Microsoft Word A5¸ YÑX�¿ ô�f ñ⁄ Mia�Max 2022 1 6 SIRAY Max SIRAY Mia Dental X ray Unit Operating Manual Zhuhai Siger Medical Equipment Co , Ltd Foreword Please read this manual carefully before usin.
SIRAY Max / SIRAY Mia Dental X-ray Unit Operating Manual Zhuhai Siger Medical Equipment Co., Ltd Foreword Please read this manual carefully before using this product, and keep it handy for future use You must strictly follow the operating procedures to use this product and maintain it properly Paragraphs marked with "Warning" or "Caution" shall be read and executed carefully to avoid injuries to operators and patients or damage to the device If any fault occurs to the device during use, please contact the local dealer or the company in time Contents Chapter Product Description 1.1 Model and specifications: 1.2 Structure: 1.3 Intended use: 1.4 Technical parameters 1.4.1 Nameplate 1.4.2 Device technical parameters 1.4.3 Technical parameters of fixed anode X-ray tube 1.4.4 Technical parameters of X-ray tube assembly 1.4.5 Shell assembly of beam limiting device 1.4.6 Technical parameters of X-ray source module 1.5 Contraindications 1.6 Precautions, warnings and tips Chapter Device Operation Instructions 2.1 Description of the SIRAY Max operating panel and operation keys 2.1.1 Illustration of the operating panel 2.1.2 Description of buttons and symbols 10 2.2 SIRAY Max parameter settings and using method .11 2.2.1 Turn on the device 11 2.2.2 Operation settings 12 2.2.3 System settings 12 2.3 Description of SIRAY Mia operating panel and operation keys 17 2.3.1 Illustration of the operating panel 17 2.3.2 Description of buttons and symbols 18 2.4 SIRAY Mia parameter settings and using method 19 2.4.1 Turn on the device 19 2.4.2 Operation settings 20 2.4.3 Other system settings 21 2.5 Security protection function 22 2.6 Precautions 22 2.7 Place the dental film 23 2.8 Exposure values 24 2.9 Embedded software 25 Chapter Installation, Commissioning and Maintenance of the Dental X-ray Unit 25 3.1 Installation conditions 25 3.2 Device installation method 26 3.2.1 Installation of dental X-ray unit 26 3.3 Electrical schematic diagram 26 3.4 Maintenance of the device 27 3.5 The normal operations, transportation and storage conditions for the dental X-ray unit 28 3.6 Waste disposal 28 Chapter Common Troubleshooting and Other Matters 29 4.1 Common fault analysis and maintenance 29 4.2 The service life of device: 29 4.3 Graphics and symbols used for the device 30 Chapter Electromagnetic Compatibility 31 Chapter Product Description 1.1 Model and specifications: SIRAY Max, SIRAY Mia 1.2 Structure: It is mainly composed of host (X-ray tube head and control box), beam limiting device, power adapter and frame And it is divided into SIRAY Max dental X-ray unit (touch panel) and SIRAY Mia dental X-ray unit (button panel) according to its operating method The following is the panoramic view of the device: Dental X-ray unit SIRAY Max Dental X-ray unit SIRAY Mia 1.3 Intended use: This equipment is used for X-ray photography of teeth to obtain images for clinical diagnosis 1.4 Technical parameters 1.4.1 Nameplate Nameplate of complete machine, X-ray source module and beam limiting device 1.4.2 Device technical parameters Device Technical Parameters Table: Type I or Tube voltage (deviation Safety class internal within ±10%) power type Tube current (deviation within Protection type Type B ±10%) IntermittentDevice loading Load cycle operating mode continuous operation Disinfection See 3.4 Total filtration method Common Protection level Inherent filtration equipment AC Power adapter Additional filtration 100-240 V Power frequency 50/60 Hz Half-value layer Input power 110 VA Leakage radiation Charging voltage DC 24 V Loading time adjustment range (deviation within the range of ± (10%+1 ms)) Distance between the focus and the skin (deviation ±5%) Actual dimension A of the X-ray at the end of the beam limiting device (54 mm≤A≤60 mm) Charging current 1.67A Ray focus 0.4 mm Anode angle 12.5゜ Nominal electric power The maximum tube voltage available is 2mA 70 kV The maximum tube current available is 70kV 70 kV mA 1/30 ≥2 mm Al(70 kV) ≥ mm Al(70 kV) mm Al(70 kV) 70 kV ≥1.5 mm Al m <0.25 mGy/h 0.020~2.000s, the grading number is selected according to R’10 number system 200mm Φ6 0mm 0.14 kW(70 kV,2 mA, 0.1 s) 2mA Maximum 140 W(70 High voltage generator output electric 20 kHz kV,2 mA) frequency power Maximum Permanently installed or 70 kV, Nonpermanently loading factor nonpermanently installed mA, s installed equipment combination equipment This product is the common Whether the device has signal SIRAY Max and SIRAY Mia None output or input device The product has no application for protection against defibrillation discharge effect Remarks: for other parameters, refer to the X-ray tube, X-ray tube assembly and X-ray source module parameters for details 1.4.3 Technical parameters of fixed anode X-ray tube Model D-045 Manufacturer Focal spot 0.4 mm Target material Tungsten Maximum tube voltage 70 kV Anode angle Inherent filtration Maximum filament current Canon Electron Tube Equipment Co Ltd 12.5゜ At least equivalent to 1.0 mm Al 3.0 A Filament DC or AC (sine wave) 0~20 frequency limit kHz Remarks: for other parameters, please refer to the official parameters of X-ray tube Dimensional Outline Unit: mm 1.4.4 Technical parameters of X-ray tube assembly See 3.3 for electric connection See 3.1 for the precautions to be followed and the special procedures for adjusting the X-ray tube at the end of X-ray tube assembly installation and before the initial loading Safety class Type I or internal power type Weight 1.8 kg Protection Type Loading factors combination in leakage radiation test 70 kV, mA, s Type B Focal spot 0.4 mm Transportation and storage Environmenta l temperature -20℃~+55℃ Atmospheric pressure 50 kPa~106 kPa Relative humidity ≤93% Remarks: for other parameters, refer to the X-ray tube parameters for details Dimensional Outline of X-ray Tube Assembly, unit: mm CENTRAL X-RAY DIRECTION FOCAL SPOT 1.4.5 Shell assembly of beam limiting device M57x1.5 BEAM LIMITING DEVICE 1.4.6 Technical parameters of X-ray source module Focal spot Source module assembly tolerance 0.4 mm ±1.5 mm Remarks: for other parameters, refer to the X-ray tube and X-ray tube assembly parameters Dimensional Outline of X-ray Source Module, unit: mm CENTRAL X-RAY DIRECTION FOCAL SPOT in selected state 2.4.3 Other system settings Long press the mode selection button for 5s, and it will enter the program mode settings state after you hear three beeps of the buzzer The digital window will display P1 You can select program P1/P2/P3 via or key The definitions of each program are: P1 indicates the cumulative exposure times, P2 indicates the standby time and P3 indicates the system reset, which are circulated in order After the program mode settings, long press the mode selection button for 5s, it will exit the program mode settings state after you hear three beeps of the buzzer (or after 20 s without operation) 2.4.3.1 Cumulative exposure times In system settings state, when the exposure times P1 is selected, press the mode selection button to check the cumulative exposure times (digital display window), and press the mode selection button again to return 2.4.3.2 Standby time In system settings state, when the standby time P2 is selected, press the mode selection button to select the standby time as 300/600/900/1200/1500/1800 s (digital display window) via or button, and press the mode selection button again to return 2.4.3.3 System reset 21 In system settings state, when the system reset P3 is selected, press the mode selection button to enter the system reset Factory settings will not clear the cumulative exposure times of the runtime counter 2.5 Security protection function After the exposure is finished, the dental X-ray unit is in the natural cooling protection state and the time window is displayed as the countdown At this time, press the controller exposure button, the dental X-ray unit will not work After the cooling is completed and the device restores to the last set working state, the device can a new task During an exposure, in the event of an emergency, the exposure can stop when the Exposure button is released When the error code occurs: H1 indicates that the exposure button fails to bounce up, H2 indicates exposure interrupted before the time expires, and H3 indicates high temperature detected on the tube head 2.6 Precautions Radiation protection: (1) When the photosensitizer dose is sufficient, the distance from the focus to the skin shall be increased as much as possible so that on the one hand, X-ray radiation on the patient can be reduced and on the other hand, image distortion can be reduced (2) During the loading process, the operator shall operate meters away from the tube head and shall not stand in the X-ray radiation direction The operator must use a protective device and wear protective clothing If the local health sector has stipulated that it is necessary that an engine room and relevant protective facilities shall be provided, it shall be carried out according to the provisions of the local health department; (3) In the event of an unexpected emergency, e.g., when the power switch is turned on or the Exposure button is pressed, the exposure indicator is lit constantly or the buzzer keeps buzzing, the power switch shall be turned off immediately to prevent radiation or machine damage (4) Test method of radiation dose when the equipment is working: when it is running (70 kV, mA, 2.000 s, 20 times) under nominal voltage of X-ray tube with the maximum input energy equivalent to the specified 1h, at 1m from the focal spot, and the average air Kerma rate does not exceed 0.25 mGy/h within any area of 100 cm² (the main linear size is not longer than 200 mm) 22 (5) If the operator operates the equipment outside the clinic room, it is recommended to install radiation-proof visible window or video equipment and audio equipment, so that the operator can see the patient and communicate with him/her Safety and use: Attention: Dental X-ray film shall be purchased and used by professional physicians at their own discretion The dental X-ray film used shall meet the requirements of national standards with the record certificate of Class I medical equipment 2.7 Place the dental film According to the photographed tooth position of the patient, place the dental film in the corresponding position in mouth while ask the patient to press it with his/her index finger Adjust the beam limiting device of the tube head until its end surface is about 10 mm from the skin and its axis (i.e., the X-ray) is perpendicular to the bisector of the angle between the long axis of the tooth and the film, as shown in the following figure: Tube head Angle bisector X-ray Dental film Tooth See the following table for details of the average X-ray tilt angles for projecting the maxillary and mandibular teeth according to the desired angles of the teeth: Number X-ray Direction Incisor 1,2 Downward +42° Unicuspid tooth Downward +45° 4,5,6 Downward +30° 7,8 Downward +28° 1,2 Upward -15° Tooth Position Maxillary Mandibular Bicuspid tooth and the first molar The second and third molars Incisor 23 Tilt X-ray Tube Tilt Angle Unicuspid tooth Bicuspid tooth and the first molar The second and third molars Upward -18~20° 4,5,6 Upward -10° 7,8 Upward -5° The numbers and layout of all teeth: Maxillary 1 Mandibular 1 2.8 Exposure values The first time you turn on the dental x-ray unit, the default exposure values are displayed The grading number of the loading time is selected according to the number system of R’10 These values can also be customized according to actual use The recommended exposure values are shown in the table below: Exposure Time Table Teeth Position/ Mode Maxillary Molar Maxillary Canine Maxillary Anterior Mandibula r Molar Mandibula r Canine Mandibula r Anterior Large size PSP Small size Digital Film-s Film-s Film-sp Digital Film-s Film-s Film-sp PSP program peed F peed E eed D program peed F peed E eed D 0.63 0.50 0.80 1.00 1.25 0.40 0.32 0.50 0.63 0.80 0.50 0.40 0.63 0.80 1.00 0.25 0.20 0.32 0.40 0.50 0.50 0.40 0.63 0.80 1.00 0.25 0.20 0.32 0.40 0.50 0.63 0.50 0.80 1.00 1.25 0.40 0.32 0.50 0.63 0.80 0.40 0.32 0.50 0.63 0.80 0.25 0.20 0.32 0.40 0.50 0.32 0.25 0.40 0.50 0.63 0.20 0.16 0.25 0.32 0.40 Attention: The exposure times in the table are recommended ones, which can be set by the user as they like with time and experience The operating techniques and exposure times are provided according to general conditions, the patient size is classified according to an adult patient weighing 45 kg, the distance between the sensor and the generator focus is 24 approximate to 220mm, the exposure time varies according to the patient size and the angle of use of the X-ray, and the dose is increased in proportion to the square of the distance 2.9 Embedded software Release version of the embedded software: V1.01 Chapter Installation, Commissioning and Maintenance of the Dental X-ray Unit 3.1 Installation conditions Caution: The installation of this device must be completed by the company's professional personnel or personnel trained and authorized by the company Caution: After the first installation: Turn on the power to check whether all the indications and prompts of the operating panel are normal Adjust the loading factor to the minimum (70kV, mA, 0.02 s) for exposure Check whether all the indications and prompts of the operating panel are normal and whether the exposure of the device is normal You can use the device when all of its functions are normal This device shall be placed in a clean, dry, ventilated and shaded place Retain enough space around the device for routine maintenance Do not install and use the device in the following places: (1) Humid, dusty or poorly ventilated places or places in direct sunlight; (2) Places where changes in high temperatures or high humidity often occur, e.g., places near air conditioners and heaters; Caution: Improper installation may damage the device! Determine the installation location according to the overall layout of the clinic room, lighting, use convenience and other specific circumstances The machine shall be placed in a clean, dry, ventilated and cool place to keep it in a good operating environment The device shall be transported to the desired installation site according to the method specified on the outer packaging box Remove the outer package of the device, take out the packing list and check the configuration and accessories to see if they are intact If you have any doubts, 25 please contact the company in time 3.2 Device installation method 3.2.1 Installation of dental X-ray unit Dimensions of the X-ray room: 1.8 meters in length, 1.5 meters in width and meters in height The power supply is 100-240 V with a ground wire and the wire diameter is no less than mm2 Power supply voltage: single phase AC100-240 V; power supply frequency: 50/60Hz 3.2.1.1 Installation of support Unfold the support and mount it on a firm and flat surface, and then mount the host on the support 3.2.1.2 Installation of external exposure button (outside) If the exposure button is installed outside, add an external exposure button and install it in a proper position 3.2.1.3 Connection of power adapter Insert the input plug of the power adapter into the AC 100-240V power socket, and insert the output plug of the power adapter into the DC power socket of the dental X-ray unit to charge the equipment At the same time, the charging icon on the screen will flash, and the icon will stop flashing when it is fully charged Attention: The device must be disconnected from the charging source of the power adapter during working and exposure; otherwise it cannot work normally When the charging icon on the device screen displays battery low, please charge the device in time 3.3 Electrical schematic diagram Any operation involving maintenance of the equipment interior must be performed by a qualified engineer who shall determine the damaged parts according to the Fault Code Table when repairing the equipment, and replace the parts provided by the company You can contact the after-sales department of our company for technical guidance During maintenance, you can contact our company to obtain the electric schematic diagram and other relevant data 26 3.4 Maintenance of the device Caution: The correct maintenance method can extend the life of the device! The host shall not vibrate and bump violently while being used; The device's external components (e.g., the port of the beam limiting device) that often contact with doctors, nurses or patients must be wiped with alcohol once every day Caution: When cleaning the surface of the dental X-ray unit, disconnect the main power Caution: Do not use abrasives or acidic products Caution: The user should carry out the following inspections monthly: - Visually check whether all visible labels are in good condition; - Check whether the battery is sufficient and visually check whether the power adapter cable is damaged If the battery level is too low, charge the device in time with the matched power adapter If the power adapter is damaged, it should be replaced only by the authorized maintenance technician - When the efficiency of the battery is tremendously reduced and cannot meet daily use requirements, it should be replaced for a qualified one by the technician Please not replace the battery by yourself The built-in battery can only be replaced by a qualified technician - Visually check whether the exposure indicator is lit during the 27 exposure or the exposure interface is displayed during the exposure; - Verify that the buzzer emits sound during the exposure; - Check whether the exposure button must be pressed continuously within the exposure period; - When the exposure button is release prematurely, check whether the exposure is terminated; - Check all the functions of the operating panel 3.5 The normal operations, transportation and storage conditions for the dental X-ray unit Normal Operations Transportation and Storage Ambient temperature +10℃~+40℃ Ambient temperature -20℃~+55℃ Relative humidity 30%~75% Relative humidity ≤93% Atmospheric pressure 70 kPa~106 kPa Atmospheric pressure 50 kPa~106 kPa 3.6 Waste disposal If the service life of the equipment is too long, and the equipment cannot comply with the expected operation specifications of the manufacturer even after appropriate maintenance and repair, it cannot be used any longer and should be scrapped in time All provisions concerning waste disposal shall be observed At a minimum, the X-ray source modules and the electronic circuit related components of the equipment shall be regarded as non-environmental protection waste 28 Chapter Common Troubleshooting and Other Matters 4.1 Common fault analysis and maintenance Error messages are divided into two categories One category is Use Error (H) and the other System Error (E) Use errors can be quickly processed Display Content Error Cause Solution E1 The tube voltage signal line is not connected E2 The tube voltage signal line is shorted E3 The tube current signal line is not connected E4 The tube current signal line is shorted E5 The temperature signal line is not connected E6 The temperature signal line is shorted E7 Low tube voltage E8 Low tube current Please contact the supplier for solution Please contact the supplier for solution Please contact the supplier for solution Please contact the supplier for solution Please contact the supplier for solution Please contact the maintenance department for assistance Please contact the maintenance department for assistance Please contact the maintenance department for assistance Please contact the maintenance department for assistance E9 H1 The filament drive signal line is not connected The Exposure button fails to bounce up Check the button H2 Exposure is interrupted Re-exposure H3 High temperature of the tube head is detected Wait until the tube head is cool 4.2 The service life of device: This device has an expected service life of eight years See the nameplate for the production date 29 4.3 Graphics and symbols used for the device It appears alone if other contents are shown in the user manual When appearing together with “Caution”, it means important information for users or service personnel When appearing together with “Warning”, it means that failure to follow the Manual may cause personal injury or damage to the device and its components “Fragile” sign “No wet” sign Storage humidity limit sign "Up" sign Storage atmospheric pressure limit sign Storage temperature limit sign X-ray filter plate Stacking limit It is the sign meaning “Do not discard an electronic device freely” According to the regulations, after the expiration date, the device shall be disposed of according to the local legal requirements to avoid polluting the environment and injuring the user Means “See the accompanying document” Class: Class B of Type I “Grounding” sign Power switch button X-ray source device: transmitter Radiation warning sign Dangerous voltage 30 Chapter Electromagnetic Compatibility Caution: The dental X-ray unit meets the relevant electromagnetic compatibility requirements of the standard YY0505 and GB9706 The user shall install and use the device according to the electromagnetic compatibility information provided in the accompanying document Portable and mobile RF communication devices may influence the performance of the dental X-ray unit When using the device, avoid strong electromagnetic interference, e.g., in the vicinity of mobile phones, microwave ovens, etc See Annex for details of the guidelines and the manufacturers’ statements Warning: The dental X-ray unit shall not be placed near or stacked with other equipment when it is used Otherwise, you shall observe and verify whether it runs properly with the operating settings thereof Use of the cables other than the cables that are delivered by the dental X-ray unit manufacturer as spare parts for internal components may result in an increase in the emission of the dental X-ray unit or a reduction in its immunity Cable information Name Power cord of the adapter Cable length (m) 1.5 Whether it is shielded No Annex: Guidelines and the manufacturer's statement − electromagnetic emission The dental X-ray unit is intended for use the electromagnetic environment specified below The customer or the user of dental X-ray unit should assure that it is used in such an environment: Emissions test Complia nce RF emission GB 4824 Group RF emission GB 4824 Class B Harmonic emissions GB 17625.1 Class A Voltage fluctuation/flicker emissions GB 17625.2 Complia nt Electromagnetic environment - guideline The dental X-ray unit uses RF energy only for its internal function Therefore, its RF emission is very low and not likely to cause any interference in nearby electronic equipment The dental X-ray unit is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes 31 Guidelines and the manufacturer's declaration − electromagnetic immunity The dental X-ray unit image intensifier is intended for use in the electromagnetic environment specified below The customer or the user of the dental X-ray unit image intensifier should assure that it is used in such an environment Immunity test IEC 60601 Test level Compliance Level Electrostatic discharge (ESD) GB/T 17626.2 ±6 kV Contact discharge ±8 kV Air discharge ±6 kV Contact discharge ±8 kV Air discharge Floors should be wood, concrete or ceramic tile If the floors are covered with synthetic material, the relative humidity should be at least 30% Electrical fast transient/burst GB/T 17626.4 ±2 kV To power cord ±1 kV To input/output line ±2 kV To power cord Mains power quality should be that of a typical commercial or hospital environment Electrical surge GB/T 17626.5 ±1 kV Line to line ±2 kV Line to ground ±1 kV Line to line ±2 kV Line to ground Mains power quality should be that of a typical commercial or hospital environment Voltage dips, short interruptions and voltage variations on power supply input lines GB/T 17626.11 95% dip) 40%UT, last for cycles (on UT, 60% dip) 70%UT, last for 25 cycles (on UT, 30% dip) 95% dip) 95% dip) 40%UT, last for cycles (on UT, 60% dip) 70%UT, last for 25 cycles (on UT, 30% dip) 95% dip) Mains power quality should be that of a typical commercial or hospital environment If the user of the dental X-ray unit requires continuous operation during power mains interruptions, it is recommended that the dental X-ray unit be powered from an uninterruptible power supply or a battery A/m,50/60 Hz The power frequency magnetic field shall have the characteristics of the power frequency magnetic field level that of a typical commercial or hospital environment Power frequency (50/60Hz) magnetic field GB/T 17626.8 A/m Electromagnetic environment - guidance Note: UT is the a.c mains voltage prior to application of the test level Guidance and manufacturer's declaration − electromagnetic immunity The dental X-ray unit is intended for use in the electromagnetic environment specified below The customer or the user of the dental X-ray unit should assure that it is used in such an electromagnetic environment: 32 Immunity test RF conduction GB/T 17626.6 RF radiation GB/T 17626.3 IEC 60601 Test level Vrms 150 kHz~80 MHz Complia nce Level Vrms V/m V/m 80 MHz~2.5 GHz Electromagnetic environment − guidance Portable and mobile RF communications equipment should be used no closer to any part of the dental X-ray unit, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance: d = 1.2 P d = 1.2 P P 80 MHz to 800 MHz d = 2.3 800 MHz to 2.5 GHz Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m) Field strengths from fixed RF transmitter, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol: Note 1: At 80 MHz and 800 MHz, the higher frequency range applies Note 2: These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures, objects and people a Field strengths fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitter, an electromagnetic site survey should be considered If the measured field strength in the location in which the dental X-ray unit is used exceeds the applicable RF compliance level above, the dental X-ray unit should be observed to verify normal operation If abnormal performance is observed, additional measures may be necessary, such as re-adjust or relocate the dental X-ray unit b Over the frequency range from 150 kHz to 80 MHz, field strengths should be less than V/m 33 Recommended separation distances between portable and mobile RF communications equipment and the dental X-ray unit The dental X-ray unit is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user can prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communication equipment (transmitters) and the dental X-ray unit as recommend below, according to the maximum output power rating of the communications equipment Separation distance according to frequency of transmitter/m Rated maximum output power of transmitter W 150 kHz ~ 80 MHz 0.01 0.12 0.12 0.23 0.1 0.38 0.38 0.73 1.2 1.2 2.3 10 3.8 3.8 7.3 100 12 12 23 d= 80 MHz ~ 800 MHz P d= P 800 MHz ~ 2.5 GHz d= 2.3 P For transmitter rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimate using the equation applicable to the frequency of transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer Note 1: At 80 MHz and 800 MHz, the higher frequency range applies Note 2: These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures, objects and people 34 Registrant/Manufacturer: Zhuhai Siger Medical Equipment Co., Ltd After-sales service provider: Zhuhai Siger Medical Equipment Co., Ltd Residence: Building 2, No Chuangxin Yi Road, Tangjiawan Town, Zhuhai City, Guangdong, China Production Address: Building 2, No Chuangxin Yi Road, Tangjiawan Town, Zhuhai City, Guangdong, China Tel: +86–0756–3881018 Fax: +86–0756–3881028 Customer service hotline: 0756–3881650 Website: http://www.siger.cn E-mail: info@siger.cn Version :A0 ... X-ray unit (touch panel) and SIRAY Mia dental X-ray unit (button panel) according to its operating method The following is the panoramic view of the device: Dental X-ray unit SIRAY Max Dental. .. this manual The notes contain the information on all optional components of the dental x-ray units SIRAY Max and SIRAY Mia, so some of the information may not apply to your machine This manual. .. specifications: SIRAY Max, SIRAY Mia 1.2 Structure: It is mainly composed of host (X-ray tube head and control box), beam limiting device, power adapter and frame And it is divided into SIRAY Max dental