... coefficient on Ω in case of unconfined phonons Behaviour of Electromagnetic Waves in Different Media and Structures 260 ][ 7 mV r P E = (14) Fig. 10. Measured power current of the DDR2 ... measuring apparatus and methods, CISPR 16-2-3, pp. 79, 2003. Behaviour of Electromagnetic Waves in Different Media and Structures 266 -...
Ngày tải lên: 19/06/2014, 19:20
... Engineering, Kanazawa University, Kakuma, Kanazawa, 92 0-1 192, Japan 2 Industrial Research Institute of Ishikawa, 2-1 Kuratsuki, Kanazawa, 92 0-8 2 03, Japan ' Fujiseisakusho Co., Ltd., Ha 195 ... modules; manipulator-positioning arm, forceps manipulator, and robotized forceps with a two-DOF bending joint and a grasper. We assumed that target organ was mainly liver and...
Ngày tải lên: 10/08/2014, 05:20
Mechatronics for Safety, Security and Dependability in a New Era - Arai and Arai Part 10 ppt
... specifically included: Natural Capital, Manufactured Capital, Human Capi- tal, Social Capital, and Financial Capital. Each capital asset is composed of a 'stock' that provides a 'flow' ... estimated time for passing following gates can be calculated. In these way, for each building materials types, we can obtain both due time for all demands and...
Ngày tải lên: 10/08/2014, 05:20
Cardiac Catheterization in Congenital Heart Disease: Pediatric and Adult - Part 1 pps
... passages in a review. First published 2006 ISBN -1 3 : 97 8 -1 -4 05 1- 2 2009 ISBN -1 0 : 1- 4 05 1- 2 2005 Library of Congress Cataloging -in- Publication Data Mullins, Charles E. Cardiac catheterization in congenital ... (LMWHs) Enoxaparin (Clexane, Lovenox) Dalteparin (Fragmin) Innohep (Tinzaparin) Ardeparin (Normiflo) Warfarin (Coumadin) Warfarin reversalAPhytonadione (Meph...
Ngày tải lên: 13/08/2014, 12:20
Cardiac Catheterization in Congenital Heart Disease: Pediatric and Adult - Part 2 ppsx
... filled. CO 2 is extremely diffusable and escapes instantaneously into air through any opening, including the tiny opening in the tip of a syringe. If the tip of a syringe full of CO 2 remains open, ... is within the vein and that the vein actually is patent. If the vein is patent and the Medi-Cut™ is well within the vein, the soft J curved wire is reintro- duced through the Medi-Cu...
Ngày tải lên: 13/08/2014, 12:20
Cardiac Catheterization in Congenital Heart Disease: Pediatric and Adult - Part 3 pps
... left in a catheter and/ or within the circulation for more than several min- utes without withdrawing the wire and cleaning it and also clearing and flushing the catheter every several min- utes! In ... should be used to eliminate the forma- tion of thrombi and embolic phenomena from wires. Always introducing and using wires through back- bleed valves with flush ports and maint...
Ngày tải lên: 13/08/2014, 12:20
Cardiac Catheterization in Congenital Heart Disease: Pediatric and Adult - Part 4 pps
... described in detail in this summary. Any therapeutic interventions should definitely be described in detail, including the indications and the hemodynamic and anatomic findings before and after the intervention. ... with- drawn from the system. When using a 4- or 5-French catheter, a 5 ml syringe is filled during the withdrawal, and when using a 6-French or larger catheter, a 10...
Ngày tải lên: 13/08/2014, 12:20
Cardiac Catheterization in Congenital Heart Disease: Pediatric and Adult - Part 5 ppt
... available in the 4-French XMI™, the 5- French XVG™, and the 6-French Xpeedior™, and they all pass over a wire, which makes them more versa- tile for entering precise locations and traversing thrombi in ... significantly larger initial opening in the septum than the opening that is usually found or cre- ated in patients requiring these small fixed communica- tions, and this open...
Ngày tải lên: 13/08/2014, 12:20
Cardiac Catheterization in Congenital Heart Disease: Pediatric and Adult - Part 6 ppt
... 69 (6) : 66 5 67 1. 11. Bonhoeffer P et al. The multi-track angiography catheter: a new tool for complex catheterisation in congenital heart dis- ease. Heart 19 96; 76( 2): 173–177. 12. Joseph G, Mandalay ... systemic vein and a separate indwelling femoral arterial monitoring line. The majority of the hemodynamic and anatomic information is obtained through these lines before th...
Ngày tải lên: 13/08/2014, 12:20
Cardiac Catheterization in Congenital Heart Disease: Pediatric and Adult - Part 7 ppt
... some talent and con- siderable additional time on the part of the operator dur- ing each case. “Sheath-within-a-sheath” technique for the delivery of stentsccombined front-loading and pre-positioned ... occurring in most congenital heart patients. References 1. Mullins CE et al. Implantation of balloon-expandable intra- vascular grafts by catheterization in pulmonary arteries...
Ngày tải lên: 13/08/2014, 12:20
Cardiac Catheterization in Congenital Heart Disease: Pediatric and Adult - Part 8 doc
... Radiology 1 986 ; 160: 723–726. 3. Shaffer KM et al. Intravascular stents in congenital heart dis- ease: short- and long-term results from a large single-center experience. J Am Coll Cardiol 19 98; 31(3): ... creating a “through -and- through” route from a femoral vein, through the right heart and ductus, down the descending aorta and out through a femoral artery sheath/cathete...
Ngày tải lên: 13/08/2014, 12:20
Cardiac Catheterization in Congenital Heart Disease: Pediatric and Adult - Part 9 doc
... CardioSEAL™ and/ or a STARFlex™ device, a 9 11-French short sheath is introduced into the right femoral vein, a 6- or 7-French sheath is introduced into the left femoral vein, and a Quick-Cath™ or ... sheath/dila- tor set is introduced over the wire and advanced into the skin and the vein. With the dilator maintained on continuous flush and the valve of the side port of the sheat...
Ngày tải lên: 13/08/2014, 12:20
Cardiac Catheterization in Congenital Heart Disease: Pediatric and Adult - Part 10 doc
... formation in a vein that has sluggish flow and/ or has been damaged by surgical or catheter inter- vention, including chronic indwelling intravenous catheters and infusions. Occlusions of small veins ... the more chal- lenging and time-consuming procedures in the cardiac catheterization laboratory. A myocardial biopsy usually is accomplished in the cardiac catheterization la...
Ngày tải lên: 13/08/2014, 12:20
Profiles in Cardiac Pacing and Electrophysiology - part 10 docx
... American Board of Internal Medicine Com- mittee, which developed the examination in clinical cardiac electrophy- siology, and has been President of the North American Society of Pacing and Electrophysiology. ... research and teaching roles at national and international levels. In 2001, the North American Society of Pacing and Electrophysiology awarded him the Distinguis...
Ngày tải lên: 14/08/2014, 07:20