... steam injec- tion, steam extracted from the bottoming cycle is typically injected directly into the GT’s combustor, Fig. 3. For advanced GTs, the steam source may be extracted from either the high-pressure ... turbine exhaust, an h-p extraction, or the heat recovery steam generator’s (HRSG) h-p section. Cycle economics and plant-specific considerations determine the steam extrac- tion point. For example, ... be supplied from either the HRSG or an h-p turbine extraction ahead of the reheat section. Based on installed-cost considerations alone, extracting steam from the HRSG is favored for peaking service
Ngày tải lên: 04/07/2014, 07:20
... Trang 1 TỔNG-CỤC KHÍ TƯƠNG THỦY-VXÄĐ TRUNG TAM KHÍ TƯỢNG THỦY VĂN BIỂN Trang 2 TỔNG CỤC KHÍ TƯỢNG THUỶ VĂN _ TRUNG TÂM KHÍ TUGNG THUY VAN BIEN SO TAY TRA cou ‘CAC DAC TRUNG ... lĩnh vực khí tượng nhiệt đới và nghiên cứu bão ký năm 1980, những năm qua, ngành Khí tượng Thuỷ văn (KTTV) của hai nước đã thoả thuận tiến hành đề tài số 5 : “Lập sách tra cứu các điều kiện khí tượng ... các trạm khí tượng hải văn ven bờ (1986 - 1995), chúng tôi tiến hành biên soạn cuốn sách “Số tay tra cứu các đặc trưng KTTTV vùng thêm luc địa Việt Nam” Tham gia biến soạn sách tra cứu có : TS
Ngày tải lên: 06/12/2015, 16:57
Ebook sổ tay tra cứu các đặc trưng khí tượng thủy văn vùng thềm lục địa việt nam phần 2 TS nguyễn thế tưởng
... bảng tra cứu về chế độ piĩ, chúng tơi đã sử dụng Trang 2 Cơn Đảo, Phú Quốc và số liệu ship vùng biển Qui Nhơn, Nha Trang, Phú Quí, Vũng Tàu - Cịn Đảo và Phú Quốc Để đạt được các bảng tra cứu ... được Tổng cục Khí tượng Thuỷ văn - kiểm định Số liệu khí tượng sau khi đo đạc được xử lý tin cậy và lưu trữ tại kho tư liệu thuộc Trung tâm Tư liệu Khí tượng Thuy văn và Trung tâm Khí tượng Thuy ... tốc độ giĩ cịn được thực hiện trên cơ sở áp dụng hàm Gumbel và cơ sở của phương pháp trình bày dưới đây II.2 Cơ sở phương pháp 1 Chuối số liệu cực trị Trong khí hậu học, các chuỗi số liệu cực
Ngày tải lên: 06/12/2015, 16:57
SỔ TAY TRA CỨU HƯỚNG DẪN SỬ DỤNG CÁC THÔNG TIN VỀ KHÍ HẬU NÔNG NGHIỆP VÀ TẬP BẢN ĐỒ PHÂN VÙNG KHÍ HẬU NÔNG NGHIỆP
... BÁO CÁO SỔ TAY TRA CỨU HƯỚNG DẪN SỬ DỤNG CÁC THƠNG TIN VỀ KHÍ HẬU NƠNG NGHIỆP VÀ TẬP BẢN ĐỒ PHÂN VÙNG KHÍ HẬU NƠNG NGHIỆP (Thuộc mục 1.6.1 Thuyết minh) Cơ quan thực hiện: Viện Khoa học Khí tượng ... ĐỂ PHÂN VÙNG KHÍ HẬU NƠNG NGHIỆP KHU VỰC BẮC TRUNG BỘ VÀ DUYÊN HẢI MIỀN TRUNG BÁO CÁO SỔ TAY TRA CỨU HƯỚNG DẪN SỬ DỤNG CÁC THÔNG TIN VỀ KHÍ HẬU NƠNG NGHIỆP VÀ TẬP BẢN ĐỒ PHÂN VÙNG KHÍ HẬU NƠNG ... TRA CỨU HƯỚNG DẪN SỬ DỤNG CÁC THƠNG TIN VỀ KHÍ HẬU NƠNG NGHIỆP VÀ TẬP BẢN ĐỒ PHÂN VÙNG KHÍ HẬU NƠNG NGHIỆP Lý giải số khái niệm 1.1 Khí tượng, thời tiết khí hậu gì? Khí tượng tượng vật lý diễn khí
Ngày tải lên: 02/08/2020, 11:38
Tài liệu Sổ tay tra cứu tính năng kỹ thuật ô tô P1 pdf
... biên soạn tài liệu Sổ tay tra cứu tính năng kỹ thuật ô tô. Do số lợng và chủng loại ô tô sử dụng ở nớc ta rất đa dạng nên trong tài liệu này chúng tôi chỉ nêu những tính năng cơ bản của ô tô và ... tốc lớn nhất, km.h-1 Tiêu hao nhiên liệu ở vận tốc 90 km.h-1, l/100 km Động cơ đốt trong Cơ khí , 4 số truyền Cơ khí , 2 số truyền Loại tang phanh, hai nhánh độc lập có trợ lực chân không 215/90-15C, ... lõm - con lăn 2 ren 20,3 Cơ khí Hệ thống phanh - Phanh công tác - Phanh dừng Tang trống, loại guốc ở tất cả các bánh xe, dẫn động thuỷ lực. Dẫn động cơ khí Hệ thống treo (Trớc và
Ngày tải lên: 23/01/2014, 04:20
So tay tra cuu ccd docx
... Bảng tính nhq* theo n* và P* P* = P1/ P Tra cuu thiet bi dien 13 Tra cuu thiet bi dien Bảng 1-11 Bảng tra trị số kmax theo ksd và nhq (phụ lục I.6 trang 256, thiết kế cấp điện, của Ngô ... điều chỉnh 2x 2,5% do ABB chế tạo (bảng 1.2 trang 20 - số tay lựa chọn và tra cứu thiết bị điện 0,4 đến 500 kV, Ngô... 2740 2030 2810 2210 2990 Tra cuu thiet bi dien 107 0 107 0 107 0 ... bị điện Đông Anh chế tạo (bảng 1.7 trang 33 - số tay lựa chọn và tra cứu thiết bị điện 0,4... 3290 0,6 7,5 3160 2680 4010 0,6 7,5 3170 2690 4050 5 6 7 8 9 Tra cuu thiet bi dien 143 0 143
Ngày tải lên: 27/06/2014, 22:20
Sổ tay kỹ sư cơ khí P2 pptx
... refrigerant mole- cule has in destroying ozone in the stratosphere. When a CFC molecule is struck by ultraviolet light in the stratosphere, a chlorine atom breaks off and reacts with ... ,2-trichlorotrifluoro-ethane 114 1 ,2-dichlorotetrafluoro-ethane 1 23 2,2-dichloro- 1,1,1 -trifluoroethane 125 pentafluoroethane 134a 1,1,1,2-tetrafluoroethane 170 ethane Propane Series 290 ... properties make it an ideal heat- transfer fluid with reasonable pumping costs, pressure drop, and flow rates. As a refrigerant, ammonia provides high heat transfer except when affected
Ngày tải lên: 04/07/2014, 00:20
Sổ tay kỹ sư cơ khí P5 doc
... Heat transfer occurs by convection, conduction, and radiation mechanisms. A vacuum space ideally eliminates convective and conductive heat transfer but does not interrupt radiative transfer. ... regenerator surface area, m 2 U 0 = overall heat transfer coefficient uncorrected for hysteresis, kcal/m 2 • hr • 0 C U = overall heat transfer coefficient C w , C 0 = heat capacity ... transfer. Thus heat transfer through a vacuum space can be calculated from the classic equation: q = 0-AF 12 (T 4 , - T 4 ) (63.10) where q = rate of heat transfer, J/sec cr
Ngày tải lên: 04/07/2014, 00:20
Sổ tay kỹ sư cơ khí P6 pptx
... transfer, associated with the decrease in dry bulb temperature, and latent heat transfer, associated with the decrease in humidity ratio. We may also express the latent heat transfer ... transfer—conduction, convection, and radiation—are important in building heat gain and loss. Thermal conduction is heat transfer between parts of a continuum because of the transfer ... W 2 -W 1 m w w Figure 64.7 shows the procedure where a straight line is laid out parallel to the line on the protractor through state point 1. The intersection of this line
Ngày tải lên: 04/07/2014, 00:20
Sổ tay kỹ sư cơ khí P8 pdf
... concentrations, ad- versely impact human health and/or the quality of the environment. Those pollutants for which health criteria define specific acceptable levels of ambient concentrations ... level of solar radiation trapped in the Earth's atmosphere, and compounds such as chlorofluorocarbons (CFCs) that react with and destroy ozone in the stratosphere, reducing the ... addition, increased soot blowing is also required to maintain clean heat transfer surfaces and prevent reduced heat-transfer efficiencies when furnace sorbent in- jection is used. Fluid
Ngày tải lên: 04/07/2014, 00:20
Sổ tay kỹ sư cơ khí P9 pps
... ranging from what is usually considered ordinary filtration or removal of solid particles through ultrafiltration and hyperfiltration, which can remove large molecules, to reverse ... contaminant at low concentrations, the equilibrium concentration of contaminant in air contacting the aqueous phase bears a linear relationship to the liquid concen- tration. This line passes ... on a plot of gas concentration versus liquid concen- tration would be to move down that curve toward the origin. In a single-tank continuous operation, concentration of the liquid
Ngày tải lên: 04/07/2014, 00:20
Sổ tay kỹ sư cơ khí P10 docx
... aerospace and defense; construction; product development; public sector water, transportation and urban develop- ment; strategic thrusts; and in all kinds of team-related activity, including ... success. Next, strategies should be developed to meet the "inducements" necessary to satisfy the stakeholders, especially the critical stakeholders. Once these strategies ... success factors (CSF's) for the attainment of these strategies as well as impediments to the attainment of these strategies should be identified. For each CSF, a performance
Ngày tải lên: 04/07/2014, 00:20
Sổ tay kỹ sư cơ khí P11 pdf
... TV Transmission System Project We illustrate the process of network planning by constructing a network for the TV transmission system whose work breakdown structure was illustrated ... project is to construct a television transmission tower and an associated building for housing television transmission equipment.* As a contractor for the project, we are given ... are essential. We turn now to the network for the transmission tower shown in Fig. 67.17. The transmission network is quite straightforward, with three notable exceptions. First,
Ngày tải lên: 04/07/2014, 00:20
Sổ tay kỹ sư cơ khí P12 ppsx
... of any strategic plan, operational initiative, or specific project undertaking. The mandate for managers is clear: they must weave together the best practices of both traditional ... facilitating solutions to technical, adminis- trative, and personal problems. It is a very important need, which, if not satisfied, often leads to frustration, conflict, and poor-quality ... management. In the traditional organization, position power comes largely in form of legitimate authority, reward, and punishment and is provided by these organizations. In contrast, engineering
Ngày tải lên: 04/07/2014, 00:20
Sổ tay kỹ sư cơ khí P17 docx
... to obtain registration is made. Third-party registrars are generally contracted for three years. In addition to the initial assessment for registration, the registrar may be asked ... require third-party registration of quality systems to TE 9000. These registrations will be performed by registrars already accredited to perform ISO 9000 registrations. Although a ... of information on registrars in the United States. The Registrar Accreditation Board (RAB) is the U.S. agency that accredits agencies to serve as registrars. The RAB is a wholly
Ngày tải lên: 04/07/2014, 00:20
Sổ tay kỹ sư cơ khí P19 pptx
... operator to be unduly exerted to continue performing. Such exertion is termed strain as in "stress and strain." Common physical stressors in industrial workplaces are poor illumination, ... area. Therefore, you will continually need to train new employees in the use of the protective equipment they will handle. After the training phase comes the fitting and adjustment ... leadership to their employees must provide appropriate training and experiential opportunities to current supervisors and supervi- sory trainees alike. 74.10.2 Elements of Accident Preventionf
Ngày tải lên: 04/07/2014, 00:20
Sổ tay kỹ sư cơ khí P20 pdf
... law (e.g., contracts in restraint of trade), or because they violate public policy (e.g., contracts to defraud others). Problems with contracts can occur when the contract terms ... that, at least when the contract is formed, both parties see an advantage in contracting for the anticipated performance. If the subject matter of a contract (either the consideration ... the breaching party. An oral contract can constitute just as binding a commitment as a written contract, although, by statute, some types of contracts are required to be in writing.
Ngày tải lên: 04/07/2014, 00:20
Sổ tay kỹ sư cơ khí P21 doc
... been granted by the Commissioner of Patents and Trademarks to permit foreign filing. This prohibition period enables the Patent and Trademark Office to review newly filed applications, ... that the files of the Public Search Room of the Patent and Trademark Office are incomplete. The Patent and Trademark Office estimates that as many as 7% of the Search Room ... application within one year from the filing date of a provisional application, the Patent and Trademark Office will destroy the provisional application once it has been pending a full
Ngày tải lên: 04/07/2014, 00:20
Sổ tay tính toán cơ khí P2 ppt
... intake structure and trash rack to use Every intake structure must provide room for the following components: (a) cir- culating-water or makeup-water pumps; (b) trash racks; (c) trash-removal screens—either ... Usually, the trash rack is inclined and bars are spaced at about 3-in (76.2-mm). The trash rake may be mechanical or manual. The two usual rake designs are the unguided rake, which rides on the trash ... problems. Traveling screens follow the trash racks. These usually are of the vertical flow- through type. European practice uses alternative screens, such as center-flow, dual- flow, and drum screens. Traveling
Ngày tải lên: 04/07/2014, 07:20
Sổ tay tính toán cơ khí P6 ppt
... Determine if an internal-combustion (I-C) engine cogeneration facility will be ec- onomically attractive if the required electrical power and steam services can be served by a cycle such as that ... post-Title-24 mid-rise office buildings. Title 24 is a section of the State of California Administrative Code that deals with energy-conservation standards for construction applicable to office ... evaporative chilling. When waste heat is plentiful, desiccant cooling and cogener- ation become attractive. In coupling the continuously available heat-rejection capacity of packaged cogeneration
Ngày tải lên: 04/07/2014, 07:20
Bạn có muốn tìm thêm với từ khóa: