Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

120 3 0
Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Split-type room air conditioner Installation Manual RSVH09VS-I RSVH09VS-O RSVH12VS-I RSVH12VS-O EN VN CONTENTS Safety instructions 2 Accessories Installation summary - indoor unit 11 Unit parts 13 Indoor unit installation 14 5.1 Installation instructions – indoor 14 Outdoor unit installation 28 6.1 Installation instructions – outdoor unit 28 Refrigerant piping connection 7.1 7.2 7.3 7.4 37 Note on pipe length 37 Connection instructions – refrigerant piping 37 Instructions for connecting piping to indoor unit 41 Instructions for connecting piping to outdoor unit .42 Air evacuation 44 8.1 Preparations and precautions 44 8.2 Evacuation instructions 44 Electrical and gas leak checks 48 9.1 Electrical safety checks .48 9.2 Gas leak checks 49 10 Test run 50 10.1 Before test run 50 10.2 Test run instructions 50 11 European disposal guidelines 52 12 Installation instructions 53 12.1 F-Gas instruction 53 13 Information servicing Split-type room air conditioner / Installation Manual 54 / 60 EN Safety instructions Read safety precautions before installation Incorrect installation due to ignoring instructions can cause serious damage or injury The seriousness of potential damage or injuries is classified as Warning Warning ••Do not modify the length of the power supply cord or use an extension cord to power the unit Do not share the electrical outlet with other appliances Improper or insufficient power supply can cause fire or electrical shock ••When connecting refrigerant piping, not let substances or gases other than the specified refrigerant enter the unit The presence of other gases or substances will lower the unit’s capacity, and can cause abnormally high pressure in the refrigeration cycle This can cause explosion and injury ••Do not allow children to play with the air conditioner Children must be supervised around the unit at all times ••Installation must be performed by an authorized dealer or specialist Defective installation can cause water leakage, electrical shock, or fire ••Installation must be performed according to the installation instructions Improper installation can cause water leakage, electrical shock, or fire (In North America,installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only.) / 60 EN Split-type room air conditioner / Installation Manual Safety instructions ••Contact an authorized service technician for repair or maintenance of this unit ••Only use the included accessories, parts, and specified parts for installation Using non-standard parts can cause water leakage, electrical shock, fire, and can cause the unit to fail ••Install the unit in a firm location that can support the unit’s weight If the chosen location cannot support the unit’s weight, or the installation is not done properly, the unit may drop and cause serious injury and damage ••For all electrical work, follow all local and national wiring standards, regulations, and the Installation Manual You must use an independent circuit and single outlet to supply power Do not connect other appliances to the same outlet Insufficient electrical capacity or defects in electrical work can cause electrical shock or fire ••For all electrical work, use the specified cables Connect cables tightly, and clamp them securely to prevent external forces from damaging the terminal Improper electrical connections can overheat and cause fire, and may also cause shock ••All wiring must be properly arranged to ensure that the control board cover can close properly If the control board cover is not closed properly, it can lead to corrosion and cause the connection points on the terminal to heat up, catch fire, or cause electrical shock ••In certain functional environments, such as kitchens, server rooms, etc., the use of specially designed air-conditioning units is highly recommended ••If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard Split-type room air conditioner / Installation Manual / 60 EN Safety instructions ••This appliance can be used by children aged from years and above and persons with reduced Physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater) Do not pierce or burn Appliance shall be stored in a well -ventilated area where the room size corresponds to the room area as specifiec for operation Be aware that refrigerants may not contain an odour C Note Clause to are required for the units adopt R32/R290 Refrigerant Warning ••For units that have an auxiliary electric heater, not install the unit within meter (3 feet) of any combustible materials ••Do not install the unit in a location that may be exposed to combustible gas leaks If combustible gas accumulates around the unit, it may cause fire ••Do not operate your air conditioner in a wet room such as a bathroom or laundry room Too much exposure to water can cause electrical components to short circuit / 60 EN Split-type room air conditioner / Installation Manual Safety instructions ••The product must be properly grounded at the time of installation, or electrical shock may occur ••Install drainage piping according to the instructions in this manual Improper drainage may cause water damage to your home and property C Note about fluorinated gasses This air-conditioning unit contains fluorinated gasses For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself Installation, service, maintenance and repair of this unit must be performed by a certified technician Product uninstallation and recycling must be performed by a certified technician If the system has a leak-detection system installed, it must be checked for leaks at least every 12 months When the unit is checked for leaks, proper recordkeeping of all checks is strongly recommended Split-type room air conditioner / Installation Manual / 60 EN Accessories The air conditioning system comes with the following accessories Use all of the installation parts and accessories to install the air conditioner Improper installation may result in water leakage, electrical shock and fire, or cause the equipment to fail Name Shape Quantity Mounting plate Clip anchor Mounting plate fixing screw ST3.9 X 25 Remote controller Fixing screw for remote controller holder ST2.9 x 10 Optional Parts Remote controller holder Dry battery AAA.LR03 / 60 EN Split-type room air conditioner / Installation Manual Accessories Name Shape Quantity Seal (for cooling & heating models only) Drain joint Split-type room air conditioner User Manual User manual EN Installation manual Air conditioner Remote control illustration Remote controller illustration EN Liquid side Connect ing pipe assembly Ø6.35 (1/4in) Ø9.52 (3/8in) Ø9.52 (3/8in) Gas side Ø12.7 (1/2in) Parts you must purchase Consult the dealer about the pipe size Ø16 (5/8in) Split-type room air conditioner / Installation Manual / 60 EN Accessories A Warning: Appliance shall be stored in a well -ventilated area where the room size corresponds to the room area as specifiec for operation For R32 frigerant models: Appliance shall be installed, operated and stored in a room with a floor area larger than 4m2 Appliance shall not be installed in an unvertilated space, if that space is smaller than 4m2 For R290 refrigerant models, the minimum room size needed: 9000Btu/h and 12000Btu/h and 18000Btu/h and

Ngày đăng: 08/04/2022, 12:47

Hình ảnh liên quan

Tên Hình minh họa Số lượng - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

n.

Hình minh họa Số lượng Xem tại trang 69 của tài liệu.
11. Bảng mặt trước - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

11..

Bảng mặt trước Xem tại trang 73 của tài liệu.
Hình 5.1 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 5.1.

Xem tại trang 75 của tài liệu.
Hình 5.2 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 5.2.

Xem tại trang 76 của tài liệu.
Hình 5.3 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 5.3.

Xem tại trang 79 của tài liệu.
Đảm bảo sắp đặt ống xả nước theo Hình 5.5. • KHÔNG làm vẹo ống. - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

m.

bảo sắp đặt ống xả nước theo Hình 5.5. • KHÔNG làm vẹo ống Xem tại trang 80 của tài liệu.
Hình 5.5 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 5.5.

Xem tại trang 81 của tài liệu.
Bảng mạch (PCB) của máy điều hòa được thiết kế với một cầu chì để bảo vệ quá dòng. Thông số kỹ thuật của cầu chì được in trên bảng mạch, chẳng hạn như:  T3.15A/250VAC TSA/250VAC… - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Bảng m.

ạch (PCB) của máy điều hòa được thiết kế với một cầu chì để bảo vệ quá dòng. Thông số kỹ thuật của cầu chì được in trên bảng mạch, chẳng hạn như: T3.15A/250VAC TSA/250VAC… Xem tại trang 83 của tài liệu.
4. Tháo vít kẹp cáp bên dưới bảng đấu dây và đặt vít qua một bên. 5. Chuyển qua mặt sau của dàn lạnh, tháo tấm nhựa ở góc dưới bên trái - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

4..

Tháo vít kẹp cáp bên dưới bảng đấu dây và đặt vít qua một bên. 5. Chuyển qua mặt sau của dàn lạnh, tháo tấm nhựa ở góc dưới bên trái Xem tại trang 84 của tài liệu.
1. Bó ống xả nước, ống dẫn gas lạnh, và cáp tín hiệu như hình 5.10. Dàn lạnh trong nhà - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

1..

Bó ống xả nước, ống dẫn gas lạnh, và cáp tín hiệu như hình 5.10. Dàn lạnh trong nhà Xem tại trang 85 của tài liệu.
Hình 5.11 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 5.11.

Xem tại trang 86 của tài liệu.
Hình 5.12 Đẩy sang trái hoặc phải30-50mm - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 5.12.

Đẩy sang trái hoặc phải30-50mm Xem tại trang 87 của tài liệu.
Hình 6.1 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 6.1.

Xem tại trang 89 của tài liệu.
Nếu khớp nối xả có kèm theo một vòng đệm cao su (xem Hình 6.4-A), thực hiện như sau: 1 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

u.

khớp nối xả có kèm theo một vòng đệm cao su (xem Hình 6.4-A), thực hiện như sau: 1 Xem tại trang 90 của tài liệu.
Nếu khớp nối xả không có vòng đệm cao su (xem Hình 6.4-B), thực hiện như sau: 1. Lắp khớp nối xả vào lỗ dưới đáy quạt của dàn nóng - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

u.

khớp nối xả không có vòng đệm cao su (xem Hình 6.4-B), thực hiện như sau: 1. Lắp khớp nối xả vào lỗ dưới đáy quạt của dàn nóng Xem tại trang 91 của tài liệu.
Hình 6.5 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 6.5.

Xem tại trang 92 của tài liệu.
3.Tháo vít kẹp cáp bên dưới bảng đấu dây và đặt vít bên cạnh. - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

3..

Tháo vít kẹp cáp bên dưới bảng đấu dây và đặt vít bên cạnh Xem tại trang 95 của tài liệu.
Hình 6.6Nắp che - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 6.6.

Nắp che Xem tại trang 96 của tài liệu.
Xem bảng bên dưới để biết quy cách về chiều dài và độ cao rơi tối đa của ống. - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

em.

bảng bên dưới để biết quy cách về chiều dài và độ cao rơi tối đa của ống Xem tại trang 97 của tài liệu.
Hình 7.2 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 7.2.

Xem tại trang 98 của tài liệu.
Hình 7.3 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 7.3.

Xem tại trang 99 của tài liệu.
Hình 7.4Ống đồng - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 7.4.

Ống đồng Xem tại trang 99 của tài liệu.
Hình 7.6 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 7.6.

Xem tại trang 100 của tài liệu.
Hình 7.5 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 7.5.

Xem tại trang 100 của tài liệu.
1. Tháo nắp đậy bộ van trên mặt hông của dàn nóng ngoài trời. (Xem Hình 7.9). - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

1..

Tháo nắp đậy bộ van trên mặt hông của dàn nóng ngoài trời. (Xem Hình 7.9) Xem tại trang 102 của tài liệu.
Hình 7.10 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 7.10.

Xem tại trang 103 của tài liệu.
Hình 8.1 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 8.1.

Xem tại trang 105 của tài liệu.
Hình 8.2 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 8.2.

Xem tại trang 106 của tài liệu.
Hình 10.1 - Huong-Dan-Lap-Dat-(Tieng-Viet-Trang-61)

Hình 10.1.

Xem tại trang 111 của tài liệu.

Mục lục

  • 安装说明书 (1).pdf

    • 安装说明书

      • Ò³Ãæ 1

      • 安装说明书

        • Ò³Ãæ 1

        • 安装说明书

          • Ò³Ãæ 1

          • 安装说明书

            • Ò³Ãæ 1

            • 安装说明书

              • Ò³Ãæ 1

              • 20190724 Installation Manual RSVH_VN

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan