Tài liệu Datasheet - FO - Cable - Non-Armor - MM - Technical Spec PE Jacket pdf
... 0.20 dB (MM) No jacket cracking and fiber breakage Temperature Cycling Test # Test method: TIA/EIA-45 5-3 A Temperature cycling schedule : 23 -3 065 -3 06523 Soak time at each temperature: ... this section shall be performed at 1550nm for single mode fiber (SM) and at 1300nm for multi mode fiber (MM) . Table 5. The Mechanical and Environmental Performance of the Cable...
Ngày tải lên: 24/01/2014, 02:20
... TECHNICAL SPECIFICATION Central Tube, Single Jacket /non-Armor Cable [10Gigabit Ethernet MMF ] 1. SCOPE 1.1 Application This specification covers ... Stripes ** 12 Aqua 24 Aqua / Double Ring Stripes ** 5. PHYSICAL / MECHANICAL / ENVIRONMENTAL PERFORMANCE AND TESTS 5.1 Temperature Range For the cables covered by this sp...
Ngày tải lên: 20/12/2013, 21:16
... TECHNICAL SPECIFICATION Central Tube Single Jacket /non-Armor Cable 50/125um, 10Gigabit Ethernet MMF P/N N006CTSLZH050U 1. SCOPE 1.1 Application This specification ... TIA/EIA-FOTP-82 Length of specimen: 3m Height of pressure head: 1m Test time: 24 hours # Acceptance Criteria No leakage through the open cable end Flammability Test (LSZH Jac...
Ngày tải lên: 20/12/2013, 21:16
Tài liệu Datasheet - FO - Cable - Highlight loose_tube_SM&MM docx
... HIGHLIGHT ® Outdoor Loose Tube Multimode & Singlemode Fibre Cable
Ngày tải lên: 16/01/2014, 20:21
Datasheet - FO - Cable - Non-Armor - MM - Technical Spec PE Jacket
... 0.20 dB (MM) No jacket cracking and fiber breakage Temperature Cycling Test # Test method: TIA/EIA-45 5-3 A Temperature cycling schedule : 23 -3 065 -3 06523 Soak time at each temperature: ... this section shall be performed at 1550nm for single mode fiber (SM) and at 1300nm for multi mode fiber (MM) . Table 5. The Mechanical and Environmental Performance of the Cable...
Ngày tải lên: 16/10/2013, 20:15
Tài liệu Datasheet - FO - Cable - In & Outdoor Loose Tube - HIGHLIGH doc
... HIGHLIGHT ® Outdoor Loose Tube Multimode & Singlemode Fibre Cable
Ngày tải lên: 09/12/2013, 15:15
Tài liệu Datasheet - FO - Cable - ThinLITE Zipcord doc
... Twist Test: EIA-FOTP-85A — — — Operating Temperature: -2 0°C to +70°C -2 0°C to +70°C 0°C to +70°C Storage Temperature : -4 0°C to +70°C -4 0°C to +70°C -4 0°C to +70°C -4 0°C to +70°C (non-flexing) Installation ... Listed Type: OFNR (Riser): UL1666, IN Type Pass Pass Pass Cable Knot Test: EIA-FOTP-87B Pass Pass Pass Fiber Proof Test: 100 KPSI 100 KPSI 100 KPSI High/Low Te...
Ngày tải lên: 09/12/2013, 15:15
Tài liệu Datasheet - FO - Cable - ThinLITET Cables pptx
... Twist Test: EIA-FOTP-85A — — — Operating Temperature: -2 0°C to +70°C -2 0°C to +70°C 0°C to +70°C Storage Temperature : -4 0°C to +70°C -4 0°C to +70°C -4 0°C to +70°C -4 0°C to +70°C (non-flexing) Installation ... Listed Type: OFNR (Riser): UL1666, IN Type Pass Pass Pass Cable Knot Test: EIA-FOTP-87B Pass Pass Pass Fiber Proof Test: 100 KPSI 100 KPSI 100 KPSI High/Low Te...
Ngày tải lên: 10/12/2013, 02:15
Tài liệu Datasheet - FO - Cable - 10 Gbs Multi Mode Fiber docx
... 1.0 Guaranteed Min Bandwidth (MHz-km) Typical Attenuation (dB/km) Max Attenuation (dB/km) * Bandwidth specified by overfilled launch (OFL) ** Bandwidth specified by laser-based launch Specifications: * 10 ... 500* 1310nm/1550nm N / A Core 62.5 / 125 Multimode 62.5 / 125 Enhanced MM 50 / 125 Multimode 50 / 125 Enhanced MM 50 / 125 Ultra MM 62.5 / 125 Multimode Single- Mode 850nm/1300nm 3...
Ngày tải lên: 11/12/2013, 13:15
Tài liệu Datasheet - FO - Cable - Fibre Distribution Cables docx
... EIA-FOTP-37A — — — Passes @ 0°C and 70°C Passes @ 0°C and 70°C Cable Twist Test: EIA-FOTP-85A — — — 1000 Cycles 1000 Cycles Operating Temperature: -2 0°C to +70°C -2 0°C to +70°C 0°C to +70°C -2 0°C ... Resistance: EIA-FOTP-41A 400 N/cm 400 N/cm 400 N/cm 400 N/cm 400 N/cm Impact Resistance: EIA-FOTP-25B 50 Impacts 100 Impacts 50 Impacts 500 Impacts 500 Impacts Flexing: EIA-FOTP-104...
Ngày tải lên: 11/12/2013, 13:15