1. Trang chủ
  2. » Thể loại khác

Huba product overview

20 246 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Nội dung

The Minneapolis Honeywell Regulator Company published the first edition of the Engineering Manual of Automatic Control in l934. The manual quickly became the standard textbook for the commercial building controls industry. Subsequent editions have enjoyed even greater success in colleges, universities, and contractor and consulting engineering offices throughout the world. Since the original 1934 edition, the building control industry has experienced dramatic change and made tremendous advances in equipment, system design, and application. In this edition, microprocessor controls are shown in most of the control applications rather than pneumatic, electric, or electronic to reflect the trends in industry today. Consideration of configuration, functionality, and integration plays a significant role in the design of building control systems. Through the years Honeywell has been dedicated to assisting consulting engineers and architects in the application of automatic controls to heating, ventilating, and air conditioning systems. This manual is an outgrowth of that dedication. Our end user customers, the building owners and operators, will ultimately benefit from the efficiently designed systems resulting from the contents of this manual. All of this manual’s original sections have been updated and enhanced to include the latest developments in control technology. A new section has been added on indoor air quality and information on district heating has been added to the Chiller, Boiler, and Distribution System Control Applications Section. This twenty-first edition of the Engineering Manual of Automatic Control is our contribution to ensure that we continue to satisfy our customer’s requirements. The contributions and encouragement received from previous users are gratefully acknowledged. Further suggestions will be most welcome. Minneapolis, Minnesota October, 199

FOR FINE PRESSURE AND FLOW MEASUREMENT Pressure sensor technology from mbar … 1000 bar Huba Control develops, manufactures and markets components designed exclusively for the measurement of pressure With its clear focus on pressure measurement technology Huba Control is able to develop innovative products across a very broad spectrum, covering an extensive range of applications for the optimisation of machine, system and plant processes Sales engineers at the headquarters in Switzerland, in our own branch offices in Germany, France, Great Britain and Netherlands as well as representatives all over the world guarantee the optimum in technical advice Market performance Production competence Huba’s production department is designed for the assembly, setting and adjustment of pressure switches and pressure transmitters The individual stages of the process are carried out with varying degrees of rationalisation A key strength is our expertise in complex automated production processes, including automatic calibration Quality Philosophy Huba Control has been accredited to ISO 9001 since 1995, and complies with the automotive standard ISO/TS 16949 The philosophy of our employees is: «I steadily improve and aspire to make no mistakes.» Product types 5 6 11 13 10 10 10 11 Pressure transmitters 0… – mbar OEM 0… – mbar OEM 0… 10 – 50 mbar OEM 0… – 50 mbar – 0.5 … 0.5 – 50 mbar 0… – 50 mbar … 50 – 1000 mbar … 20 – 2000 mbar 0… bar OEM … 2.5 – 10 bar OEM … 2.5 – 25 bar OEM –1… – 16 bar OEM … 0.1 – 25 bar … 2.5 – 40 bar –1… – 60 bar –1… – 160 bar OEM –1… – 600 bar OEM –1… – 600 bar –1… – 600 bar OEM –1… – 600 bar … 0.1 – 1000 bar ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 700 681 18 18 Level sensing pressure transmitters 0.8 … 1.4 – 10 bar OEM … 0.1 – 25 bar 15 14 14 15 Electronic pressure switches … 0.1 – 25 bar –1… – 600 bar OEM –1… – 600 bar –1… – 600 bar ■ ■ ■ ■ 605 604 620 610 630 625 16 16 17 16 17 17 Mechanical pressure switches 0.2 … mbar OEM 0.2 … 50 mbar 2… 220 mbar – 320 … 500 mbar … 5500 mbar – 900 … + 6000 mbar ■ ■ ■ ■ ■ ■ 509 513 13 13 –1… –1… Pressure measuring cells – 60 bar OEM – 160 bar OEM ■ ■ 200/201 18 0.5 … 800 801 19 19 240 Flow sensors l/min OEM Digital indicating devices ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Refrigerants Liquids ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Flammable gases ■ ■ ■ 616 511 615 619 Air and neutral gases 401 403 400 402 694 698 652 663 505 504 503 516 692 501 506 510 500 507 511 691 680 Medium Differential Pressure Absolute Page Relative Type ■ ■ ■ ■ ■ ■ ■ ■ Huba competence in the field of ultra-fine pressures OEM Type 400 Pressure transmitters Relative … 10 – 50 mbar Type 400 pressure transmitters are specially designed for large-scale production, and are ideally suited for continuous level measurement in vessels (white products) Medium Power supply Output Accuracy Electrical connection Pressure connection Manufacturing is fully automated, including in-line zero point and end value calibration Liquids and gases VDC 0.5 3.5 VDC < 0.3% fs Connector RAST 2.5 (AMP DUOPLUG 2.5™) Hose connector Ø 6.2 mm Snap-mounting OEM Type 401 Relative and differential … – mbar Type 401 pressure transmitters sense ultra-fine changes in air pressure, and are designed to provide optimum control Medium Power supply Output Accuracy Electrical connection Pressure connection The dual-component diaphragm, with it’s unique geometry, gives highly sensitive operation and excellent repeatability, even in the range below 20 Pascals Air and neutral gases 10.4 … 28 VDC 0.5 4.5 VDC < 0.3% fs Connector RAST 2.5 (AMP DUOPLUG 2.5™) Hose connector Ø 6.2 mm Snap-mounting or mounting bracket OEM Type 403 Relative and differential … – mbar Type 403 pressure transmitters sense ultra-fine changes in gas pressure for use in air / gas ratio control systems All materials used are compatible with flammable gas Medium Power supply Output Accuracy Electrical connection Pressure connection When used in combination with our type 401 pressure transmitter, the optimum air / gas ratio can be achieved Flammable gas 10.4 … 28 VDC 0.5 4.5 VDC < 0.5% fs Connector RAST 2.5 (AMP DUOPLUG 2.5™) Hose connector Ø 6.2 mm Snap-mounting or mounting bracket Pressure transmitters Type 402 Huba competence in the field of ultra-fine pressures Relative and differential … – 50 mbar Type 402 pressure transmitters are ideally suited to measuring fine air flow in air conditioning systems, and fine pressures in the environmental / medical technology sectors Medium Power supply Output Accuracy Electrical connection Pressure connection Location is quick and easy, either via a mounting plate or directly onto a PCB Mounting plates are available for mounting rail system TS35, or the adaptor plate which is compatible to the previous product ranges 696/697 Air and neutral gases 10.2 … 33 VDC 0.5 4.5 VDC < 0.6% fs Connector RAST 2.5 (AMP DUOPLUG 2.5™) Pins for PCB mounting Hose connector Ø 6.2 mm Snap-mounting or screw mounting Type 694 Relative and differential –0.5 … 0.5 – 50 mbar Type 694 pressure transmitters are available with or without integral digital display Adjustment of output signals 0…10V / 4…20mA are also available, as well as square root extraction Medium Power supply Output Accuracy Electrical connection Pressure connection Individually ranged sensors ensure optimum accuracy and long term stability of measurement, and the variety of options means great flexibility, not only in climate control, but also in industrial and medical fine pressure measurement Air and neutral gases 3-wire 13.5 … 33 VDC / 24 VAC 2-wire 11.0 … 33 VDC 10 VDC / 20 mA / 20 mA < 0.6% fs Screw terminals Hose connector Ø 6.2 mm Screw mounting Type 698 Relative and differential … – 50 mbar The pressure modules type 698 are specially suited to monitor air flows and differential pressure in air conditioning systems Medium Power supply Output Accuracy Electrical connection Pressure connection Screw mounting The module is optionally available with a digit indicator, two limit value switches (potential-free) as well as a squareroot extraction Air and neutral gases 24 VAC/DC or 230 VAC 10 VDC / 20 mA / 20 mA < 0.6% fs Screw terminals Hose connector conical mm Differential transmitters for higher pressures Type 652 Pressure transmitters Relative and differential … 50 – 1000 mbar Type 652 pressure transmitters are ideally suited to the continuous monitoring of liquid and gas flow (or level) in heating, ventilation and process technology Medium Power supply Output Accuracy Electrical connection Pressure connection Their especially rugged construction allows a single port over-pressure of up to 20 bar, depending upon pressure range Liquids and gases 20 … 30 VDC or 24 VAC 10 VDC / 20 mA / 20 mA < 3.0% fs Screw terminals Inside thread G1⁄8 Mounting bracket for screw mounting Type 692 Relative and differential … 0.1 – 25 bar Type 692 pressure transmitters have a unique, well proven, ceramic technology There are a variety of pressure and electrical connections available, together with several standardised output signals Medium Output VDC / 20 mA 10 VDC Accuracy Electrical connection Pressure connection The wide variety of options makes these transmitters ideal for applications across a broad spectrum of industries Liquids and gases Power supply 11 … 33 VDC 18 … 33 VDC / 24 VAC < 0.5% fs Cable 1.5 m, Connector DIN EN 175301-803-A Round plug connector DIN EN 60130-9 Hose connector or screw fittings Mounting bracket for screw mounting OEM Type 504 Relative and differential … 2.5 – 10 bar Type 504 pressure transmitters have laser adjusted hybrid electronics, and a unique ceramic measuring element which has the medium in contact with Medium Output Ratiometric 10 … 90% VDC / VDC 20 mA 10 VDC Accuracy Electrical connection Pressure connection both sides This ensures precise measurement without any calculation error There are various pressure and electrical connections at your disposal Liquids and gases Power supply VDC (4.75 … 5.25) 11 … 33 VDC 11 … 33 VDC 18 … 33 VDC < 0.4% fs Cable 1.5 m, connector DIN EN 175301-803-A Hose connector or screw fittings Mounting bracket for screw mounting Pressure transmitters OEM Type 500 Relative –1 … – 600 bar, Absolute … 2.5 – 16 bar Type 500 pressure transmitters have proven ceramic technology to give a calibrated and amplified sensor signal, available in a range of standardised voltage or current outputs Medium Output Ratiom 10 … 90% VDC / VDC 10 VDC … 20 mA Accuracy Electrical connection Pressure connection Type 501 Liquids and gases Power supply VDC (4.75 … 5.25) 11 … 33 VDC 18 … 33 VDC 11 … 33 VDC < 0.4% fs Cable 1.5 m, connector DIN EN 175301-803-A, Round plug connector M12x1 Inside and outside thread G1⁄4 Relative … 2.5 – 40 bar, Absolute … 2.5 – 16 bar Type 501 pressure transmitters, with partially automated production processes, are suitable for larger quantity industrial OEM applications Medium Output Ratiom 10 … 90% VDC … VDC 10 VDC … 20 mA Accuracy Electrical connection Pressure connection OEM Type 503 Various pressure and electrical connections, together with several standardised output signals, provide suitability for a wide variety of applications Liquids and gases Power supply VDC (4.75 … 5.25) … 33 VDC 10.4 … 33 VDC 16.2 … 33 VDC … 33 VDC < 0.5% fs Cable 1.5 m, connector DIN EN 175301-803-A or C Inside and outside thread G1⁄4 Relative … 2.5 – 25 bar Type 503 pressure transmitters, with their excellent price / performance ratio, are specially designed for industrial OEM applications Medium Output 0.5 2.5 VDC 0.5 3.5 VDC Accuracy Electrical connection Pressure connection These transmitters are ideally suited to various industrial applications in high quantities due to their rugged construction and laser adjustment Partially automated production techniques allow us to produce high quantities, yet retaining the flexibility to offer different versions Liquids and gases Power supply VDC (4.5 … 5.5) 8.5 … 30 VDC < 1.0% fs Cable 1.5 m, connector DIN EN 175301-803-A, Connector RAST 2.5 (AMP DUOPLUG 2.5™) Outside thread G3⁄8, plug connector Ø 15 mm Pressure transmitters OEM Type 505 Relative … bar Type 505 pressure transmitters are particularly suitable for measuring water pressure rates in heating and industrial circular flow Medium Output Ratiom 0.5 3.5 VDC 0.5 3.5 VDC Accuracy Electrical connection Pressure connection Type 506 Liquids and gases Power supply VDC (4.75 … 5.25) 8.5 … 30 VDC < 1.0% fs Connector RAST 2.5 (AMP DUOPLUG 2.5™) Outside thread G3⁄8, plug connector Ø 15 mm Relative –1 … – 60 bar for refrigeration applications Type 506 pressure transmitters are suitable for different applications in the field of industrial refrigeration due to it’s application specific pressure connections Medium Output Ratiom 10 … 90% VDC … VDC 10 VDC … 20 mA Accuracy Electrical connection Pressure connection Type 507 Due to partially automated manufacturing we are able to handle customer orders in high quantities Partially automated manufacturing allows the efficient production of high quantities, resulting in an excellent price / performance ratio Refrigerants Power supply VDC (4.75 … 5.25) … 33 VDC 10.4 … 33 VDC 16.2 … 33 VDC … 33 VDC < 0.5% fs Connector DIN EN 175301-803-A or C, cable 1.5 m Outside thread 7⁄16-20 UNF, 1⁄4-18 NPT Inside thread 7⁄16-20 UNF Relative –1 … – 600 bar, Absolute … 2.5 – 16 bar Type 507 pressure transmitters can be produced individually from single pieces to medium sized production batches Medium Output VDC VDC 10 VDC … 20 mA Accuracy Electrical connection Pressure connection The wide variety of versions and large number of pressure ranges allow many different applications Additionally, customers have the option of zero point and slope adjustment Liquids and gases Power supply 11 … 33 VDC 11 … 33 VDC 18 … 33 VDC / 24 VAC 11 … 33 VDC < 0.3% fs Connector DIN EN 175301-803-A, cable 1.5 m Inside and outside thread G1⁄4, G1⁄4 manometer combi Pressure transmitters OEM Type 510 Relative –1 … – 160 bar for refrigeration applications Type 510 pressure transmitters are suitable for use with all types of refrigerants, including ammonia Medium Output Ratiometr 10 … 90% VDC / VDC 10 VDC 20 mA Accuracy Electrical connection Pressure connection OEM Type 511 Refrigerants Power supply VDC (4.75 … 5.25) … 33 VDC 12.3 … 33 VDC / 24 VAC … 33 VDC < 0.5% fs Cable 1.5 m, Quickon, round plug connector M12x1, connector DIN EN 175301-803-C Outside thread 7⁄16-20 UNF, 1⁄4-18 NPT, R1⁄4, G1⁄4 Inside thread 7⁄16-20 UNF, G1⁄4 Relative –1 … – 600 bar, Absolute … – 25 bar Type 511 pressure transmitters meet the highest specifications for longevity, accuracy, temperature stability and Medium Output Ratiometr 10 … 90% VDC / VDC 10 VDC 20 mA Electric strength Accuracy Electrical connection Pressure connection Type 691 EMC characteristics, making them suitable for an extremely wide range of demanding industrial applications Liquids and gases Power supply VDC (4.75 … 5.25) … 33 VDC 11.4 … 33 VDC / 24 VAC … 33 VDC 500 / 1000 VDC < 0.3% fs Cable 1.5 m, Quickon, round plug connector M12x1, connector AMP, connector DIN EN 175301-803-C Outside thread G1⁄4, 1⁄4-18 NPT, R1⁄4, M12x1.5, M14x1.5 Inside thread G1⁄4 Relative –1 … – 600 bar, Absolute … 0.3 – 16 bar Type 691 pressure transmitters have a unique and well proven ceramic technology Medium Output VDC 10 VDC … 20 mA Accuracy Electrical connection Pressure connection 10 The newly designed pressure measuring cell incorporates a fully welded construction within the transducer housing Besides a wide range of pressure and electrical connections we are able to provide many pressure ranges from 300 mbar upwards Liquids and gases Power supply 11 … 33 VDC / 24 VAC 18 … 33 VDC / 24 VAC 11 … 33 VDC < 0.3% fs Cable 1.5 m, connector DIN EN 175301-803-A, Round plug connector DIN EN 60130-9 Outside thread G1⁄8, G1⁄4, G1⁄2, 7⁄16-20 UNF, 1⁄4 -18 NPT, ⁄2 -14 NPT Inside thread G1⁄4 Pressure transmitters Pressure transmitters with piezoresistive silicon pressure measuring cells Type 663 Relative / Absolute / Differential … 20 – 2000 mbar Type 663 pressure transmitters are designed for use with media such as air or non-aggressive gases Medium Power supply Output Accuracy Electrical connection Pressure connection The output signals are temperature compensated, linear and amplified Air and neutral gases 8.5 … 30 VDC 0.5 4.5 VDC < 0.5% fs Connector RAST 2.5 (AMP DUOPLUG 2.5™) or Pins for PCB mounting Hose connector Ø 4.8 mm, FESTO quick fitting Snap-mounting Type 680 Relative … 0.1 – 1000 bar, Absolute … 0.1 – 25 bar Type 680 pressure transmitters with piezoresistive silicon pressure measuring cells are available in over 20 pressure Medium Output VDC / 10 VDC … 20 mA / … 20 mA Accuracy Electrical connection Pressure connection Huba Control ranges, and with a wide variety of pressure and electrical connections Liquids and gases Power supply 15 … 30 VDC … 33 VDC < 0.5% fs (< 0.1% fs on request) Cable in several lengths, Binder 723, Lumberg RSF4, RSF50, connector DIN EN 175301-803-A, Outside thread G1⁄4, G1⁄2, , milk flange, DIN-flange, G1⁄4 pressure gauge, G1⁄2 pressure gauge Inside thread G1⁄4 Your qualified partner for over 60 years Open communication internally and externally Working in close partnership with our customers as the basis for a lasting, joint success 11 The excellent synergy of our unique diaphragm in combination with our ceramic cantilever beam sensors allows us to produce transmitters with long term stability for very fine measurement in the Pascal range This Cantilevered ceramic beam technology from Huba Control technology has been proven on over a million sensors in varying applications The in-house development and production of pressure measuring cells in combination with the excellent electronic design allows the production of innovative pressure transmitters Huba Control draws on over 10 years experience in the use of ceramic technology The products are proven million fold in various applications 12 Ceramic pressure measuring cell technology from Huba Control Pressure measuring cells OEM Type 509 Relative –1 … – 60 bar Type 509 pressure measuring cells are based on ceramic technology developed by Huba Control, and used for the last 10 years in millions of applications Due to the very robust design of the ceramic cell there are no significant changes in the sensor characteristics when mounted by the customer Power supply Zero point Range with nominal pressure Electrical connection OEM Type 513 … 30 VDC (–0.1 ± 0.1) mV / V (2.5 ± 1.5) mV / V Flexible connector contact spacing 2.54 mm, Bondpads (AgPd) contact spacing 1.27 mm Relative –1 … – 160 bar, Absolute … – 25 bar Type 513 pressure measuring cells have a calibrated, amplified sensor signal They are especially suitable for high quantities in OEM applications Power supply Output Accuracy Electrical connection OEM Type 516 The passivated surface passes the condensation test in accordance with DIN 50017 The unique integrated electronics allow installation without the need for temperature and pressure adjustment by the customer VDC (4.75 … 5.25) ratiometric 0.5 … 4.5 VDC < 0.3% fs Flexible connector contact spacing 2.54 mm, connector contact spacing 1.27 mm Relative –1 … – 16 bar, Absolute … – 16 bar Being used in combination with a unique integrated electronic design gives the type 516 a high degree of accuracy for all temperature ranges Medium Power supply Output Accuracy Electrical connection Pressure connection This technology, with its amplified ratiometric output signal, allows direct assembly without the need of user temperature or pressure adjustment Liquids and gases VDC (4.75 … 5.25) ratiometric 0.5 … 4.5 VDC < 0.5% fs Flexible connector contact spacing 2.54 mm FESTO quick fitting 13 Electronic switches OEM Type 511 Relative –1 … – 600 bar, Absolute … – 25 bar Type 511 electronic pressure switches meet the highest demands for operational reliability, and are especially suited to demanding industrial applications Medium Power supply Upper switching point Lower switching point Switching contacts Switching capacity Accuracy Electrical connection Pressure connection Type 615 Liquids and gases … 33 VDC … 100% fs … 97% fs High-Side switch (PNP) N/C contact / N/O contact Low-Side switch (NPN) N/C contact / N/O contact High-Side switch 500 mA Low-Side switch 150 mA < 1.0% fs Cable 1.5 m, Quickon, connector AMP, Round plug connector M12x1 Outside thread G1⁄4, 1⁄4-18 NPT, R1⁄4, M12x1.5, M14x1.5 Inside thread G1⁄4 Relative –1 … – 600 bar, Absolute … 0.3 – 16 bar The switching points of the electronic pressure switch type 615 can be potentiometer adjusted by the customer, Medium Power supply Upper switching point Lower switching point Switching contacts Switching capacity Accuracy Electrical connection Pressure connection Huba pressure switches, sensors and transmitters make an important contribution to the preservation of our natural energy resources and the reduction of pollution 14 The switching points are factory set by laser adjustment or set in our factory Many different pressure and electrical connections offer a wide range of uses Liquids and gases 10 … 33 VDC, 24 VAC … 100% fs … 98% fs High-Side switch (PNP) N/C contact / N/O contact Low-Side switch (NPN) N/C contact / N/O contact 100 mA < 0.5% fs Cable 1.5 m, connector DIN EN 175301-803-A, Round plug connector DIN EN 60130-9 Outside thread G1⁄8, G1⁄4, G1⁄2, 7⁄16-20 UNF, 1⁄4 -18 NPT, ⁄2 -14 NPT Inside thread G1⁄4 Huba Control Electronic switches Type 616 Relative and differential … 0.1 – 25 bar The switching points of the electronic pressure switch type 616 can be potentiometer adjusted by the customer, or set in our factory Medium Power supply Upper switching point Lower switching point Switching contacts Switching capacity Accuracy Electrical connection Pressure connection Type 619 Many different pressure and electrical connections offer a wide range of uses Liquids and gases 10 … 33 VDC, 24 VAC … 100% fs … 98% fs High-Side switch (PNP) N/C contact / N/O contact Low-Side switch (NPN) N/C contact / N/O contact 100 mA < 0.5% fs Cable 1.5 m, connector DIN EN 175301-803-A, Round plug connector DIN EN 60130-9 Hose connection or screw fitting Relative –1 … – 600 bar The µP-regulated, programmable pressure transmitter type 619 has a robust industry design Parameters can easily be programmed with three different configuration menus with easy Medium Power supply Output Switching capacity Accuracy Electrical connection Pressure connection to operate operations keys All systems are equipped with a diagnostic function The big 4-digit LED-indication assures a good accuracy of reading Liquids and gases 17 … 33 VDC 10 VDC … 20 mA max 200 mA Digital output < 0.6% fs Round connector M12x1 Inside thread G1⁄4 Definition of accuracy Maximal negative or positive deviation of set-point Sum of linearity, hysteresis and repeatability at room temperature Detailed technical information according to the product specific datasheet www.hubacontrol.com 15 Mechanical pressure switches Type 604 Differential pressure switches Relative and differential 0.2 … 50 mbar The ideal pressure switch to control air flows in air conditioning and ventilation systems, but equally effective in industrial air monitoring applications Medium Electrical connection Pressure connection This product range, which is classified in pressure ranges, makes installation easy with features such as combibracket, screw terminals and snap-on cover Of unique benefit is the high adjustment accuracy resulting from individual scale engraving Air and neutral gases Screw terminals Flat connector (AMP connector) 6.3 or 4.8 mm Hose connector Ø 6.2 mm Inside thread G1⁄8 Mounting bracket or fastening clip OEM Type 605 Relative and differential 20 … 400 pascal Type 605 pressure switches are specially developed for use in gas fired heating systems There are more than 10 million switches in use worldwide, produced on a fully automated production line Medium Electrical connection Pressure connection High setting accuracy and reproducibility, combined with excellent reliability characterise a quality of switch above the industry norm Air and neutral gases Flat connector (AMP connector) 6.3 or 4.8 mm Hose connector Ø 6.2 mm Mounting bracket or fastening clip Type 610 Relative and differential –320 … 500 mbar Type 610 differential pressure switches are especially suited to the monitoring of non-flammable gases in general industrial equipment Medium Electrical connection Pressure connection Mounting bracket 16 Exemplary accuracy is maintained throughout the high pressure range of this switch Air and neutral gases Flat connector (AMP connector) 6.3 mm Hose connector Ø mm Mechanical pressure switches Type 620/25 Relative –900 … 6000 mbar Type 620 and 625 pressure switches, with 13 pressure ranges, are suitable for both liquids and gases Body materials are available in plastic, brass and aluminium, with a choice of NBR, FPM, EPDM and silicone diaphragms Medium Electrical connection Pressure connection Very high precision through finely tuned measurement stages and high long-term stability Rugged design and especially suitable for use in general industrial equipment construction, process technology and food automation Liquids and gases Screw terminals, flat connector (AMP connector) 6.3 mm Inside thread M5, hose connection Ø mm, Outside thread M12x1, G1⁄4, G1⁄8 Mounting bracket Type 630 Relative and differential … 5500 mbar The pressure switches type 630 are suitable for monitoring flow in sanitary piping/ heating installations or for level monitoring in general in process technology applications Medium Electrical connection Pressure connection Their especially rugged construction allows a single port over-pressure of up to 20 bar, depending upon pressure range Liquids and gases Screw terminals, flat connector (AMP connector) 6.3 mm Inside thread G1⁄8 Mounting bracket Optimazed diaphragm geometry technology from Huba Control Huba Control has over 40 years experience in the innovation of diaphragm geometries The optimised construction of polymer diaphragms produces excellent long term stability, and switching point reproducibility, acting in synergy with our own in house developed contact systems 17 Level pressure transmitter / Flow sensor Type 681 Relative … 0.1 – 25 bar Type 681 level sensing pressure transmitters have a piezo-resistive encased silicon measuring cell There are 13 pressure ranges from 100 mbar fs upwards available Medium Output VDC 10 VDC … 20 mA … 20 mA Accuracy OEM Type 700 Aggressive fluides, potable water Power supply 15 … 30 VDC 15 … 30 VDC … 33 VDC … 33 VDC < 0.5% fs (< 0.1% on request) Absolute 0.8 … 1.4 – 10 bar Type 700 level sensing pressure transmitters have a ceramic absolute pressure measuring cell Medium Power supply Output Accuracy OEM Type 200/201 They are specially designed for industrial OEM applications, and have an excellent price/ performance ratio Liquids VDC (4.75 … 5.25) ratiometric 10 90% < 0.5% fs Flow ranges from 0.5 … 240 l/min The flow sensor of this range is based on the principle of Karman’s vortex trail The shedding of vortices on the damming body in the flow is directly proportional to the speed of the flow Medium Power supply Output Electrical connection Nominal diameters 18 Atmospheric pressure compensation is ensured by a capillary tube in the cable A piezoelectric paddle detects the generated vortex and analyzes the values with the integrated electronic Liquids VDC (4.75 … 5.25) Square pulse frequency … 850 Hz Connector RAST 2.5 (AMP DUOPLUG 2.5™) DN6, DN8, DN10, DN15, DN20, DN25, DN32 Digital indicating devices Type 800 Indication in mbar and bar Type 800 digital indicators are equipped with a digit display, as well as optional switch and analogue outputs The sensor signal is evaluated and indicated as pressure by the digital display Power supply Input signals 24 VDC / AC, 230 VAC … VDC … 10 VDC … 20 mA … 20 mA … 10 VDC … 20 mA … 20 mA Potential-free limit value switch Output signals Type 801 Portable plug-in indicator Type 801 digital indicators are compatible with all sensors with DIN plug EN 175301-803-A Independent of the mounting position of the sensor, the display can be rotated to give the ideal reading position Input signals … VDC … 10 VDC … 20 mA … 20 mA Huba Control The programming of the limit value output can be executed with the buttons on the front or via a data cable from a computer The 801 has a digit liquid-crystal display which is adjustable by the customer, or available factory set Power supply 11 … 33 VDC, 24 VAC 18 … 33 VDC, 24 VAC 18 … 33 VDC, 24 VAC … 33 VDC In addition to our extensive range of standard products, we are able to develop and produce customer specific solutions designed to meet the demanding conditions required by manufacturers of OEM products 19 Huba Control United Kingdom Unit Network Point Range Road Witney Oxfordshire OX29 0YD Telefon++ 41 (0) 56 436 82 00 Telefax ++ 41 (0) 56 436 82 82 Phone 01 993 776 667 Fax 01 993 776 671 info.ch@hubacontrol.com info.uk@hubacontrol.com www.hubacontrol.com Huba Control France info.fr@hubacontrol.com Huba Control Germany info.de@hubacontrol.com Huba Control Netherlands info.nl@hubacontrol.com GENERAL / E / Edition 04/2006 Technical data subject to change Headquarters Huba Control AG Industriestrasse 17 CH-5436 Würenlos ... info.ch@hubacontrol.com info.uk@hubacontrol.com www.hubacontrol.com Huba Control France info.fr@hubacontrol.com Huba Control Germany info.de@hubacontrol.com Huba Control Netherlands info.nl@hubacontrol.com... excellent electronic design allows the production of innovative pressure transmitters Huba Control draws on over 10 years experience in the use of ceramic technology The products are proven million fold... range of standard products, we are able to develop and produce customer specific solutions designed to meet the demanding conditions required by manufacturers of OEM products 19 Huba Control United

Ngày đăng: 26/03/2014, 07:03

TỪ KHÓA LIÊN QUAN