... et al., (2006) “The effect of custom-made braces for the ankle and hindfoot on ankle and foot kinematics and ground reaction forces” Archives of Physical Medicine and Rehabilitation, 87(1) [17] ... Mann R.A., (1996) “Biomechanics of the Foot and Ankle? ?? Surgery of the Foot and Ankle Ed St Louis, Mosby 2–35 [62] Winter D., (2009) “Biomechanics and Motor Control of Human Movement” 4th Edition, ... without the expressed permission of the author An Abstract of Design and Simulation of a Single-Hinge and Adaptive Ankle Foot Orthoses Based on Superelasticity of Shape Memory Alloys by Morteza
Ngày tải lên: 19/06/2023, 09:43
... Engineering Faculty Queensland University of Technology April 2015 Agent-based Modelling and Simulation of Airplane Boarding Processes i Agent-based Modelling and Simulation of Airplane Boarding Processes ... AGENT-BASED MODELLING AND SIMULATION OF AIRPLANE BOARDING PROCESSES Serter IYIGUNLU Submitted in fulfilment of the requirements for the degree of Master of Engineering (Research) Science and Engineering ... Agent-Based Simulation Proceedings of the 2010 Winter Simulation Conference (pp 268-277) Baltimore: IEEE Macal, C., & North, M (2010) Tutorial on agent-based modelling and simulation Journal of Simulation,
Ngày tải lên: 07/08/2017, 12:46
Ebook Diagnostic imaging of the foot and ankle: Part 2
... extremity: a case report and review of the literature J Foot Ankle Surg 1999; 38: 352–358 Bousson V, Hamzé B, Wybier M et al Soft tissue tumors and pseudotumors of the foot and ankle [Article in French] ... Parizel PM Imaging of tumours of the foot and ankle JBR-BTR 2004; 87: 252–257 Waldt S, Rechl H, Rummeny EJ, Woertler K Imaging of benign and malignant soft tissue masses of the foot Eur Radiol 2003; ... foot and ankle Radiographics 1998; 18: 1481–1498 Mitsionis GI, Pakos EE, Kosta P, Batistatou A, Beris A Intramuscular hemangioma of the foot: A case report and review of the literature Foot Ankle
Ngày tải lên: 21/01/2020, 06:12
Ebook Diagnostic imaging of the foot and ankle: Part 1
... K Accuracy of MRI scan in the diagnosis of ligamentous and chondral pathology in the ankle Foot Ankle Surg 2010; 16: 78–80 125 Ankle and Hindfoot Mabit C, Tourné Y, Besse JL et alSofcot (French ... study of outcome and morbidity J Foot Ankle Surg 2010; 49: 541–545 Axial Deformities of the Hindfoot Osteoarthritis of the Ankle Joint with Varus or Valgus Deformity Paley D Principles of Deformity ... debridement and drilling of osteochondral lesions of the talus Foot Ankle Clin 2003; 8: 243–257 Becher C, Thermann H Results of microfracture in the treatment of articular cartilage defects of the
Ngày tải lên: 22/01/2020, 11:14
FluSHELL – A Tool for Thermal Modelling and Simulation of Windings for Large Shell-Type Power Transformers ( TQL )
... Prof José Carlos Lopes Department of Chemical Engineering Faculty of Engineering of the University of Porto Porto Portugal Prof Madalena Maria Dias Department of Chemical Engineering Faculty of ... equivalent degrees of accuracy and detail FluSHELL shows average accuracies of 1.8 °C and 2.4 °C for the average and maximum temperatures, respectively, and the locations of the maximum winding ... average and maximum temperatures of the windings based on a reduced number of parameters and empirical factors Although useful and valid, these tools reflect the current design practices and not
Ngày tải lên: 27/04/2020, 09:11
Distribution patterns of foot and ankle tumors: A university tumor institute experience
... chance of survival and preservation of function [6] The purpose of this study is to report the results of a retrospective, epidemiologic study of bone and soft tissue tumors of the foot and ankle ... prevalence, demography and anatomical distribution of the tumors of the foot and ankle and compare our data with the existing literature Moreover, a simple definition of foot Page of 10 and ankle tumors ... detection of tumors of the foot and ankle, the correct diagnosis is often missed due to a lack of awareness of these entities Additionally, the malignant potential of a tumor on the foot is often
Ngày tải lên: 03/07/2020, 03:00
Modelling and simulation of the capacitive acceleration sensor : Luận văn ThS. Kỹ thuật điện tử - viễn thông : 2.07.00
... principles of openloop and force-balance accelerometers In addition, results of position measurement and noise analysis of the capacitive accelerometer are given Chapter focuses on modeling and simulation ... CHAFTER MODELING AND SIMULATION OF THE ACCELEROMETER 3.1 Overview of SUGAR 3.2 Nodal Analysis Approach 3.3 Simulation Program based on SUGAR 24 26 27 32 35 35 36 45 14 14 15 3.4 Simulation Result ... and design MEMS sensor by modeling and simulation My thesis includes four chapters The first chapter introduces an overview of MEMS and discusses some types of accelerometers Capacitive accelerometer
Ngày tải lên: 23/09/2020, 21:03
(Luận văn thạc sĩ) modelling and simulation of the capacitive acceleration sensor luận văn ths kỹ thuật điện tử viễn thông 2 07 00
... principles of openloop and force-balance accelerometers In addition, results of position measurement and noise analysis of the capacitive accelerometer are given Chapter focuses on modeling and simulation ... CHAFTER MODELING AND SIMULATION OF THE ACCELEROMETER 3.1 Overview of SUGAR 3.2 Nodal Analysis Approach 3.3 Simulation Program based on SUGAR 24 26 27 32 35 35 36 45 14 14 15 3.4 Simulation Result ... and design MEMS sensor by modeling and simulation My thesis includes four chapters The first chapter introduces an overview of MEMS and discusses some types of accelerometers Capacitive accelerometer
Ngày tải lên: 05/12/2020, 09:49
Modelling and simulation of the capacitive acceleration sensor
... principles of openloop and force-balance accelerometers In addition, results of position measurement and noise analysis of the capacitive accelerometer are given Chapter focuses on modeling and simulation ... CHAFTER MODELING AND SIMULATION OF THE ACCELEROMETER 3.1 Overview of SUGAR 3.2 Nodal Analysis Approach 3.3 Simulation Program based on SUGAR 24 26 27 32 35 35 36 45 14 14 15 3.4 Simulation Result ... and design MEMS sensor by modeling and simulation My thesis includes four chapters The first chapter introduces an overview of MEMS and discusses some types of accelerometers Capacitive accelerometer
Ngày tải lên: 16/03/2021, 10:16
Study the release of nitrogen from coated urea granule modelling and simulation
... RELEASE OF NITROGEN FROM COATED UREA GRANULE: MODELLING AND SIMULATION TRINH HOAI THANH DOCTOR OF PHILOSOPHY CHEMICAL ENGINEERING UNIVERSITI TEKNOLOGI PETRONAS AUGUST 2016 STATUS OF THESIS Title of ... the Degree of DOCTOR OF PHILOSOPHY CHEMICAL ENGINEERING UNIVERSITI TEKNOLOGI PETRONAS BANDAR SERI ISKANDAR, PERAK AUGUST 2016 DECLARATION OF THESIS Title of thesis Study the release of nitrogen ... Head of Department: Assoc Prof Dr Suriati Binti Sufian Date: STUDY THE RELEASE OF NITROGEN FROM COATED UREA GRANULE: MODELLING AND SIMULATION by
Ngày tải lên: 27/04/2021, 14:22
elastic plastic properties of multiphase composite based on non homogeneous metal matrix modelling and simulation
... HOMOGENEOUS METAL MATRIX – MODELLING AND SIMULATION? ?? Ludmila Parashkevova, Nikolina Bontcheva Institute of Mechanics, Bulgarian Academy of Sciences, Acad G Bonchev St., Bl 4, 1113 Sofia, Bulgaria, e-mails: ... properties of the composite The theoretical model is applied to description of the properties of precipitation hardening rapidly solidified alloy of the system AlFeVSi with high content of Fe and Si ... RVE of the composite before and after homogenization at micro level, respectively The ratio between the volume fractions of the dark and the light zones in Fig corresponds to the ratio of nano and
Ngày tải lên: 02/11/2022, 09:29
Báo cáo khoa học: Metabolomics, modelling and machine learning in systems biology – towards an understanding of the languages of cells potx
... the heart of understanding the languages of cells The resolution of many of the modern and postgenomic problems of biochemistry requires the development of a myriad of new technologies (and maybe ... range and number of metabolites that one can detect, and these can be exploited as disease markers and in the consequent and principled generation of hypotheses that are consistent with the data and ... to a profoundly different view of the significance of networks in systems biology, and one that allows one a much better understanding of signalling as signal processing Put another way, and again
Ngày tải lên: 07/03/2014, 12:20
COST ACTION E36 Modelling and simulation in pulp and paper industry Proceedings of Model Validation Workshop pot
... exchanges of scientific knowledge within the European Community The main objective of the Action is to promote the development and application of modelling and simulation techniques in pulp and paper ... University of Technology, Finland Fiber classification model development and validation K Villforth, S Schabel, Darmstadt University of Technology, Germany Break 3D simulation of handsheets made of ... Ritala, Tampere University of Technology, Vice Chairman of COST E36; Finland Opening remarks J Manninen, VTT, Chair of Working Group A, Finland Generalization and validation of mathematical models...
Ngày tải lên: 09/03/2014, 01:20
New trends on urban goods movement: modelling and simulation of e-commerce distribution docx
... types of vehicle classes The calculation of the O/D matrices consists of a four step analysis: 1st step Tour and stop generation: calculation and/ or description of the number of tours; number of ... settings: determination of the destinations and modelling of the O-D interactions and single trips Routes construction: their simulation is got by trip chain aggregation The combining of trips to a tour ... average number of truck movements (deliveries/pick-ups) is a function of 45 industry types a, the nature p of the premises (store, warehouse, office, headquarter) and the number o of jobs of the establishment...
Ngày tải lên: 23/03/2014, 10:20
Báo cáo khoa học: Quantitative assessment of the glyoxalase pathway in Leishmania infantum as a therapeutic target by modelling and computer simulation pot
... LSODA routine of odepack [40] Modelling and computer simulation Mathematical modelling and computer simulation were used to evaluate the relative importance of critical parameters of the glyoxalase ... curves and identical results were obtained For Glx I we determined an apparent Km of 0.253 mm and an apparent V of 0.21 lmolặ min)1ặmg)1 (Table 1) while for Glx II a Km of 0.098 mm and a V of 0.18 ... molecular mass thiols of L infantum, at early stationary phase of growth, HPLC analysis of monobromobimane derivatives revealed the presence of GSH and T(SH)2 at retention times of 13.6 and 21.2 min,...
Ngày tải lên: 23/03/2014, 13:20
Báo cáo vật lý: "MODELLING AND SIMULATION STUDY OF VISIBLE EMISSION TRANSMISSIVITY OF SILICON RELATED TO SINGLE AND MULTILAYER ANTIREFLECTION COATINGS" potx
... medium in the far red region of 720–750 nm This paper reports the design and simulation of the transmissivity of single and multilayer coatings; and also reports the results of each design at the central ... the model and basic formula of single and multilayer Journal of Physical Science, Vol 17(2), 15–26, 2006 17 antireflection coatings of Si, SiO2 and Ge for increasing transmittance of Si as active ... transmissivity values of the far red emission of Si using only refractive indices and thickness of coating materials from Si, SiO2 and Ge The maximum transmissivity of Si in 720–750 nm region of the electromagnetic...
Ngày tải lên: 07/08/2014, 14:20
Báo cáo y học: " Foot and ankle surgery in Australia: a descriptive analysis of the Medicare Benefits Schedule database, 1997–2006" potx
... isolated to the foot and ankle (such as excision of soft tissue tumours, treatment of burns, "generic" surgical items and multilevel orthopaedic surgery) were excluded Foot and ankle surgery in ... epidemiology and healthcare costs of surgical procedures [10] (ii) foot and ankle trauma: including treatment of dislocations and fractures of the ankle, tarsals, metatarsals and phalanges (item numbers ... amputations and treatment for chronic arthritic disorders of the forefoot and rearfoot were over-represented in those aged 55 years and over Interestingly, the age distribution of procedures for foot and...
Ngày tải lên: 10/08/2014, 21:23
Instability study of soft materials modelling and simulation
... permission 21 Chapter Modelling of Soft Materials The material modelling of hydrogel is presented in this chapter The modelling and its implementation follows closely the works of Hong et al [2008a, ... variation of normalized nominal stress with volumetric swelling ratio of the sphere under compression of d/R0 = 0.2 33 ix LIST OF FIGURES 4.1 Formation of (a) surface wrinkles and (b) creases and folds ... array of voids ahead of a crack 143 C.3 Close–up view of initial mesh and discrete voids each of f0 = 10−2 A single row of 23 initially spherical voids, with spacing D, is placed ahead of crack...
Ngày tải lên: 10/09/2015, 15:52
Modelling and simulation of faceted boundary structures and dynamics in FCC crystalline materials
... Schematic and continuum model of a faceted grain boundary 110 6.2 The geometries of the simulation cells used in the simulations (a) a pair of Σ3{110} grain boundaries; (b) a pair of Σ11 ... crystallographic axes of one grain to those of the other and to the inclination of the boundary plane) and microscopic degrees of freedom (corresponding to rigid body translations of one grain relative ... and AT B T C T D T , illustrate the slip systems of matrix and twin crystals Because of the mirror symmetry (exchange of left and right) between the two tetrahedra, the cT plane is a mirror of...
Ngày tải lên: 11/09/2015, 10:03
Modelling and simulation of ion implantation induced damage
... guidance of Professor Martin Jaraiz and the support of the Department of Electronics, University of Valladolid (UVa) I am grateful to all for their hospitality and especially to members of the ... composition of an amorphizing 80 keV Carbon implant at (a) 10% and (b) 80% of the total dose of × 1015 cm−2 Simulations were done at 20 ◦ C and at a dose rate of × 1012 cm−2 s−1 102 6.2 2D histograms of ... formation process is highly transient and is governed by the diffusion and reaction of dopant atoms and defects, and especially by the dynamics of clusters of dopant atoms and defects Implantation damage,...
Ngày tải lên: 14/09/2015, 09:22
Bạn có muốn tìm thêm với từ khóa: