high speed dome camera user manual

High-Speed WLANs and WLAN Security

High-Speed WLANs and WLAN Security

... is a proposed standard that will increase the speed of WLANs to 108 Mbps • 802.11r is a proposed standard for fast roaming • HiperLAN/2 is a high- speed WLAN specification that is similar to the ... Multiplexing (OFDM) – Splits a high- speed digital signal into several slower signals running in parallel – Sends the transmission in parallel across several lower -speed channels 23 Summary (continued) • OFDM ... short-range, high- speed wireless digital communications • U-NII spectrum is segmented into four bands – Each band has a maximum power limit • Outside the United States – 5 GHz band is allocated to users...

Ngày tải lên: 13/09/2012, 10:52

24 477 1
High Speed Downlink Packet Access

High Speed Downlink Packet Access

... Node-B. Thông tin về chất lượng kênh nhanh cho phép bộ lập lịch gói nhanh phục vụ user chỉ khi điều kiện của user này là thích hợp. Quá trình lập lịch gói nhanh và đặc tính chia sẻ theo thời ... thống, mã này thường được sử dụng ở các cell không có khả năng xác định nhiều người sử dụng (MultiUser detection). MS sẽ được thông báo có sử dụng mã scrambling thứ cấp hay không qua bản tin Cho...

Ngày tải lên: 20/11/2012, 11:31

65 452 1
Sinometer-MS8211-Digital-Multimeter-User-Manual

Sinometer-MS8211-Digital-Multimeter-User-Manual

... Thebatteryisnotsufficientforproperoperation. 1.4MAINTENANCE 1.4.1Pleasedonotattempttoadjustorrepairthemeterbyremovingtherearcasewhilevoltageisbeing WARNING BEEXTREMELYCAREFULINTHEUSEOFTHISMETER.Improperuseofthisdevice canresultinelectricshockordestroyofthemeter.Followallsafeguardssuggestedinthis manualandthenormalsafetyprecautionsusedinworkingwithelectricalcircuits. Donotservicethisdeviceifyouarenotqualifiedtodoso. To ensuresafeoperation,andinordertoexploittothefullthefunctionalityofthemeter, pleasefollowthedirectionsinthissectioncarefully. ThismeterhasbeendesignedaccordingtoIEC-1010concerningelectronicmeasuringinstrumentswith anovervoltagecategoryCATⅢ600Vandpollution2. Followallsafetyandoperatinginstructionstoensurethatthemeterisusedsafelyandiskeptingood operatingcondition. Withproperuseandcare,thedigitalmeterwillgiveyouyearsofsatisfactoryservice. 1.1PRELIMINARY 1.1.1Whenusingthemeter,theusermustobserveallnormalsafetyrulesconcerning: -Protectionagainstthedangersofelectricalcurrent. -Protectionofthemeteragainstmisuse. 1.1.2Whenthemeterisdelivered,checkthatithasnotbeendamagedintransit. 1.1.3Whenpoorconditionunderharshpreservationorshippingconditionscaused,inspectandconfirm thismeterwithoutdelay. 1.1.4Beforeusingtocheckforvoltage,alwaystestthemeteronaknownlivecircuittoverifythatthe detectfunctionofthemeterisworkingproperly. 1.1.5 Test leadortestclipmustbeingoodcondition.Beforeusingverifythattheinsulationontestleador testclipisnotdamagedand/ortheleadswireisnotexposed. 1.1.6Fullcompliancewithsafetystandardscanbeguaranteedonlyifusedwithtestleadssupplied. Ifnecessary,theymustbereplacedwiththesamemodelorsameelectricratings. User& apos;sManual SinoMeter MS8211 ⑵ Test Clip:ElectricRatings600V10Aonepiece ⑶Battery:1.5V,AAAtwopieces ⑷InstructionManualonepiece RangeResolutionFunction 0.001VDisplay:readapproximateforwardvoltageof diode -ForwardDCCurrent:approx.1mA -ReversedDCVoltage:approx.1.5V -OverloadProtection:250VDCorrmsAC 3.2.6ACVoltageDetect RangeTEST Sensitivity Voltagesensitivity>50V,adjustcontinuously Frequency50Hz Distance<150mm(changealongwiththesensitivity) -Non-contactdetecting 4.OPERATINGINSTRUCTION 4.1 DATA HOLD Ifyouneeddataholdwhenmeasuring,youcanputon“DATA-H”button,itwillholdthereading;ifyouput thebuttonagain,dataholdisnotcontinue. 4.2MAXIMUMVALUEMEASURINGANDHOLD Attherangeofvoltage,youcanputon“MAX.H”button,itwillholdthemaximumvalue;ifyouputthe buttonagain,themaximumvaluewillnotbeheld. 4.3FUNCTIONTRANSFORM Putdownthe"FUNC."whenmeasuringthevoltage.MeterwillbetransformedbetweenDCandAC range.Put"FUNC."whenmeasuringtheresistance,diodeandcontinuity,meterwilltransformamong them. 4.4RANGETRANSFORM Theautorangeisusedwhenmeasuringthevoltageandresistance.Putdownthe"RANGE"ifthe manualrangeisneeded.Eachtimeyouputdown,rangewillgoupward;theminimumrangeis transformedif"RANGE"isputdownatthemaximumrange.Ifthe"RANGE"isputdownmorethantwo seconds,autorangeisusedagain. 4.5AUTOPOWEROFF Ifthere’snoanyoperationwithinfifteenminutesafterpowerison,meterwillautopoweroffwithfiveshort soundsandalongsoundinaminute. Afterautopoweroff,ifstirthetransformswitchorputdownanybuttonof“FUNC.”, “DATA-H”,”MAX.H”,”RANGE”,meterwillrecovertheworkingcondition. Ifpressesthe“FUNC.”whenpowerison,autopoweroffdisable. NOTE: AttheTESTrange(ACVdetecting),thereisnoautopowerofffunction 4.6PREPARATIONFORMEASUREMENT 4.6.1Setthetransformswitchtotherightrange.Atthemanualrange,whenthevaluescaletobe 4.12.1Rotatetheprobesocketanti-clockwisetospintheprobeintothemeter. 4.12.2Setthetransformswitchatthe Vrangeposition. 4.12.3Besurethatthedisplayisnot shown“ ”,otherwise,the batteryshouldbereplaced. 4.12.4Setthetransformswitchto theTESTrange.ThenthegreenLEDoftheLEDIndicatorisbright. 4.12.5Rotatethesensitivityadjustingknobinthemiddleofthetransformswitchanti-clockwise,setthe meter tothehighestdetectingsensitivityinordertoenlargethedetectingrange. 4.12.6Puttheprobesocketclosetotheleadorthepowersocket,IfACelectricalvoltageispresent,the redLEDIndicatorwhichinfrontofthemeterwillflashandtheaudiblewarningwillsound. 4.12.7Intheplaceswithmanyleadsandjacks,rotatethesensitivityadjustingknobinthemiddleofthe transformswitchclockwise,setthemetertothelowerdetectingsensitivityinordertoconfirmwhichone iselectriferous. NOTE: -WhenusingACVdetectingfunction,alwayssetthemetertothehighestsensitivity. -Inthisrange,eventhoughthereisnoanysoundandlightindication,themeterwillstillconsume electricity. -Thereisnoautopowerofffunctioninthisrange. -AlwayssetthepowerswitchtotheOFFpositionwhenthemeterisnotinuse. 5.MAINTENANCE 5.1BATTERYREPLACEMENT WARNING Beforeattemptingtoopenthebatterycoverofthemeter,besurethattheprobetipofthe meterandtestlead(ortestclip)havebeendisconnectedfrommeasurementcircuitto avoidelectricshockhazard. 5.1.1Ifthesign‘ ’ appearsontheLCDdisplay,itindicatesthatthebatteryshouldbereplaced. 5.1.2Loosenthescrewfixingthebatterycoverandremoveit. 5.1.3Replacetheexhaustedbatterywithanewone. 5.1.4Putthebatterycoverasitsorigin. 5.2TESTLEADS(ORTESTCLIP)REPLACEMENT WARNING Fullincompliancewithsafetystandardscanbeguaranteedonlyifusedwithtestleads supplied.Ifnecessary,theymustbereplacedwiththesamemodelorsameelectric ratings.Electricratingsofthetestleads:600V10A. Youmustbereplacedthetestleadiftheleadisexposed. 6.ACCESSORIES ⑴ Test Lead:ElectricRatings600V10Aonepiece (ortestclip)totheother side. 4.8.6Youcangetreadingfrom LCDdisplay. WARNING RiskofElectrocution. Youcan’tinputthevoltagewhichishigherthan600VrmsAC,it’spossibletoshowhigher voltage,butitmaydamagetheinnercircuitorcauseelectricalshock. Payattentiontoavoidgettinganelectricshockwhenmeasuringvoltage. NOTE: -Atthemanualrangemode,whenonlythefigure‘OL ’ isdisplayed,itindicatesoverrangesituationand thehigherrangehastobeselected. -Atthelittlevoltagerange,themeterwillshowunsteadyreadingwhentestleadshaven’treachthecircuit, it’snormalbecausethemeterisverysensitivity.Whentestleadstouchthecircuit,youcangetthetrue reading. -Atthemanualrangemode,whenthevaluescaletobemeasuredisunknownbeforehand,selectthe rangeatthehighestpositionandsetdowngradually. -TransformtothemanualrangewhenusethemVrange. 4.9MEASURINGRESISTANCE 4.9.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.9.2InserttheblacktestleadortestclipintheCOMjack. 4.9.3Setthetransformswitchatthe(rangeposition. Autorangeormanualrangecanbe transformedbyputtingthe“RANGE”. 4.9.4Connecttheprobetipofthe metertoonesideofthetested circuitandprobetipofthetest lead(ortestclip)totheotherside. 4.9.5YoucangetreadingfromLCDdisplay. WARNING RiskofElectrocution. Whenmeasuringin-circuitresistance,besurethecircuitundertesthasallpower removedandthatallcapacitorshavebeendischargedfully. NOTE: -Atthemanualrangemode,whenonlythefigure‘OL ’ isdisplayed,itindicatesoverrangesituationand thehigherrangehastobeselected. -Formeasuringresistanceabove1MΩ,themetermaytakeafewsecondstogetstablereading. -Whentheinputisnotconnected,i.e.atopencircuit,thefigure‘OL ’ willbedisplayedfortheoverrange condition. 3.2.1DCVoltage RangeResolutionAccuracy 200mV0.1mV 2V0.001V 20V0.01V ±(0.7%ofrdg+2digits) 200V0.1V 600V1V -InputImpedance:10MΩ -OverloadProtection:200mVrange:250VDCorACrms, 2V-600Vranges:DC600VorAC600Vrms. -Max.InputVoltage:600VDC 3.2.2ACVoltage RangeResolutionAccuracy 200mV0.1mV 2V0.001V ±(0.8%ofrdg+3digits) 20V0.01V 200V0.1V 600V1V±(1.0%ofrdg+3digits) -InputImpedance:10MΩ -OverloadProtection:200mVrange:250VDCorACrms, 2V-600Vranges:DC600VorAC600Vrms. -FrequencyRange:40to400Hz -Response:Average,calibratedinrmsofsinewave. -Max.InputVoltage:600VrmsAC 3.2.3Resistance RangeResolutionAccuracy 200Ω0.1Ω ±(1.0%ofrdg+3digits) 2kΩ0.001kΩ 20kΩ0.01kΩ±(1.0%ofrdg+1digit) 200kΩ0.1kΩ 2MΩ0.001MΩ 20MΩ0.01MΩ ±(1.0%ofrdg+5digits) -OpenCircuitVoltage:0.25V -OverloadProtection:250VDCorrmsAC 3.2.4Continuity RangeFunction Built-inbuzzerwillsound,ifresistanceislowerthan50(. -Opencircuitvoltage:approx.0.5V -OverloadProtection:250VDCorrmsAC 3.2.5Diode 4.10TESTINGDIODE 4.10.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.10.2InserttheblacktestleadortestclipintheCOMjack. 4.10.3Setthetransformswitchatthe rangeposition. 4.10.4putdownthe"FUNC."transformedat test. 4.10.5Connecttheprobetipofthemetertotheanodeofthediode, theblacktestlead(ortestclip)tothecathodeofthediode. 4.10.6YoucangetreadingfromLCDdisplay. NOTE: -Themeterwillshowthe approximateforwardvoltage dropofthediode. -Ifthemeterandtheleadconnectionisreversed,onlyfigure‘OL ’ willbedisplayed. -Whentheinputisnotconnected,i.e.atopencircuit,thefigure‘OL ’ willbedisplayed. 4.11CONTINUITYTEST WARNING RiskofElectrocution. Whentestingthecircuitcontinuity,besurethatthepowerofthecircuithasbeenshut downandallcapacitorshavebeendischargedfully. 4.11.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.11.2InserttheblacktestleadortestclipintheCOMjack. 4.11.3Setthetransformswitch atthe rangeposition. 4.11.4Putdownthe"FUNC." transformedat continuitytest. 4.11.5Connecttheprobetipof themetertoonesideofthetestedcircuitandprobetipofthetestlead(ortestclip)totheotherside. 4.11.6Ifcontinuityexists(i.e.,resistancelessthanabout50Ω),built-inbuzzerwillsound. NOTE: -Iftheinputopencircuit(orthecircuitresistancemeasuredishigherthan200Ω),thenthefigure‘0L ’ will bedisplayed. 4.12ACVOLTAGEDETECT WARNING RiskofElectrocution. Whendetectingpayattentiontoavoidgettinganelectricshock. Beforeusingtocheckforvoltageinanoutlet,alwaystestthemeteronaknownlive circuittoverifythattheACvoltagedetectfunctionofthemeterisworkingproperly. keepfingersbehindtheprobebarrierwhilemeasuring. measuredisunknownbeforehand,selectthehighestrange. 4.6.2Whenmeasuring,atfirst,connecttothepublic(COM)testingline,thenconnecttheprobetipofthe metertothecircuitundertest. 4.6.3Ifthebatteryvoltageislessthan2.4V,displaywillshow“ ”,thebatteryshouldbechangedatthis time. 4.7DCVOLTAGEMEASURING WARNING RiskofElectrocution. Youcan’tinputthevoltagewhichishigherthan600VDC,it’spossibletoshowhigher voltage,butitmaydamagetheinnercircuitorcauseelectricalshock. Payattentiontoavoidgettinganelectricshockwhenmeasuringhighvoltage. 4.7.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.7.2InserttheblacktestleadortestclipintheCOMjack. 4.7.3Setthetransformswitchatthe V rangeposition. 4.7.4Pressthe"FUNC."Button totransformtoDCmeasurement. Autorangeandmanualrange canbetransformedby pressingthe“RANGE” button. 4.7.5Connecttheprobetipofthemeterandprobetipofthetestlead(ortestclip)acrossthepower sourceorbeloadedonthetwosidesundermeasurement. 4.7.6YoucangetareadingfromLCDdisplay.Thepolarityofthetestedterminalwhichthetipofthe meterconnectionwillbeindicated. NOTE: -Atthelittlevoltagerange,themeterwillshowunsteadyreadingwhentestleadshaven’treachthecircuit, it’snormalbecausethemeterisverysensitivity.Whenmetertouchthecircuit,youcangetthetrue reading. -Atthemanualrangemode,whenonlythefigure‘OL ’ isdisplayed,itindicatesoverrangesituationand thehigherrangehastobeselected. -Atthemanualrangemode,whenthevaluescaletobemeasuredisunknownbeforehand,selectthe rangetothehighestpositionandsetdowngradually. 4.8MEASURINGACVOLTAGE 4.8.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.8.2InserttheblacktestleadortestclipintheCOMjack. 4.8.3SetthetransformswitchattheVrangeposition. 4.8.4Autorangeandmanualrangecanbetransformedbyputtingthe“RANGE”. 4.8.5Connecttheprobetipofthemeter toonesideofthetestedcircuit andprobetipofthetestlead ... MS8211 ⑵ Test Clip:ElectricRatings600V10Aonepiece ⑶Battery:1.5V,AAAtwopieces ⑷InstructionManualonepiece RangeResolutionFunction 0.001VDisplay:readapproximateforwardvoltageof diode -ForwardDCCurrent:approx.1mA -ReversedDCVoltage:approx.1.5V -OverloadProtection:250VDCorrmsAC 3.2.6ACVoltageDetect RangeTEST Sensitivity Voltagesensitivity>50V,adjustcontinuously Frequency50Hz Distance<150mm(changealongwiththesensitivity) -Non-contactdetecting 4.OPERATINGINSTRUCTION 4.1 DATA HOLD Ifyouneeddataholdwhenmeasuring,youcanputon“DATA-H”button,itwillholdthereading;ifyouput thebuttonagain,dataholdisnotcontinue. 4.2MAXIMUMVALUEMEASURINGANDHOLD Attherangeofvoltage,youcanputon“MAX.H”button,itwillholdthemaximumvalue;ifyouputthe buttonagain,themaximumvaluewillnotbeheld. 4.3FUNCTIONTRANSFORM Putdownthe"FUNC."whenmeasuringthevoltage.MeterwillbetransformedbetweenDCandAC range.Put"FUNC."whenmeasuringtheresistance,diodeandcontinuity,meterwilltransformamong them. 4.4RANGETRANSFORM Theautorangeisusedwhenmeasuringthevoltageandresistance.Putdownthe"RANGE"ifthe manualrangeisneeded.Eachtimeyouputdown,rangewillgoupward;theminimumrangeis transformedif"RANGE"isputdownatthemaximumrange.Ifthe"RANGE"isputdownmorethantwo seconds,autorangeisusedagain. 4.5AUTOPOWEROFF Ifthere’snoanyoperationwithinfifteenminutesafterpowerison,meterwillautopoweroffwithfiveshort soundsandalongsoundinaminute. Afterautopoweroff,ifstirthetransformswitchorputdownanybuttonof“FUNC.”, “DATA-H”,”MAX.H”,”RANGE”,meterwillrecovertheworkingcondition. Ifpressesthe“FUNC.”whenpowerison,autopoweroffdisable. NOTE: AttheTESTrange(ACVdetecting),thereisnoautopowerofffunction 4.6PREPARATIONFORMEASUREMENT 4.6.1Setthetransformswitchtotherightrange.Atthemanualrange,whenthevaluescaletobe 4.12.1Rotatetheprobesocketanti-clockwisetospintheprobeintothemeter. 4.12.2Setthetransformswitchatthe Vrangeposition. 4.12.3Besurethatthedisplayisnot shown“ ”,otherwise,the batteryshouldbereplaced. 4.12.4Setthetransformswitchto theTESTrange.ThenthegreenLEDoftheLEDIndicatorisbright. 4.12.5Rotatethesensitivityadjustingknobinthemiddleofthetransformswitchanti-clockwise,setthe meter tothehighestdetectingsensitivityinordertoenlargethedetectingrange. 4.12.6Puttheprobesocketclosetotheleadorthepowersocket,IfACelectricalvoltageispresent,the redLEDIndicatorwhichinfrontofthemeterwillflashandtheaudiblewarningwillsound. 4.12.7Intheplaceswithmanyleadsandjacks,rotatethesensitivityadjustingknobinthemiddleofthe transformswitchclockwise,setthemetertothelowerdetectingsensitivityinordertoconfirmwhichone iselectriferous. NOTE: -WhenusingACVdetectingfunction,alwayssetthemetertothehighestsensitivity. -Inthisrange,eventhoughthereisnoanysoundandlightindication,themeterwillstillconsume electricity. -Thereisnoautopowerofffunctioninthisrange. -AlwayssetthepowerswitchtotheOFFpositionwhenthemeterisnotinuse. 5.MAINTENANCE 5.1BATTERYREPLACEMENT WARNING Beforeattemptingtoopenthebatterycoverofthemeter,besurethattheprobetipofthe meterandtestlead(ortestclip)havebeendisconnectedfrommeasurementcircuitto avoidelectricshockhazard. 5.1.1Ifthesign‘ ’ appearsontheLCDdisplay,itindicatesthatthebatteryshouldbereplaced. 5.1.2Loosenthescrewfixingthebatterycoverandremoveit. 5.1.3Replacetheexhaustedbatterywithanewone. 5.1.4Putthebatterycoverasitsorigin. 5.2TESTLEADS(ORTESTCLIP)REPLACEMENT WARNING Fullincompliancewithsafetystandardscanbeguaranteedonlyifusedwithtestleads supplied.Ifnecessary,theymustbereplacedwiththesamemodelorsameelectric ratings.Electricratingsofthetestleads:600V10A. Youmustbereplacedthetestleadiftheleadisexposed. 6.ACCESSORIES ⑴ Test Lead:ElectricRatings600V10Aonepiece (ortestclip)totheother side. 4.8.6Youcangetreadingfrom LCDdisplay. WARNING RiskofElectrocution. Youcan’tinputthevoltagewhichishigherthan600VrmsAC,it’spossibletoshowhigher voltage,butitmaydamagetheinnercircuitorcauseelectricalshock. Payattentiontoavoidgettinganelectricshockwhenmeasuringvoltage. NOTE: -Atthemanualrangemode,whenonlythefigure‘OL ’ isdisplayed,itindicatesoverrangesituationand thehigherrangehastobeselected. -Atthelittlevoltagerange,themeterwillshowunsteadyreadingwhentestleadshaven’treachthecircuit, it’snormalbecausethemeterisverysensitivity.Whentestleadstouchthecircuit,youcangetthetrue reading. -Atthemanualrangemode,whenthevaluescaletobemeasuredisunknownbeforehand,selectthe rangeatthehighestpositionandsetdowngradually. -TransformtothemanualrangewhenusethemVrange. 4.9MEASURINGRESISTANCE 4.9.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.9.2InserttheblacktestleadortestclipintheCOMjack. 4.9.3Setthetransformswitchatthe(rangeposition. Autorangeormanualrangecanbe transformedbyputtingthe“RANGE”. 4.9.4Connecttheprobetipofthe metertoonesideofthetested circuitandprobetipofthetest lead(ortestclip)totheotherside. 4.9.5YoucangetreadingfromLCDdisplay. WARNING RiskofElectrocution. Whenmeasuringin-circuitresistance,besurethecircuitundertesthasallpower removedandthatallcapacitorshavebeendischargedfully. NOTE: -Atthemanualrangemode,whenonlythefigure‘OL ’ isdisplayed,itindicatesoverrangesituationand thehigherrangehastobeselected. -Formeasuringresistanceabove1MΩ,themetermaytakeafewsecondstogetstablereading. -Whentheinputisnotconnected,i.e.atopencircuit,thefigure‘OL ’ willbedisplayedfortheoverrange condition. 3.2.1DCVoltage RangeResolutionAccuracy 200mV0.1mV 2V0.001V 20V0.01V ±(0.7%ofrdg+2digits) 200V0.1V 600V1V -InputImpedance:10MΩ -OverloadProtection:200mVrange:250VDCorACrms, 2V-600Vranges:DC600VorAC600Vrms. -Max.InputVoltage:600VDC 3.2.2ACVoltage RangeResolutionAccuracy 200mV0.1mV 2V0.001V ±(0.8%ofrdg+3digits) 20V0.01V 200V0.1V 600V1V±(1.0%ofrdg+3digits) -InputImpedance:10MΩ -OverloadProtection:200mVrange:250VDCorACrms, 2V-600Vranges:DC600VorAC600Vrms. -FrequencyRange:40to400Hz -Response:Average,calibratedinrmsofsinewave. -Max.InputVoltage:600VrmsAC 3.2.3Resistance RangeResolutionAccuracy 200Ω0.1Ω ±(1.0%ofrdg+3digits) 2kΩ0.001kΩ 20kΩ0.01kΩ±(1.0%ofrdg+1digit) 200kΩ0.1kΩ 2MΩ0.001MΩ 20MΩ0.01MΩ ±(1.0%ofrdg+5digits) -OpenCircuitVoltage:0.25V -OverloadProtection:250VDCorrmsAC 3.2.4Continuity RangeFunction Built-inbuzzerwillsound,ifresistanceislowerthan50(. -Opencircuitvoltage:approx.0.5V -OverloadProtection:250VDCorrmsAC 3.2.5Diode 4.10TESTINGDIODE 4.10.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.10.2InserttheblacktestleadortestclipintheCOMjack. 4.10.3Setthetransformswitchatthe rangeposition. 4.10.4putdownthe"FUNC."transformedat test. 4.10.5Connecttheprobetipofthemetertotheanodeofthediode, theblacktestlead(ortestclip)tothecathodeofthediode. 4.10.6YoucangetreadingfromLCDdisplay. NOTE: -Themeterwillshowthe approximateforwardvoltage dropofthediode. -Ifthemeterandtheleadconnectionisreversed,onlyfigure‘OL ’ willbedisplayed. -Whentheinputisnotconnected,i.e.atopencircuit,thefigure‘OL ’ willbedisplayed. 4.11CONTINUITYTEST WARNING RiskofElectrocution. Whentestingthecircuitcontinuity,besurethatthepowerofthecircuithasbeenshut downandallcapacitorshavebeendischargedfully. 4.11.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.11.2InserttheblacktestleadortestclipintheCOMjack. 4.11.3Setthetransformswitch atthe rangeposition. 4.11.4Putdownthe"FUNC." transformedat continuitytest. 4.11.5Connecttheprobetipof themetertoonesideofthetestedcircuitandprobetipofthetestlead(ortestclip)totheotherside. 4.11.6Ifcontinuityexists(i.e.,resistancelessthanabout50Ω),built-inbuzzerwillsound. NOTE: -Iftheinputopencircuit(orthecircuitresistancemeasuredishigherthan200Ω),thenthefigure‘0L ’ will bedisplayed. 4.12ACVOLTAGEDETECT WARNING RiskofElectrocution. Whendetectingpayattentiontoavoidgettinganelectricshock. Beforeusingtocheckforvoltageinanoutlet,alwaystestthemeteronaknownlive circuittoverifythattheACvoltagedetectfunctionofthemeterisworkingproperly. keepfingersbehindtheprobebarrierwhilemeasuring. measuredisunknownbeforehand,selectthehighestrange. 4.6.2Whenmeasuring,atfirst,connecttothepublic(COM)testingline,thenconnecttheprobetipofthe metertothecircuitundertest. 4.6.3Ifthebatteryvoltageislessthan2.4V,displaywillshow“ ”,thebatteryshouldbechangedatthis time. 4.7DCVOLTAGEMEASURING WARNING RiskofElectrocution. Youcan’tinputthevoltagewhichishigherthan600VDC,it’spossibletoshowhigher voltage,butitmaydamagetheinnercircuitorcauseelectricalshock. Payattentiontoavoidgettinganelectricshockwhenmeasuringhighvoltage. 4.7.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.7.2InserttheblacktestleadortestclipintheCOMjack. 4.7.3Setthetransformswitchatthe V rangeposition. 4.7.4Pressthe"FUNC."Button totransformtoDCmeasurement. Autorangeandmanualrange canbetransformedby pressingthe“RANGE” button. 4.7.5Connecttheprobetipofthemeterandprobetipofthetestlead(ortestclip)acrossthepower sourceorbeloadedonthetwosidesundermeasurement. 4.7.6YoucangetareadingfromLCDdisplay.Thepolarityofthetestedterminalwhichthetipofthe meterconnectionwillbeindicated. NOTE: -Atthelittlevoltagerange,themeterwillshowunsteadyreadingwhentestleadshaven’treachthecircuit, it’snormalbecausethemeterisverysensitivity.Whenmetertouchthecircuit,youcangetthetrue reading. -Atthemanualrangemode,whenonlythefigure‘OL ’ isdisplayed,itindicatesoverrangesituationand thehigherrangehastobeselected. -Atthemanualrangemode,whenthevaluescaletobemeasuredisunknownbeforehand,selectthe rangetothehighestpositionandsetdowngradually. 4.8MEASURINGACVOLTAGE 4.8.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.8.2InserttheblacktestleadortestclipintheCOMjack. 4.8.3SetthetransformswitchattheVrangeposition. 4.8.4Autorangeandmanualrangecanbetransformedbyputtingthe“RANGE”. 4.8.5Connecttheprobetipofthemeter toonesideofthetestedcircuit andprobetipofthetestlead ... MS8211 ⑵ Test Clip:ElectricRatings600V10Aonepiece ⑶Battery:1.5V,AAAtwopieces ⑷InstructionManualonepiece RangeResolutionFunction 0.001VDisplay:readapproximateforwardvoltageof diode -ForwardDCCurrent:approx.1mA -ReversedDCVoltage:approx.1.5V -OverloadProtection:250VDCorrmsAC 3.2.6ACVoltageDetect RangeTEST Sensitivity Voltagesensitivity>50V,adjustcontinuously Frequency50Hz Distance<150mm(changealongwiththesensitivity) -Non-contactdetecting 4.OPERATINGINSTRUCTION 4.1 DATA HOLD Ifyouneeddataholdwhenmeasuring,youcanputon“DATA-H”button,itwillholdthereading;ifyouput thebuttonagain,dataholdisnotcontinue. 4.2MAXIMUMVALUEMEASURINGANDHOLD Attherangeofvoltage,youcanputon“MAX.H”button,itwillholdthemaximumvalue;ifyouputthe buttonagain,themaximumvaluewillnotbeheld. 4.3FUNCTIONTRANSFORM Putdownthe"FUNC."whenmeasuringthevoltage.MeterwillbetransformedbetweenDCandAC range.Put"FUNC."whenmeasuringtheresistance,diodeandcontinuity,meterwilltransformamong them. 4.4RANGETRANSFORM Theautorangeisusedwhenmeasuringthevoltageandresistance.Putdownthe"RANGE"ifthe manualrangeisneeded.Eachtimeyouputdown,rangewillgoupward;theminimumrangeis transformedif"RANGE"isputdownatthemaximumrange.Ifthe"RANGE"isputdownmorethantwo seconds,autorangeisusedagain. 4.5AUTOPOWEROFF Ifthere’snoanyoperationwithinfifteenminutesafterpowerison,meterwillautopoweroffwithfiveshort soundsandalongsoundinaminute. Afterautopoweroff,ifstirthetransformswitchorputdownanybuttonof“FUNC.”, “DATA-H”,”MAX.H”,”RANGE”,meterwillrecovertheworkingcondition. Ifpressesthe“FUNC.”whenpowerison,autopoweroffdisable. NOTE: AttheTESTrange(ACVdetecting),thereisnoautopowerofffunction 4.6PREPARATIONFORMEASUREMENT 4.6.1Setthetransformswitchtotherightrange.Atthemanualrange,whenthevaluescaletobe 4.12.1Rotatetheprobesocketanti-clockwisetospintheprobeintothemeter. 4.12.2Setthetransformswitchatthe Vrangeposition. 4.12.3Besurethatthedisplayisnot shown“ ”,otherwise,the batteryshouldbereplaced. 4.12.4Setthetransformswitchto theTESTrange.ThenthegreenLEDoftheLEDIndicatorisbright. 4.12.5Rotatethesensitivityadjustingknobinthemiddleofthetransformswitchanti-clockwise,setthe meter tothehighestdetectingsensitivityinordertoenlargethedetectingrange. 4.12.6Puttheprobesocketclosetotheleadorthepowersocket,IfACelectricalvoltageispresent,the redLEDIndicatorwhichinfrontofthemeterwillflashandtheaudiblewarningwillsound. 4.12.7Intheplaceswithmanyleadsandjacks,rotatethesensitivityadjustingknobinthemiddleofthe transformswitchclockwise,setthemetertothelowerdetectingsensitivityinordertoconfirmwhichone iselectriferous. NOTE: -WhenusingACVdetectingfunction,alwayssetthemetertothehighestsensitivity. -Inthisrange,eventhoughthereisnoanysoundandlightindication,themeterwillstillconsume electricity. -Thereisnoautopowerofffunctioninthisrange. -AlwayssetthepowerswitchtotheOFFpositionwhenthemeterisnotinuse. 5.MAINTENANCE 5.1BATTERYREPLACEMENT WARNING Beforeattemptingtoopenthebatterycoverofthemeter,besurethattheprobetipofthe meterandtestlead(ortestclip)havebeendisconnectedfrommeasurementcircuitto avoidelectricshockhazard. 5.1.1Ifthesign‘ ’ appearsontheLCDdisplay,itindicatesthatthebatteryshouldbereplaced. 5.1.2Loosenthescrewfixingthebatterycoverandremoveit. 5.1.3Replacetheexhaustedbatterywithanewone. 5.1.4Putthebatterycoverasitsorigin. 5.2TESTLEADS(ORTESTCLIP)REPLACEMENT WARNING Fullincompliancewithsafetystandardscanbeguaranteedonlyifusedwithtestleads supplied.Ifnecessary,theymustbereplacedwiththesamemodelorsameelectric ratings.Electricratingsofthetestleads:600V10A. Youmustbereplacedthetestleadiftheleadisexposed. 6.ACCESSORIES ⑴ Test Lead:ElectricRatings600V10Aonepiece (ortestclip)totheother side. 4.8.6Youcangetreadingfrom LCDdisplay. WARNING RiskofElectrocution. Youcan’tinputthevoltagewhichishigherthan600VrmsAC,it’spossibletoshowhigher voltage,butitmaydamagetheinnercircuitorcauseelectricalshock. Payattentiontoavoidgettinganelectricshockwhenmeasuringvoltage. NOTE: -Atthemanualrangemode,whenonlythefigure‘OL ’ isdisplayed,itindicatesoverrangesituationand thehigherrangehastobeselected. -Atthelittlevoltagerange,themeterwillshowunsteadyreadingwhentestleadshaven’treachthecircuit, it’snormalbecausethemeterisverysensitivity.Whentestleadstouchthecircuit,youcangetthetrue reading. -Atthemanualrangemode,whenthevaluescaletobemeasuredisunknownbeforehand,selectthe rangeatthehighestpositionandsetdowngradually. -TransformtothemanualrangewhenusethemVrange. 4.9MEASURINGRESISTANCE 4.9.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.9.2InserttheblacktestleadortestclipintheCOMjack. 4.9.3Setthetransformswitchatthe(rangeposition. Autorangeormanualrangecanbe transformedbyputtingthe“RANGE”. 4.9.4Connecttheprobetipofthe metertoonesideofthetested circuitandprobetipofthetest lead(ortestclip)totheotherside. 4.9.5YoucangetreadingfromLCDdisplay. WARNING RiskofElectrocution. Whenmeasuringin-circuitresistance,besurethecircuitundertesthasallpower removedandthatallcapacitorshavebeendischargedfully. NOTE: -Atthemanualrangemode,whenonlythefigure‘OL ’ isdisplayed,itindicatesoverrangesituationand thehigherrangehastobeselected. -Formeasuringresistanceabove1MΩ,themetermaytakeafewsecondstogetstablereading. -Whentheinputisnotconnected,i.e.atopencircuit,thefigure‘OL ’ willbedisplayedfortheoverrange condition. 3.2.1DCVoltage RangeResolutionAccuracy 200mV0.1mV 2V0.001V 20V0.01V ±(0.7%ofrdg+2digits) 200V0.1V 600V1V -InputImpedance:10MΩ -OverloadProtection:200mVrange:250VDCorACrms, 2V-600Vranges:DC600VorAC600Vrms. -Max.InputVoltage:600VDC 3.2.2ACVoltage RangeResolutionAccuracy 200mV0.1mV 2V0.001V ±(0.8%ofrdg+3digits) 20V0.01V 200V0.1V 600V1V±(1.0%ofrdg+3digits) -InputImpedance:10MΩ -OverloadProtection:200mVrange:250VDCorACrms, 2V-600Vranges:DC600VorAC600Vrms. -FrequencyRange:40to400Hz -Response:Average,calibratedinrmsofsinewave. -Max.InputVoltage:600VrmsAC 3.2.3Resistance RangeResolutionAccuracy 200Ω0.1Ω ±(1.0%ofrdg+3digits) 2kΩ0.001kΩ 20kΩ0.01kΩ±(1.0%ofrdg+1digit) 200kΩ0.1kΩ 2MΩ0.001MΩ 20MΩ0.01MΩ ±(1.0%ofrdg+5digits) -OpenCircuitVoltage:0.25V -OverloadProtection:250VDCorrmsAC 3.2.4Continuity RangeFunction Built-inbuzzerwillsound,ifresistanceislowerthan50(. -Opencircuitvoltage:approx.0.5V -OverloadProtection:250VDCorrmsAC 3.2.5Diode 4.10TESTINGDIODE 4.10.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.10.2InserttheblacktestleadortestclipintheCOMjack. 4.10.3Setthetransformswitchatthe rangeposition. 4.10.4putdownthe"FUNC."transformedat test. 4.10.5Connecttheprobetipofthemetertotheanodeofthediode, theblacktestlead(ortestclip)tothecathodeofthediode. 4.10.6YoucangetreadingfromLCDdisplay. NOTE: -Themeterwillshowthe approximateforwardvoltage dropofthediode. -Ifthemeterandtheleadconnectionisreversed,onlyfigure‘OL ’ willbedisplayed. -Whentheinputisnotconnected,i.e.atopencircuit,thefigure‘OL ’ willbedisplayed. 4.11CONTINUITYTEST WARNING RiskofElectrocution. Whentestingthecircuitcontinuity,besurethatthepowerofthecircuithasbeenshut downandallcapacitorshavebeendischargedfully. 4.11.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.11.2InserttheblacktestleadortestclipintheCOMjack. 4.11.3Setthetransformswitch atthe rangeposition. 4.11.4Putdownthe"FUNC." transformedat continuitytest. 4.11.5Connecttheprobetipof themetertoonesideofthetestedcircuitandprobetipofthetestlead(ortestclip)totheotherside. 4.11.6Ifcontinuityexists(i.e.,resistancelessthanabout50Ω),built-inbuzzerwillsound. NOTE: -Iftheinputopencircuit(orthecircuitresistancemeasuredishigherthan200Ω),thenthefigure‘0L ’ will bedisplayed. 4.12ACVOLTAGEDETECT WARNING RiskofElectrocution. Whendetectingpayattentiontoavoidgettinganelectricshock. Beforeusingtocheckforvoltageinanoutlet,alwaystestthemeteronaknownlive circuittoverifythattheACvoltagedetectfunctionofthemeterisworkingproperly. keepfingersbehindtheprobebarrierwhilemeasuring. measuredisunknownbeforehand,selectthehighestrange. 4.6.2Whenmeasuring,atfirst,connecttothepublic(COM)testingline,thenconnecttheprobetipofthe metertothecircuitundertest. 4.6.3Ifthebatteryvoltageislessthan2.4V,displaywillshow“ ”,thebatteryshouldbechangedatthis time. 4.7DCVOLTAGEMEASURING WARNING RiskofElectrocution. Youcan’tinputthevoltagewhichishigherthan600VDC,it’spossibletoshowhigher voltage,butitmaydamagetheinnercircuitorcauseelectricalshock. Payattentiontoavoidgettinganelectricshockwhenmeasuringhighvoltage. 4.7.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.7.2InserttheblacktestleadortestclipintheCOMjack. 4.7.3Setthetransformswitchatthe V rangeposition. 4.7.4Pressthe"FUNC."Button totransformtoDCmeasurement. Autorangeandmanualrange canbetransformedby pressingthe“RANGE” button. 4.7.5Connecttheprobetipofthemeterandprobetipofthetestlead(ortestclip)acrossthepower sourceorbeloadedonthetwosidesundermeasurement. 4.7.6YoucangetareadingfromLCDdisplay.Thepolarityofthetestedterminalwhichthetipofthe meterconnectionwillbeindicated. NOTE: -Atthelittlevoltagerange,themeterwillshowunsteadyreadingwhentestleadshaven’treachthecircuit, it’snormalbecausethemeterisverysensitivity.Whenmetertouchthecircuit,youcangetthetrue reading. -Atthemanualrangemode,whenonlythefigure‘OL ’ isdisplayed,itindicatesoverrangesituationand thehigherrangehastobeselected. -Atthemanualrangemode,whenthevaluescaletobemeasuredisunknownbeforehand,selectthe rangetothehighestpositionandsetdowngradually. 4.8MEASURINGACVOLTAGE 4.8.1Rotatetheprobesocketclockwisetospinouttheprobefromthemeter. 4.8.2InserttheblacktestleadortestclipintheCOMjack. 4.8.3SetthetransformswitchattheVrangeposition. 4.8.4Autorangeandmanualrangecanbetransformedbyputtingthe“RANGE”. 4.8.5Connecttheprobetipofthemeter toonesideofthetestedcircuit andprobetipofthetestlead ...

Ngày tải lên: 05/03/2013, 13:43

11 382 0
User manual

User manual

Ngày tải lên: 18/06/2013, 16:21

240 506 0
High-Speed Data Interface Modules

High-Speed Data Interface Modules

... interfaces • Interoperable with standard router platforms • High- speed serial connectivity up to 4.608 Mbps • Simple Installation and configuration High- Speed Data Interface Modules ... n x 56/64 kbps rates up to a maximum of 4.608 Mbps. The Campus-RS SDI can be used to provide high- speed connectivity for industry-standard bridge/router type devices within a private network ... copper infrastructure. The SDI modules provide fractional bandwidth on the integrated local data port at speeds ranging from 56 kbps to 4.608 Mbps and provide a variety of data clocking options including...

Ngày tải lên: 18/10/2013, 19:15

2 195 0
BUILDING HIGH-SPEED DATA OVER VOICE NETWORKS

BUILDING HIGH-SPEED DATA OVER VOICE NETWORKS

... create a high- speed data network using its existing voice infrastructure in more than 300 metropolitan and rural markets. Without this service upgrade, the carrier stands to lose significant high- value ... customers to new providers of high- speed services in many of its key markets. STRATEGY Design and deploy a DSLAM solution rapidly and efficiently while maintaining the highest standards of quality ... maintaining the highest possible quality standards, which dramatically improved the carrier’s competitive position and ability to capture new revenue from the delivery of value-added high- speed services. CASE...

Ngày tải lên: 27/10/2013, 00:15

4 262 0
Tài liệu High Speed Precision Motion Control doc

Tài liệu High Speed Precision Motion Control doc

... advanced control algorithms for mechatronic systems. Some past re- lated projects include high speed and high precision control of head actuators of HDDs, semiconductor manufacturing systems (a ... business Boca Raton London New York Edited by Takashi Yamaguchi Mitsuo Hirata Chee Khiang Pang High- Speed Precision Motion Control ix 7.4 Overview of the HDD Benchmark Problem Version 3 . . . ... professors researching HDD servo control and HDD company engineers for their efforts in evolving high- speed precision motion control technology. We have learned a lot through various technical discussions...

Ngày tải lên: 18/02/2014, 22:20

315 280 0
Tài liệu MSI Afterburner User Manual ppt

Tài liệu MSI Afterburner User Manual ppt

... Enable user definedsoftwareautomaticfancontrol:Aftercheckingit,theFan speed curvewillbeshown, anduserscancustomizethefan speed settingsbyaddingandadjustingnewfan speed/ temperaturenode,just astheexamplebelow:      → ... 15 softwarewillperiodicallydetectGPUtemperatureandsetsnewfan speed accordingtothefan speed curve, definedinthe<fan>tabinadvancedproperties. Hint1:Youcanstilluse  toswitchbetweenautomaticand manual fan speed controlmodeseven ifthe user definedautomaticsoftwarefancontrolmodeisenabled.   4‐8.   ... Hint2:ShaderclockadjustmentisavailableonlyonNVIDIAGeForce8orhigherseriesgraphicscards.ATI 25  6‐6. User Interface                          User interfacehelpsystemproperties  Show user interfacetooltips:Showtooltipswhenusersputthecursoronthefeatureitems.  User interfaceskinningproperties ...

Ngày tải lên: 19/02/2014, 18:20

26 474 0
Tài liệu ECONOMIC, ENVIRONMENTAL AND ENERGY ASSESSMENT OF THE TURIN-LYON HIGH-SPEED RAIL pdf

Tài liệu ECONOMIC, ENVIRONMENTAL AND ENERGY ASSESSMENT OF THE TURIN-LYON HIGH-SPEED RAIL pdf

... that the High- Speed Train Turin-Lyon is not a priority for Italy and France, and its construction should be immediately stopped. INTRODUCTION The construction of the High Speed Railway ... Citizenship, a Case Study. The Controversy of High- Speed Rail in the Susa Valley; Paolo Beria, Raffaele Grimaldi, 2011. An Early Evaluation of Italian High Speed Projects. Tema, 4(3): 15-28. http://www.tema.unina.it. ... at a speed of 150 kilometers per hour and have to stop and spend most of their time in a transit station when they arrive in Italy. Concerning passengers, it makes sense to talk of High Speed...

Ngày tải lên: 20/02/2014, 19:20

8 525 0
Tài liệu Báo cáo khoa học: "A HARDWARE ALGORITHM FOR HIGH SPEED MORPHEME EXTRACTION AND ITS IMPLEMENTATION" pptx

Tài liệu Báo cáo khoa học: "A HARDWARE ALGORITHM FOR HIGH SPEED MORPHEME EXTRACTION AND ITS IMPLEMENTATION" pptx

... for high speed morpheme extraction, and also de- scribes its implementation on a specific machine. This machine, MEX.I, is designed as the first step 313 A HARDWARE ALGORITHM FOR HIGH SPEED ... accelerators, a hardware approach to the parsing speed- up (Fukushima, 1989b) -(Fukushima, 1990a). This paper describes a new hardware algorithm for high speed morpheme ex- traction and its implementation ... is suitable for VLSI implementation. Ac- tually, its VLSI implementation is in progress. A high speed morpheme extraction VLSI will im- prove the performance of such text processing ap- plications...

Ngày tải lên: 21/02/2014, 20:20

8 504 0
Control Keyboard User Manual pot

Control Keyboard User Manual pot

... enter camera setup menu  Camera Operation Setup Enter camera function setup menu to setup the camera function (Please refer to “7.3 Camera Menu Setup Mode” and for more detail refer to speed dome ... Steps: 1 Select the desired speed dome camera (please refer to 6.1.1 SELECT and SWITCH DEVICE). 2 Use the joystick (on the control keyboard) and move the speed dome camera to the desired preset ... in order (1~32). It memorizes the PTZ movement and camera focus from the starting point at the same interval (Please refer to speed dome user manual for group setup).  Start Pattern Run Under...

Ngày tải lên: 05/03/2014, 11:20

19 499 0
Báo cáo khoa học: "Randomized Algorithms and NLP: Using Locality Sensitive Hash Function for High Speed Noun Clustering" pdf

Báo cáo khoa học: "Randomized Algorithms and NLP: Using Locality Sensitive Hash Function for High Speed Noun Clustering" pdf

... to be quite difficult. However, we are mainly concerned with evaluating the quality and speed of our high speed randomized algorithm. The web cor- pus is used to show that our framework is web- scalable, ... Computational Linguistics Randomized Algorithms and NLP: Using Locality Sensitive Hash Function for High Speed Noun Clustering Deepak Ravichandran, Patrick Pantel, and Eduard Hovy Information Sciences ... is widely used in NLP for various applications such as clustering. In this paper, we perform high speed similarity list creation for nouns collected from a huge web corpus. We linearize this...

Ngày tải lên: 08/03/2014, 04:22

8 393 0
RYK-9244_6_8_ User Manual pptx

RYK-9244_6_8_ User Manual pptx

... Rewind Speed : 2x, 4x, 8x, 16x, 32x, 64x Press「 / 」button to Fast Forward Speed : 2x, 4x, 8x, 16x, 32x, 64x / Press「PLAY」/ 「 」button to Play/ Pause Playback 「 / SLOW」slow playback Speed : ... to set up SMTP Server name. Port Default is 80. Maximum number of port is 65535. User Name Enter to set up User Name. Password Enter to set up Password. Sender E-mail Enter to set up e-mail ... Motion Setup 16 4.6.1 Permission Setup The Account Setup is set to provide individual user (maximum of 4 users) role-based permissions, including access to Setup menu, Network operation, PTZ...

Ngày tải lên: 14/03/2014, 10:20

54 541 0
WOMEN’S HEALTH USER MANUAL docx

WOMEN’S HEALTH USER MANUAL docx

... 1.0 September 1998 User Manual Preface iv Women’s Health V. 1.0 September 1998 User Manual Package Operation 3.2 Women’s Health V. 1.0 September 1998 User Manual Revision ... V. 1.0 3.1 User Manual Revision History ii Women’s Health V. 1.0 September 1998 User Manual File Maintenance Menu September 1998 Women’s Health V. 1.0 2.27 User Manual Implementation ... follow-up. 1.2 Women’s Health V. 1.0 September 1998 User Manual Introduction 2 Women’s Health V. 1.0 September 1998 User Manual Chapter 3 Package Operation Having completed...

Ngày tải lên: 14/03/2014, 12:20

164 2,3K 0
User manual GT-I9300 ppt

User manual GT-I9300 ppt

... QWERTY keypad in widescreen. Select the virtual keys as necessary to enter your text. GT-I9300 user manual Assembling 20 Charge with a USB cable › Before charging, ensure that your computer is ... is an infringement of copyright laws. Samsung is not liable for such copyright infringement by users. You may incur additional charges for data services, such as ● messaging, uploading and ... an appropriate data tariff plan. For details, contact your service provider. Please keep this manual for future reference. ● 41 Getting started Select a wallpaper for the Home screen › In...

Ngày tải lên: 15/03/2014, 11:20

183 629 0
w