information on ph measurement

48 191 0
information on ph measurement

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

J Information on pH measurement Analytical Measurement Contents 1 Preface _____________________________________________ 5 2 Basics ______________________________________________ 6 2.1 General _____________________________________________________ 6 2.2 Electrochemical pH measurement ______________________________ 8 2.2.1 pH measurement electrodes ______________________________________________ 8 3 Measurement ______________________________________ 15 3.1 Arrangement of a process measurement setup __________________ 15 3.1.1 Electrode ______________________________________________________________ 15 3.1.2 Fittings ________________________________________________________________ 17 3.1.3 Shielded instrument cable _______________________________________________ 17 3.1.4 Transmitter/controller ___________________________________________________ 17 3.2 Commissioning the measurement setup ________________________ 18 3.2.1 Measurement location___________________________________________________ 18 3.2.2 Measurement conditions ________________________________________________ 18 3.2.3 Installation_____________________________________________________________ 20 3.2.4 Calibration_____________________________________________________________ 20 3.2.5 Buffer solutions ________________________________________________________ 20 4 Quality assurance __________________________________ 22 4.1 How accurate is the pH measurement? ________________________ 22 4.2 Documentation _____________________________________________ 22 4.3 Maintenance ________________________________________________ 24 4.3.1 Critical effects on the reference electrode__________________________________ 27 4.3.2 Critical effects on the pH electrode _______________________________________ 27 4.4 Cleaning ___________________________________________________ 28 4.5 Calibration __________________________________________________ 28 4.6 Storage of the electrode ______________________________________ 28 5 Applications _______________________________________ 29 5.1 Waste-water treatment plants _________________________________ 29 5.1.1 Inlet to the plant ________________________________________________________ 30 5.1.2 Biotower ______________________________________________________________ 30 5.2 Swimming pools ____________________________________________ 32 5.3 Electroplating plants _________________________________________ 34 5.3.1 Electroplating baths_____________________________________________________ 34 5.3.2 Decontamination _______________________________________________________ 35 5.4 Power stations ______________________________________________ 37 5.5 Drinking water supply systems ________________________________ 38 5.6 Drinking water reservoirs _____________________________________ 39 Contents 6 Other methods of pH measurement _________________ 40 6.1 Electrochemical methods ____________________________________ 40 6.2 Optical methods ____________________________________________ 42 7 Legal aspects ______________________________________ 43 7.1 EU Directives _______________________________________________ 43 8 Closing remarks ___________________________________ 44 9 Source information _________________________________ 45 Information on pH measurement 5 1 Preface The pH value is the most frequently used process variable in analysis. The pH value is of outstanding importance in water and environmental analysis and in almost all sectors of industry. Whether the cheese in a dairy is of the right quality, the water in a drinking water supply causes corrosion damage, or the precipitation in a treatment plant for waste water from an electroplating pro- cess occurs at the optimal point, all depend on such parameters as the pH value. This technical publication presents the basic electrochemical relationships and typical applications in a general, easily understood form. In addition, informa- tion is provided on the current state of technology with regard to transmitters/ controllers and sensors for this process variable. We try to ensure that the “Information on pH measurement” is always kept fully up to date, and therefore appeal to our readers for feedback and the sharing of experience and knowledge. Any suggestions or contributions to the discus- sion will be most welcome. Fulda, May 2003 Dipl Ing. (FH) Matthias Kremer Dr. Peter John Product Line Manager Head of Development JUMO Analytical Measurement JUMO Analytical Measurement M.K. Juchheim, Fulda, Germany, May 2003 Reproduction permitted with source acknowledgement ! Part No. 00403231 Book No. FAS622 Printed 05.03 Information on pH measurement 6 2 Basics 2.1 General pH is derived from the Latin pondus hydrogenii (weight of hydrogen) or poten- tia hydrogenii (effectiveness of the hydrogen). Hydrogen ions So the pH value concerns hydrogen, or more precisely hydrogen ions 1 . Hydro- gen ions occur in water and aqueous solutions as a result of the dissociation of acid or water molecules. Pure water dissociates (splits) into hydrogen ions (H + ) and hydroxide ions (OH - ). At room temperature, the minute quantity of 10 -7 mol/l of hydrogen ions is present, corresponding to 0.0000001 g in one liter of water. An acid contains much larger quantities of hydrogen ions. The hydrogen chlo- ride molecule in hydrochloric acid dissociates 100 percent into hydrogen ions and chloride ions (Cl - ). Hydrochloric acid (HCl) with a concentration of c (HCl) = 1 mol/l contains 1 g/l hydrogen ions, that is 10 million times more than pure water. The presence of dissolved alkalis also affects the quantity of the hydrogen ions in the aqueous solution. Sodium hydroxide in caustic soda (NaOH) splits almost 100 percent into sodium (Na + ) and hydroxide ions. The more hydroxide ions are present, the smaller is the proportion of dissoci- ated water molecules. Caustic soda with a concentration c (NaOH) = 1 mol/l contains 0.00000000000001 g/l hydrogen ions, that is 10 million times less than pure water, but the hydroxide ion concentration is 10 million times larger. The more hydrogen or hydroxide ions a solution contains, the more aggres- sively it reacts. 1 It has been known since 1924 that hydrogen ions do not exist in aqueous solutions. The real causes of pH are oxonium and hydronium ions. How- ever, the term “hydrogen ions” is so widespread that it is normally used instead of the terms “oxonium ions” or “hydronium ions”. H 2 O → H + + OH - HCl → H + + Cl - NaOH → Na + + OH - Information on pH measurement 7 pH value The figures for the hydrogen ion concentration are very impractical and confus- ing. Sörensen simplified this by introducing the concept of pH in 1909. He sim- ply used the negative value of the common logarithm (base 10) of the hydrogen ion concentration. pH scale The pH values of aqueous solutions can be arranged in a pH scale. This scale ranges from strongly acidic to strongly basic (alkaline) solutions. Acidic Solutions with a pH value less than 7 are acidic; they contain more hydrogen ions than hydroxide ions. Neutral Solutions with a pH value of 7 2 are neutral; they contain equal quantities of hydrogen and hydroxide ions. Basic Solutions with a pH value more than 7 are basic (alkaline); they contain less hydrogen ions than hydroxide ions. Activity The effect of the hydrogen ions does not depend on their concentration but on their activity. Solutions with the same hydrogen ion concentration can have different levels of aggressiveness. The reason for this is the mutual interference of all the ions dissolved in the solution. For example, sulfate ions in sulfuric acid affect hydrogen ions differ- ently from nitrate ions in nitric acid. A chloride concentration c (Cl - ) = 100 g/l affects the hydrogen ions more strongly than a chloride concentration of c (Cl - ) =1 g/l. The valid definition of the pH used today no longer refers to the concentration of the hydrogen ions, but instead to their activity. Definition "pH is defined as the common logarithm of the molar hydrogen ion activity a H , multiplied by (-1), divided by the unit of the molality m 0 = 1 mol kg -1 ". This definition is valid for hydrogen ion activities from 10 0 to 10 -14 mol/l, that is for a range from pH = 0 to pH = 14. 2 The precise neutral point depends on the temperature. Hydrogen ion concentration Exponential representation pH value 0. 000 000 000 001 mol/l 10 -12 mol/l 12 0. 000 000 1 mol/l 10 -7 mol/l 7 1 mol/l 10 0 mol/l 0 Hydrochloric acid Water Caustic soda 01234567891011121314 acidic neutral basic (alkaline) Information on pH measurement 8 2.2 Electrochemical pH measurement The pH value can be measured in a number of very different ways: colorimet- ric, photometric or electrochemical (see Chapter 6). When choosing a method, it is well known that the pH value is one of those process variables where the measurement result depends on the measurement method used. Different measurement methods can lead to different measurement results that are, in principle, all correct. To avoid any confusion arising as a result of this, national and international standards stipulate that the pH value must be measured electrochemically with a glass electrode. As a result, the electrochemical mea- surement principle is the basis of all standardized methods of pH measure- ment. There has only been a globally valid agreement for the pH value since 1999 (IUPAC, Provisional Recommendations). This was made possible when England gave up its own pH scale in favor of the Bates-Guggenheim conven- tion used in every other country. Until then, Ireland and many Asiatic countries had used the English pH scale. 2.2.1 pH measurement electrodes The sensor for the measurement is the pH electrode system. It consists of two electrochemical half-cells, the measuring electrode and the reference elec- trode. At the measuring electrode, hydrogen ions establish a potential that depends on the pH value of the measured solution. The potential of the refer- ence electrode is unaffected by the pH value and remains constant. The differ- ence between the two potentials determines the electrical signal of the sensor, it is the electrode system voltage. Measuring circuit Fig. Arrangement of the pH measuring circuit The pH measurement is made: ❏ with a glass electrode (measuring electrode) with a pH-sensitive membrane Information on pH measurement 9 glass and a reference electrode with a potential that is as independent as possible of pH and temperature, ❏ or with a combination electrode (glass and reference electrodes combined in a single assembly). In practice, these two electrodes are incorporated in a more convenient com- bination electrode. Fig. pH electrodes pH electrode Reference electrode pH combination electrode Electrode head Internal conductive system Internal electrolyte Glass membrane Filler opening Ag / AgCl conductive system Diaphragm Electrode head Filler opening Reference conductive system Reference electrolyte Diaphragm Internal electrolyte Glass membrane Internal conductive element Information on pH measurement 10 Nernst equation Fig. Characteristic of a pH electrode system The relationship between pH and voltage is described by the Nernst equation: ∆E electrode system voltage E 0 standard voltage of the reference electrode R universal gas constant T absolute temperature n valency number of the hydrogen ions: n = 1 F Faraday constant a 1 activity of the hydrogen ions in the measured solution a 2 activity of the hydrogen ions in the internal buffer (constant) In practice, the expression is called the Nernst voltage (k) and represents the theoretical slope of a pH electrode system. At a temperature of 25°C, this corresponds to a voltage change of -0.059 V or -59 mV per logarithm to the base ten (pH unit). Substituting this in the Nernst equation and then summarizing gives the fol- lowing equation: pH pH of the measured solution pH 0 pH coordinates of the system zero k´ actual slope (determined during the calibration) The system zero corresponds to the pH at which electrode voltage E = 0 mV. ∆E = E 0 - R • T • ln a 2 n • Fa 1 ∆E = k´ • ( pH - pH 0 ) Characteristic Voltage Zero: approx. pH 7 pH value Slope: approx. -59 mV/pH R • T • 2.303 F [...]... the connector 28 Information on pH measurement 5 Applications pH measurements are found in all areas of technology and environmental protection Depending on the application, the measurement takes place in the laboratory, on- site with a hand-held meter, or continuously, in a process environment, for example The following practical applications should be considered in more detail Measurement of the pH. .. proof of the condition of the measurement setup and, of course, the measured product Measurements collected over a longer period of time are a good basis upon which to make decisions, for example: ❏ on maintenance of the measurement setup ❏ on control of the water parameters 22 Information on pH measurementon troubleshooting in the event of a fault ❏ or for the acquisition of new measurement equipment... 34 Information on pH measurement 5.3.2 Decontamination Cyanide decontamination The removal of cyanides from waste water is another example of the industrial application of a pH measurement Waste water containing cyanides is treated in continuous-flow treatment plants These plants consist of the following components: - reactor (vessel) - mixer (stirrer) - measurement and control system (acquisition... setup 3.2.1 Measurement location The choice of an optimal measurement setup is followed by the commissioning This includes not only the installation of the measurement setup, but also the choice of the correct measurement location The measurement setup only indicates the pH value prevailing at the location of the measurement at the time Recommendations for selection of the measurement location are given... cases the substances contained or the physical conditions subject the sensors that are used to stress ❏ A corrosive atmosphere affects the electronic part of the measurement setup ❏ Maintenance work must be possible even under tough conditions 29 Information on pH measurement In Germany the ATV specifications are available for analysis in water pH measurement is described in specification M 256 5.1.1 Inlet... operating instructions and other specifications and 23 Information on pH measurement instructions must be filed in the documentation folder 4.3 Maintenance The ageing of a measurement setup, and particularly electrodes, is dependent on the measurement conditions Wear and contaminants restrict its reliability and cause deviations Regular calibration helps to detect unreliable components and to restore... production 30 Information on pH measurement Measurement setup Permanent pH monitoring can realistically only be achieved with a sensor mounted direct in the main pipeline, i.e a fixed measurement setup The sensor is exposed to increased stress with these measurements: ❏ A high solids content in the sludge leads to heavy contamination ❏ Excess pressure stresses the reference system of the pH measurement. .. too low pH values, acids attack the pool material, and, for their part too, reduce the effect of the flocculation agent and increase the formation of combined chlorine (chloramines) pH value Effect Skin irritation 8.5 Lime turbidities 8.0 Impaired Al-flocculation 7.5 7.0 Indoor swimming pool odor 6.5 Corrosion phenomena 6.0 Impaired flocculation 32 Information on pH measurement Measurement A pH control... surface contact with the measured solution, via the annulus of a teflon ring, for instance The teflon ring in combination with an electrolyte gel is the ideal design, for example, for measurements in waste water or contaminated surface waters 14 Information on pH measurement 3 Measurement Until now, the basis of pH measurement has been the glass electrode It is the method of the national and international... decontamination is concluded within 20 minutes at most However, the licensing authorities insist on durations of between 40 and 60 minutes, to ensure that all the cyanide was converted In the last section, the cyanate obtained above is oxidized to carbonic acid and nitrogen at pH values around 7-8 This reaction is completed within 30 35 Information on pH measurement minutes (reaction 3) When the decontamination . terms “oxonium ions” or “hydronium ions”. H 2 O → H + + OH - HCl → H + + Cl - NaOH → Na + + OH - Information on pH measurement 7 pH value The figures for the hydrogen ion concentration are. plastic body Conductive system Electrolyte Diaphragm Information on pH measurement 14 As with the membrane, the optimal dia- phragm also depends on the particular application. Ceramic diaphragms consist of. contain less hydrogen ions than hydroxide ions. Activity The effect of the hydrogen ions does not depend on their concentration but on their activity. Solutions with the same hydrogen ion concentration

Ngày đăng: 09/05/2014, 17:01

Từ khóa liên quan

Tài liệu cùng người dùng

Tài liệu liên quan