... CRITERIA Tensile Performance # Test method: IEC 79 4-1 -E1 -. Mandrel diameter: 30D (D = cable diameter) -. Tensile load: 2,700N for 1 hour # Acceptance Criteria -. Fiber strain: ≤ 0.33% -. Attenuation ... IEC 79 4-1 Method F5 -. Length of specimen: 3m -. Height of pressure head: 1m -. Test time: 24 hours # Acceptance Criteria -. No leakage through the open cabl...

Ngày tải lên: 26/10/2013, 18:15

8 272 0
Datasheet - FO - Cable - Outdoor, Loose Tube, PE Jacketed

Datasheet - FO - Cable - Outdoor, Loose Tube, PE Jacketed

... KPSI Operating Temperature: -4 0°C to +70°C -4 0°C to +70°C Storage Temperature (non-flexing): -4 0°C to +70°C -4 0°C to +70°C Installation Temperature: -2 0°C to +70°C -2 0°C to +70°C * 6- to 72-Fiber ... Resistance (EIA-FOTP-41A): 900 N/cm 900 N/cm Impact Resistance (EIA-FOTP-25B): 100 impacts 100 impacts Flexing (EIA-FOTP-104A): 1000 cycles 100 cycles Maximum Pulling L...

Ngày tải lên: 26/10/2013, 18:15

2 317 0
Datasheet - FO - Cable - Non-Armor - MM - Technical Spec PE Jacket

Datasheet - FO - Cable - Non-Armor - MM - Technical Spec PE Jacket

... breakage Temperature Cycling Test # Test method: TIA/EIA-45 5-3 A -. Temperature cycling schedule : 23 -3 065 -3 06523 -. Soak time at each temperature: 8hours # Acceptance Criteria -. Attenuation ... Water Penetration Test # Test method: TIA/EIA-45 5-8 2B -. Length of specimen: 3m -. Height of pressure head: 1m -. Test time: 24 hours # Acceptance Criteria...

Ngày tải lên: 16/10/2013, 20:15

7 398 0
Tài liệu Datasheet - FO - Cable - Non-Armor - MM - Technical Spec PE Jacket pdf

Tài liệu Datasheet - FO - Cable - Non-Armor - MM - Technical Spec PE Jacket pdf

... this section shall be performed at 1550nm for single mode fiber (SM) and at 1300nm for multi mode fiber (MM). Table 5. The Mechanical and Environmental Performance of the Cable ITEMS TEST METHOD ... cracking and fiber breakage Temperature Cycling Test # Test method: TIA/EIA-45 5-3 A Temperature cycling schedule : 23 -3 065 -3 06523 Soak time at each temperature: 8hours # A...

Ngày tải lên: 24/01/2014, 02:20

7 264 0
Datasheet - FO - Cable - Non-Armor FIGURE 8

Datasheet - FO - Cable - Non-Armor FIGURE 8

... ENVIRONMENTAL PERFORMANCE AND TESTS 5.1 Temperature Range For the cables covered by this specification, the following temperature ranges apply: -. Operation : -2 5 °C to +70°C -. Installation : -1 0 °C ... Specification LGST 200 4-2 01 FOR Optical Fiber Cable Loose Tube / Jelly Filled Core Single Jacket / Non-Armored [ Figure-8 Self-supporting Aerial Cable ] 1. SCOPE 1.1 App...

Ngày tải lên: 16/10/2013, 05:15

9 471 0
Datasheet - FO - Cable - Outdoor - Armored JF fibre cable

Datasheet - FO - Cable - Outdoor - Armored JF fibre cable

... KRSI-JF-510C-GSP Page 1 of 8 TECHNICAL SPECIFICATION LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLE KRSI-JF-510C-GSP Page 2 of 8 1. SCOPE 1.1 Application This specification ... (MM) -. No jacket cracking and fiber breakage Temperature Cycling Test # Test method: TIA/EIA-45 5-3 A -. Temperature cycling schedule : 23  -3 0  65  -3 0  23 ...

Ngày tải lên: 22/10/2013, 11:15

8 315 0
Datasheet - FO - Cable - Outdoor Fibre Cable, Dual Jacket

Datasheet - FO - Cable - Outdoor Fibre Cable, Dual Jacket

... CRITERIA Tensile Performance # Test method: IEC 79 4-1 -E1 -. Mandrel diameter: 30D (D = cable diameter) -. Tensile load: 2,700N for 1 hour # Acceptance Criteria -. Fiber strain: ≤ 0.33% -. Attenuation ... IEC 79 4-1 Method F5 -. Length of specimen: 3m -. Height of pressure head: 1m -. Test time: 24 hours # Acceptance Criteria -. No leakage through the open cabl...

Ngày tải lên: 22/10/2013, 11:15

8 298 0
Datasheet - FO - cable - Optic Outdoor Armor Cable LSZH STA 30Mar04

Datasheet - FO - cable - Optic Outdoor Armor Cable LSZH STA 30Mar04

... apply: -. Operation : -4 0°C to +70°C -. Installation : 0°C to +70°C -. Storage/Shipping : -4 0°C to +70°C 5.2 Mechanical and Environmental Performance of the Cable The mechanical and environmental performance ... breakage Temperature Cycling Test # Test method: TIA/EIA-45 5-3 A -. Temperature cycling schedule : 23 -2 565 -2 56523 -. Soak time at each tem...

Ngày tải lên: 18/10/2013, 13:15

8 330 0
Tài liệu Datasheet - FO - Cable - In & Outdoor - LSZH jacketed pptx

Tài liệu Datasheet - FO - Cable - In & Outdoor - LSZH jacketed pptx

... Environmental Characteristics 4-1 2 Fibers 1 8-2 4 Fibers Crush Resistance (EIA-FOTP-41A): 1500 N/cm 1500 N/cm Impact Resistance (EIA-FOTP-25A): 1000 impacts 1000 impacts Flexing (EIA-FOTP-104A): 1000 cycles ... +70°C -4 0°C to +70°C Storage Temperature (non-flexing): -4 0°C to +70°C -4 0°C to +70°C Installation Temperature: 0°C to +70°C 0°C to +70°C * 6- to 72-Fiber Optical...

Ngày tải lên: 16/01/2014, 20:21

2 354 0
Datasheet - FO - Cable - Single Jacket Armor

Datasheet - FO - Cable - Single Jacket Armor

... KRSI-JF-510C-GSP Page 1 of 8 TECHNICAL SPECIFICATION LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLE KRSI-JF-510C-GSP Page 2 of 8 1. SCOPE 1.1 Application This specification ... Kpsi  100  100 *Note) Superior performance available upon request. KRSI-JF-510C-GSP Page 3 of 8 Table 2. The Optical, Geometrical and Mechanical Performance of the Single Mode Fiber...