... normal supplies of feed or water are interrupted in emergency situations. Recommended codeofpracticefor the care and Recommended codeofpracticefor the care and handling of poultry from ... Facilities forand handling of loose-housed poultry5.2.1 Proper building design and accessibility to transport vehicles greatly improves the humanehandling of loose-housed poultry. Owners and operators ... and watering space, an adequate and predictable supply of feed and water, and an adequate number of nest boxes and roosts. 142.5 Supervision and protection of chickens2.5.1 Chicken flocks...
... use of steelwork in building — Part 4: Codeofpracticefor design of composite slabs with profiled steel sheeting.BS 5950-5, Structural use of steelwork in building — Part 5: Codeofpractice ... carbon steel bars for the reinforcement of concrete.BS 4482, Specification for cold reduced steel wire for the reinforcement of concrete.BS 4483, Steel fabric for the reinforcement of concrete.BS ... 5: Codeofpracticefor design of cold formed thin gauge sections.BS 5950-6, Structural use of steelwork in building — Part 6: Codeofpracticefor design of light gauge profiled steel sheeting.BS...
... recommendations for the use of their multiples andof certain other unitsBS 6399 : Loading for buildingsBS 6399 : Part 2 : 1995 Codeofpracticefor wind loadsBS 6399 : Part 3 : 1988 Codeofpracticefor ... maintenance of, or thereplacement of parts of, existing buildings and structures where there is no change of use.1.2 This codeofpractice does not cover:a) loads on road and rail bridges, as these ... Definitions For the purposes of this codeofpractice thefollowing definitions apply.3.1 dead loadThe load due to the weight of all walls, permanentpartitions, floors, roofs, finishes and all...
... Information Labeling and secure handling of classified information is a key requirement for information sharing arrangements. Physical labels are a common form of labeling. However, some information assets, ... guidelines This codeofpractice may be regarded as a starting point for developing organization specific guidelines. Not all of the controls and guidance in this codeofpractice may be applicable. ... eShop.bsi-global.com e) responsibilities of the organization for the handling of personal information, including personal information created as a result of, or in the course of, employment with the organization...
... conditions and system configurations, can be referenced to codes, guidelines and practices of international standards (such as ASHRAE, CIBSE) or established local standards or trade good practices, for ... forced fan ventilation. ‘Director’ means the Director of Electrical and Mechanical Services. CodeofPracticefor Building Energy Audit EAC_2012 9 of 11 EMSD cost benefit analyses, and ... date of issue of Energy Audit Form, - name and address of building (English and Chinese), - name and Registration No. of Registered Energy Assessor who has carried out the energy audit, and...
... handling;· Manual handling; and · Vehicle and equipment safety. ENVIRONMENTAL CODEOFPRACTICEFOR POULTRY FARMS IN WESTERN AUSTRALIA33PART 4 OTHER CONSIDERATIONS ENVIRONMENTAL CODEOFPRACTICE ... Welfare of Animals: Land Transport of Poultry, available from the Internet site<www.publish.csiro.au> ;and the Department of Local Government and Regional Development’s Code ofPracticefor ... for transportation to the central grading floor in Palmyra for grading and retaildistribution. ENVIRONMENTAL CODEOFPRACTICEFOR POULTRY FARMS IN WESTERN AUSTRALIAiv ENVIRONMENTAL CODE OF...
... information is a shorthand way of determining how this information is to be handled and protected. 7.2.2 Information labeling and handling Control An appropriate set of procedures for information ... techniques — Codeof practice for information security management 1 Scope This International Standard establishes guidelines and general principles for initiating, implementing, maintaining, and ... contracts and other factors as required. In serious cases of misconduct the process should allow for instant removal of duties, access rights and privileges, andfor immediate escorting out of the...
... materials and workmanship: coldformed sections and sheeting.BS 6399-1, Loading for buildings Ð Codeof practice for dead and imposed loads.BS 6399-2, Loading for buildings Ð Codeof practice for ... practicefor protective coating of iron and steel structures against corrosion1).BS 5502-22, Buildings and structures for agriculture Ð Codeofpracticefor design,construction and loading.BS ... properties of fasteners ÐBolts, screws and studs.CP3 Codeof basic data for the design of buildings:Chapter V: Part 2: Wind loads.1.4 Terms and definitions For the purposes of this part of BS...
... 3.4 and 3.5 of BS 8110-1:1985 or Tables 5.1 and 5.2 of BS 8110-2:1985.Figure 4 — Typical profiles BRITISH STANDARDBS 5950-4:1994Structural use of steelwork in building —Part 4: Codeofpractice ... loadDpOverall depth of profiled steel sheetsDsOverall depth of composite slabdsEffective depth of slab to centroid of profiled steel sheetsE Modulus of elasticity of profiled steel sheetsFaEnd ... factor of 1.25 is a partial safety factor for resistances gm, selected on the basis of the behaviour and mode of failure of the slab.The empirical parameters mr and kr in this formula...
... Rt,0.5 and Rmshould normally be taken as specified in the relevant product standard for the steel sheet or strip and used for the formed sections. For information, the resulting values of Ys and ... Properties of materials and section properties3.1 Range of thicknessesThe provisions of this Part of BS 5950 apply primarily to profiled steel sheet with a net thickness of steel basemetal of not ... stateDpOverall depth of the profileDwSloping distance between the intersection points of a web and flanges (see figure 4)d Diameter of a fastenerdpDiameter of a perforationdwDiameter of a washerE...
... 3.1: Codeofpracticefor design of simple and continuous composite beams;— Section 3.21): Codeofpracticefor design of composite columns and frames;— Part 4: Codeofpracticefor design of ... Specification for materials and workmanship: cold formed sections;— Part 8: Codeofpracticefor fire resistant design;— Part 91): Codeofpracticefor stressed skin design.This Part of BS5950 ... of floors with profiled steel sheeting;— Part 5: Codeofpracticefor design in cold formed sections;— Part 61): Codeofpracticefor design in light gauge sheeting, decking and cladding;—...
... 3.1 Codeofpracticefor design of simple and continuous composite beams;— Part 4: Codeofpracticefor design of composite slabs with profiled steel sheeting;— Part 5: Codeofpracticefor ... design of cold formed sections;— Part 61): Codeofpracticefor design of light gauge profiled sheeting;— Part 7: Specification for materials and workmanship: cold formed sections;— Part 8: Code ... sections;— Part 8: Codeofpracticefor fire resistant design;— Part 9: Codeofpracticefor stressed skin design.This Part of BS 5950 gives recommendations for the use of profiled steel sheeting...
... 20 — Key for duopitch roofs 34Figure 21 — Key for hipped roofs 37Figure 22 — Key for mansard and multipitch roofs 38Figure 23 — Key for multi-bay roofs 39Figure 24 — Key for free-standing canopy ... Keys for walls of inset storey 28Figure 16 — Key for flat roofs 30Figure 17 — Key to eave details for flat roofs 32Figure 18 — Key for inset storey 32Figure 19 — Key for monopitch roofs 33Figure ... Cp for free-standing canopy roofs are given in Table 13, Table 14 and Table 15, which take account of the combined effect of the wind on both upper and lower surfaces of the canopy for all...
... Specification for SI units and recommendations for the use of their multiples andof certain other units1).BS 6399, Loading for buildings.BS 6399-1 ,Code ofpracticefor dead and imposed loads.BS ... pitched roofs BRITISH STANDARDBS 6399-3:1988Incorporating Amendments Nos. 1 and 3 and Implementing Amendment No. 2Loading for buildings —Part 3: Codeofpracticefor imposed roof loadsICS ... (a). For asymmetric pitched roofs, each side of the roof should be treated as one half of a corresponding symmetric roof.7.2.3.2 Case 1; uniform load. This results from a uniform layer of snow...
... this Code. By the AISC Committee on the Codeof Standard Practice, Code of Standard Practicefor Steel Buildings and Bridges, March 7, 2000AMERICAN INSTITUTE OF STEEL CONSTRUCTIONvFrank B. Wylie, ... Engineering and Maintenance of WayAssociation.ASME. American Society of Mechanical Engineers.ASTM. American Society for Testing and Materials. Code of Standard Practicefor Steel Buildings and Bridges, ... America Code of Standard Practicefor Steel Buildings and Bridges, March 7, 2000AMERICAN INSTITUTE OF STEEL CONSTRUCTIONii Codeof Standard Practice for Steel Buildings and BridgesMarch 7, 2000Supersedes...