Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống
1
/ 57 trang
THÔNG TIN TÀI LIỆU
Nội dung
Document Content Addition of Document Subject: ESD ESD Periodic Measurement Standards Alteration of Document Revocation of Document Doc No: 702-N0026 REV: 16 PAGE OF 57 Revision History Rev Status Revision Date Description Revised By 2011/01/10 2011/04/13 2011/04/28 Qiang Li Initial Issue / Qiang Li/ Jack GH Lee ADD PAGE Added page Static Pile 6.2.3 Modified verification frequency of grounding wrist straps 6.2 Modified compliance verification frequency of anti-static floors 6.2.6 Modified compliance verification frequency of Ion discharging effectiveness Page5 6.2.1.3 -> NQJ /NQX: ( ) ( ) Page 5, 6.2.1.3 test procedure item 3: Added NQJ /NQX: static grounding cable (green), equipment grounding cable (chartreuse) Page 6.2.2.3 11 < 1.0 x 10^9 Jack GH Lee Page 7, 6.2.2.3 test procedure: added item 11 In addition to point-to-ground test, point-to-point tests must comply with < 1.0 × 109 Page 13 6.2.5 / 6.2.5.1 Page 13 Modified ESD Jacket/anti-static chair cover verifications of 6.2.5 and modified 6.2.5.1 Purpose Page 16 11 WTQ & 12 NQJ /NQX Page 16 Modified item 11: WTQ dissipation specifications and item 12 NQJ /NQX dissipation specifications Page 18 6.2.8 / / ( ) 6.2.8.1 Page 18 Modified 6.2.8, the compliance verification of moving equipment (cart)/shelf/static conveyor and modified “6.2.8.1 Purpose” The Information contained herein is the exclusive property of WNC and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of WNC Form No.: 2-JQ-021-04, 006