Introduction to Modern Liquid Chromatography, Third Edition part 27 doc

Introduction to Modern Liquid Chromatography, Third Edition part 27 doc

Introduction to Modern Liquid Chromatography, Third Edition part 27 doc

... meaning that pressure is required to force water into the pores. If the pressure P is insufficient to force a highly aqueous mobile phase into all the pores of the particle, solute molecules will ... is recommended to store the column with 100% acetonitrile as fill solvent. If the mobile phase is then changed to a lower value of %B while maintaining the column pressure, de-wetting is le...
Ngày tải lên : 04/07/2014, 01:20
  • 10
  • 236
  • 0
Introduction to Modern Liquid Chromatography, Third Edition part 8 doc

Introduction to Modern Liquid Chromatography, Third Edition part 8 doc

... near the top of the triangle (large β). Similarly 2.3 RETENTION 27 which allows the calculation of values of k for each peak in the chromatogram. Visual estimates of k from the chromatogram (based ... instant of time (as in Fig 2.8a), and this will cause the electrons in adjacent atom X to move as shown (due to coulombic repulsion). The result is an instantaneous dipole moment for both...
Ngày tải lên : 04/07/2014, 01:20
  • 10
  • 308
  • 0
Introduction to Modern Liquid Chromatography, Third Edition part 28 docx

Introduction to Modern Liquid Chromatography, Third Edition part 28 docx

... 5.22b), the ligands are further apart, so as to allow access of both narrow and wide molecules (i and j) to the stationary phase. When a molecule has access to the stationary phase, steric exclusion ... surface area of the particle. 5.4.1.2 Shape Selectivity The following, minor digression examines two distinct forms of steric exclusion; for now, the reader may prefer to skip to Sec...
Ngày tải lên : 04/07/2014, 01:20
  • 10
  • 214
  • 0
Introduction to Modern Liquid Chromatography, Third Edition part 37 docx

Introduction to Modern Liquid Chromatography, Third Edition part 37 docx

... solutes 1 to 5 increases in proceeding from the Inertsil to the Symmetry to the Discovery column (note the retention ranges for peaks 1–5 in Fig. 7.9b, indicated at the top of each chromatogram ... C 18 column (5-μm particles); mobile phase, 13% acetonitrile-buffer (buffer is citrate plus phosphate); 2.0 mL/min; 35 ◦ C. Peaks for basic compounds 5 to 7 are shaded. Chromatograms based...
Ngày tải lên : 04/07/2014, 01:20
  • 10
  • 210
  • 0
Introduction to Modern Liquid Chromatography, Third Edition part 71 docx

Introduction to Modern Liquid Chromatography, Third Edition part 71 docx

... CONSIDERATIONS, 715 14.7.1 Thermodynamics of Solute-Selector Association, 715 Introduction to Modern Liquid Chromatography, Third Edition, by Lloyd R. Snyder, Joseph J. Kirkland, and John W. Dolan Copyright ... Reversed-Phase High Performance Liquid Chromatography,Aca- demic Press, New York, 1984. 169. A. M Striegel, W. W Yau, J. J Kirkland, and D. D Bly, Modern Size-Exclusio...
Ngày tải lên : 04/07/2014, 01:20
  • 10
  • 255
  • 0
Introduction to Modern Liquid Chromatography, Third Edition part 76 doc

Introduction to Modern Liquid Chromatography, Third Edition part 76 doc

... donor-acceptor phases have also proved to be valuable tools for SFC enantiomer separation [150, 151]. 14.6.8 Chiral Ion-Exchangers Chiral ion-exchangers utilize ionizable selectors to exploit ... Table 14.3). Eventually CSPs with both π-electron donor and acceptor moieties incorporated into a single selector turned out to be more powerful in terms of broader applicability. Along this .....
Ngày tải lên : 04/07/2014, 01:20
  • 10
  • 240
  • 0
Introduction to Modern Liquid Chromatography, Third Edition part 77 docx

Introduction to Modern Liquid Chromatography, Third Edition part 77 docx

... Development for Gradient Prep-LC, 753 15.6 PRODUCTION-SCALE SEPARATION, 754 Introduction to Modern Liquid Chromatography, Third Edition, by Lloyd R. Snyder, Joseph J. Kirkland, and John W. Dolan Copyright ... 493. 57. K. Tachibana and A. Ohnishi, J. Chromatogr. A, 906 (2001) 127. 58. B. Chankvetadze, C. Yamamoto, and Y. Okamoto, J. Chromatogr. A, 922 (2001) 127. 59. K. G. Lynam...
Ngày tải lên : 04/07/2014, 01:20
  • 10
  • 366
  • 0
Introduction to Modern Liquid Chromatography, Third Edition part 81 doc

Introduction to Modern Liquid Chromatography, Third Edition part 81 doc

... Modern Methods for Extracting Solids, 793 16.9 COLUMN-SWITCHING, 796 Introduction to Modern Liquid Chromatography, Third Edition, by Lloyd R. Snyder, Joseph J. Kirkland, and John W. Dolan Copyright ... removal but also to remove particulates. 16.4 SAMPLE PREPARATION FOR LIQUID SAMPLES Table 16.2 provides an introduction to sample preparation methods for liquid sam- pl...
Ngày tải lên : 04/07/2014, 01:20
  • 10
  • 112
  • 0
Introduction to Modern Liquid Chromatography, Third Edition part 92 doc

Introduction to Modern Liquid Chromatography, Third Edition part 92 doc

... leakage Damaged rotor seal Clean, replace rotor seal; may require stator replacement. External leaks not at fittings Worn rotor seal Clean, replace rotor seal Insufficient rotor -to- seal pressure Adjust Seal-pack ... replace Non-UV detector See Chapter 4 and operator’s manuals Table 17.4 Pressure Problems (Section 17.4.2): Symptoms and Sources Symptom Location/Symptom Possible Source Solution...
Ngày tải lên : 04/07/2014, 01:20
  • 10
  • 106
  • 0
Introduction to Modern Liquid Chromatography, Third Edition part 95 pdf

Introduction to Modern Liquid Chromatography, Third Edition part 95 pdf

... rules, 583–584 structure vs. chromatography, 583–584 Proteomics, multidimensional liquid chromatography, 616–618 Protocol; see Validation, protocol Pseudocritical chromatography, 654 Pump(s), 104–113 active ... U-HPLC High-pressure liquid chromatography, 8 High-priced liquid chromatography; see U-HPLC High-speed liquid chromatography, 8 HILIC, see Hydrophilic interaction chr...
Ngày tải lên : 04/07/2014, 01:20
  • 17
  • 453
  • 0