Refrigeration and Air-Conditioning pdf
... determined by the requirements of the air conditioned enclosure BS 5643: 1984 Refrigeration and Air- Conditioning Third edition A R Trott and T Welch OXFORD AUCKLAND BOSTON JOHANNESBURG MELBOURNE ... Industrial uses of refrigeration 223 Air and water vapour mixtures 227 Air treatment cycles 240 Practical air treatment cycles 255 vi 26 27 28 29 30 31 32 33 34 35 Contents Air- conditioning load ... draught air and a vertical plane surface ([1], Chapter 3, Table 6) gives: h′ = 5.6 + 18.6V Refrigeration and Air- Conditioning Table 1.3 Number Sign Parameters Reynolds Re Grashof Gr Nusselt Nu Prandtl...
Ngày tải lên: 05/03/2014, 19:20
... addresses HFC and PFC emissions from users of refrigeration and air con ditioning equipment including household refriger ation, domestic air conditioning and heat pumps, mobile air conditioning, ... estimating HFC and PFC emissions from refrigeration and air conditioning equip ment use This method requires available data on the total inventory of refrigerants at the beginning and end of the ... methods, one for refrigeration and air conditioning equipment and a second for fire suppression equipment See Chapter of the Climate Leaders Design Principles for more on materiality and significance...
Ngày tải lên: 08/03/2014, 19:20
... Course Title Prerequisites Refrigeration and Air Conditioning Major Mechanical Technology Air Conditioning Systems and Equipment RAC 111 & RAC 112 Refrigeration and Air Conditioning Code RAC 202 ... Course Title Prerequisites Refrigeration and Air Conditioning Major Mechanical Technology Refrigeration Systems and Equipment RAC 111 & RAC 112 Refrigeration and Air Conditioning Code RAC 201 ... Desert Air Coolers Components of Simple Ref & A/C Units Car A/C Systems - 28 - Department of Mechanical Technology References: Refrigeration and Air Conditioning “Modern Refrigeration and Air Conditioning ...
Ngày tải lên: 01/04/2014, 00:20
Refrigeration and Air Conditioning IV (Equypment Cooling) pdf
... instruction in refrigeration and air conditioning The scope of this subcourse takes in unit components of the absorption system, including their functions and maintenance; water treatment methods and their ... direct expansion (D/X), and (3) reheat We will discuss the application of these coils, their use and control, and the valves and dampers which control the flow of water and air D/X Coil In equipment ... passing score for ACCP material is 70% Preface YOU HAVE studied the fundamentals and commercial refrigeration and air- conditioning systems This final volume deals with another phase of your career...
Ngày tải lên: 27/06/2014, 05:20
Refrigeration and Air-Conditioning.Refrigeration: The process of removing heat ppt
... determined by the requirements of the air conditioned enclosure BS 5643: 1984 Refrigeration and Air- Conditioning Third edition A R Trott and T Welch OXFORD AUCKLAND BOSTON JOHANNESBURG MELBOURNE ... Industrial uses of refrigeration 223 Air and water vapour mixtures 227 Air treatment cycles 240 Practical air treatment cycles 255 vi 26 27 28 29 30 31 32 33 34 35 Contents Air- conditioning load ... draught air and a vertical plane surface ([1], Chapter 3, Table 6) gives: h′ = 5.6 + 18.6V Refrigeration and Air- Conditioning Table 1.3 Number Sign Parameters Reynolds Re Grashof Gr Nusselt Nu Prandtl...
Ngày tải lên: 27/06/2014, 17:20
Refrigeration and Air-Conditioning Refrigeration: The process of removing heat ppt
... determined by the requirements of the air conditioned enclosure BS 5643: 1984 Refrigeration and Air- Conditioning Third edition A R Trott and T Welch OXFORD AUCKLAND BOSTON JOHANNESBURG MELBOURNE ... Industrial uses of refrigeration 223 Air and water vapour mixtures 227 Air treatment cycles 240 Practical air treatment cycles 255 vi 26 27 28 29 30 31 32 33 34 35 Contents Air- conditioning load ... draught air and a vertical plane surface ([1], Chapter 3, Table 6) gives: h′ = 5.6 + 18.6V Refrigeration and Air- Conditioning Table 1.3 Number Sign Parameters Reynolds Re Grashof Gr Nusselt Nu Prandtl...
Ngày tải lên: 27/06/2014, 18:20
REFRIGERATION AND AIR CONDITIONING IV doc
... instruction in refrigeration and air conditioning The scope of this subcourse takes in unit components of the absorption system, including their functions and maintenance; water treatment methods and their ... direct expansion (D/X), and (3) reheat We will discuss the application of these coils, their use and control, and the valves and dampers which control the flow of water and air D/X Coil In equipment ... passing score for ACCP material is 70% Preface YOU HAVE studied the fundamentals and commercial refrigeration and air- conditioning systems This final volume deals with another phase of your career...
Ngày tải lên: 27/06/2014, 18:20
Refrigeration and Air Conditioning 3 E Part 1 doc
... determined by the requirements of the air conditioned enclosure BS 5643: 1984 Refrigeration and Air- Conditioning Third edition A R Trott and T Welch OXFORD AUCKLAND BOSTON JOHANNESBURG MELBOURNE ... Industrial uses of refrigeration 223 Air and water vapour mixtures 227 Air treatment cycles 240 Practical air treatment cycles 255 vi 26 27 28 29 30 31 32 33 34 35 Contents Air- conditioning load ... draught air and a vertical plane surface ([1], Chapter 3, Table 6) gives: h′ = 5.6 + 18.6V Refrigeration and Air- Conditioning Table 1.3 Number Sign Parameters Reynolds Re Grashof Gr Nusselt Nu Prandtl...
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 2 potx
... energy (Figure 2.12) The refrigeration cycle 27 Air inlet Cooling air out Expander Cold air to process Heat exchanger Compressor Cooling air in Fan Figure 2.12 2.11 Air cycle cooling Thermoelectric ... glass seals Small compressors will be fully hermetic, i.e having the motor and all working parts sealed within a steel shell, and so not accessible for 46 Refrigeration and Air- Conditioning (a) ... plant room and into the atmosphere If the plant room is outside or on the roof of a building, the escaping ammonia will drift away from the refrigeration plant 34 Refrigeration and Air- Conditioning...
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 3 pptx
... condenser, and manufacturers will give ratings for ‘standard’ and ‘quiet’ products It will be recognized that the low specific heat capacity and high 66 Refrigeration and Air- Conditioning Figure 6.2 Air- cooled ... filtered and kept dry The oil as seen through the crankcase sight glass should remain 62 Refrigeration and Air- Conditioning transparent If it takes on a white, emulsified appearance it is wet and ... pressure and lowest power Air- cooled surfaces may be cleaned by brushing off the accumulation of dust and fluff where the air enters the coil, by the combination of a high-pressure air hose and a...
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 5 ppt
... tentative temperature differences of 15 K and 12 K 126 Refrigeration and Air- Conditioning Table 10.2 Climate Air- cooled Evaporative Dry bulb (°C) South UK Scotland Mediterranean Desert Tropical humid ... this, insulate the pipe 11.9 Vibration Compressors and pumps will transmit vibration to their connecting pipework 136 Refrigeration and Air- Conditioning Water and brine pumps may be isolated with ... custom-built systems and, for these, selected outside a factory 128 Refrigeration and Air- Conditioning It is usual to select a thermostatic expansion valve for the maximum duty and at the summer...
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 6 pdf
... having the air cooling coil with drip tray under, expansion valve, fan and motor, air filters, inlet and outlet grilles They may also include dampers and duct connections for return and fresh air, ... installation, and the interpretation of catalogue data has many pitfalls Errors in application stem mainly from a lack of understanding 160 Refrigeration and Air- Conditioning of the requirement and a ... would now be two deep along the sides and four-deep 172 Refrigeration and Air- Conditioning islands However, with racking, the pallets could be stacked four high and possibly five A provisional arrangement...
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 7 pps
... protect the surface from collision damage and ensure an air space for circulation of the air from the evaporators Since timber 184 Refrigeration and Air- Conditioning Operating motor Overhead track ... crushed ice in 192 Refrigeration and Air- Conditioning their small boats Fresh fish is stored and transported with layers of ice between and over the fish, cooling by conduction and keeping the product ... type and flavour The presence of this mixture of constituents means that the freezing 196 Refrigeration and Air- Conditioning process covers a wide band of temperatures, starting just below 0°C and...
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 8 pot
... example taken) 230 Refrigeration and Air- Conditioning Since most air- conditioning calculations are based on weights of air and moisture, percentage saturation is usually employed, and moisture content ... between inside and outside air, and the usage of the doors The latter is affected by the existence of airlocks and curtains [49] Standard textbooks give data on which to base an estimate, and this ... for the Refrigeration and Air- Conditioning 220 process The heat of respiration varies with the sugar or starch content of the product, the variety, and its temperature, and is between and 120...
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 9 doc
... K, and it is sometimes convenient and quicker to calculate on the basis of constant wet bulb (This 246 Refrigeration and Air- Conditioning correlation applies only to the mixture of dry air and ... Example 24.13 Air enters a packaged dehumidifier (see Chapter 29) at 25C dry bulb and 60% saturation It is cooled to 10C dry 254 Refrigeration and Air- Conditioning bulb and 90% saturation, and then ... pressure of 101.325 kPa PSYCHROMETRIC CHART CIBSE Air and water vapour mixtures 235 Moisture content (kg/kg) (dry air) 236 Refrigeration and Air- Conditioning Specific enthalpy % saturation Wet...
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 10 pps
... Refrigeration and Air- Conditioning Air- conditioning load estimation 269 balanced by the loss of an equal amount at the inside condition, whether by intent (positive fresh air supply or stale air extract) ... between them to pre-treat the incoming air For the air flow in Example 26.2, and in Figure 26.5, it would be possible to save 270 Refrigeration and Air- Conditioning 5.5 kW of energy by apparatus ... total pressure If air is in motion, it will have kinetic energy of 0.5 × mass × (velocity)2 Example 27.2 If m3 of air at 20°C dry bulb, 60% saturation, and Refrigeration and Air- Conditioning 274...
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 11 pptx
... cleaned easily 296 Refrigeration and Air- Conditioning 27.12 Cleanliness and cleaning of ducting Filters in air- conditioning systems not remove all the dirt from the air, and this will settle ... The air- conditioning unit will now stand on the floor, taking warm air from the upper part of the room and blowing it down into the false floor (see Figure 28.10) Fresh air unit Filter Air- handling ... Dehumidifiers and air drying 317 Suction Damp cool air Discharge Evaporator Warm Condenser dry air Compressor ate W r Expansion valve Liquid (a) Cool damp air Air-to -air Warm dry air Condenser...
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 12 pps
... coil = 20°C Air off coil at full air flow = 11°C Evaporating temperature at full air flow = 3°C ln MTD at full air flow, 17 – = 11.94 K ln (17/8) 340 Refrigeration and Air- Conditioning Air off coil ... 11.10) 336 32.4 Refrigeration and Air- Conditioning Calibration and final commissioning Final adjustments should now be made to the following, and any other items of this sort: Air flows, by setting ... 0.4 bar and is used in a servo 328 Refrigeration and Air- Conditioning piston, diaphragm or bellows to actuate the controlled device (See Figure 31.3.) Signal air pressure 0.2–0.9 bar Air supply...
Ngày tải lên: 12/08/2014, 00:20
Refrigeration and Air Conditioning 3 E Part 13 ppsx
... tube test for refrigeration oils ASHRAE Transactions, 1965 370 Refrigeration and Air- Conditioning 19 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Systems Handbook, ASHRAE, ... turn, can be derived other units for use in the calculation of refrigeration and air- conditioning loads: 368 Refrigeration and Air- Conditioning Specific heat capacity Specific enthalpy Thermal ... 5°C and with ambient air at 43°C Estimate the duty with ambient air at 52°C Refrigeration and Air- Conditioning 360 Some assumptions must be made regarding the condenser coil performance, and...
Ngày tải lên: 12/08/2014, 00:20