered by amendment is indicated in the text by tags Tags indicating changes to CEN text carry the number of the CEN amendment For example, text altered by CEN amendment A1 is indicated by !" The UK participation in its preparation was entrusted by Technical Committee B/542, Roofing and cladding products for discontinuous laying, to Subcommittee B/542/2, Concrete roofing tiles and fittings A list of organizations represented on this su b committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © The British Standards Institution 201 Published by BSI Standards Limited 201 ISBN 978 580 90294 ICS 91 00.30 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 201 Amendments/corrigenda issued since publication Date Text affected 31 January 201 Implementation of CEN amendment A1 :201 EUROPEAN STANDARD EN 490:2011+A1 NORME EUROPÉENNE EUROPÄISCHE NORM January 2017 ICS 91.100.30 Supersedes EN 490:2011 English Version Concrete roofing tiles and fittings for roof covering and wall cladding - Product specifications Tuiles et accessoires en béton pour couverture et bardage - Spécifications des produits Dach- und Formsteine aus Beton für Dächer und Wandbekleidungen - Produktanforderungen This European Standard was approved by CEN on 18 September 2011 and includes Amendment approved by CEN on 10 November 2015 CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom EUROPEAN COMMITTEE FOR STANDARDIZATION C O M I TÉ E URO PÉ E N D E N O RM ALI S ATI O N E URO PÄI S C H E S KO M I T E E FÜR N O RM UN G CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels © 2017 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members Ref No EN 490:2011+A1:2017 E BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) Contents Page European foreword Scope Normative references Terms and definitions 4 Symbols and abbreviations 5 Requirements 6 ! Assessment and verification of constancy of performance (AVCP)" 10 Sampling 11 Designation system 13 Marking and labelling 14 10 Documents 14 Annex A (informative) Surface characteristics 15 Annex B (informative) Performance of assemblies of roofing tiles and fittings 16 Annex C (normative) Fasteners and fixings 17 Annex D (normative) Sampling procedure 18 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation 19 Bibliography 31 BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) European foreword This document (EN 490:2011+A1:2017) has been prepared by Technical Committee CEN/TC 128 “Roof covering products for discontinuous laying and products for wall cladding”, the secretariat of which is held by NBN This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2017, and conflicting national standards shall be withdrawn at the latest by October 2018 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights This document includes Amendment approved by CEN on 2015-11-10 This document supersedes ! EN 490:2011" The start and finish of text introduced or altered by amendment is indicated in the text by tags ! " This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s) For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document ! This amendment to Annex ZA of EN 490:2011 implements EU Regulation no 305/2011." According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) Scope This European Standard specifies requirements for concrete roofing tiles and fittings for pitched roof coverings and wall cladding and lining Concrete roofing tiles and fittings may incorporate surface coatings and glued concrete components NOTE Information on surface characteristics is given in Annex A NOTE Information on the performance of roof and wall assemblies is given in Annex B Normative references The following referenced documents are indispensable for the application of this document For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies EN 491:2011, Concrete roofing tiles and fittings for roof covering and wall cladding — Test methods ENV 1187, Test methods for external fire exposure to roofs Reaction to fire tests for building products — Conditioning procedures and general rules for selection of substrates EN 13238, EN 13823, Reaction to fire tests for building products — Building products excluding floorings exposed to the thermal attack by a single burning item Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire tests EN 13501-1, EN 13501-5, Fire classification of construction products and building elements — Part 5: Classification using data from external fire exposure to roof tests Reaction to fire tests for products — Determination of the gross heat of combustion (calorific value) (ISO 716:2010) EN ISO 1716, Terms and definitions For the purposes of this document, the following terms and definitions apply 3.1 aggregate concrete component consisting of uncrushed and/or crushed natural and/or artificial mineral substances with particle sizes and shapes suitable for the production of concrete 3.2 additive finely divided material that may be added to concrete in order to improve certain properties or to achieve special properties 3.3 pigment additive intended to add colour to the concrete BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) 3.4 admixture material which is added in small quantities relative to the mass of the cement before or during mixing or during an additional mixing operation, causing required modifications to the properties 3.5 cement hydraulic binder, i.e finely ground inorganic material, which, when mixed with water, forms a paste which sets by means of hydration reactions and processes and which, after hardening, retains its strength and stability 3.6 fitting component, of concrete, that is complementary to the tiles and has a special function NOTE Fittings may contain inserts of other materials 3.6.1 coordinated fitting fitting that is intended to align or interlock with the tiles with which it is to be laid (e.g interlocking verge tile, interlocking ventilation tile, tile-and-a-half, aligning valley tile, interlocking or aligning angle tiles) 3.7 valley tile fitting for use at a meeting of two roof pitches forming a re-entrant angle 3.8 interlocking tile profiled or flat tile which has a side lock, with or without a head lock feature 3.9 non-interlocking tile profiled or flat tile without interlocks 3.10 tile with a regular front edge tile (interlocking or non-interlocking) which, by design, has a constant or regularly varying hanging length across the width 3.11 tile with an irregular front edge tile (interlocking or non-interlocking), which, by design, has an irregular varying hanging length across the width ! 3.12 product type set of representative performance levels or classes of a construction product, in relation to its essential characteristics, produced using a given combination of raw materials or other elements in a specific production process " BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) Symbols and abbreviations For the purposes of this document, the following symbols and abbreviations apply l1 hanging length of a tile l2 , l3 hanging edge length of a tile, as defined in EN 491:2011 , Clause cw cover width of one tile cwc cover width closed up value of 10 tiles cwd cover width drawn out value of 10 tiles d profile depth of a tile Fmin minimum transverse strength of all tiles Fi transverse strength of an individual tile IL interlocking NL non-interlocking RF regular front edge IF irregular front edge / not applicable or not declared characteristic for designation system Requirements 5.1 Materials The concrete used in the manufacture of tiles and fittings shall be formed by mixing cement, aggregate and water and produced by the hardening of the cement paste (cement and water) NOTE In addition to the basic components, the concrete may also contain pigments, admixtures and/or additives 5.2 Dimensions 5.2.1 Hanging length and squareness The tile hanging length shall be declared in the manufacturer’s technical specification For tiles with a regular front edge, the values of l1 shall be ± mm of the manufacturer’s declared value when tested in accordance with EN 491:2011, 5.2 The squareness for tiles with nominally constant hanging length, when tested in accordance with EN 491:2011, 5.2.2.1, shall be calculated as the difference between values l2 and l3 and shall be not greater than mm This sub-clause does not apply for tiles that are designed, for example for aesthetic reasons, with an irregular front edge 5.2.2 Cover width 5.2.2.1 General The tile cover width cw shall be declared in the manufacturer’s technical specification NOTE The cover width shunts may also be declared in the manufacturer’s technical specification This sub-clause does not apply for tiles that are designed, for example for aesthetic reasons, with a randomly varying cover width BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) 5.2.2.2 Interlocking tiles When tiles with cover width shunts declared by the manufacturer are tested in accordance with EN 491:2011, 5.3.3.1, the cover width shall conform to the following: — cwd/10 ≥ cw + declared “plus cover width shunt”; — cwc/ 10 ≤ cw - declared “minus cover width shunt” When tiles without cover width shunts, and tiles with cover width shunt but not declared by the manufacturer, are tested in accordance with EN 491:2011, 5.3.3.1, the mean cover width shall be ± mm of the manufacturer’s declared cover width 5.2.2.3 Non-interlocking tiles When non-interlocking tiles are tested in accordance with EN 491:2011, 5.3.3.2, the mean cover width shall be ± mm of the manufacturer’s declared value 5.2.3 Flatness When tiles are tested in accordance with EN 491:2011, 5.4, the gap between any designed contact point and the flat surface shall not exceed mm or cw/100 mm to the nearest millimetre, whichever is the greater This sub-clause does not apply where the manufacturer declares that: — tiles are designed to have less than four contact points to a flat surface, and/or — tiles are designed to be irregular in flatness 5.2.4 Fittings The manufacturer shall identify and declare the dimensions and tolerances and method of measurement of the fitting relevant to its use Where relevant, the tile element of a coordinated fitting shall conform to 5.2.1, 5.2.2 and 5.2.3 5.3 Mass The mass of tiles and fittings shall be declared in the manufacturer’s technical specification When tiles are tested in accordance with EN 491:2011, 5.5, the mean mass shall be: a) manufacturer’s declared mass ± 0,2 kg for tiles with a declared mass not greater than kg; b) manufacturer’s declared mass ± 10 % for tiles with a declared mass greater than kg 5.4 Fixing holes (where provided) Fixing holes, where provided, shall be arranged so that an intended connection between the tiles and/or fittings and the batten can be achieved NOTE Information on fasteners and fixings is given in Annex C Details of the size and position of the fixing holes may be given in the manufacturer’s technical and/or commercial literature 5.5 Mechanical resistance (transverse strength) When tiles are tested in accordance with EN 491:2011, 5.6: a) value of Fmin shall be not less than the appropriate value given in Table 1, or BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) b) number of individual tiles with transverse strength values (Fi) less than the appropriate value in Table 1, shall be not more than the appropriate acceptance value in 7.3 Tiles tested prior to 28 days after manufacture shall be deemed to conform if they reach at least 80 % of the values specified in Table and the manufacturer can demonstrate statistically that the values given in Table are achieved at 28 days Fittings shall conform to 5.2.4 and 5.7.2 (and 5.7.3 in the case of valley tiles) Table — Minimum transverse strength Fmin of tiles Non-interlocking tiles Interlocking tiles Property Profiled Profile depth d > 20mm Flat 20 mm ≥ d ≥ mm d < 5mm cw (mm) ≥ 300 ≤ 200 ≥ 300 ≤ 200 ≥ 300 ≤ 200 Fmin (N) 000 400 400 000 200 800 550 The profile depth (d) shall be declared by the manufacturer and, if d < 20 mm, shall be measured in accordance with EN 491:2011, 5.6.4.1 For interlocking tiles between 200 mm and 300 mm cover width, the minimum transverse strength shall be determined by linear interpolation between the values given in Table 5.6 Water impermeability When tested in accordance with EN 491:2011, 5.7 the underside of the tiles and/or valley tiles may show drops of water but no drops shall fall before the completion of the test (20 h) Fittings, other than valley tiles, are not required to be tested for water impermeability, provided they conform to 5.2.4 and 5.7.2 5.7 Durability (freeze-thaw resistance) 5.7.1 Tiles When tested in accordance with EN 491:2011, 5.8, the tiles shall conform to the requirements for impermeability (see 5.6) and transverse strength (see 5.5) 5.7.2 Fittings Fittings, other than valley tiles, when tested in accordance with EN 491:2011, 5.8, shall not be broken, separated into parts or cracked 5.7.3 Valley tiles When tested in accordance with EN 491:2011, 5.8, valley tiles shall conform to the requirements for impermeability (see 5.6) 5.8 Nib support Tiles with nib(s) shall be tested in accordance with EN 491:2011, 5.9 The tile nib(s) shall support the tile in the test position so that the tile does not fall BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) Table ZA.1.1 — Relevant clauses for roof coverings Product: Concrete roofing tiles and fittings Intended use: for pitched roof coverings Essential Characteristics Clauses in this and other European Standard(s) related to essential characteristics Regulatory classes Mechanical resistance 5.5 - Declared compliance External fire resistance 5.9.1 - Declared class Reaction to fire 5.9.2 Classes A1 to F Notes Declared class Water impermeability 5.6 - Declared compliance Dimensional variation 5.2 - Declared compliance Durability 5.7 - Declared compliance Release of dangerous substances 5.10 - - Table ZA.1.2 — Relevant clauses for external wall cladding and internal wall lining Product: Concrete roofing tiles and fittings Intended use: for external wall cladding and internal wall lining Essential Characteristics Clauses in this and other European Standard(s) related to essential characteristics Mechanical resistance Reaction to fire 5.5 5.9.2 Regulatory classes Notes - Declared compliance Declared class Classes A1 to F Water impermeability 5.6 - Declared compliance Dimensional variation 5.2 - Declared compliance Durability 5.7 - Declared compliance Release of dangerous substances 5.10 - - The declaration of the product performance related to certain essential characteristics is not required in those Member States (MS) where there are no regulatory requirements on these essential characteristics for the intended use of the product In this case, manufacturers placing their products on the market of these MS are not obliged to determine nor declare the performance of their products with regard to these essential characteristics and the option “No performance determined” (NPD) in the information accompanying the CE marking and in the declaration of performance (see ZA.3) may be used for those essential characteristics 20 BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) ZA.2 Procedure for AVCP ZA.2.1 System(s) of AVCP The AVCP system(s) of concrete roofing tiles and fittings indicated in: — Table ZA.1.1 in accordance with the Decision of the Commission 98/436/EC of 1998-06-22 (see OJEU L1 94 of 998-07-1 0), as corrected (see OJEU L278 of 998-1 0-1 5) and amended by 2001/596/EC of 2001-01-08 (see OJEU L209 of 2001 -08-02 ), and — Table ZA.1.2, in accordance with the Decision of the Commission 98/437/EC of 1998-06-30 (see OJEU L1 94 of 998-07-1 0), as corrected (see OJEU L278 of 998-1 0-1 5) and amended by 2001/596/EC of 2001-01-08 (see OJEU L209 of 2001 -08-02 ), are shown in Table ZA.2 for the indicated intended uses and relevant levels or classes Table ZA.2 — Systems of AVCP Product(s) Intended use(s) Roofing tiles, slates, stones For uses subject to reaction and shingles to fire regulations Level(s) or class(es) of performance AVCP systems A1*, A2*, B* and C* A1**, A2**, B**, C**, D and E (A1 to E)***, F For uses subject to external fire performance regulations For uses subject to regulations on dangerous substances For uses other than specified above Tiles, sidings, panels As internal or external finishes in wall or ceilings subject to reaction to fire regulations See EN 13501-5 F ROOF 4 – – A1*, A2*, B* and C* A1**, A2**, B**, C**, D and E (A1 to E)***, F As internal or external finishes in walls or ceilings, as relevant, subject to regulations on dangerous substances – As internal or external finishes in walls or ceilings for other uses mentioned in the mandate – 21 BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) Product(s) * Intended use(s) Level(s) or class(es) of performance AVCP systems Products/materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g an addition of fire retardants or a limiting of organic material) ** Products/materials not covered by footnote (*) *** Products/materials that not require to be tested for reaction to fire (e.g products/materials of Class A1 according to Commission Decision 96/603/EC) System 1: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.2 System 3: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.4 System 4: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.5 NOTE The products which are listed in Table ZA.2 are cited as they are in the relevant Commission Decisions Concrete roofing tiles and fittings belong to those families of products – Most of the products are subject to a reaction to fire class under system The AVCP of the concrete roofing tiles and fittings in Tables ZA.1.1 to ZA.1.2 shall be according to the AVCP procedures indicated in Tables ZA.3.1 to ZA.3.3 resulting from application of the clauses of this or other European Standard indicated therein The content of tasks of the notified body shall be limited to those essential characteristics as provided for, if any, in Annex III of the relevant mandate and to those that the manufacturer intends to declare 22 BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) Table ZA.3.1 — Assignment of AVCP tasks under system (for reaction to fire classes A1*, A2*, B* and C*), system (for external fire performance) and system (for other uses) Tasks Factory production control (FPC) Tasks for the manufacturer Content of the task Parameters related to essential characteristics of Table ZA.1.1 and/or Table ZA.1.2 relevant for the intended use which are declared Determination of the product- Essential characteristics of Table type on the basis of ZA.1.1 and/or Table ZA.1.2 relevant for the intended use which are type testing, type calculation, declared, except reaction to fire, tabulated values or external fire performance and release descriptive documentation of of dangerous substances the product Further testing of samples taken at factory according to the prescribed test plan Essential characteristics of Table ZA.1.1 and/or Table ZA.1.2 relevant for the intended use which are declared Determination of the producttype on the basis of type testing (based on sampling Tasks for a carried out by the Release of dangerous substance and notified testing manufacturer), type external fire performance laboratory calculation, tabulated values AVCP clauses to apply 6.3 6.2 6.3 6.2 or descriptive documentation of the product Determination of the product type on the basis of type testing (including sampling), Reaction to fire type calculation, tabulated values or descriptive documentation of the product Tasks for the Initial inspection of notified product manufacturing plant and of certification body FPC Continuous surveillance, assessment and evaluation of FPC Parameters related to essential characteristics of Table ZA.1.1 and/or Table ZA.1.2, relevant for the intended use which are declared, namely reaction to fire 6.2 6.3 Documentation of the FPC Parameters related to essential characteristics of Table ZA.1.1 and/or Table ZA.1.2, relevant for the intended use which are declared, namely reaction to fire 6.3 Documentation of FPC 23 BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) Table ZA.3.2 — Assignment of AVCP tasks under system (for reaction to fire classes A1**, A2**, B**, C**, D and E), system (for external fire performance) and system (for other uses) Tasks Tasks for the manufacturer Tasks for a notified testing laboratory Content of the task AVCP clauses to apply Factory production control (FPC) Parameters related to essential characteristics of Table ZA.1.1 and/or Table ZA.1.2 relevant for the intended use which are declared 6.3 Determination of the product-type on the basis of type testing, type calculation, tabulated values or descriptive documentation of the product Essential characteristics of Table ZA.1.1 and/or Table ZA.1.2 relevant for the intended use which are declared, except reaction to fire ,external fire performance and release of dangerous substances 6.2 Determination of the product-type on the basis of type testing (based on sampling carried out by the Reaction to fire, Release of dangerous manufacturer), type substance and external fire performance calculation, tabulated values or descriptive documentation of the product 6.2 Table ZA.3.3 — Assignment of AVCP tasks under system (for reaction to fire classes (A1 to E)***, F), system (for external fire performance) and system (for other uses) Tasks Factory production control (FPC) Tasks for the manufacturer Tasks for a notified testing laboratory 24 Determination of the product-type on the basis of type testing, type calculation, tabulated values or descriptive documentation of the product Determination of the product-type on the basis of type testing (based on sampling carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the product Content of the task AVCP clauses to apply Parameters related to essential characteristics of Table ZA.1.1 and/or Table ZA.1.2 relevant for the intended use which are declared 6.3 Essential characteristics of Table ZA.1.1 and/or Table ZA.1.2 relevant for the intended use which are declared, except, external fire performance and release of dangerous substances 6.2 External fire performance and release of dangerous substances 6.2 BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) ZA.2.2 Declaration of performance (DoP) ZA.2.2.1 General The manufacturer draws up the DoP and affixes the CE marking on the basis of the different AVCP systems set out in Annex V of the Regulation (EU) No 305/2011: a) In case of products under system — the factory production control and further testing of samples taken at the factory according to the prescribed test plan, carried out by the manufacturer; and — the certificate of constancy of performance issued by the notified product certification body on the basis of determination of the product type on the basis of type testing (including sampling), type calculation, tabulated values or descriptive documentation of the product; initial inspection of the manufacturing plant and of factory production control, assessment and evaluation of factory production control b) In case of products under system — the factory production control carried out by the manufacturer; and — the determination of the product-type on the basis of type testing (based on sampling carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the product, carried out by the notified testing laboratory c) In case of products under system — the factory production control carried out by the manufacturer; — the determination by the manufacturer of the product-type on the basis of type testing, type calculation, tabulated values or descriptive documentation of the product ZA.2.2.2 Content The model of the DoP is provided in Annex III of the Regulation (EU) No 305/2011 According to this Regulation, the DoP shall contain, in particular, the following information: — the reference of the product-type for which the declaration of performance has been drawn up; — the AVCP system or systems of the construction product, as set out in Annex V of the CPR; — the reference number and date of issue of the harmonised standard which has been used for the assessment of each essential characteristic; — where applicable, the reference number of the Specific Technical Documentation used and the requirements with which the manufacturer claims the product complies The DoP shall in addition contain: a) the intended use or uses for the construction product, in accordance with the applicable harmonised technical specification; b) the list of essential characteristics, as determined in the harmonised technical specification for the declared intended use or uses; 25 BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) c) the performance of at least one of the essential characteristics of the construction product, relevant for the declared intended use or uses; d) where applicable, the performance of the construction product, by levels or classes, or in a description, if necessary based on a calculation in relation to its essential characteristics determined in accordance with the Commission determination regarding those essential characteristics for which the manufacturer shall declare the performance of the product when it is placed on the market or the Commission determination regarding threshold levels for the performance in relation to the essential characteristics to be declared; e) the performance of those essential characteristics of the construction product which are related to the intended use or uses, taking into consideration the provisions in relation to the intended use or uses where the manufacturer intends the product to be made available on the market; f) for the listed essential characteristics for which no performance is declared, the letters "NPD" (No Performance Determined) Regarding the supply of the DoP, Article of the Regulation (EU) No 305/2011 applies The information referred to in Article 31 or, as the case may be, in Article 33 of Regulation (EC) No 1907/2006, (REACH) shall be provided together with the DoP ZA.2.2.3 Example of DoP The following gives an example of a filled-in DoP for concrete roofing tiles and fittings: DECLARATION OF PERFORMANCE No 001DoP2014-07-14 Unique identification code of the product-type: Concrete roofing tiles and fittings NT_AB300 Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11(4): Concrete roofing tiles and fittings NT_AB300 Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer: For pitched roof coverings and wall cladding and lining Name, registered trade name or registered trade mark and contact address of the manufacturer as required under Article 11(5): AnyCo SA, PO Box 21 B-1050 Brussels, Belgium Tel +32987654321 Fax: +32123456789 Email: anyco.sa@provider.be 26 BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) Where applicable, name and contact address of the authorised representative whose mandate covers the tasks specified in Article 12(2): Anyone Ltd Flower Str 24 West Hamfordshire UK-589645 United Kingdom Tel +44987654321 Fax: +44123456789 e-mail: anyone.ltd@provider.uk System or systems of assessment and verification of constancy of performance of the construction product as set out in CPR, Annex V: System In case of the declaration of performance concerning a construction product covered by a harmonised standard: Notified testing laboratory No 5678 performed the determination of the product-type on the basis of type testing (based on sampling carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the product Declared performance Essential characteristics Performance Mechanical resistance Complies External fire performance B roof (deemed to satisfy) Reaction to fire Harmonized technical specification Class A1 Water impermeability Complies Dimensional variation Complies Durability Complies EN 490:2011+A1:2017 The performance of the product identified in points and is in conformity with the declared performance in point This declaration of performance is issued under the sole responsibility of the manufacturer identified in point Signed for and on behalf of the manufacturer by: ……………………………………………………………………………………………………………………………… (name and function) ………………………………… …………… ………………………………… …………… (place and date of issue) (signature) ZA.3 CE marking and labelling The CE marking symbol shall be in accordance with the general principles set out in Article 30 of Regulation (EC) No 765/2008 and shall be affixed visibly, legibly and indelibly: — to the concrete roofing tiles or 27 BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) — to a label attached to it Where this is not possible or not warranted on account of the nature of the product, it shall be affixed: — to the packaging or — to the accompanying documents The CE marking shall be followed by: — the last two digits of the year in which it was first affixed; — the name and the registered address of the manufacturer, or the identifying mark allowing identification of the name and address of the manufacturer easily and without any ambiguity; — the unique identification code of the product-type; — the reference number of the declaration of performance; — the level or class of the performance declared; — the dated reference to the harmonised technical specification applied; — the identification number of the notified body, (only for products under systems , and 3]; — the intended use as laid down in the harmonised technical specification applied The CE marking shall be affixed before the construction product is placed on the market It may be followed by a pictogram or any other mark notably indicating a special risk or use Figures ZA.1 and ZA.2 give examples of the information related to products subject to AVCP system and 28 BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) CE marking, consisting of the “CE”-symbol 5678 Identification number of the notified test laboratory AnyCo Ltd, PO Box 21, B-1050, Brussels, Belgium Name and the registered address of the manufacturer, or identifying mark 17 Last two digits of the year in which the marking was first affixed 001-DoP-2014-07-14 EN 490:2011+A1:2017 NT_AB300 For pitched roof coverings and wall cladding and lining Mechanical resistance: Complies External fire performance: B roof (deemed to satisfy) Reference number of the DoP No of European Standard applied, as referenced in OJEU Unique identification code of the producttype Intended use of the product as laid down in the European Standard applied Level or class of the performance declared Reaction to fire: Class A Water impermeability: Complies Dimensional variation: Complies Durability: Complies Figure ZA.1 — Example CE marking information of products under AVCP system 29 BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) CE marking, consisting of the “CE”-symbol AnyCo Ltd, PO Box 21, B-1050, Brussels, Belgium Name and the registered address of the manufacturer, or identifying mark 17 Last two digits of the year in which the marking was first affixed 001-DoP-2014-07-14 EN 490:2011+A1:2017 NT_AB300 For pitched roof coverings and wall cladding and lining Mechanical resistance: Complies External fire performance: B roof (deemed to satisfy) Reference number of the DoP No of European Standard applied, as referenced in OJEU Unique identification code of the product-type Intended use of the product as laid down in the European Standard applied Level or class of the performance declared Reaction to fire: Class A Water impermeability: Complies Dimensional variation: Complies Durability: Complies Figure ZA.2 — Example CE marking information of products under AVCP system 30 " BS EN 490:2011+A1:2017 EN 490:2011+A1:2017 (E) Bibliography [1] 2000/553/EC Commission Decision of September 2000 implementing Council Directive 89/106/EEC as regards the external fire performance of roof coverings, O.J L 235/19 of 19.9.2000 [2] 96/603/EC Commission Decision of October 1996 establishing the list of products belonging to Classes A ‘No contribution to fire’ provided for in Decision 94/611/EC implementing Article 20 of Council Directive 89/106/EEC on construction products, O.J L 267/23 of 19.10.1996, as amended by 2000/605/EC, O.J L 258/36 of 12.10.2000 [3] EN 14437, Determination of the uplift resistance of installed clay or concrete tiles for roofing — Roof system test method [4] CEN/TS 15087, Determination of the uplift resistance of installed clay and concrete interlocking tiles for roofing — Test method for mechanical fasteners [5] EN ISO 9001, Quality management systems — Requirements (ISO 9001 :2008) 31 This page deliberately left blank This page deliberately left blank NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW British Standards Institution (BSI) BSI is the national body responsible for preparing British Standards and other standards-related publications, information and services BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited About us Reproducing extracts We bring together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions For permission to reproduce content from BSI publications contact the BSI Copyright & Licensing team The knowledge embodied in our standards has been carefully assembled in a dependable format and re f ned through our open consultation process Organizations of all sizes and across all sectors choose standards to help them achieve their goals Information on standards We can provide you with the knowledge that your organization needs to succeed Find out more about British Standards by visiting our website at bsigroup.com/standards or contacting our Customer Services team or Knowledge Centre Buying standards You can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at bsigroup.com/shop, where hard copies can also be purchased If you need international and foreign standards from other Standards Development Organizations, hard copies can be ordered from our Customer Services team Copyright in BSI publications All the content in BSI publications, including British Standards, is the property of and copyrighted by BSI or some person or entity that owns copyright in the information used (such as the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use Save for the provisions below, you may not transfer, share or disseminate any portion of the standard to any other person You may not adapt, distribute, commercially exploit, or publicly display the standard or any portion thereof in any manner whatsoever without BSI’s prior written consent Storing and using standards Standards purchased in soft copy format: • A British Standard purchased in soft copy format is licensed to a sole named user for personal or internal company use only • The standard may be stored on more than device provided that it is accessible by the sole named user only and that only copy is accessed at any one time • A single paper copy may be printed for personal or internal company use only Standards purchased in hard copy format: • A British Standard purchased in hard copy format is for personal or internal company use only • It may not be further reproduced – in any format – to create an additional copy This includes scanning of the document If you need more than copy of the document, or if you wish to share the document on an internal network, you can save money by choosing a subscription product (see ‘Subscriptions’) Subscriptions Our range of subscription services are designed to make using standards easier for you For further information on our subscription products go to bsigroup.com/subscriptions With British Standards Online (BSOL) you’ll have instant access to over 55,000 British and adopted European and international standards from your desktop It’s available 24/7 and is refreshed daily so you’ll always be up to date You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single copy and subscription format, by becoming a BSI Subscribing Member PLUS is an updating service exclusive to BSI Subscribing Members You will automatically receive the latest hard copy of your standards when they’re revised or replaced To f nd out more about becoming a BSI Subscribing Member and the bene f ts of membership, please visit bsigroup.com/shop With a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet Licences can cover as few or as many users as you wish With updates supplied as soon as they’re available, you can be sure your documentation is current For further information, email subscriptions@bsigroup.com Revisions Our British Standards and other publications are updated by amendment or revision We continually improve the quality of our products and services to bene f t your business If you f nd an inaccuracy or ambiguity within a British Standard or other BSI publication please inform the Knowledge Centre Useful Contacts Customer Services Tel: +44 345 086 9001 Email (orders): orders@bsigroup com Email (enquiries): cservices@bsigroup com Subscriptions Tel: +44 345 086 9001 Email: subscriptions@bsigroup com Knowledge Centre Tel: +44 20 8996 7004 Email: knowledgecentre@bsigroup com Copyright & Licensing Tel: +44 20 8996 7070 Email: copyright@bsigroup com BSI Group Headquarters 389 Chiswick H igh Road Lond on W4 4AL U K

Ngày đăng: 13/04/2023, 20:05

Xem thêm: