Tài liệu Datasheet - FO - Cable 10Gbit MM - N006CTSLZH050U doc
... Criteria The cable shall comply with IEC 33 2-1 . 6.2 Cable Re-marking The re-marking shall be indent-marked, preferably with yellow characters, on the outer cable sheath. Any cable that ... Jacket/non-Armor Cable 50/125um, 10Gigabit Ethernet MMF P/N N006CTSLZH050U 5. PHYSICAL / MECHANICAL / ENVIRONMENTAL PERFORMANCE AND TESTS 5.1 Temperature Rang...
Ngày tải lên: 20/12/2013, 21:16
... Environmental Performance of the Cable (continued) ITEMS TEST METHOD AND ACCEPTANCE CRITERIA Repeated Impact Test # Test method: TIA/EIA-FOTP-25 Height of impact: 15 0mm Drop hammer mass: 2.0kg ... TIA/EIA-FOTP-82 Length of specimen: 3m Height of pressure head: 1m Test time: 24 hours # Acceptance Criteria No leakage through the open cable end Flammability Test (LSZH J...
Ngày tải lên: 20/12/2013, 21:16
... Resistance: EIA-FOTP-41A 400 N/cm 400 N/cm 400 N/cm 400 N/cm 400 N/cm Impact Resistance: EIA-FOTP-25B 50 Impacts 100 Impacts 50 Impacts 500 Impacts 500 Impacts Flexing: EIA-FOTP-104A 1000 Cycles ... Passes @ 0°C and 70°C Cable Twist Test: EIA-FOTP-85A — — — 1000 Cycles 1000 Cycles Operating Temperature: -2 0°C to +70°C -2 0°C to +70°C 0°C to +70°C -2 0°C to +70°C (OFNR) -2 0°C t...
Ngày tải lên: 11/12/2013, 13:15
Tài liệu Datasheet - FO - Cable - Armor Direct Burried doc
... CHARACTERISTICS: Cable type: A-DF(ZN)2Y(SR)2Y Fibre count 2 - 30 32 - 48 50 - 96 Diameter approx. [ mm ] 14.3 16.5 18.0 Weight approx. [ kg/km ] 195 276 304 Min. bending radius - during installation - installed [ mm ] [ mm ] 315 285 365 330 400 360 Tensile ... and 1550nm. - Non-metallic central member. - Loose buffer tubes (dual layer design) SZ stranded....
Ngày tải lên: 16/01/2014, 20:21
Tài liệu Datasheet - FO - Cable - Highlight loose_tube_SM&MM docx
... HIGHLIGHT ® Outdoor Loose Tube Multimode & Singlemode Fibre Cable
Ngày tải lên: 16/01/2014, 20:21
Tài liệu Datasheet - FO - Cable - Non-Armor - MM - Technical Spec PE Jacket pdf
... this section shall be performed at 1550nm for single mode fiber (SM) and at 1300nm for multi mode fiber (MM) . Table 5. The Mechanical and Environmental Performance of the Cable ITEMS TEST METHOD ... Environmental Performance of the Cable (continued) ITEMS TEST METHOD AND ACCEPTANCE CRITERIA Repeated Impact Test # Test method: TIA/EIA-45 5-2 5B Height of impact: 15 0mm Drop hammer mas...
Ngày tải lên: 24/01/2014, 02:20
Tài liệu Datasheet - FO - Cable - In & Outdoor Loose Tube - HIGHLIGH doc
... HIGHLIGHT ® Outdoor Loose Tube Multimode & Singlemode Fibre Cable
Ngày tải lên: 09/12/2013, 15:15
Tài liệu Datasheet - FO - Cable - ThinLITE Zipcord doc
... Pass Pass Pass Cable Knot Test: EIA-FOTP-87B Pass Pass Pass Fiber Proof Test: 100 KPSI 100 KPSI 100 KPSI High/Low Temp. Bend Test: EIA-FOTP-37A — — — Cable Twist Test: EIA-FOTP-85A — — — Operating ... SOLUTIONS ThinLITE™ CABLES Mechanical & Environmental Characteristics Test Single Fiber Duplex Cable Zipcord Crush Resistance: EIA-FOTP-41A 400 N/cm 400 N/cm 400 N/cm Impact Resistance...
Ngày tải lên: 09/12/2013, 15:15
Tài liệu Datasheet - FO - Cable - ThinLITET Cables pptx
... Cable and Jacket Specifications and Ordering Information Cable Cable Cable No. of UL Diameter Weight Jacket Part Number Type Fibers Type (in) (mm) (Nom. lbs./km) Type ... 5050 E-mail: stewart.yao@krone.com.hk KRONE New Zealand Tel: +64 4 576 9213 Fax: +64 4 576 9243 E-mail: sales@krone.co.nz KRONE Vietnam Tel: +84 4 934 396 8- Ext:145, 146 Fax: +84 4 934 3956 E-mail: ... Corning LE...
Ngày tải lên: 10/12/2013, 02:15
Tài liệu Datasheet - FO - Cable - 10 Gbs Multi Mode Fiber docx
... Number NxxxLTSDUCyyy NxxxLTDDUCyyy NxxxLTDARMyyy 7xxxLZHIOCyyy 7xxxLZHIOByyy 7xxxLZHBKAyyy xxx ( 4-7 2) Fiber Distribution Cable, Riser (OFNR) xxx ( 4-7 2) Fiber Distribution Cable, Plenum (OFNP) xxx ( 4-2 4) Fiber 2. 4mm Breakout Cable, Riser (OFNR) xxx ( 4-2 4) Fiber 2. 4mm Breakout Cable, ... 7006LZHIOC50U xxx ( 2-7 2) Fiber Outside Plant Cable, Non-Armored, Single xxx (...
Ngày tải lên: 11/12/2013, 13:15