Cabling Standard - TIA 568 B 2 - Addendum 10 - Draft 2 0

Cabling Standard - TIA 568 B.1 - Addendum 7 - Final

Cabling Standard - TIA 568 B.1 - Addendum 7 - Final

... TIA < /b> STANDARD < /b> ANSI /TIA-< /b> 56 8- B. 1-7 < /b> - 20 06 Approved: January 13, 20 06 Commercial Building Telecommunications Cabling < /b> Standard < /b> Part 1 - < /b> General Requirements Addendum 7 – Guidelines ... Association Standards & Technology Department 25 00 Wilson Boulevard, Suite 300 Arlington, VA 22 201 USA +1( 703 ) 90 7-7 < /b> 700 Organizat...
Ngày tải lên : 22/10/2013, 11:15
  • 28
  • 583
  • 0
Cabling Standard - TIA 568 B.2 - Addendum 10 - Draft 2.0

Cabling Standard - TIA 568 B.2 - Addendum 10 - Draft 2.0

... (dB) 1 .00 0. 1 4 .00 0. 1 8 .00 0. 1 10. 00 0. 1 16 .00 0. 1 20 .00 0. 1 25 .00 0. 1 31 .25 0. 1 62. 50 0 .2 100 .00 0 .2 200 .00 0. 3 25 0. 00 0.3 300 .00 0. 3 400 .00 0. 4 500 .00 0. 4 11 12 6/ 30 / 20 05 PN- 3-4 < /b> 426 -AD 10, draft ... (dB) 1 .00 1.9 4 .00 3.5 8 .00 4.9 10. 00 5.5 16 .00 6.9 20 .00 7.7 25 .00 8.7 31 .25 9.7 62. 50 13.9 100 .00...
Ngày tải lên : 22/10/2013, 11:15
  • 87
  • 436
  • 0
Cabling Standard - TIA 568 B.2 - Addendum 10 - Draft 4.0

Cabling Standard - TIA 568 B.2 - Addendum 10 - Draft 4.0

... (dB) 1 .00 0. 02 4 .00 0. 04 8 .00 0. 06 10. 00 0. 06 16 .00 0. 08 20 .00 0. 09 25 .00 0 . 10 31 .25 0. 11 62. 50 0.11 100 .00 0. 16 20 0. 00 0 . 20 25 0. 00 0 .28 300 .00 0. 32 400 .00 0. 35 500 .00 0. 40 ... 1 .00 62. 0 4 .00 60. 5 8 .00 55.6 10. 00 54 .0 16 .00 50. 6 20 .00 49 .0 25 .00 47.3 31 .25 45.7 62. 50 40. 6 1...
Ngày tải lên : 26/10/2013, 19:15
  • 99
  • 534
  • 0
Cabling Standard - TIA 568 B - Commercial Building Telecommunications Cabling Standard

Cabling Standard - TIA 568 B - Commercial Building Telecommunications Cabling Standard

... 16 of 62 Category 5e Backbone Cable PSELFEXT @ 20 ° C ± 3° C Frequency (MHz) Category 5e (dB) 1 .0 60. 8 4 .0 48.8 8 .0 42. 7 10. 0 40. 8 16 .0 36.7 20 .0 34.8 25 .0 32. 8 31 .25 30. 9 62. 5 24 .9 100 20 .8 Propagation ... Backbone Cable PSNEXT Loss @ 20 °C ± 3° C ( 100 meters) Frequency Category 3 (dB) Category 5e (dB) .7 72 43 64 1 .0 41 62. 3 4 .0 32 53.3 8 .0 28...
Ngày tải lên : 18/10/2013, 13:15
  • 62
  • 555
  • 0
Cabling Standard - TIA 569 A - Commercial Building Standard for Telecom Pathway & Spaces

Cabling Standard - TIA 569 A - Commercial Building Standard for Telecom Pathway & Spaces

... 500 0 50, 000 22 95 90 500 00 500 000 36 60 x 4775 12 x 15.5 600 0 60, 000 24 00 96 600 00 600 000 36 60 x 5 600 12 x 18.5 800 0 80, 000 301 5 1 20 800 00 800 000 36 60 x 6 8 10 12 x 22 .5 10, 00 0 100 ,00 0 36 30 144 ... m 2 ft 2 mm in m 2 ft 2 mm ft 100 0 10, 00 0 9 90 39 100 00 100 00 0 36 60 x 19 30 12 x 6.5 20 00 20 ,00 0 106...
Ngày tải lên : 26/10/2013, 19:15
  • 58
  • 671
  • 0
Cabling Standard - TIA 569 A - Commercial Building Standard for Telecom Pathway & Spaces (FULL VE

Cabling Standard - TIA 569 A - Commercial Building Standard for Telecom Pathway & Spaces (FULL VE

... 500 0 50, 000 22 95 90 500 00 500 000 36 60 x 4775 12 x 15.5 600 0 60, 000 24 00 96 600 00 600 000 36 60 x 5 600 12 x 18.5 800 0 80, 000 301 5 1 20 800 00 800 000 36 60 x 6 8 10 12 x 22 .5 10, 00 0 100 ,00 0 36 30 144 ... m 2 ft 2 mm in m 2 ft 2 mm ft 100 0 10, 00 0 9 90 39 100 00 100 00 0 36 60 x 19 30 12 x 6.5 20 00 20 ,00 0 106...
Ngày tải lên : 04/11/2013, 11:15
  • 58
  • 622
  • 1
Tài liệu Cabling Standard - TIA 598 A - FO Cable Color Coding doc

Tài liệu Cabling Standard - TIA 598 A - FO Cable Color Coding doc

... may also be used, but is not mandatory for fibers that are identified by their position; eg: ribbon fiber. When a number of fibers (e.g., 6, 12, 18, 24 ) form a unit/bundle, and units/bundles ... White with Black Tracer 19 Red with Black Tracer 20 Black with Yellow Tracer 21 Yellow with Black Tracer 22 Violet with Black Tracer 23 Rose with Black Tracer 2...
Ngày tải lên : 09/12/2013, 15:15
  • 8
  • 848
  • 0
Tài liệu Cabling Standard - TIA 606 - Administration Standard for the Telecommunications Infrastructure of ppt

Tài liệu Cabling Standard - TIA 606 - Administration Standard for the Telecommunications Infrastructure of ppt

... First Level Backbone Gray ( 422 C) Second Level Backbone Blue (29 1C) Station Termination (req'd at TR and ER only) Brown (465C) Interbuilding Backbone Cables Yellow ( 101 C) Auxilliary ... eg: C -0 0 1 could be a cable designated as 00 1. But a piece of termination hardware may be identified as 4A -B1 2 which would be termination hardware in closet 4A, on colum...
Ngày tải lên : 10/12/2013, 02:15
  • 20
  • 509
  • 0
Tài liệu Cabling Standard - TIA 607 - Commercial Building Grounding and Bonding Requirements for Telecommu doc

Tài liệu Cabling Standard - TIA 607 - Commercial Building Grounding and Bonding Requirements for Telecommu doc

... shall: • bond the TMGB to the service equipment (power) ground • be, at a minimum, the same size as the TBB (see below) The Telecommunications Bonding Backbone (TBB) The TBB is a conductor: ... the TBB shall: • be designed with over all design of the telecommunications backbone cabling < /b> system in mind • permit multiple TBBs as required • minimize the lengths of the TBBs...
Ngày tải lên : 10/12/2013, 02:15
  • 7
  • 593
  • 2
Tài liệu Cabling Standard - TIA 758 - Customer Owned Outside Plant pptx

Tài liệu Cabling Standard - TIA 758 - Customer Owned Outside Plant pptx

... For EC TC-6 EB-35 For EC TC-8 DB- 60 For DB or EC TC-6 DB - 100 For DB or EC a DB- 1 20 For DB or EC TC-8 Rigid Non Metallic Schedule 40 For DB or EC TC -2 Rigid Non ... manufacturer's standard < /b> size 9 0- degree bend; (e.g., 6 10 mm [24 in] is standard < /b> for 1 02 mm [4 in] conduit). Back-to-back 9 0- degree Bend: any two (2) 9 0- d...
Ngày tải lên : 10/12/2013, 02:15
  • 35
  • 476
  • 0

Xem thêm