1. Trang chủ
  2. » Ngoại Ngữ

Upgrading the ATLAS Level-1 Calorimeter Trigger using Topological Information

10 2 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 10
Dung lượng 1,71 MB

Nội dung

Upgrading the ATLAS Level-1 Calorimeter Trigger using Topological Information Yuri Ermolinea1 on behalf of the ATLAS TDAQ Collaboration [1] a Department of Physics and Astronomy, Michigan State University, BPS Building, East Lansing, MI 48824-2320, USA E-mail: Yuri.Ermoline@cern.ch ABSTRACT: The ATLAS Level-1 Calorimeter Trigger (L1Calo) is a fixed latency, hardwarebased pipelined system designed for operation at the LHC design luminosity of 10 34cm-2s-1 Plans for a several-fold luminosity upgrade will necessitate a complete replacement for L1Calo (Phase II) But backgrounds at or near design luminosity may also require incremental upgrades to the current L1Calo system (Phase I) This paper describes a proposed upgrade to the existing L1Calo to add topological algorithm capabilities, using Region of Interest (RoI) information currently produced by the Jet and EM/Hadron algorithm processors but not used in the Level-1 real-time data path KEYWORDS: Digital electronic circuits; Trigger concepts and systems (hardware and software) Corresponding author Contents 1.Summary 2.Introduction 3.Ideas on limited short-term topological upgrade 3.1Limitations of current system and possible improvement 3.2Modifications required for limited upgrade 3.3Common Merger Module modifications 4.Recent R&D towards CMM++ specification and design 4.1Backplane data transfer 4.2Latency survey 4.3Optical links study 4.4Technology study 4.5Firmware study Conclusion Summary The ATLAS Level-1 Calorimeter Trigger (L1Calo) [2] is a fixed latency hardware-based pipelined system The real-time data path includes the pre-processor that conditions and digitizes analog tower sums, and two parallel digital algorithm processor subsystems that separately produce detector-wide EM/hadron cluster and Jet/Energy-sum results to send to the Central Trigger Processor, which produces the final Level-1 trigger decision L1Calo was designed to cope with the LHC design luminosity and a complete replacement is being designed for the several-fold luminosity upgrade planned for the LHC Recent simulations suggest pile-up may pose challenges to the L1Calo even near the design luminosity, and trigger algorithms may need to be augmented to reduce rates and improve selectivity even before the current L1Calo is replaced A promising solution is to add topological algorithms based on the Region of Interest (RoI) information currently produced in the algorithm processors for use in Level-2, but not in the Level-1 real-time data path By modifying the firmware in the existing algorithm processor modules and running the existing backplane merger connections at a higher clock speed, this information can be included in the real-time data path and processed in real time The result-merging boards in the current system must be redesigned to include more modern programmable logic and high-bandwidth optical data links These boards will initially retain backward compatibility with the current system, but also enable topological algorithm processing to be added, either among the merging boards themselves or in a new, separate –1– topological processor subsystem (TP) The proposed upgrade may also require firmware changes in the CTP to increase the number of trigger inputs available Tests with the current L1Calo backplane and algorithm processor boards have shown the feasibility of expanding the real-time data path bandwidth Monte Carlo studies of the proposed topological algorithms are in progress, as is technical specification of the combined merger/ topological processor stage Modifications to the current Level-1 Calorimeter Trigger system shall be reversible and backward compatible, and allow early deployment and parasitic testing of some components of the Phase II system Introduction The L1Calo trigger (Figure 1) is a fixed-latency, 40 MHz pipelined digital system [2] Its input data comes from about 7200 analogue trigger towers of reduced granularity, mostly 0.1 × 0.1 in ∆η × ∆ φ , from all the ATLAS electromagnetic and hadronic calorimeters The L1Calo electronics has a latency of less than a microsecond, resulting in a total latency of about 2.1 µs for the L1Calo chain including cable transmission delays and the Central Trigger Processor (CTP) processing time Figure Architecture of the L1Calo trigger system The Cluster Processor (CP) identifies candidate electrons, photons and τ’s with high ET above programmable thresholds and, if desired, passing isolation requirements The Jet/Energysum Processor (JEP) operates on ‘jet elements’ at the somewhat coarser granularity of 0.2 × 0.2 in ∆η × ∆ φ to identify jets as well as produce global sums of total, missing, and jet-sum ET Both the CP and the JEP count ‘hit’ multiplicities of the different types of trigger objects, and send them, together with tower energy information (total and x,y components), to the two Common Merger Modules (CMMs) in each crate η is pseudo-rapidity and φ is azimuthal angle around the beam axis –2– The ‘crate’ CMMs (one at each end of the main block of modules in each crate) processes the results from the CPMs or JEMs to produce results over the entire crate, and send them to a ‘system’ CMMs in order to produce system-wide results These final results are sent on cables to the CTP Upon receiving the L1Accept signal from the CTP, the Region of Interest (RoI) information is sent to the Data Acquisition (DAQ) system through ReadOut Drivers (RODs) Ideas on limited short-term topological upgrade 3.1 Limitations of current system and possible improvement The present trigger capabilities allow to make selections on counts of objects of various types (for example jets > 40 GeV), and even separate counts of objects (eg MET > 50 GeV && jets > 40 GeV) However, there is presently no provision for spatial correlation of different objects, or for differentiating jets and em/tau clusters identified in the different subsystems but originating from the same energy deposits A possible solution could be to include jet/cluster position information (RoI) in the real time data path (in the current system it is available only for the DAQ system) and to use this information to add topology-based algorithms at Level For example, identification of spatial overlap between e/tau clusters and jets, usage of the local jet Et sum to estimate energy of overlapping e/tau objects and calculation of invariant transverse mass would be possible Some of them require only local information, others need global 3.2 Modifications required for limited upgrade For several years the calorimeter electronics and the trigger hardware up to and including the Cluster Processor Modules (CPMs) and Jet/Energy Modules (JEMs) will remain essentially unchanged The hardware components on which the system is built are about to years old and don’t allow much freedom for modifications; many parts are already obsolete A limited modification of the algorithm processor firmware can be done in order to extract the extra information, but in order to run topological algorithms a new module must be designed This module will replace the so-called “common merger” module (CMM) in the current system Figure Modifications required for limited upgrade In the proposed new architecture (Figure 2) the CP and JEP systems (and L1 Muon trigger processor) transmit additional RoI information (which is not currently used in the real-time data –3– path) taking advantage of the higher bandwidth potential inherent, but not used, in the backplane to the re-designed CMM module (CMM++) The data transfer rate over the crate backplane can be increased from 40 Mbit/s to 160 Mbit/s A topological processor (TP) that performs more sophisticated algorithms on the combined feature set and sends results to CTP can be added at later stage 3.3 Common Merger Module modifications The current CMM module [3] processes the results from the CPM or JEM modules to produce results over the entire crate, and send them to a “system” CMM in order to produce system-wide results These final results are sent on cables to the CTP A “crate” FPGA on each CMM receives backplane data and produces crate/wide sums of identified features A “system” FPGA collects crate results over LVDS cables and sends the trigger output to CTP On an L1A, data and ROI are sent via G-Links to the DAQ system All CMMs (Figure 3) have identical hardware and several different firmware variants to allow performance of different functions Figure Current Common Merger Module The current L1Calo trigger system must remain unchanged for the next few years and it would be desirable that the system modifications can be done and tested in parallel with the running system The CMM++ development scenario assumes that the module can be a drop-in replacement for the CMMs, with the ability to perform additional logic on top of providing all the necessary backwards compatible CMM functionality (Figure 4) –4– Figure Proposed CMM++ The two basic requirements are that this module should: • provide all the necessary functionality to replace a current CMM (electrical interfaces, programming model, data formats), • be able to transmit all the backplane data, received from upgraded CPM/JEM modules, onwards to the TP over optical links (with or without internal processing) and to receive the data via optical links in order to implement internal topology processing without TP A desirable extra feature would be that the module could perform extra processing (and possibly output extra trigger bits) which would act as a test bed for future trigger algorithms Development of such a module can be staged in the following way: • hardware design with all present interfaces plus optical links for the new topological processor, one large FPGA, adapt current CMM firmware to the new hardware for initial use, • upgrade CPM/JEM and CMM++ modules firmware for new data format and 160 Mb/s data transfer, incrementally add new functionality, CMM++ supplies data to the topological processor connected to the CTP Recent R&D towards CMM++ specification and design In order to prepare CMM++ specification, several feasibility studies are currently under way in different areas, namely - backplane data transfer rates tests, latency survey, optical link and FPGA technologies studies, study of transferring current firmware to new hardware 4.1 Backplane data transfer The CMM receives over the backplane from the CPM/JEM modules up to 400 signal lines on each 40 MHz clock cycle The CMM++ interface to CPM/JEM shall be able to run in the backward compatible (CMM) version first and then shall be upgraded to 160 Mb/s data transfer and a new data format The deployment of the CMM++ module requires firmware modifications in the CPM and JEM in order to collect the RoI information, generated in the modules, and to send it to the CMM++ over the crate backplane –5– Figure The BLT module The Backplane and Link Tester module (BLT) [4] was built to qualify the backplane transmission lines for increased data rates between CPM/JEM and CMM++ modules (Figure 5) As a result of the backplane transmission test, stable data transmission of 160Mb/s was achieved with source termination of the data lines and the forwarded clock line sink terminated Therefore, for each 40 MHz clock cycle 96 bits of data (24x4) can be transferred from each CPM/JEM module to CMM++ module The 25th signal line on the backplane will be used to forward the encoded clock/parity onto the CMM++ 4.2 Latency survey The maximum ATLAS L1 trigger latency was defined as 2500 ns (100 bunch crossings, BCs) from colliding beams to L1Accept arrival to detector front-end electronics The new topology algorithms require additional latency to process the data and it was decided to measure the actual latencies of different parts and paths of the L1Calo system Figure L1Calo latency The total L1Calo latency was measured in the counting room in the installed complete L1Calo system (Figure 6) The detailed breakdown was performed in the test setup, which allows access to individual modules/cables These measurements provided an insight into the used latencies in different parts of the L1Calo system and possible reserve for the upgrade –6– 4.3 Optical links study In order to investigate a possibility to exploit inexpensive 30 Gbit/s link using commercial components (Xilinx Spartan-3 FPGA, 10Gb Ethernet transceiver TLK3114SC, SNAP12 Tx/Rx pair) a prototype was build (Figure 7) Figure 30 Gbit/s optical link prototype It is driven by the LHC TTC clock, jitter reduced with LMK03033CISQ clock conditioner To run links synchronously with LHC clock alignment characters in some LHC bunch gaps are sent for link maintenance 4.4 Technology study The CMM++ module will be based on new components (modern FPGAs, high-speed optical links) In order to acquire experience with the new technologies, the GOLD (Generic Optical Link Demonstrator) is under design (Figure 8) Figure GOLD It’s main features include new, state-of-art FPGAs (Xilinx XC6VLXxxxT and Xilinx XC6VHX380T), optical links (6.4-10 Gbit/s) with SNAP12 and Avago optolinks, optical backplane connectors, new ATCA backplane form factor 4.5 Firmware study The CMM++ development scenario assumes that the module can be initially a drop-in replacement for the CMMs This implies the adaptation of the current CMM firmware to the –7– new hardware in order to provide full backward compatibility and testing with the current system Figure 30 Gbit/s optical link prototype A first attempt (Figure 9) was made to port Jet CMM firmware to target a Virtex device The aim was to use existing VHDL with minimal changes, to update architecture-specific features, to estimate I/O requirements and to produce a realistic user constraint file for timing simulation Results so far demonstrate that existing VHDL ports easily, uses ~2% of available resources and by emulating Glink in FPGA, can keep I/O count below 600/640 pins Conclusion Simulations performed show that rates for electrons and jets (especially of larger size) will be hard-put to fit in the current the L1 trigger bandwidth budget even near the design luminosity Trigger algorithms may need to be augmented to reduce rates and improve selectivity even before the current L1Calo trigger system is replaced A promising solution is to add topological algorithms based on relationships among triggered objects and thereby reduce the L1 rate This modest modification to the current system will have low impact on other ATLAS components The R&D projects and studies are well under way: backplane data transfer rates, technology demonstrator, firmware studies and others Preliminary results of these studies look promising and proposed modifications will improve the performance of the current ATLAS L1Calo trigger system References [1] ATLAS TDAQ Collaboration, The ATLAS Trigger/DAQ Authorlist, version 4.0, ATL-DAQ-PUB2010-002, CERN, Geneva, 2010, http://cdsweb.cern.ch/record/1265604 –8– [2] R Achenbach et al., The ATLAS Level-1 Calorimeter Trigger, 2008_JINST_3_P03001 (ATL-DAQ-PUB-2008-001), http://www.iop.org/EJ/article/17480221/3/03/P03001/jinst8_03_p03001.pdf [3] I.P Brawn, C.N.P Gee, Specification of the Common Merger Module, v1.8, 18 July 2008 (ATLDA-ES-0021), http://hepwww.rl.ac.uk/Atlas-L1/Modules/CMM/CMM_V1_8.pdf [4] B Bauss, U Schäfer, C Schröder, Backplane Tester Module, v0.3, 11 December 2008, http://www.staff.unimainz.de/baussh/Backplanetester/Sheets_Vers1.0.pdf –9– ... ET Both the CP and the JEP count ‘hit’ multiplicities of the different types of trigger objects, and send them, together with tower energy information (total and x,y components), to the two Common... and proposed modifications will improve the performance of the current ATLAS L1Calo trigger system References [1] ATLAS TDAQ Collaboration, The ATLAS Trigger/ DAQ Authorlist, version 4.0, ATL-DAQ-PUB2010-002,... 4.5Firmware study Conclusion Summary The ATLAS Level-1 Calorimeter Trigger (L1Calo) [2] is a fixed latency hardware-based pipelined system The real-time data path includes the pre-processor that conditions

Ngày đăng: 18/10/2022, 00:57

w