Power Quality Harmonics Analysis and Real Measurements Data Part 12 docx

Power Quality Harmonics Analysis and Real Measurements Data Part 12 docx

Power Quality Harmonics Analysis and Real Measurements Data Part 12 docx

... the second harmonic is a 120 Hertz waveform (2 times 60 Hertz), the third is a 180 Hertz waveform, and so on. Power Quality Harmonics Analysis and Real Measurements Data 214 4. Brief steel ... 20%, so it is not acceptable and definitely will make adverse affect on the neutral line cable. Power Quality Harmonics Analysis and Real Measurements Data...

Ngày tải lên: 19/06/2014, 08:20

20 341 0
Power Quality Harmonics Analysis and Real Measurements Data Part 2 docx

Power Quality Harmonics Analysis and Real Measurements Data Part 2 docx

... model 2. Power Quality Harmonics Analysis and Real Measurements Data 20 Figure 12 –15 give the three algorithms estimates, for 10% missing data with no noise and with 0.1 standard deviation ... changed and varied. These parameters are the standard Power Quality Harmonics Analysis and Real Measurements Data 28 Fig. 21. Estimated magnitudes o...

Ngày tải lên: 19/06/2014, 08:20

20 346 0
Power Quality Harmonics Analysis and Real Measurements Data Part 4 docx

Power Quality Harmonics Analysis and Real Measurements Data Part 4 docx

... (p 11  c 11 ) x 11 + (p 12  c 12 ) x 12 (101) Power Quality Harmonics Analysis and Real Measurements Data 66 S.A. Soliman, I. Helal, and A. M. Al-Kandari, Fuzzy linear regression for measurement ... the amplitude and phase angles of each harmonic component are time independent, steady state harmonics identification. Power Quality Harmonics Analy...

Ngày tải lên: 19/06/2014, 08:20

20 433 0
Power Quality Harmonics Analysis and Real Measurements Data Part 10 docx

Power Quality Harmonics Analysis and Real Measurements Data Part 10 docx

... Power Quality Harmonics Analysis and Real Measurements Data 170 Zhou, L.H., Fu, Q., Liu, C.S.(2009). Modeling and Control Analysis of a Hybrid Unified Power Quality Conditioner, ... X S ·d C ·Y 2k and X S ·Y Pk , which can be rewritten from (14) as Power Quality Harmonics Analysis and Real Measurements Data 180 force on Harmonic Modeling...

Ngày tải lên: 19/06/2014, 08:20

20 454 0
Power Quality Harmonics Analysis and Real Measurements Data Part 14 docx

Power Quality Harmonics Analysis and Real Measurements Data Part 14 docx

... Power Quality Harmonics Analysis and Real Measurements Data 260 Transactions on Power Delivery, Vol. 23, Issue 2, (april 2008), pp. 974-984, ISSN 0885- 8977. CA8334, Three Phase Power Quality ... Line) Power Quality Harmonics Analysis and Real Measurements Data 258 Fig. 37. Apparent power per phase 1 in the last stage of the melting process...

Ngày tải lên: 19/06/2014, 08:20

20 232 0
Power Quality Harmonics Analysis and Real Measurements Data Part 15 doc

Power Quality Harmonics Analysis and Real Measurements Data Part 15 doc

... farm under study. Power Quality Harmonics Analysis and Real Measurements Data 270 C rectifier and C ac_cable are the capacitive couplings of the rectifier side and underground cable, ... distribution network: (a) phase voltage waveform and (b) FFT analysis of the waveform obtained, at node 5. Power Quality Harmonics Analysis and Real Measurement...

Ngày tải lên: 18/06/2014, 22:20

10 384 0
Power Quality Harmonics Analysis and Real Measurements Data Part 1 pdf

Power Quality Harmonics Analysis and Real Measurements Data Part 1 pdf

... Power Quality Harmonics Analysis and Real Measurements Data, Edited by Gregorio Romero Rey and Luisa Martinez Muneta p. cm. ISBN 978-953-307-335-4 POWER QUALITY HARMONICS ANALYSIS AND ... HARMONICS ANALYSIS AND REAL MEASUREMENTS DATA Edited by Gregorio Romero Rey and Luisa Martinez Muneta Power Quality Harmonics Analysis and R...

Ngày tải lên: 19/06/2014, 08:20

20 446 0
Power Quality Harmonics Analysis and Real Measurements Data Part 3 ppt

Power Quality Harmonics Analysis and Real Measurements Data Part 3 ppt

... this power) . Examination of these curves reveals the following results. The fundamental power and the fourth and sixth harmonics are time-varying. Power Quality Harmonics Analysis and Real Measurements ... and Measurements 31 recorded data set. and computes the voltage and current harmonics magnitude, the voltage and current harmonics phase angle...

Ngày tải lên: 19/06/2014, 08:20

20 397 0
Power Quality Harmonics Analysis and Real Measurements Data Part 5 doc

Power Quality Harmonics Analysis and Real Measurements Data Part 5 doc

... Group , Interharmonics in Power Systems. Power Quality Harmonics Analysis and Real Measurements Data 88 Johnson, R. A. & Wichern, D. W. (2007). Applied Multivariate Statistical Analysis, ... impedance of the transmission and distribution lines, and of the step-down and step-up transformers. Power Quality Harmonics Analysis and Real Measurement...

Ngày tải lên: 19/06/2014, 08:20

20 451 0
Power Quality Harmonics Analysis and Real Measurements Data Part 6 pptx

Power Quality Harmonics Analysis and Real Measurements Data Part 6 pptx

... transformer for power system harmonic frequencies, IEEE Transactions on Power Delivery, Volume 10, Issue 4, Oct. 1995 Power Quality Harmonics Analysis and Real Measurements Data 92 Wideband analysis ... Power Quality Harmonics Analysis and Real Measurements Data 90 of metering apparatus or protection relays extensively used in power system. VT...

Ngày tải lên: 19/06/2014, 08:20

20 404 0
w