24A7 E 0099a (Supplement to RS 485 User''''s Manual) FRENIC Ace CHAPTER 5 (C2) This document is a supplement to the “RS 485 Communication User’s Manual (24A7 E 0082, MEH448)”, and is comprised of section[.]
(Supplement to RS-485 User's Manual) FRENIC-Ace (C2) CHAPTER This document is a supplement to the “RS-485 Communication User’s Manual (24A7-E-0082, MEH448)”, and is comprised of section 5.2 (Data Format), to which content has been both added and changed For pages that are not included in this document, please refer to the “RS-485 Communication User’s Manual” to ensure correct use 24A7-E-0099a 5.2 Data Formats 5.2.1 List of data format numbers The following table shows the communications data format numbers for function code data Create data according to the data format specifications described below For the data setting range and setting unit, see the User's Manual of each inverter type (Chapter for FRENIC-Mini/Mini(C2)/Eco/Multi, and Chapter for FRENIC-Ace/MEGA.) The "Support" column of the table indicates whether each function is supported by the respective models or not Y indicates the function is supported, and N indicates the function is not supported RTU and FGI in the Format number field mean the Modbus RTU protocol and the Fuji general-purpose inverter protocol, respectively Table 5.17 List of data format numbers (F codes) Format number Code Name F00 F01 F02 F03 F04 F05 F06 F07 F08 F09 F10 Data Protection Frequency Command Operation Method Maximum Frequency Base Frequency Rated Voltage at Base Frequency Maximum Output Voltage Acceleration Time Deceleration Time Torque Boost Electronic Thermal Overload Protection for Motor (Select motor characteristics) (Overload detection level) F11 F12 F14 F15 F16 F18 F20 F21 F22 F23 F24 F25 F26 F27 (Thermal time constant) Restart Mode after Momentary Power Failure (Mode selection) Frequency Limiter (High) (Low) Bias (Frequency command 1) DC Braking (Braking starting frequency) (Braking level) (Braking time) Starting Frequency (Holding time) Stop Frequency Motor Sound (Carrier frequency) (Tone) Support Eco Multi Ace MEGA Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y [1] [1] [1] [3] [3] [1] [1] [12] [12] [3] [1] Mini Y Y Y Y Y Y Y Y Y Y Y [24] (FGI) Y Y Y Y Y [19] (RTU) [24]] (BUS) *1 [3] [1] Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y [3] [3] [6] [3] [1] [5] [3] [5] Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y [3] [1] *2 [1] Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y *1 BUS: The field bus option format is selected For details about the field bus option, see the instruction manual for each field bus option *2 The frequency of 0.75kHz will be treated as 5-1 Table 5.17 List of data format numbers (F codes) (Continued) Format number Code Name F29 Analog Output [FMA*1] (Mode selection) Analog Output [FM] (Mode selection) Analog Output [FMA*1] (Voltage adjustment) Analog Output [FM] (Voltage adjustment) Analog Output [FMA*1] (Function) Analog Output [FM] (Function) Analog Output [FM2] (Mode selection) Pulse Output [FMP] (Pulse rate) Analog Output [FM] (Pulse rate) *6 (Gain to output voltage) Pulse Output [FMP ] Analog Output [FM2] (Voltage adjustment) Pulse Output [FMP*6] (Function) Analog Output [FM2] (Function) Load Selection/Auto Torque Boost/Auto Energy Saving Operation Stop Frequency (Detection mode) (Holding time) Torque Limiter (Limiting level for driving) Torque Limiter 1-1 Torque Limiter (Limiting level for braking) Torque Limiter 1-2 Drive Control Selection F30 F31 F32 F33 F34 F35 F37 F38 F39 F40 F41 F42 F43 F44 F50 F51 F52 F80 Current Limiter (Mode selection) (Level) Electronic Thermal Overload Protection for Braking Resistor (Discharging capability) (Allowable average loss) (Resistance) Switching between HD MD and LD Drive Modes (MEGA) Switching between HD ND HHD and HND Drive Modes(Ace) *1 *2 *3 *4 *5 *6 *7 *8 Support Eco Multi Ace MEGA Y N N Y N Y Y N Y N N Y N Y Y N Y N N Y N Y Y N N N Y*8 Y*2 *3 Y N N Y*4 N Y Y N Y*3 N N Y*4 Y*5 N Y*8 N Y*3 N N Y*4 Y*5 N Y*8 N Y Y Y Y [1] [1] [1] [1] [1] [1] [1] [1] [1] [1] [1] [1] [1] [1] Mini N N Y N Y N N N N N N N N Y [1] [5] [1] [2] [1] [2] [1] N Y N N N N Y N N N N N N N N Y Y N Y N Y Y Y Y N Y N Y Y Y N Y N Y Y [1] [1] [1] *7 Y Y Y Y Y N Y Y Y Y Y Y Y Y Y [7] *7 [45] [12] [1] Y N N N N N N N Y N N N N Y Y Y Y N Y Y As for FRN□□G1□-□A, E and U the terminal name changes from FMA to FM1 Applicable only with FRN□□G1□-□A, E and U Not applicable with FRN□□□F1□-□A, E and U Not applicable with FRN□□G1□-□A, E and U Applicable only with FRN□□□F1□-□A, E and U As for FRN□□G1□-□A, E and U, the terminal name changes from FMP to FM2 The value of 999 will be treated as 7FFFH Applicable only with FRN□□E2□-□C, FRN□□E2□-□GB 5-2 Table 5.18 List of data format numbers (E codes) Format number Code Name E01 E02 E03 E04 E05 E06 E07 E08*1 E09*1 E10 E11 E12 E13 E14 E15 E16 E20 E21 E22 E23 E24 E27 E29 E30 E31 E32 E34 Terminal [X1] Function [X2] Function [X3] Function [X4] Function [X5] Function [X6] Function [X7] Function [X8] Function [X9] Function Acceleration Time Deceleration Time Acceleration Time Deceleration Time Acceleration Time Deceleration Time Torque Limiter (Limiting level for driving) Torque Limiter 2-1 Torque Limiter (Limiting level for braking) Torque Limiter 2-2 Terminal [Y1] Function [Y2] Function [Y3] Function [Y4] Function [Y5A/C] Function [30A/B/C] Function (Relay output) Frequency Arrival Delay Time Frequency Arrival (Hysteresis width) Frequency Detection (Level) (Hysteresis width) Overload Early Warning/Current Detection (Level) E35 E36 E37 Frequency Detection Current Detection /Low Current Detection (Timer) (Level) (Level) E38 E39 E40 E41 E42 E43 E44 E45 E46 E47 E48 E49 E50 (Timer) Coefficient for Constant Feeding Rate Time PID Display Coefficient A PID Display Coefficient B LED Display Filter LED Monitor (Item selection) (Display when stopped) LCD Monitor (Item selection) (Language selection) (Contrast control) LED Monitor (Speed monitor item) (Choise of the torque polarity) Coefficient for Speed Indication E17 [1] [1] [1] [1] [1] [1] [1] [1] [1] [12] [12] [12] [12] [12] [12] [1] [2] [1] [2] [1] [1] [1] [1] [1] [1] [5] [3] [3] [3] [24] (FGI) [19] (RTU) [24] (BUS) *2 [5] [3] [24] (FGI) [19] (RTU) [24] (BUS) *2 [5] [7] [12] [12] [3] [1] [1] [1] [1] [1] [1] [1] [5] Mini Y Y Y N N N N N N Y Y N N N N N N N N Y N N N N Y N Y Y Y Y Y N Y N Y Y N Y Y Y Y Y Y N Y Y Y Y N Y Support Eco Multi Y Y Y Y Y Y Y Y Y Y N N N N N N N N N Y N Y N N N N N N N N N Y N N N Y N N Y Y Y Y Y N N N Y N Y Y N Y N Y Y Y Y Y Y Y Y Y Y Y Y Y N N N Y N Y N Y N Y N Y Y Y Y Y N Y Y Y N N Y Y Y Y Y Y Y Y N N Y Y Ace MEGA Y Y Y Y Y Y Y Y Y Y N Y N Y N Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y N N Y Y N N Y Y Y Y Y N Y N Y N Y Y Y Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N N Y N Y Y Y Y Y Y Y N Y N Y N Y Y Y Y Y Y Y *1 Not applicable with FRN□□G1□-□A , E and U *2 BUS: The field bus option format is selected For details about the field bus option, see the instruction manual for each field bus option 5-3 Table 5.18 Code List of data format numbers (E codes) (Continued) Format number Name Support Eco Multi Ace MEGA Y Y Y Y E51 Display Coefficient for Input Watt-hour Data E52 Keypad (Menu display mode) [1] Y Y Y Y Y E54 Frequency Detection (Level) [3] N N N Y Y E55 Current Detection (Level) E56 E59 E60 E61 E62 (Timer) Switch Function of C1 Terminal Built-in Potentiometer (Function selection) Terminal [12] Extended Function Terminal [C1] Extended Function Terminal [C1] Extended Function (C1 function) Terminal [V2] Extended Function Terminal [C1] Extended Function (V2 function) Saving of Digital Reference Frequency Reference Loss Detection (Continuous running frequency) Direct Current Intermediate Voltage Detection Level Torque Detection (Level) (Timer) Torque Detection 2/Low Torque Detection (Level) (Timer) Terminal [FWD] Function [REV] Function [24] (FGI) [19] (RTU) [24] (BUS) *2 [5] [1] [1] [1] [1] [1] [1] [1] [1] [1] *3 [1] [1] [5] [1] [5] [1] [1] N N N N N Y Y Y N N N N N N N N N N Y Y N N N N N N Y Y N Y N Y Y N N N Y Y Y Y N N N N Y N Y N Y N Y N Y N N N N N Y Y Y Y Y Y Y N Y N Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y N N Y Y N Y N Y Y Y Y Y Y Y Y Y E63 E64 E65 E76 E78 E79 E80 E81 E98 E99 [45] Mini Y *2 BUS: The field bus option format is selected For details about the field bus option, see the instruction manual for each field bus option *3 The value of 999 will be treated as 7FFFH 5-4 Table 5.19 Code C01 C02 C03 C04 C05 List of data format numbers (C codes) Format number Name Jump Frequency Frequency Frequency (Hysteresis width) Multi-Frequency C06 C07 C08 C09 C10 C11 C12 C13 C14 10 C15 11 C16 12 C17 13 C18 14 C19 15 C20 Jogging Frequency C21 C22 Timer Operation/Pattern Operation Selection Pattern Operation Selection (Stage1) C23 (Stage2) C24 (Stage3) C25 (Stage4) C26 (Stage5) C27 (Stage6) C28 (Stage7) 5-5 [3] [3] [3] [3] [5] [22] [5] [22] [5] [22] [5] [22] [5] [22] [5] [22] [5] [22] [5] [22] [5] [22] [5] [22] [5] [22] [5] [22] [5] [22] [5] [22] [5] [22] [5] [22] [1] [84] [12] [84] [12] [84] [12] [84] [12] [84] [12] [84] [12] [84] [12] Mini Y Y Y Y N Y N Y N Y N Y N Y N Y N Y N Y N Y N Y N Y N Y N Y N Y N Y N Y Y N N N N N N N N N N N N N N Support Eco Multi Ace MEGA Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N N N N Y Y Y Y N N N N Y Y Y Y N N N N Y Y Y Y N N N N Y Y Y Y N N N N Y Y Y Y N N N N Y Y Y Y N N N N Y Y N Y N N N N Y Y N Y N N N N Y Y N Y N N N N Y Y N Y N N N N Y Y N Y N N N N Y Y N Y N N N N Y Y N Y N N N N Y Y N Y N N N N Y Y N Y N N N N Y Y N Y Y Y N N Y N N N N Y N N Y N N N N Y N N Y N N N N Y N N Y N N N N Y N N Y N N N N Y N N Y N N N N Y N N Y N N N N Y Table 5.19 List of data format numbers (C codes) (Continued) Code Name C30 C31 C32 C33 C34 C35 C36 Frequency Command Analog Input Adjustment for [12] C37 C38 C39 C40 C41 C42 C43 C44 C45 C50 C51 C52 C53 C55 C56 C58 C59 C60 C61 C62 C64 C65 C66 C67 C68 C70 C71 C72 Format number (Offset) (Gain) (Filter time constant) (Gain base point) (Polarity) Analog Input Adjustment for [C1] (Offset) Analog Input Adjustment for [C1] (C1 function) (Offset) Analog Input Adjustment for [C1] (Gain) Analog Input Adjustment for [C1] (C1 function) (Gain) Analog Input Adjustment for [C1] (Filter time constant) Analog Input Adjustment for [C1] (C1 function) (Filter time constant) Analog Input Adjustment for [C1] (Gain base point) Analog Input Adjustment for [C1] (C1 function) (Gain base point) Analog Input Adjustment for [C1] (C1 function) (Range selection) Analog Input Adjustment for [V2] (Offset) Analog Input Adjustment for [C1] (V2 function) (Offset) Analog Input Adjustment for [V2] (Gain) Analog Input Adjustment for [C1] (V2 function) (Gain) Analog Input Adjustment for [V2] (Filter time constant) Analog Input Adjustment for [C1] (V2 function) (Filter time constant) Analog Input Adjustment for [V2] (Gain base point) Analog Input Adjustment for [C1] (V2 function) (Gain base point) Analog Input Adjustment for [V2] (Polarity) Bias (Frequency command 1) (Bias base point) Bias (PID command 1) (Bias value) (Bias base point) Selection of Normal/Inverse Operation (Frequency command 1) Analog Input Adjustment for [12] (Bias) (Bias base point) (Display unit) (Maximum scale) (Minimum scale) Analog Input Adjustment for [C1](C1 function) (Bias) (Bias base point) (Display unit) (Maximum scale) (Minimum scale) Analog Input Adjustment for [V2](V2 function) (Bias) (Bias base point) (Display unit) (Maximum scale) (Minimum scale) 5-6 Support Eco Multi Ace MEGA Y Y Y Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N Y Y Y Y N N Y N Y Y N Y N N Y N Y Y N Y N N Y N Y Y N [1] [4] [5] [5] [5] [1] [4] [4] [5] [5] [5] [5] Mini Y N Y Y Y N N N Y N Y N [5] [5] Y N Y N N Y N Y Y N [1] Y N N Y Y [4] [4] [5] [5] [5] [5] N N N N N N Y N Y N Y N N Y N Y N Y N Y N Y N Y Y N Y N Y N [5] [5] N N Y N N Y N Y Y N [1] [5] [6] [5] [1] N Y Y Y N N Y Y Y Y N Y Y Y Y Y Y N N Y Y Y Y Y Y [6] [5] [1] [12] [12] [6] [5] [1] [12] [12] [6] [5] [1] [12] [12] N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N N N N N N N N N N N N N N N Table 5.19 List of data format numbers (C codes) (Continued) Format number Code Name C82 Rotatory Direction and Time of Speed Up and Slowing Down (Stage 1) (Stage 2) (Stage 3) (Stage 4) (Stage 5) (Stage 6) (Stage 7) Frequency Compensation (Numerator) Frequency Compensation (Denominator) Jump Frequency Frequency Frequency Multi-requency C83 C84 C85 C86 C87 C88 C89 C90 C94 C95 C96 C99 5-7 [1] Mini N [1] [1] [1] [1] [1] [1] [2] [2] [3] [3] [3] [22] N N N N N N N N Y Y Y Y Support Eco Multi Ace MEGA N N N Y N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N Y Y N N N N Y Y Y Y Y Y N N N N N N Table 5.20 List of data format numbers (P codes) Format number Name Code P03 (No of poles) (Rated Capacity) When P99 = 1(MEGA only) (Rated current) P04 P05 P06 (Auto-tuning) (Online Tuning) (No-load current) P07 P08 P09 P10 P11 P12 P13 P14 P15 P16 P17 P18 P19 P20 P21 P22 P23 P30 P53 P54 P55 (%R1) (%X) (Slip compensation gain for driving) (Slip compensation response time) (Slip compensation gain for braking) (Rated slip frequency) (Iron loss factor 1) (Iron loss factor 2) (Iron loss factor 3) (Magnetic saturation factor 1) (Magnetic saturation factor 2) (Magnetic saturation factor 3) (Magnetic saturation factor 4) (Magnetic saturation factor 5) (Magnetic saturation extension factor a) (Magnetic saturation extension factor b) (Magnetic saturation extension factor c) (PMSM drive Magnetic pole position detection mode) (%X correction factor 1) (%X correction factor 2) (Torque current under vector control) P56 P57 (Induced voltage factor under vector control) P01 P02 Motor Reserved [1] [11] [25] [24] (FGI) [19] (RTU) [24] (BUS) *1 [21] [1] [24] (FGI) [19] (RTU) [24] (BUS) *1 [5] [5] [3] [5] [3] [5] [5] [5] [5] [3] [3] [3] [3] [3] [3] [3] [3] [1] [1] [1] [24] (FGI) [19] (RTU) [24] (BUS) *1 Mini N Y N Y Y N Y N Y Y N Y Y Y Y Y Y N N N N N N N N N N N N N N N N N [1] [7] N N Support Eco Multi Ace MEGA Y Y Y Y Y Y Y Y N N N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N Y Y Y N Y Y Y N Y Y Y N Y Y Y N N Y Y N N N Y N N N Y N N Y Y N N Y Y N N Y Y N N Y Y N N Y Y N N N Y N N N Y N N N Y N N Y N N N Y Y N N N Y N N Y Y N N Y Y N N Y Y N N N N Y N Y Y *1 BUS: The field bus option format is selected For details about the field bus option, see the instruction manual for each field bus option 5-8 ... Data Formats 5.2.1 List of data format numbers The following table shows the communications data format numbers for function code data Create data according to the data format specifications... (Iron loss factor 3) (Magnetic saturation factor 1) (Magnetic saturation factor 2) (Magnetic saturation factor 3) (Magnetic saturation factor 4) (Magnetic saturation factor 5) (Magnetic saturation... unit) (Maximum scale) (Minimum scale) Analog Input Adjustment for [V2](V2 function) (Bias) (Bias base point) (Display unit) (Maximum scale) (Minimum scale) 5-6 Support Eco Multi Ace MEGA Y Y Y