Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống
1
/ 20 trang
THÔNG TIN TÀI LIỆU
Thông tin cơ bản
Định dạng
Số trang
20
Dung lượng
398,59 KB
Nội dung
5.3 Moving to other groups l There are different parameter groups in SV- iG5A series as shown below Drive group FU group FU group I/O group Drive group Basic parameters necessary for the inverter to run Parameters such as Target frequency, Accel/Decel time settable Basic function parameters to adjust output frequency and voltage Advanced function parameters to set parameters for such as PID Operation and second motor operation Parameters necessary to make up a sequence using Multifunction input/output terminal Function group Function group I/O (Input/Output) group l Moving to other parameter groups is only available in the first code of each group as the figure shown below Moving to other groups using the Right (u) key Moving to other groups using the Left (t) key * * Drive group Drive group Function group I/O group Function group I/O group Function group Function group st * Target frequency can be set at 0.0 (the code of drive group) Even though the preset value is 0.0, it is user-settable The changed frequency will be displayed after it is changed 5-3 l How to move to other groups at the 1st code of each group - The 1st code in Drive group “0.00” will be displayed when AC input power is applied - Press the right arrow (u) key once to go to Function group - The 1st code in Function group “F 0” will be displayed - Press the right arrow (u) key once to go to Function group - The 1st code in Function group “H 0” will be displayed - Press the right arrow (u) key once to go to I/O group - The 1st code in I/O group “I 0” will be displayed - Press the right arrow (u) key once again to return to Drive group - Return to the 1st code in Drive group “0.00” ♣ If the left arrow key (t) is used, the above will be executed in the reverse order l How to move to other groups from any codes other than the 1st code Pressing left or right arrow key in any code will return to first code of each group Drive group FU group FU group To move from the F 15 to function group - In F 15, press the Left (t) or Right arrow (u) key Pressing the key goes to the first code of the group - The 1st code in function group “F 0” is displayed - Press the right arrow (u) key - The 1st code in function group “H 0” will be displayed 5-4 5.4 How to change the codes in a group l Code change in Drive group - In the 1st code in Drive group “0.00”, press the Up (p) key once - The 2nd code in Drive group “ACC” is displayed - Press the Up (p) key once - The 3rd code “dEC” in Drive group is displayed - Keep pressing the Up (p) key until the last code appears Drive group - The last code in Drive group “drC” is displayed - Press the Up (p) key again - Return to the first code of Drive group ♣ Use Down (q) key for the opposite order l Code jump When moving from the “F 0” to the “F 15” directly - Press the Ent (˜) key in “F 0” - (the code number of F1) is displayed Use the Up (p) key to set to - “05” is displayed by pressing the Left (t) key once to move the cursor to the left The numeral having a cursor is displayed brighter In this case, is active - Use the Up (p) key to set to - 15 is set - Press the Ent (˜) key once FU group - Moving to F 15 has been complete ♣ Function group and I/O group are settable with the same setting 5-5 l Navigating codes in a group When moving from F to F 15 in Function group 1 - In F 1, continue pressing the Up (p) key until F15 is displayed - Moving to F15 has been complete ♣ The same applies to Function group and I/O group ♣Note: Some codes will be skipped in the middle of increment (p)/decrement (q) for code change That is because it is programmed that some codes are intentionally left blank for future use or the codes user does not use are invisible For example, when F24 [High/low frequency limit select] is set to “O (No) ”, F25 [High frequency limit] and F26 [Low frequency limit] are not displayed during code change But When F24 is set to “1(Yes)”, F25 and F26 will appear on the display 5-6 5.5 Parameter setting l Changing parameter values in Drive Group When changing ACC time from 5.0 sec to 16.0 sec Drive group - In the first code “0.00”, press the Up (p) key once to go to the second code - ACC [Accel time] is displayed - Press the Ent key (˜) once - Preset value is 5.0, and the cursor is in the digit - Press the Left (t) key once to move the cursor to the left - The digit in 5.0 is active Then press the Up (p) key once - The value is increased to 6.0 - Press the Left (t) key to move the cursor to the left - 0.60 is displayed The first in 0.60 is active - Press the Up (p) key once - 16.0 is set - Press the Ent (˜) key once - 16.0 is blinking - Press the Ent (˜) key once again to return to the parameter name - ACC is displayed Accel time is changed from 5.0 to 16.0 sec ♣ In step 7, pressing the Left (t) or Right (u) key while 16.0 is blinking will disable the setting Note 1) Pressing the Left (t)/ Right (u) /Up (p) /Down (q) key while cursor is blinking will cancel the parameter value change Pressing the Enter key (˜) in this status will enter the value into memory 5-7 l Frequency setting When changing run frequency to 30.05 Hz in Drive group Drive group - In “0.00”, press the Ent (˜) key once - The second decimal becomes active - Press the UP (p) key until is displayed - Press the Left (t) key once - The first decimal becomes active - Press the Left (t) key once - Press the Left (t) key once - Set using UP (p) key - Press the Ent (˜) key - 30.05 is blinking - Press the Ent (˜) key - 30.05 is entered into memory ♣ SV-iG5A display can be extended to digits using left (t)/right (u) keys ♣ Parameter setting is disabled when pressing other than Enter Key in step 5-8 l Changing parameter value in Input/Output group When changing the parameter value of F28 from to FU group 1 - In F0, press the Ent (˜) key once - Check the present code number - Increase the value to by pressing the Up (p) key - When is set, press the Left (t) key once - in 08 is active - Increase the value to by pressing the Up (p) key - 28 is displayed - Press the Ent (˜) key once - The parameter number F28 is displayed - Press the Ent (˜) key once to check the set value - The preset value is displayed - Increase the value to using UP key (p) - Press the Ent (˜) key - Code number will appear after is blinking Parameter change is complete - Press either Left (t) or Right (u) keys 10 - Moving to first code of Function group is complete ♣ The above setting is also applied to change parameter values in function group and I/O group 5-9 5.6 Monitoring of operation status l Output current display Monitoring output current in Drive group Drive group - In [0.0], continue pressing the Up (p) or Down (q) key until [CUr] is displayed - Monitoring output current is provided in this parameter - Press the Enter (˜) key once to check the current - Present output current is A - Press the Enter (˜) key once to return to the parameter name - Return to the output current monitoring code ♣ Other parameters in Drive group such as dCL (Inverter DC link current) or vOL (Inverter output voltage) can be monitored via the same method 5-10 l Fault display How to monitor fault condition in Drive group During Accel Overcurrent trip Current Frequency STOP RESET Drive group - This message appears when an Overcurrent fault occurs - Press the Enter (˜) key or UP/Down key once - The run frequency at the time of fault (30.0) is displayed - Press the Up (p) key once - The output current at the time of fault is displayed - Press the Up (p) key once - Operating status is displayed A fault occurred during acceleration - Press the STOP/RST key once - A fault condition is cleared and “nOn” is displayed When more than one fault occurs at the same time - Maximum three faults information is displayed as shown left Motor overheat Over voltage Over current Drive group 5-11 l Parameter initialize How to initialize parameters of all four groups in H93 FU group - In H0, press the Enter (˜) key once - Code number of H0 is displayed - Increase the value to by pressing the Up (p) key - In 3, press the Left (t) key once to move the cursor to the left - 03 is displayed in 03 is active - Increase the value to by pressing the Up (p) key - 93 is set - Press the Enter (˜) key once - The parameter number is displayed - Press the Enter (˜) key once - Present setting is - Press the Up (p) key once to set to to activate parameter initialize - Press the Enter (˜) key once - Return to the parameter number after blinking Parameter initialize has been complete - Press the either Left (t) or Right (u) key 10 - Return to H0 5-12 CHAPTER - BASIC OPERATION 6.1 Frequency Setting and Basic Operation ☞ Caution : The following instructions are given based on the fact that all parameters are set to factory defaults Results could be different if parameter values are changed In this case, initialize parameter values (see page 10-21) back to factory defaults and follow the instructions below l Frequency Setting via keypad & operating via terminals - Apply AC input power to the inverter - When 0.00 appears, press the Ent (˜) key once - The second digit in 0.00 is lit as shown left - Press the Left (t) key three times - 00.00 is displayed and the first is lit - Press the Up (p) key - 10.00 is set Press the Ent (˜) key once - 10.00 is blinking Press the Ent (˜) key once - Run frequency is set to 10.00 Hz when the blinking stops - Turn on the switch between P1 (FX) and CM terminals - RUN lamp begins to blink with FWD (Forward Run) lit and accelerating frequency is displayed on the LED - When target run frequency 10Hz is reached, 10.00 is displayed - Turn off the switch between P1 (FX) and CM terminals - RUN lamp begins to blink and decelerating frequency is displayed on the LED - When run frequency is reached to 0Hz, Run and FWD lamp turn off and 10.00 is displayed 3P AC Input R U V W S T Motor 10 Hz Freq G P1(FX) CM P1(FX)-CM Wiring ON Operating pattern 6-1 OFF l Frequency Setting via potentiometer & operating via terminals - Apply AC input power to the inverter - When 0.00 appears Press the Up (p) key four times - Frq is displayed Frequency setting mode is selectable - Press the Ent (˜) key once - Present setting method is set to (frequency setting via keypad) - Press the Up (p) key three times - After (Frequency setting via potentiometer) is set, press the Ent (˜) key once - Frq is redisplayed after stops blinking - Turn the potentiometer to set to 10.00 Hz in either Max or Min direction - Turn on the switch between P1 (FX) and CM (See Wiring below) - RUN lamp begins to blink with FWD lamp lit and the accelerating frequency is displayed on the LED - When run frequency 10Hz is reached, the value is displayed as shown left - Turn off the switch between P1 (FX) and CM terminals - RUN lamp begins to blink and decelerating frequency is displayed on the LED - When run frequency is reached to 0Hz, Run and FWD lamp turn off and 10.00 is displayed 3P AC input R S T U V W Motor 10 Hz Freq P1(FX) G P1(FX)-CM CM ON VR V1 CM Wiring Operating pattern 6-2 OFF l Frequency setting via potentiometer & operating via the Run key - Apply AC input power to the inverter - When 0.00 is displayed, press the Up (p) key three times - “drv” is displayed Operating method is selectable - Press the Ent (˜) key - Check the present operating method (“1”: Run via control terminal) - Press the Ent (˜) key and then Down (q) key once - After setting “0”, press the Ent (˜) key When is blinking, press the Ent again - “drv” is displayed after “0” is blinking Operation method is set via the Run key on the keypad - Press the Up (p) key once - Different frequency setting method is selectable - Press the Ent (˜) key - Check the present frequency setting method (“0” is run via keypad) - Press the Up (p) key three times - After checking “3” (frequency setting via potentiometer), press the Ent (˜) key 10 - “Frq” is displayed after “3” is blinking Frequency setting is set via the potentiometer on the keypad - Turn the potentiometer to set to 10.0 Hz in either Max or Min direction 11 - Press the Run key on the keypad - RUN lamp begins to blink with FWD lamp lit and accelerating frequency is displayed on the LED - When run frequency 10Hz is reached, 10.00 is displayed as shown left - Press the STOP/RST key 12 - RUN lamp begins to blink and decelerating frequency is displayed on the LED - When run frequency is reached to 0Hz, Run and FWD lamp turn off and 10.00 is displayed R S T U V W Motor 10 Hz Freq Keypad Run key G VR STOP/RST key V1 CM Wiring Operating pattern 6-3 Notes: 6-4 CHAPTER - FUNCTION LIST l Drive Group LED display Parameter name 0.00 [Frequency command] ACC [Accel time] dEC [Decel time] drv [Drive mode] Frq St1 St2 St3 CUr [Frequency setting method] Min/Max range Description ~ 400 [Hz] Adj during run Factory defaults Page This parameter sets the frequency that the inverter is commanded to output During Stop: Frequency Command During Run: Output Frequency During Multi-step operation: Multi-step frequency It cannot be set greater than F21[Max frequency] ~ 6000 During Multi-Accel/Decel operation, [Sec] this parameter serves as Accel/Decel time 0~3 Run/Stop via Run/Stop key on the keypad FX: Motor forward run RX: Motor reverse Terminal run operation FX: Run/Stop enable RX: Reverse rotation select RS485 communication 0.00 O 9-1 5.0 O 9-12 10.0 O 9-12 X 9-8 0~7 [Multi-Step ~ 400 frequency 1] [Hz] [Multi-Step frequency 2] [Multi-Step frequency 3] [Output current] Digital Keypad setting Keypad setting V1 1: -10 ~ +10 [V] V1 2: ~ +10 [V] Terminal I: ~ 20 [mA] Analog Terminal V1 setting + Terminal I Terminal V1 setting 2+ Terminal I RS485 Sets Multi-Step frequency during Multi-step operation Sets Multi-Step frequency during Multi-step operation Sets Multi-Step frequency during Multi-step operation Displays the output current to the motor 7-1 9-8 9-9 X 9-1 9-1 9-2 9-4 9-4 9-5 9-6 10.00 O 9-6 9-7 20.00 O 9-7 30.00 O 9-7 - - 11-1 l Drive Group LED display rPM dCL vOL Parameter name Min/Max range [Motor RPM] [Inverter DC link voltage] [User display select] Adj during run Factory defaults Page Displays the number of Motor RPM nOn [Fault Display] drC [Direction of motor rotation select] F, r drv21 [Drive mode 2] 0~2 Frq2 [Frequency setting method 2] 0~6 Description - - 11-1 Displays DC link voltage inside the inverter This parameter displays the item selected at H73- [Monitoring item select] vOL Output voltage POr Output power tOr Torque Displays the types of faults, frequency and operating status at the time of the fault Sets the direction of motor rotation when drv - [Drive mode] is set to either or F Forward r Reverse Run/Stop via Run/Stop key on the keypad Terminal FX: Motor forward operation run RX: Motor reverse run FX: Run/Stop enable RX: Reverse rotation select Keypad setting Digital Keypad setting 2 V1 1: -10 ~ +10 [V] Analog V1 2: ~ +10 [V] Terminal I: ~ 20 [mA] Terminal V1 setting + Terminal I Terminal V1 setting 2+ Terminal I - - 11-1 vOL - 11-2 - - 11-4 F O 9-8 X 10-19 X 10-19 Only displayed when one of the Multi-function input terminals 1-8 [I17~I24] is set to “22” 7-2 l Function group LED display Parameter name Min/Max range F0 [Jump code] ~ 60 F1 [Forward/ Reverse run disable] 0~2 F2 [Accel pattern] [Decel pattern] [Stop mode select] 0~1 [DC Brake start frequency] 0.1 ~ 60 [Hz] F9 [DC Brake wait time] ~ 60 [sec] F10 [DC Brake voltage] ~ 200 [%] F11 [DC Brake time] ~ 60 [sec] F12 [DC Brake start voltage] ~ 200 [%] F13 [DC Brake start time] ~ 60 [sec] F14 [Time for magnetizing a motor] ~ 60 [sec] F20 [Jog frequency] ~ 400 [Hz] F3 F4 F8 1) Description Sets the parameter code number to jump Fwd and rev run enable Forward run disable Reverse run disable Linear 0~2 Adj during run Factory defaults Page O 5-5 X 9-10 X 9-15 X 9-20 5.00 X 10-1 0.1 X 10-1 50 X 10-1 1.0 X 10-1 50 X 10-2 X 10-2 1.0 X 10-11 10.00 O 10-3 S-curve Decelerate to stop DC brake to stop Free run to stop This parameter sets DC brake start frequency It cannot be set below F23 - [Start frequency] When DC brake frequency is reached, the inverter holds the output for the setting time before starting DC brake This parameter sets the amount of DC voltage applied to a motor It is set in percent of H33 – [Motor rated current] This parameter sets the time taken to apply DC current to a motor while motor is at a stop This parameter sets the amount of DC voltage before a motor starts to run It is set in percent of H33 – [Motor rated current] DC voltage is applied to the motor for DC Brake start time before motor accelerates This parameter applies the current to a motor for the set time before motor accelerates during Sensorless vector control This parameter sets the frequency for Jog operation It cannot be set above F21 – [Max frequency] 1) : Only displayed when F is set to (DC brake to stop) 7-3 l Function group LED display F211) Parameter name [Max frequency] Min/Max range 40 ~ 400 [Hz] F22 [Base frequency] 30 ~ 400 [Hz] F23 [Start frequency] ~ 10 [Hz] F24 [Frequency high/low limit select] [Frequency high limit] 0~1 F25 2) F26 F27 F28 F29 Description This parameter sets the highest frequency the inverter can output It is frequency reference for Accel/Decel (See H70) 60.00 Caution: Any frequency cannot be set above Max frequency except Base frequency The inverter outputs its rated 60.00 voltage to the motor at this frequency (see motor nameplate) The inverter starts to output its 0.50 voltage at this frequency It is the frequency low limit This parameter sets high and low limit of run frequency ~ 400 [Hz] This parameter sets high limit of the run frequency It cannot be set above F21 – [Max frequency] 0.1 ~ 400 This parameter sets low limit of [Frequency low limit] [Hz] the run frequency It cannot be set above F25 [Frequency high limit] and below F23 – [Start frequency] [Torque 0~1 Manual torque boost Boost select] Auto torque boost [Torque boost ~ 15 This parameter sets the amount in forward [%] of torque boost applied to a motor direction] during forward run It is set in percent of Max output voltage [Torque boost This parameter sets the amount in reverse of torque boost applied to a motor direction] during reverse run It is set as a percent of Max output voltage 1) : Only displayed when F24 (Frequency high/low limit select) is set to 7-4 Page X 9-21 X 9-17 X 9-21 X 9-21 60.00 X 0.50 X X 9-19 X 9-19 X 9-19 : If H40 is set to (Sensorless vector), Max frequency is settable up to 300Hz 2) Adj during run Factory defaults l Function group LED display Parameter name Min/Max range F30 [V/F pattern] 0~2 F311) [User V/F frequency 1] [User V/F voltage 1] [User V/F frequency 2] [User V/F voltage 2] [User V/F frequency 3] [User V/F voltage 3] [User V/F frequency 4] [User V/F voltage 4] [Output voltage adjustment] ~ 400 [Hz] ~ 100 [%] ~ 400 [Hz] ~ 100 [%] ~ 400 [Hz] ~ 100 [%] ~ 400 [Hz] ~ 100 [%] 40 ~ 110 [%] [Energysaving level] [Electronic thermal select] ~ 30 [%] 0~1 F32 F33 F34 F35 F36 F37 F38 F39 F40 F50 Adj during run X 15.00 X 25 X 30.00 X 50 X 45.00 X 75 X 60.00 X 100 X This parameter adjusts the 100 amount of output voltage The set value is the percentage of input voltage This parameter decreases output voltage according to load status This parameter is activated when the motor is overheated (timeinverse) X 9-18 10-12 12-1 Description {Linear} {Square} {User V/F} It cannot be set above F21 – [Max frequency] The value of voltage is set in percent of H70 – [Motor rated voltage] The values of the lowernumbered parameters cannot be set above those of highernumbered 1) : Set F30 to 2(User V/F) to display this parameter 7-5 Factory defaults Page 9-17 9-17 9-18 9-18 l Function group LED display F51 1) Parameter name Min/Max range [Electronic thermal level for minute] 50 ~ 200 [%] F52 [Electronic thermal level for continuous] F53 [Motor cooling method] F54 [Overload 30 ~ 150 warning level] [%] F55 [Overload warning time] ~ 30 [Sec] F56 [Overload trip select] 0~1 F57 [Overload trip level] 30 ~ 200 [%] F58 [Overload trip time] ~ 60 [Sec] 0~1 Description This parameter sets max current capable of flowing to the motor continuously for minute The set value is the percentage of H33 – [Motor rated current] It cannot be set below F52 – [Electronic thermal level for continuous] This parameter sets the amount of current to keep the motor running continuously It cannot be set higher than F51 – [Electronic thermal level for minute] Standard motor having cooling fan directly connected to the shaft A motor using a separate motor to power a cooling fan This parameter sets the amount of current to issue an alarm signal at a relay or multi-function output terminal (see I54, I55) The set value is the percentage of H33- [Motor rated current] This parameter issues an alarm signal when the current greater than F54- [Overload warning level] flows to the motor for F55[Overload warning time] This parameter turns off the inverter output when motor is overloaded This parameter sets the amount of overload current The value is the percentage of H33- [Motor rated current] This parameter turns off the inverter output when the F57[Overload trip level] of current flows to the motor for F58[Overload trip time] 1) : Set F50 to to display this parameter 7-6 Adj during run Factory defaults 150 100 150 10 180 60 12-1 0 Page 12-2 12-3 ... Run and FWD lamp turn off and 10.00 is displayed 3P AC Input R U V W S T Motor 10 Hz Freq G P1( FX) CM P1( FX)-CM Wiring ON Operating pattern 6-1 OFF l Frequency Setting via potentiometer & operating... 0Hz, Run and FWD lamp turn off and 10.00 is displayed 3P AC input R S T U V W Motor 10 Hz Freq P1( FX) G P1( FX)-CM CM ON VR V1 CM Wiring Operating pattern 6-2 OFF l Frequency setting via potentiometer... key once - Run frequency is set to 10.00 Hz when the blinking stops - Turn on the switch between P1 (FX) and CM terminals - RUN lamp begins to blink with FWD (Forward Run) lit and accelerating