Datasheet - FO - Cable - Outdoor Fibre Cable, Dual Jacket
... CRITERIA Tensile Performance # Test method: IEC 79 4-1 -E1 -. Mandrel diameter: 30D (D = cable diameter) -. Tensile load: 2,700N for 1 hour # Acceptance Criteria -. Fiber strain: ≤ 0.33% -. Attenuation ... 23 TECHNICAL SPECIFICATION Cable Specification No.: KGST-200 2-0 14 OPTICAL FIBRE CABLE LOOSE TUBE / JELLY FILLED DOUBLE JACKET / SINGLE ARMORED (LTD ARM CABLE) 2...
Ngày tải lên: 22/10/2013, 11:15
... HIGHLIGHT ® CSM and GP Indoor Fibre Cable See Network Performance in a New Light
Ngày tải lên: 16/01/2014, 20:21
... Resistance (EIA-FOTP-41A): 900 N/cm 900 N/cm Impact Resistance (EIA-FOTP-25B): 100 impacts 100 impacts Flexing (EIA-FOTP-104A): 1000 cycles 100 cycles Maximum Pulling Load (EIA-FOTP-33A): 2700 Newtons/604 ... 20 x cable O.D.* 20 x cable O.D.* Unloaded: 10 x cable O.D* 10 x cable O.D.* Fiber Proof Test: 100 KPSI 100 KPSI Operating Temperature: -4 0°C to +70°C -4 0°C to +70°C Stor...
Ngày tải lên: 26/10/2013, 18:15
Datasheet - FO - Cable - Outdoor - Armored JF fibre cable
... KRSI-JF-510C-GSP Page 1 of 8 TECHNICAL SPECIFICATION LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLE KRSI-JF-510C-GSP Page 2 of 8 1. SCOPE 1.1 ... method: TIA/EIA-45 5-3 3A -. Mandrel diameter: 30D (D = cable diameter) -. Short term tensile load: 2,700N for 1 hour -. Long term tensile load: 1,000N for 10 minutes # Acceptance Criteria -. Fiber strain:...
Ngày tải lên: 22/10/2013, 11:15
Datasheet - FO - Cable - Outdoor, Armor, PE Jacketed
... requirements for fiber optic telecommunication cables used for inter-building backbone in duct, direct buried and lashed aerial installation. 1.2 Cable Description 1) Jelly Filled / Double Jacket ... section shall be performed at 1550nm for single mode fiber (SM) and at 1300nm for multi mode fiber (MM). Table 5. The Mechanical and Environmental Performance of the Cable ITEM...
Ngày tải lên: 26/10/2013, 18:15
Tài liệu Datasheet - FO - Cable - In & Outdoor - LSZH jacketed pptx
... Environmental Characteristics 4-1 2 Fibers 1 8-2 4 Fibers Crush Resistance (EIA-FOTP-41A): 1500 N/cm 1500 N/cm Impact Resistance (EIA-FOTP-25A): 1000 impacts 1000 impacts Flexing (EIA-FOTP-104A): 1000 cycles ... Attenuation and Bandwidth values for Single-mode: 1310nm/1550nm FIBER OPTIC SOLUTIONS Tight-Buffered, Low-Smoke, Zero-Halogen Jacketed Features: ■ Available in single-mode as wel...
Ngày tải lên: 16/01/2014, 20:21
Datasheet - FO - Cable - Non-Armor - MM - Technical Spec PE Jacket
... method: TIA/EIA-45 5-3 3A -. Mandrel diameter: 30D (D = cable diameter) -. Short term tensile load: 2,700N for 1 hour -. Long term tensile load: 1,000N for 10 minutes # Acceptance Criteria -. Fiber strain: ... method: TIA/EIA-45 5-8 5A -. Cable length twisted: 2m -. No. of twist cycles: 10 cycles -. Twist angle: 180 # Acceptance Criteria -. Attenuation Increm...
Ngày tải lên: 16/10/2013, 20:15
Datasheet - FO - cable - Optic Outdoor Armor Cable LSZH STA 30Mar04
... method: TIA/EIA-45 5-3 3A -. Mandrel diameter: 30D (D = cable diameter) -. Short term tensile load: 2,700N for 1 hour -. Long term tensile load: 1,000N for 10 minutes # Acceptance Criteria -. Fiber strain: ... method: TIA/EIA-45 5-8 5A -. Cable length twisted: 2m -. No. of twist cycles: 10 cycles -. Twist angle: ±180˚ # Acceptance Criteria -. Attenuation Increm...
Ngày tải lên: 18/10/2013, 13:15
Datasheet - FO - Cable - Single Jacket Armor
... KRSI-JF-510C-GSP Page 1 of 8 TECHNICAL SPECIFICATION LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLE KRSI-JF-510C-GSP Page 2 of 8 1. SCOPE 1.1 ... No jacket cracking and fiber breakage KRSI-JF-510C-GSP Page 6 of 8 Table 5. The Mechanical and Environmental Performance of the Cable (continued) ITEMS TEST METHOD AND ACCEPTANCE CRITERIA Cable ... FRP(Fiberglass...
Ngày tải lên: 05/11/2013, 12:15
Tài liệu Datasheet - FO - Cable - In & Outdoor Loose Tube - HIGHLIGH doc
... HIGHLIGHT ® Outdoor Loose Tube Multimode & Singlemode Fibre Cable
Ngày tải lên: 09/12/2013, 15:15