Cabling Standard - TIA 568 B - Commercial Building Telecommunications Cabling Standard
... ANSI /TIA/< /b> EIA -5 6 8- B. 2-4 < /b> Solderless Connection Reliability Requirements for Copper Connecting Hardware ANSI /TIA/< /b> EIA -5 6 8- B. 2-5 < /b> Corrections to TIA/< /b> EIA -5 6 8- B. 2-5 < /b> ANSI /TIA/< /b> EIA -5 6 8- B. 3-1 < /b> Additional ... ANSI /TIA/< /b> EIA -5 6 8- B. 3 OPTICAL FIBER STANDARDS Optical Fiber Cabling < /b> Compone...
Ngày tải lên: 18/10/2013, 13:15
... assembly. TIA-< /b> 56 8- B. 1-7 < /b> 16 4.2.4 A-to -B patch cords As shown in Figure 8, A-to -B patch cords shall be built as specified in ANSI /TIA/< /b> EIA -5 6 8- B. 1 clause 10.3.3 and ANSI /TIA/< /b> EIA -5 6 8- B. 3 ... fibers. 2. The A-to-A patch cord is a special application cable assembly as per section 6.1 of TIA/< /b> EIA -5 6 8- B. 3. TIA-< /b...
Ngày tải lên: 22/10/2013, 11:15
... applicable requirements in clause 4 of 25 ANSI /TIA/< /b> EIA -5 6 8- B. 3, clause 4 of ANSI /TIA/< /b> EIA -5 6 8- B. 2, annex K of ANSI /TIA/< /b> EIA -5 6 8- B. 2, 26 annex M of ANSI /TIA/< /b> EIA -5 6 8- B. 2, and clause 7 of this Standard < /b> ... Augmented category 6 shall be 17 backward compatible with categories 3, 5, 5e, and 6 as specified in ANSI /TIA/< /b> EI...
Ngày tải lên: 22/10/2013, 11:15
Cabling Standard - TIA 568 B.2 - Addendum 10 - Draft 4.0
... ANSI /TIA/< /b> EIA -5 6 8- B. 1, Commercial Building Telecommunications Standard < /b> Part 1: General 10 Requirements, 2001 11 ANSI /TIA/< /b> EIA -5 6 8- B. 2, Commercial Building Telecommunications Standard < /b> Part 2: Balanced ... Augmented category 6 shall be 12 backward compatible with categories 3, 5, 5e, and 6 as specified in ANSI /TIA/< /b> EIA -5 6 8-...
Ngày tải lên: 26/10/2013, 19:15
Cabling Standard - TIA 569 A - Commercial Building Standard for Telecom Pathway & Spaces
... original standards documentation must also be satisfied. Design consideration • shall be located as close as practicable to the vertical backbone pathways ANSI /TIA/< /b> EIA 569-A Commercial Building Standard < /b> ... largest conduit. Splice Boxes Splice boxes used with conduit, shall be sized per table 5. 2-3 < /b> of the original standards documents. ANSI /TIA/< /b> EIA 56...
Ngày tải lên: 26/10/2013, 19:15
Cabling Standard - TIA 569 A - Commercial Building Standard for Telecom Pathway & Spaces (FULL VE
... original standards documentation must also be satisfied. Design consideration • shall be located as close as practicable to the vertical backbone pathways ANSI /TIA/< /b> EIA 569-A Commercial Building Standard < /b> ... largest conduit. Splice Boxes Splice boxes used with conduit, shall be sized per table 5. 2-3 < /b> of the original standards documents. ANSI /TIA/< /b> EIA 56...
Ngày tải lên: 04/11/2013, 11:15
Tài liệu Cabling Standard - TIA 607 - Commercial Building Grounding and Bonding Requirements for Telecommu doc
... Bonding Backbone (TBB) • the Telecommunications Main Grounding Busbar (TMGB) • the Telecommunications Grounding Busbar (TGB) • the Telecommunications Bonding Backbone Interconnecting Bonding ... shall: • bond the TMGB to the service equipment (power) ground • be, at a minimum, the same size as the TBB (see below) The Telecommunications Bonding Backbone (TBB) The TBB is...
Ngày tải lên: 10/12/2013, 02:15
Tài liệu Cabling Standard - TIA 606 - Administration Standard for the Telecommunications Infrastructure of ppt
... are bonded to the TGBs. Each TGB shall be marked or labeled. It is recommended that all bonding conductors extended to equipment from any TGB in the building be labeled. Labels should be ... possible to the bonding point at each end of the conductor. The TMGB shall be labeled as "TMBG". Each telecommunications backbone bonding conductor attached to the TMGB shall be m...
Ngày tải lên: 10/12/2013, 02:15
Tài liệu Cabling Standard - TIA 598 A - FO Cable Color Coding doc
... normal premise cabling < /b> because of the size of the sub cables. ANSI /TIA/< /b> EIA 598-A Optical Fiber Cable Color Coding Quang Dung Technology Distribution Company Page 4 of 8 Cable Construction ... may also be used, but is not mandatory for fibers that are identified by their position; eg: ribbon fiber. When a number of fibers (e.g., 6, 12, 18, 24) form a unit/bundle, a...
Ngày tải lên: 09/12/2013, 15:15
Tài liệu Cabling Standard - TIA 758 - Customer Owned Outside Plant pptx
... For EC TC-6 EB-35 For EC TC-8 DB-60 For DB or EC TC-6 DB-100 For DB or EC a DB-120 For DB or EC TC-8 Rigid Non Metallic Schedule 40 For DB or EC TC-2 Rigid Non ... Customer-owned OSP cabling < /b> consists of the backbone cables, splices, terminations, and patch cords or jumpers used for backbone-to-backbone connection. The customer-owned OSP cabling < /...
Ngày tải lên: 10/12/2013, 02:15