... indication of the presence of a weld or welds on the side of the member opposite the weld Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF STEEL CONSTRUCTION ... CONSTRUCTION xiv NOTES Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF STEEL CONSTRUCTION CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES ... Methods and Safety of Erection 1.8.1 The Erector shall be responsible for the means, methods and safety of erection of the Structural Steel frame Code of Standard Practice for Steel Buildings...
Ngày tải lên: 10/08/2014, 11:21
... Maintenance of the Code of Good Practice The operational responsibility for the Code of Good Practice lies with the BCS Registrar The development and maintenance of the Code of Good Practice are ... Code of Practice for Information Security Management Relevant Codes of Practice and Guidance of Other Professional Bodies • • • • • • • • • Code of Professional Conduct and Statement of Best Practice ... the responsibility of the Qualifications and Standards Board The British Computer Society Code of Good Practice version September 2004 Page of 36 This Code of Good Practice is seen as a living...
Ngày tải lên: 18/02/2014, 11:20
Tài liệu Examples of the Standards for Students’ Writing 2009: English Language Arts Grade 9 ppt
... “In order for the shelter to continue providing these services, please inform the public about the effort of these workers to provide for all sorts of animals and the desperate need for more volunteers.” ... Functional Writing Address Information Address Information Use the following information for your letter and to address the envelope below Use the following information for your letter and to address ... situation of being appreciative of the work of an animal shelter in caring for lost or abandoned pets While nearly all students referenced the “services” offered by the shelter, the role of volunteers,...
Ngày tải lên: 24/02/2014, 18:20
Prevention of Environmental Pollution From Agricultural Activity: A CODE OF GOOD PRACTICE pot
... that exists in the Code of Practice for Agricultural Use of Sewage Sludge and the Code of Practice for the Management of Agricultural and Horticultural Waste 14 Account for non-agricultural waste ... recognised good practice 2.5 The total effect of a number of individually minor sources of contamination can be highly significant over an entire catchment area If the sources of water for a river ... note of the guidance on good sheep flock management given in section of this Code Staff should be suitably trained in the correct use of dips and dipping practice SEERAD has issued guidance for...
Ngày tải lên: 15/03/2014, 16:20
Motor vehicle repair Good practice for SMART sprayers docx
... The health risks depend on the chemistry, but for ‘reactive’ products: ❋ isocyanatebased products (including waterbased isocyanate products) may cause asthma and dermatitis; Motor vehicle repair: Good practice for SMART sprayers of 10 pages ... Motor vehicle repair: Good practice for SMART sprayers of 10 pages Health and Safety Executive Figure 3 Airfed halfmask Figure 4 Airfed visor Figure 5 Filtering RPE for non reactive products ... Motor vehicle repair: Good practice for SMART sprayers of 10 pages Health and Safety Executive Figure 6 Chemical protective goggles Figure 7 Protective gloves Location of spraying You need to prevent unprotected people being exposed to spray...
Ngày tải lên: 16/03/2014, 12:20
Code of Standard Practice for Steel Buildings and Bridges Part 1 pdf
... of the American Institute of Steel Construction, Inc or of any other person named herein, that this information is suitable for any general or particular use or of freedom from infringement of ... the initial publication of this edition Printed in the United States of America Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF STEEL CONSTRUCTION ... provided See Section 1.3 Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF STEEL CONSTRUCTION iv • • • • • • • • • • • • • • • Requirements for existing...
Ngày tải lên: 10/08/2014, 11:21
Code of Standard Practice for Steel Buildings and Bridges Part 4 docx
... development of accurate, detailed dimensional information to provide for the fit-up of parts in the field Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF ... the resolution of discrepancies 4.3 Use of CAD Files and/or Copies of Design Drawings The Fabricator shall neither use nor reproduce any part of the Code of Standard Practice for Steel Buildings ... Specifications may also precede the release of the General Conditions and Division Specifications Release of the structural Design Drawings and Code of Standard Practice for Steel Buildings and Bridges,...
Ngày tải lên: 10/08/2014, 11:21
Code of Standard Practice for Steel Buildings and Bridges Part 5 docx
... furnished, nor for the general fit-up of the members that are fabricated from them Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF STEEL CONSTRUCTION ... used without the approval of the Owner’s Designated Representative for Design Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF STEEL CONSTRUCTION 30 ... to the start of fabrication for the information of the Owner’s Designated Representative for Construction, the building-code authority and the Inspector 6.1.3 Members that are made of material...
Ngày tải lên: 10/08/2014, 11:21
Code of Standard Practice for Steel Buildings and Bridges Part 6 pdf
... plus 1/2 in plus 1/8 in for each 10 ft or fraction thereof [13 mm plus mm for each 000 mm or fraction thereof] in excess of 50 ft [15 000 mm] in length For the purpose of inspection, camber shall ... selection of the paint system, the compatibility of the various components of the total paint system, or the length of exposure of the shop coat, the Fabricator cannot guarantee the performance of the ... The effects of additional dead load that may ultimately be intended to be applied, if any Therefore, inspection of the Fabricator’s work on beam camber Code of Standard Practice for Steel Buildings...
Ngày tải lên: 10/08/2014, 11:21
Code of Standard Practice for Steel Buildings and Bridges Part 7 pot
... or after the erection of the Structural Steel frame for the support of loads Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF STEEL CONSTRUCTION ... larger sizes For the purposes of erection stability, the use of leveling nuts and washers is discouraged when base plates have less than four Anchor Rods Code of Standard Practice for Steel Buildings ... Designated Representative for Construction shall be completed so as not to delay or interfere with the work of the Fabricator and the Erector Code of Standard Practice for Steel Buildings and Bridges,...
Ngày tải lên: 10/08/2014, 11:21
Code of Standard Practice for Steel Buildings and Bridges Part 8 pdf
... limitation of the in 500 plumbness tolerance specified for the controlling columns (see Figure C–7.5) Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF STEEL ... sufficient magnitude to allow for the accumulation of mill tolerances and fabrication tolerances, as well as the erection tolerances See Figure C–7.3 Code of Standard Practice for Steel Buildings and ... displacement of 1/16 in [2 mm] is permitted for each additional story up to a maximum Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF STEEL CONSTRUCTION...
Ngày tải lên: 10/08/2014, 11:21
Code of Standard Practice for Steel Buildings and Bridges Part 9 pptx
... other foreign matter that may accumulate during erec- Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF STEEL CONSTRUCTION 64 tion as the result of job-site ... painting Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF STEEL CONSTRUCTION 65 7.18 Final Cleaning Up Upon the completion of erection and before final ... start of work by other trades that may be supported, attached or applied to the Structural Steel frame Code of Standard Practice for Steel Buildings and Bridges, March 7, 2000 AMERICAN INSTITUTE OF...
Ngày tải lên: 10/08/2014, 11:21
Code of Standard Practice for Steel Buildings and Bridges Part 11 ppsx
... Identification of Material Preparation of Material Fitting and Fastening Fabrication Tolerances 6.5 6.6 6.7 7.1 Shop Cleaning and Painting (see also Section 3.1.6) Marking and Shipping of Materials ... Legibility of Design Drawings Revisions to the Design Drawings and Specifications Fast-Track Project Delivery Owner Responsibility Fabricator Responsibility Use of CAD Files and/or Copies of Design ... Standards Units Design Criteria Responsibility for Design Patents and Copyrights Existing Structures Means, Methods and Safety of Erection Definition of Structural Steel Other Steel, Iron or Metal...
Ngày tải lên: 10/08/2014, 11:21
Báo cáo y học: "The development of the Quality Indicator for Rehabilitative Care (QuIRC): a measure of best practice for facilities for people with longer term mental health problems" potx
... identification of the domains of care for inclusion in the toolkit through triangulation of the results of i) a review of care standards in each country, ii) a systematic literature review of the components ... development of an international toolkit to assess the quality of care delivered in hospital and community based mental health units Methods The Development of a European Measure of Best Practice for ... or more of the nine domains by the UK research teams Since some questions were combined for the purposes of scoring, a total of 96 question scores contributed to the rating of domains Of these,...
Ngày tải lên: 11/08/2014, 16:23
Báo cáo y học: " Study protocol for the development of a European measure of best practice for people with long term mental health problems in institutional care (DEMoBinc)" pptx
... Mental health needs of clients of rehabilitation services: a survey in one Trust Journal of Mental Health 17: Epidemiology of schizophrenia Psychoses of Uncertain Aetiology: Handbook of Psychiatry ... assessment of a comprehensive range of key aspects of care It will allow the identification of problem areas that require improvement and it will provide a means to review the effect of changes in practice ... will also provide a means for the assessment of "value for money" in relation to the different domains of care It will be able to provide information on any number of health and social care institutions...
Ngày tải lên: 11/08/2014, 17:20
In search of good predictors for identifying effective spaced seeds in homology search
... part of seeds have good sensitivities Hence, in practice, we may only need to find very good spaced seeds instead of the best one, because (1) the hitting probabilities of very good spaced seeds ... find the identical match of a seed is equivalent to set the seed to be all 1’s (i.e consecutive seed) with the same length of the seed A spaced seed is a specified seed of and ∗ Here we use ∗ to ... a number of predictors for good spaced In chapter four, we propose and discuss the essential features of some seeds filters in order to reduce the number of seeds for consideration before we apply...
Ngày tải lên: 09/10/2015, 11:18
Part 2: Code of practice for wind loads pps
... walls of inset storey Figure 16 — Key for flat roofs Figure 17 — Key to eave details for flat roofs Figure 18 — Key for inset storey Figure 19 — Key for monopitch roofs Figure 20 — Key for duopitch ... for duopitch roofs Figure 21 — Key for hipped roofs Figure 22 — Key for mansard and multipitch roofs Figure 23 — Key for multi-bay roofs Figure 24 — Key for free-standing canopy roofs Figure 25 ... for flat roofs Figure 36 — Examples of zones of flat roof of arbitrary plan shape Figure 37 — Additional zones around inset storey Figure 38 — Key for monopitch roofs Figure 39 — Symmetries for...
Ngày tải lên: 08/07/2014, 22:20
Báo cáo y học: "Efficiency of vibration exercise for glycemic control in type 2 diabetes patients."
... minutes was needed for a training session of the last three weeks Vibration exercise Subjects exercised on a horizontal swinging platform with an amplitude of mm (Vibrogym Professional©) Vibration ... calculated as the distance between knee joint space and contact point of force transduction The best of three trials of each leg were taken for further computation Endurance capacity was determined by ... Schuster for her practical assistance during training sessions, the kind cooperation of the study participants, Vibrogym Ltd and Roche Diagnostics Ltd for the supply of equipments Conflict of interest...
Ngày tải lên: 26/10/2012, 10:04
The challenges for implementation of good manufacturing practices by local pharmaceutical manufactures in vietnam
... and Drug Administration Good Laboratory Practices Good Storage Practices Good Distribution Practices Good Pharmacy Practices Good Prescribing Practices Good Clinical Practices Standard Operating ... (GMP – Good Manufacturing Practices, GLP – Good Laboratory Practices, GSP – Good Storage Practices, GDP – Good Distribution Practices, and GPP – Good Pharmacy Practices) in quality assurance for ... Quality Assurance of Pharmaceutical products GMP Good Manufacturing Practices GLP Good Laboratory Practices GSP Good Storage Practices GDP Good Distribution Practices GPP Good Pharmacy Practices Quality...
Ngày tải lên: 06/11/2012, 10:26