Introduction to Modern Liquid Chromatography, Third Edition part 61 pot
... laboratory to the receiving laboratory); if this is not the case, and it rarely is, then the sending laboratory should consider the use of instrumentation common to the receiving laboratory (e.g., ... the regulatory guidelines are deficient, it is wise to write an addendum to the test method (or a separate SOP) that describes the allowable adjustments to a method, with appropriate ev...
Ngày tải lên: 04/07/2014, 01:20
... 158 4.3 Introduction to Individual Detectors, 160 4.4 UV-Visible Detectors, 160 4.4.1 Fixed-Wavelength Detectors, 163 4.4.2 Variable-Wavelength Detectors, 164 4.4.3 Diode-Array Detectors, 165 4.4.4 ... 113 3.6 Autosamplers, 113 3.6.1 Six-Port Injection Valves, 114 3.6.1.1 Filled-Loop Injection, 114 3.6.1.2 Partial-Loop Injection, 115 3.6.2 Autosampler Designs, 116 3.6.2.1 Pull -to- Fill A...
Ngày tải lên: 04/07/2014, 01:20
... reasons: • to avoid an undesirable change in separation due to a sample size that is too large • to increase detection sensitivity for trace analysis, by using the largest possible sample size • to maximize ... 1 to 4, the peak begins to widen and then develops a flat top. For Equation (2.27) and the examples of Figure 2.22, we assume the delivery of an undistorted (i.e., cylindric...
Ngày tải lên: 04/07/2014, 01:20
Introduction to Modern Liquid Chromatography, Third Edition part 15 pot
... the total of the autosampler -to- column plus column -to- detector connections. Sometimes it is advantageous to use a short piece of 0.007-in i.d. tubing between the autosampler and column, so as to ... with pressures up to 6000 psi between the pump and detector, so the tubing must be able to withstand such pressures. Also tubing used to transport the sample from the autosampler to...
Ngày tải lên: 04/07/2014, 01:20
Introduction to Modern Liquid Chromatography, Third Edition part 22 potx
... directed to a photodetector, where it is monitored and converted to an electronic signal for data processing. Because fluorescence is emitted in all directions, it is common to monitor the emitted ... carried out at detector startup identify many potential detector problems and can provide automatic wavelength calibration. The background, or baseline absorbance, of UV detectors can incre...
Ngày tải lên: 04/07/2014, 01:20
Introduction to Modern Liquid Chromatography, Third Edition part 29 potx
... pack- ing particles. To prevent particle aggregation, the interaction of the particle with the slurry liquid should be stronger than interactions between particles. For example, C 8 -orC 18 -modified particles ... as illustrated by the cartoon of Figure 5.25a, the liquid may be acceptable. However, if the particles tend to aggregate as in Figure 5.25b, the liquid is likely a poor cho...
Ngày tải lên: 04/07/2014, 01:20
Introduction to Modern Liquid Chromatography, Third Edition part 30 pot
... REVERSED-PHASE CHROMATOGRAPHY (NARP), 295 6.6 SPECIAL PROBLEMS, 297 6.6.1 Poor Retention of Very Polar Samples, 297 6.6.2 Peak Tailing, 298 Introduction to Modern Liquid Chromatography, Third Edition, by ... and J. J. Kirkland, Introduction to Modern Liquid Chromatography, 2nd ed., Wiley, New York, 1979, ch. 5. 78. H. A. Claessens, M. A. Van Straten, and J. J. Kirkland,...
Ngày tải lên: 04/07/2014, 01:20
Introduction to Modern Liquid Chromatography, Third Edition part 42 pot
... so that on average a change in %B by a factor of two (e.g., a change in mobile phase from 100% B to 50% B) will change values of k by a factor of 2 to 4. Similar plots of log k against log %B ... solute and mobile phase. The reader may prefer to skip to Section 8.2.2 (which provides a practical summary of the discussion below) and return to this section as appropriate. Equation (8.2...
Ngày tải lên: 04/07/2014, 01:20
Introduction to Modern Liquid Chromatography, Third Edition part 53 pot
... column. Because of the increase in pressure due to the smaller particles, it is necessary to reduce the flow rate from 2.0 mL/min in Figure 10.3b to 1.0 mL/min in the separa- tion of Figure 10.3c. ... are usually easy to separate, the potential value of computer simulation may be at best marginal. Another barrier to the use of computer simulation is the belief that the chromatographe...
Ngày tải lên: 04/07/2014, 01:20
Introduction to Modern Liquid Chromatography, Third Edition part 55 pot
... hand. Second, the data system and associated software must be able to convert the HPLC Introduction to Modern Liquid Chromatography, Third Edition, by Lloyd R. Snyder, Joseph J. Kirkland, and John W. ... quantification. One way to minimize this problem is to stop integration when the peak is sure to have left the detector. This can be accomplished by visually determining w...
Ngày tải lên: 04/07/2014, 01:20