1. Trang chủ
  2. » Giáo Dục - Đào Tạo

Analytical and numerical analyses on stiffness enhancement of ground improved by head enlarged CDM columns

98 15 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 98
Dung lượng 4,69 MB

Nội dung

VIETNAM NATIONAL UNIVESITY HANOI VIETNAM JAPAN UNIVERSITY HOANG DUY PHUONG ANALYTICAL AND NUMERICAL ANALYSES ON STIFFNESS ENHANCEMENT OF GROUND IMPROVED BY HEAD-ENLARGED CDM COLUMNS MAJOR: INFRASTRUCTURE ENGINEERING CODE: 8900201.04QTD RESEARCH SUPERVISOR Dr NGUYEN TIEN DUNG MASTER’S THESIS Hanoi, 2020 TABLE OF CONTENTS ABSTRACT ACKNOWLEDGEMENTS LIST OF TABLES LIST OF FIGURES LIST OF ABBREVIATIONS CHAPTER I: INTRODUCTION 1.1 General introduction of deep mixing method 1.2 Necessity of research 1.3 Objective and Scope of research 1.3.1 Objective of the study 1.3.2 Scope of the study CHAPTER 2: LITERATURE REVIEW 2.1 Overview of deep mixing method 2.1.1 Brief view of deep mixing method 2.1.2 Application of CDM 2.1.3 Classification 2.1.4 Equipment and machine 2.1.5 Construction procedure 2.1.6 Fixed type and floating type improvement 2.2 Improvement of conventional CDM method 2.2.1 T-shaped soil- cement column 2.2.2 The PF method 2.3 Theory of settlement evaluation 2.3.1 The equivalent elastic modulus and 3D settleme 2.4 Theory of numerical method 2.4.1 Preliminaries on material modelling 2.4.2 Linear elastic model 2.4.3 Mohr-Coulomb model 2.4.4 Hardening soil model 2.4.5 Soft soil model CHAPTER 3: METHODOLOGY 3.1 Analysis approaches 3.2 Analyses using analytical method 3.3 Analyses using numerical method CHAPTER 4: LABORATORY AND FIELD TEST 4.1 Introduction of Samse project 4.1.1 General information of project 4.1.2 The PF groups 4.1.3 Soil profile and footing parameters 4.2 Laboratory tests for Samse project 4.3 Static load test on PF groups 47 4.3.1 The geometry and installation PF groups 47 4.3.2 Installing strain gauges 48 4.4 Static load test on single PF column 49 4.4.1 Soil profile 49 4.4.2 Footing parameters 49 CHAPTER 5: SETTLEMENT ANALYSIS AND RESULTS 51 5.1 Settlement analyses using elastic theories 51 5.1.1 Verification analysis 51 5.1.2 Analyses for Ideal case and JEF case 52 5.1.3 Results and discussions 56 5.2 Settlement analyses using nonlinear models 61 5.2.1 Analyses for ideal case 61 5.2.2 Analyses for the experimental single PF column 62 5.2.3 Analyses for PF groups at SAMSE project 63 CHAPTER 6: CONCLUSIONS AND RECOMMENDATIONS 71 6.1 Conclusions 71 6.2 Limitations and suggestions 72 REFERENCES 73 APPENDIX 76 ABSTRACT Point Foundation (PF) method is an advanced technology introduced by EXT Co Ltd company from Korea, which has more advantages than CDM method The shape of PF columns makes a big difference in settlement compared to conventional CDM This study presents a comparative study on stiffness enhancement of grounds improved by Point Foundation method and by the conventional CDM method using analytical and numerical analyses In addition, the analysis results are compared with experimental program The stiffness enhancement is evaluated through induced settlement values under four shallow footing cases, of which one is ideally assumed and the other is an actual footing constructed Results from both analytical analysis and numerical analysis, in which elastic models are used, indicate that in general the PF method produces a more proper stiffness distribution with depth, which in turn results in smaller settlement values Numerical analysis results also indicate that when only soil area under the footing is improved settlement of the footing is significantly larger than that on ground improved entirely, the case of theoretical elastic soil model This is attributed to the influence of larger horizontal displacement around the footing Results from numerical analysis, in which inelastic model used, settlement of shallow footing on PF columns is smaller settlement of conventional CDM columns for the same ground model under certain conditions By true 3D model of column and soil, when the load-settlement is still in relatively linear range, the settlement values from the equivalent soil model and true 3D column and soil model are relatively equal This may suggest the equivalent soil model can be used in practice as it has been used in the elastic analyses PF columns has been analyzed the true behavior between columns and soil (shape of PF column, interaction between column and soil), the results analysis show that when analyzing settlement of shallow footings on PF columns in soft clay, special attention should be paid to the stiffness ratio between PF column and soil ACKNOWLEDGEMENTS I would like to express my sincere appreciation for the lecturers of Master of Infrastructure Engineering Program for their help during my undergraduate at Vietnam Japan University (VJU) First of all, I am very grateful Dr Nguyen Tien Dung, who guided me to conduct this thesis for the part one year He spent a lot of time telling me complicated issues in geotechnical engineering Not about knowledge, he also taught me valuable lesson about the seriousness and carefulness in scientific research These valuable lessons will follow me throughout the future study I would like to acknowledge the sincere inspiration from Prof Nguyen Dinh Duc and Prof Hironori Kato Their lectures covered not only specialist knowledge but also the responsibility and mission of a new generation of Vietnam I am grateful to Dr Phan Le Binh for his support in the last two years since I have studied at Vietnam Japan University Thanks to him, I have learned the professional courtesy of Japanese people as well as Japanese culture I would also like to acknowledge the staff of Vietnam Japan University, Mr Bui Hoang Tan for their help and support I would also like to thank Prof Junichi Koseki, Assoc Prof Kenji Watanabe, Assist Prof Hiroyuki Kyokawa as well as other members of Koseki lab, where I had 80 meaningful days internship at The University of Tokyo It was very helpful to me Special thanks to Associate professor Nguyen Chau Lan, lecturer at University of Transport and Communication His explanations in geotechnical engineering helped me a lot in this study His successful way in research encouraged me more than anything else Thanks to Dr Nguyen Cong Oanh (Vietnam Academic for Water Resources), he explained in detail the complex problems in finite element method for geotechnical engineering Finally, Thanks are due to my family, who are always and support me in studies and research LIST OF TABLES Table 2.1 Typical properties of Stabilized soil (wet method) (Modified from Elias et al 2006) Table 2.2 Typical Properties of Lime–Cement Stabilized Soils (Dry Method) (Modified from Elias et al 2006) Table 4.1 Unconfined compression test results Table 4.2 Strength parameters of samples collected from the PF column Table 5.1 Input parameters for calibration analysis Table 5.2 Input parameters for settlement analysis Table 5.3 Input parameters for the single PF column Table 5.4 Material model and parameter used for Samse factory project LIST OF FIGURES Figure 1.1 Configuration of improved CDM columns: (a) Point foundation (PF) (Nguyen et al 2019a): (b) T-shape column (Liu et al 2012) Figure 2.1 Available ground improvement methods for different soil types (modified from Schaefer et al., 2012) Figure 2.2 Classification of deep mixing method (Kitazume & Terashi, 2013) Figure 2.3 Equipment of deep mixing method (DJM machine) Figure 2.4 Drilling machine (left) and Mixing shaft and blades of DJM machine (right) 11 Figure 2.5 Machine has two mixing shafts and Binder Plant for DJM method (by the courtesy of Dry Jet Mixing Association) Figure 2.6 Type of ground improvement (Kitazume & Terashi, 2013) Figure 2.7 The T-shaped soil cement column overlain by embankment (Song-Yu at el, 2012) Figure 2.8 Displacement of soil under TDM and SCC (Yaolin et al., 2012) Figure 2.9 Load- settlement curves of conventional DCM and TDM pile from physical model test (Chana Phutthananon et al, 2012) Figure 2.10 Site construction of PF method Figure 2.11 Flexible rectangular loaded area Figure 2.12 General three demensional coordinate systems and sign convention for stress Figure 2.13Basicidealofanelasticperfectlyplasticmodel(Plaxismanual) Figure 2.14 The Mohr-Coulomb yield surface in the principal stress space (c=0) Figure 2.15 Hyperbolic stress- strain curve (Ducan & Chang, 1970) Figure 2.16 Stress circles at yield (Plaxis manual) Figure 2.17 Relationship between initial tangent modulus and confining pressure Figure 2.18 Unloading and reloading of silica sand under drain triaxial test consolidation (Ducan and Chang 1970) Figure 2.19 Hyperbolic stress–strain relationship in primary loading for a standard drained triaxial test (Schanz, 1999) Figure 2.20 Representation total yield of the HS model in principle space stress for cohesionless soil Figure 2.21 Yield surface of hardening model (Schanz et al., 1999) Figure Configuration of CDM and PF columns Figure Plan view of SAMSE factory project Figure Plan view of three PF groups Figure 4.3 Shape of PF columns: (Left) Group (L PF=8.5m), (Middle) Group (LPF=6 m); Figure 4.4SoilprofileofSAMSEfactoryproject Figure 4.5 Collection of mixed cement- soil samples Figure 4.6 Secant Modulus E50 46 Figure 4.7 Relationship between secant modulus of elasticity and unconfined compressive strength (SAMSE project) 46 Figure 4.8 Static load test on instrumented PF groups 47 Figure 4.9 Test installation: (a) the geometry of PF columns, (b) increment load applies on steel plate, (c) displacement sensors on steel plate and groundb 47 Figure 4.10 Strain gauge installation: (a) installation of sensors along the depth of PF, (b) setting up sensors into PF, (c) strain gauge instruments, (d) sensor in PF 48 Figure 4.11 Soil profile at Songdo site (Kim et al 2016) 49 Figure 4.12 Configuration of the instrumented column (Kim et al 2016) 50 Figure 4.13 Instrumentations implemented on variable cross-section soft ground reinforced foundation (Kim et al 2016) 50 Figure 5.1 Foundation and soil domain in the numerical analysis 51 Figure 5.2 Comparison of vertical stress profiles obtained from analytical and numerical analyses 52 Figure 5.3 Soil profile under the examined footings (Ideal case) 53 Figure 5.4 Soil profile under the examined footings (JEF project) 54 Figure 5.5 Cross-sectional and plan views of the examined footing at JFE project 55 Figure 5.6 Settlement value from analytical method for Ideal case 57 Figure 5.7 Settlement value from analytical method for JEF case 58 Figure 5.8 Variation of Scorr,PF,min/Scorr,CMD ratio 58 Figure 5.9 Settlement values from analytical and numerical analyses for Ideal case 59 Figure 5.10 Settlement values from analytical and numerical analyses for JEF project 60 Figure 5.11 Settlement analysis from numerical method for ideal case 61 Figure 5.12 Settlement analysis from numerical method for JEF case .61 Figure 5.13 Load- settlement curves from MC model 62 Figure 5.14 Load settlement curves from Numerical method for PF column and conventional CDM 63 Figure 5.15 Load settlement curves from Numerical method for PF columns and CDM columns using equivalent material (E50=150qu) 65 Figure 5.16 Load settlement curves from Numerical method for PF groups and CDM groups using true 3D model of PF columns and soil 66 Figure 5.17 Settlement profiles with depth of footings on PF and CDM columns from numerical method using equivalent material model (q = 800 kPa) 68 Figure 5.18 Load settlement curves from Numerical method for PF columns and conventional CDM columns (Optimal shape design for PF columns) .68 Figure 5.19 Variation of settlement ( ) and effective vertical stress ( v) at the toe of CDM and PF columns obtained from numerical analysis using true 3D model .69 Figure 5.20 Mohr- Coulomb failure criterion 76 LIST OF ABBREVIATIONS as ascc CDM c (c’) Cc Cs D Dh Df Dt eo Ei Eoed E50 Eu Eur Ec Ecomp Es Es HCC HS L Lc Lh Lt M MC Ms NC OCR PF PI qu Improvement area ratio Improvement area ratio of conventional CDM column Cement deep mixing method Cohesion strength Compression index Swelling index Diameter of conventional soil cement column (m) Diameter of cap of HCC (m) Embedded depth (m) Diameter of tail of HCC (m) Initial void ratio Initial tangent modulus Oedometric modulus Scant elastic modulus of soil at 50 percent (kPa) Undrained elastic modulus of soil (kPa) Unloading and reloading Young’s modulus Elastic modulus of soil cement column (kPa) Elastic modulus of improved ground (kPa) Elastic modulus of soil (kPa) Young’s modulus in term of effective stress Head-enlarged soil cement column Hardening soil model Length of conventional soil cement column (m) Length of cone of PF column (m) Length of head of PF column (m) Length of tail of PF column (m) Shape factor for Cam clay ellipse/slope of critical state line Mohr Coulomb model Constrained modulus of soil (kPa) Normal consolidation Over consolidation ratio Point foundation Plasticity index (%) Unconfined compressive strength (kPa) The effectiveness when the treated zone under the footing is modelled as an equivalent material (with secant modulus for PF/CDM columns: E 50 =150qu) Figure 5.15 (a) and (b) show load-settlement curves of the simulated footings on PF columns, CDM columns and from the static load test Two distinct points from the comparison are: Settlement of the footing on PF columns and CDM columns is almost equal Generally, the difference in settlement of footings on PF columns and static load test is not much (less than 10%), this value is accepted for numerical analysis Axial load (kPa) 20 Settlement (mm) 40 60 80 100 120 (a) Group 02 (LPF=6 m) Axial load (kPa) 20 Settlement (mm) 40 60 80 100 120 (b) Group 03 (LPF=4 m) Figure 5.15 Load settlement curves from Numerical method for PF columns and CDM columns using equivalent material (E50=150 qu) 65 Settlement (mm) Axial load (kPa) 1 (a) Group 02 (LPF=6 m) Settlement (mm) Axial load (kPa) (b) Group 03 (LPF=4 m) Figure 5.16 Load settlement curves from Numerical method for PF groups and CDM groups using true 3D model of PF columns and soil (ii) A true 3D model of PF columns and soil Figure 5.16 (a) and (b) show a comparison of load- settlement curves otbained from simulated footings on PF and CDM columns using both equivalent material and true 3D approaches (with secant modulus for PF/CDM columns: E 50 =150qu kPa) and from the Some key points from the results are as follows: 66 Generally, settlement of simulated footing on PF columns is also close to settlement of the footing from static load test This result can be acceptable Settlement of footings on PF (or CDM) columns using equivalent model is slightly smaller than settlement of footings on PF (or CDM) columns using the true 3D model The difference might be attributed to some reasons such as shape of the columns, foundation size (steel plate), soil characteristics, etc However, the settlement discrepancy is unnoticeable when the load-settlement curves in the relatively linear range This means that under service loading conditions, in which settlement curve is almost linear, both models result in rather similar settlement values Settlement of the footings on CDM columns is smaller than settlement of footings on PF columns for both equivalent material and true 3D models For these two experimental PF groups, why is the settlement of footings on CDM columns smaller than settlement of footings on PF columns? This result is against previous finds that the settlement of footings on PF columns is generally smaller settlement of footings on CDM columns Possible reasons and proof As discussed above, there are possible reasons that make settlement of the footings on PF columns smaller than settlement of the footings on CDM columns: Reason 1: The PF columns shape is not the optimal shape In the ideal case and JEF case, there exist a minimum settlement value at certain value in the range of 0.4 to 0.5, but in SAMSE project: (i) =Lh/L=1/6=0.16 < 0.4 for PF columns of group 02 (L PF=6 m); (ii) = Lh/L = 1/4 =0.25 < 0.4 for PF columns of group 03 (L PF = m) These values not make a difference in settlement of shallow footings on PF columns and CDM columns Reason 2: The settlement consists parts: Settlement of improved zone and settlement of layers under improved zone The main difference in stiffness between columns and the soil is so high, therefore, the settlement of improved zone is very small compared with the total settlement 67 Figs 5.17(a) and 5.17(b) show the settlement profiles with depth of the footings on PF groups and As shown, for each group, settlement profiles from footings on PF and CDM columns are almost identical Settlement (mm) Settlement (mm) Depth (m) Settlement (mm) (a) Group 02 (b) Group 03 (c) Optimal shape Figure 5.17 Settlement profiles with depth of footings on PF and CDM columns from numerical method using equivalent material model (q = 800 kPa) Settlement (mm) Axial load (kPa) Figure 5.18 Load settlement curves from Numerical method for PF columns and conventional CDM columns (Optimal shape design for PF columns) 68 q (kPa) ' v,PF ( v,PF) ' v,CDM ( v,CDM) (a) PF group and CDM group in Samse project 800 700 600 load(kPa) 500 Axial 400 300 200 100 0 600 500 load(kPa) 400 Axial 300 200 100 0 (c) Group 03 Figure 5.19 Variation of settlement ( ) and effective vertical stress ( the toe of v) at CDM and PF columns obtained from numerical analysis using true 3D model 69 Fig 5.17(c) shows the settlement profiles of footings on PF group with two parameters changed: (1) the PF columns were extended from Lh = 1.0 m, Lc = 1.0 m, and Lt = 2.0 m (i.e., = 1/4 = 0.25) to have L h = 4.0 m, Lc = 1.0 m, and Lt = 1.0 m (i.e., = 4.0/6.0 = 66); (2) the stiffness ratio of the columns to soil was changed from E c/E s = 150 to E /Es = 65 (an average value taking into account the variation of soil stiffness with depth) c As shown, the settlement of the footing on PF columns is smaller than that on CDM columns The results indicate two important points: (i) the head length should be long enough to cover the upper soft soil layer: (ii) If the stiffness ratio is too high, the settlement of the footings come mainly from the settlement of the soft layers underneath the treated zone Note that common stiffness ratio of 10 to 20 are found from many case studies (Kitazume and Terashi 2013) Fig 5.18 shows load-settlement curves of footings on PF group extended discussed in the previous graph It is very clear that the settlement of the footing on PF columns is smaller than that of CDM columns The results support findings from previous cases Settlement ( ) and effective vertical stress ( v ) at the toe of CDM and PF columns obtained from numerical analysis using true 3D model (Discussed in Fig 5.16; E 50 = 150qu for the PF/CDM columns; using soft soil model) are shown in Fig 5.19 As shown, for group 02 (Fig 5.19(b)) the applied pressure-toe settlement curves as well as applied pressure- toe pressures from PF columns and CDM columns are almost identical However, the group 3, the curve show different trend: both settlement and effective vertical stress at toe PF columns’ toe are larger than the values at CDM columns’ toe This indicates a very important point that soft soil layers under the floating columns play very important in the total settlement of the footing 70 CHAPTER 6: CONCLUSIONS AND RECOMMENDATIONS 6.1 Conclusions This study presents a comparative study on the effectiveness of PF columns and conventional CDM columns in reducing settlement of shallow foundations using analytical method and numerical methods The following are key conclusions drawn from the study On settlement analysis using elastic theory: 1) Under the same ground models, settlement of the footings on PF columns is smaller than that on conventional CDM columns 2) Settlement curves (S versus ) from both analytical method and numerical method show similar trends 3) For each value, an optimal shape of PF column is obtained (i.e., giving minimum settlement) for a certain value of ( , are defined in chapter 4) When varies from 1.4 to 1.6, the optimal PF columns are obtained with varies from 0.4 to 0.6 The optimal settlement from ground improved by PF columns may be as small as 0.9 times that from ground improved by CDM columns On settlement analyses using nonlinear materials: 1) For single columns, settlement of PF column is smaller than settlement of conventional CDM column The larger head of PF column reduces the pressure transfer to the lower portion of the column 2) Under the following conditions: (i) the ratio of stiffness of PF column (or CDM column) over that of the surrounding soil varies from 10 to 20 times; (ii) the head of the PF columns installed sufficiently deep in the soft soil layers, the settlement of footing on PF columns is generally smaller than that on CDM columns The first condition is to make sure that the equivalent material model is applicable When the stiffness of the PF columns (or CDM columns) is much larger than the stiffness of surrounding soil layer (typically larger than 20 times), the columns would act as piles In this case, the effectiveness of PF columns is insignificant 71 On the behavior of true 3D column model over the equivalent material model: Analyses using the true 3D model of columns and soil show that if the PF columns not satisfy the two conditions above then the use of PF columns is not effective By true 3D model of columns and soil, when the load-settlement is still in relatively linear range, the settlement values from the equivalent soil model and true 3D column and soil model are relatively equal This may suggest the equivalent soil model can be used in practice as it has been used in the elastic analyses For 3D column of columns and soil, the settlement of shallow footing on PF columns is affected by soft soil layers under the floating columns In many cases, when using PF columns, pay attention to the position of columns’ toe and stiffness of PF columns 6.2 Limitations and suggestions Limitation: 1) Not fully analyzed the behavior of soil and PF columns (true 3D model of PF column and soil) 2) In four cases, the footing is rigid foundation In case, the footing is flexible foundation, we need analyze settlement of footing on PF columns This is a problem need consider 1) Analysis ultimate bearing capacity of footing on PF columns both numerical method and analytical method by equivalent materials 2) Analysis ultimate bearing capacity of footing on PF columns both numerical method and analytical method by true 3D model of PF columns and soil 72 REFERENCES [1] Bergado, D T (1996) Soft Ground Improvement: In Lowland and Other Environment [2] Bergado, D T., T Ruenkrairergsa, Ã., Taesiri, Y., & Balasubramaniam, A (1999) Deep soil mixing to reduce embankment settlement Ground Improvement [3] Brinkgreve, R B J., E Engin, and W M Swolfs "PLAXIS 3D 2013 user manual." Plaxis bv, Delft (2013) [4] Boussinesq, J (1885) Applications des potentiels l’étude de l’équilibre et mouvement des solides elastiques Gauthier–Villard, Paris [5] Bowles, J E (1977a) Foundation analysis and design [6] Bowles, J E (1977b) Foundation analysis and design McGraw-Hill [7] Bredenberg, H., Broms, B B., & Holm, G (1999) Dry Mix Methods for Deep Soil Stabilization [8] Bruce, M.E.C., Berg, R.R., Collin, J.G., Filz, G.M., Terashi, M and Yang, D .(2013) Federal Highway Administration Design Manual: Deep mixing for embankment and foundation support [9] Chai, J., & Carter, J P (2011) Deformation Analysis in Soft Ground Improvement [10] Das, B M (2015) Principles of Foundation Engineering Cengage Learning [11] Das, B M., & Sobhan, K (2013) Principles of Geotechnical Engineering, SI Edition [12] Duncan, James M., and Chin-Yung Chang "Nonlinear analysis of stress and strain in soils." Journal of Soil Mechanics & Foundations Div (1970) [13] Fahey, M., & Carter, J (1993) A finite element study of the pressuremeter test in sand using nonlinear elastic plastic model Canadian Geotechnical Journal, 30, 348–362 [14] Han, J (2015) Principles and Practice of Ground Improvement Retrieved from Hatanaka, M., & Uchida, A (1996) Empirical Correlation between Penetration Resistance and Internal Friction Angle of Sandy Soils SOILS AND FOUNDATIONS, 36, 1–9 [15] Helwany, S (2007) Applied Soil Mechanics with ABAQUS Applications [16] Holtz, R (1991) Stress Distribution and Settlement of Shallow Foundations 64 [17] J Wardle, L., & A Fraser, R (1976) Numerical analysis of rafts on layered foundations Geotechnique, 26, 613–630 [18] Kim, Khi-Woong, Dong-Wook Kim, and Myoung-Su Jo "Behavior of Variable Cross-Section Soft Ground Reinforced Foundation in Soft Grounds." Journal of the Korean Geosynthetics Society 15.4 (2016): 89-96 [19] Kirsch, K., & Bell, A (2012) Ground Improvement [20] Kitazume, M., & Terashi, M (2013) The Deep Mixing Method 73 [21] Kondner, Robert L "Hyperbolic stress-strain response: cohesive soils." Journal of the Soil Mechanics and Foundations Division 89.1 (1963): 115-143 [22] Kulhawy, Fred H., and Paul W Mayne Manual on estimating soil properties for foundation design No EPRI-EL-6800 Electric Power Research Inst., Palo Alto, CA (USA); Cornell Univ., Ithaca, NY (USA) Geotechnical Engineering Group, 1990 [23] Lambe, T William, and W Allen Marr "Stress path method." Journal of Geotechnical and Geoenvironmental Engineering 105.ASCE 14655 Proceeding (1979) [24] Le, V H., Nguyen, D T., Nguyen, T D., & Tran, Q D (2018) Nonlinear settlement of spreadfootings on sand The Transport Journal, 86–90 Hanoi [25] Liu, Song-Yu, et al "Field investigations on performance of T-shaped deep mixed soil cement column–supported embankments over soft ground." Journal of Geotechnical and Geoenvironmental Engineering 138.6 (2012): 718-727 [26] Mayne, P., & Poulos, H (1999) Approximate Displacement Influence Factors for Elastic Shallow Foundations Journal of Geotechnical and Geoenvironmental Engineering - J GEOTECH GEOENVIRON ENG, 125 [27] Murthy, V N S (2001) Principles of Soil Mechanics and Foundation Engineering [28] Nguyen, D T., Nguyen, T D., Le, V H., & Hoang, D P (2019) Soft ground improvement by an improved CDM method 157-161 Vietnam – Japan Science and Technology Symposium (VJST2019) [29] Nguyen, D T (2019) An evaluation of the effectiveness of head-enlarged soil cement columns (HCC) in ground improvement (Master thesis 2019) [30] Nguyen, Tien Dung, Duy Phuong Hoang, Quynh Giao Tran, and Sung Gyo Chung "Analytical and Numerical Analyses on Stiffness Enhancement of Ground Improved by Head-Enlarged CDM Columns." In Geotechnics for Sustainable Infrastructure Development, pp 579-586 Springer, Singapore, 2020 [31] Obrzud, R The hardening soil model: A practical guidebook Zace Services, 2010 [32] Phutthananon, Chana, et al "Dependence of ultimate bearing capacity and failure behavior of T-shaped deep cement mixing piles on enlarged cap shape and pile strength." Computers and Geotechnics 97 (2018): 27-41 [33] Poulos, H G., & Davis, E H (1974) Elastic solutions for soil and rock mechanics [34] Potts, D M., Zdravković, L., Addenbrooke, T I., Higgins, K G., & Kovačević, N (2001) Finite element analysis in geotechnical engineering: application (Vol 2) London: Thomas Telford [35] Rujikiatkamjorn, C., Indraratna, B., & Chu, P J (2005) Ground Improvement: Case Histories [36] Schanz, T., P A Vermeer, and P G Bonnier "The hardening soil model: formulation and verification." Beyond 2000 in computational geotechnics (1999): 281-296 74 [37] Schmertmann, J.H., Hartman, J.D and Brown, P (1978) Improved Strain Influence Factor Diagrams Journal of the Geotechnical Division, 104(No GT8), 1131–1135 [38] Schofield, Andrew, and Peter Wroth Critical state soil mechanics McGraw-hill, 1968 [39] Skempton, A W (1954) The Pore-Pressure Coefficients A and B Géotechnique, 4(4), 143–147 [40] Song-Yu, L., Yan-Jun, D., Yao-Lin, Y., & J., P A (2012) Field Investigations on 28 Performance of T-Shaped Deep Mixed Soil Cement Column–Supported [41] Embankments over Soft Ground Journal of Geotechnical and Geoenvironmental Engineering, 138(6), 718–727 [42] Enkhtur, Odgerel, et al "Evaluation of the settlement influence factors of shallow foundation by numerical analyses." KSCE Journal of Civil Engineering 17.1 (2013): 85-95 [43] Wood, David Muir Soil behaviour and critical state soil mechanics Cambridge university press, 1990 [44] Yaolin, Y., Songyu, L., Yanjun, D., Zhiduo, Z., & Guangyin, D (2012, June 18) The T-Shaped Deep Mixed Column Application in Soft Ground Improvement Grouting and Deep Mixing 2012, pp 389–399.65 [45] Yi, Y., S Liu, and A J Puppala "Laboratory modelling of T-shaped soil–cement column for soft ground treatment under embankment." Géotechnique 66.1 (2016): 85-89 [46] Yi, Y., Liu, S., & Puppala, A J (2018) Bearing capacity of composite foundation consisting of T-shaped soil- cement column and soft clay Transportation Geotechnics, 15, 47–56 [47] Yi, Yaolin, et al "Vertical bearing capacity behaviour of single Tshaped soil– cement column in soft ground: laboratory modelling, field test, and calculation." Acta Geotechnica 12.5 (2017): 1077-1088 [48] Zwillinger, D (2018) CRC Standard Mathematical Tables and Formulas 75 APPENDIX Appendix A: The relationship between compressive strength and confining pressure may be expressed conveniently in terms of Mohr- Coulomb failure criterion as: ( Figure 5.20 Mohr- Coulomb failure criterion Prove: (1) (2) And: HQ = ccos MN = sin N’I’= From (1), (2) So: 76 ... focused on introduction of concept of the method as well as of a simple analytical method to evaluate settlement of soft ground improved by the PF columns Much of understandings on the PF columns. .. structural conditions, (2) geotechnical conditions, (3) environmental constraints, (4) construction conditions, and (5) reliability and durability Structural conditions: The structural conditions may... allowed construction time, (3) availability of construction material, (4) availability of construction equipment and qualified contractor, and (5) construction cost The selection of a ground improvement

Ngày đăng: 27/10/2020, 19:57

Nguồn tham khảo

Tài liệu tham khảo Loại Chi tiết
[3] Brinkgreve, R. B. J., E. Engin, and W. M. Swolfs. "PLAXIS 3D 2013 user manual." Plaxis bv, Delft (2013) Sách, tạp chí
Tiêu đề: PLAXIS 3D 2013 usermanual
[12] Duncan, James M., and Chin-Yung Chang. "Nonlinear analysis of stress and strain in soils." Journal of Soil Mechanics &amp; Foundations Div (1970) Sách, tạp chí
Tiêu đề: Nonlinear analysis of stressand strain in soils
[18] Kim, Khi-Woong, Dong-Wook Kim, and Myoung-Su Jo. "Behavior of Variable Cross-Section Soft Ground Reinforced Foundation in Soft Grounds." Journal of the Korean Geosynthetics Society 15.4 (2016): 89-96 Sách, tạp chí
Tiêu đề: Behavior ofVariable Cross-Section Soft Ground Reinforced Foundation in SoftGrounds
Tác giả: Kim, Khi-Woong, Dong-Wook Kim, and Myoung-Su Jo. "Behavior of Variable Cross-Section Soft Ground Reinforced Foundation in Soft Grounds." Journal of the Korean Geosynthetics Society 15.4
Năm: 2016
[23] Lambe, T. William, and W. Allen Marr. "Stress path method." Journal of Geotechnical and Geoenvironmental Engineering 105.ASCE 14655 Proceeding (1979) Sách, tạp chí
Tiêu đề: Stress path method
[25] Liu, Song-Yu, et al. "Field investigations on performance of T-shaped deep mixed soil cement column–supported embankments over soft ground." Journal of Geotechnical and Geoenvironmental Engineering 138.6 (2012): 718-727 Sách, tạp chí
Tiêu đề: Field investigations on performance of T-shaped deepmixed soil cement column–supported embankments over soft ground
Tác giả: Liu, Song-Yu, et al. "Field investigations on performance of T-shaped deep mixed soil cement column–supported embankments over soft ground." Journal of Geotechnical and Geoenvironmental Engineering 138.6
Năm: 2012
[32] Phutthananon, Chana, et al. "Dependence of ultimate bearing capacity and failure behavior of T-shaped deep cement mixing piles on enlarged cap shape and pile strength." Computers and Geotechnics 97 (2018): 27-41 Sách, tạp chí
Tiêu đề: Dependence of ultimate bearing capacityand failure behavior of T-shaped deep cement mixing piles on enlarged capshape and pile strength
Tác giả: Phutthananon, Chana, et al. "Dependence of ultimate bearing capacity and failure behavior of T-shaped deep cement mixing piles on enlarged cap shape and pile strength." Computers and Geotechnics 97
Năm: 2018
[36] Schanz, T., P. A. Vermeer, and P. G. Bonnier. "The hardening soil model: formulation and verification." Beyond 2000 in computational geotechnics (1999): 281-296 Sách, tạp chí
Tiêu đề: The hardening soilmodel: formulation and verification
Tác giả: Schanz, T., P. A. Vermeer, and P. G. Bonnier. "The hardening soil model: formulation and verification." Beyond 2000 in computational geotechnics
Năm: 1999
[1] Bergado, D. T. (1996). Soft Ground Improvement: In Lowland and Other Environment Khác
[2] Bergado, D. T., T Ruenkrairergsa, Ã., Taesiri, Y., &amp; Balasubramaniam, A. (1999).Deep soil mixing to reduce embankment settlement. Ground Improvement Khác
[4] Boussinesq, J. (1885). Applications des potentiels à l’étude de l’équilibre et mouvement des solides elastiques. Gauthier–Villard, Paris Khác
[6] Bowles, J. E. (1977b). Foundation analysis and design. McGraw-Hill Khác
[7] Bredenberg, H., Broms, B. B., &amp; Holm, G. (1999). Dry Mix Methods for Deep Soil Stabilization Khác
[8] Bruce, M.E.C., Berg, R.R., Collin, J.G., Filz, G.M., Terashi, M. and Yang, D Khác
[9] Chai, J., &amp; Carter, J. P. (2011). Deformation Analysis in Soft Ground Improvement Khác
[10] Das, B. M. (2015). Principles of Foundation Engineering. Cengage Learning [11] Das, B. M., &amp; Sobhan, K. (2013). Principles of GeotechnicalEngineering, SI Edition Khác
[13] Fahey, M., &amp; Carter, J. (1993). A finite element study of the pressuremeter test in sand using nonlinear elastic plastic model.Canadian Geotechnical Journal, 30, 348–362 Khác
[14] Han, J. (2015). Principles and Practice of Ground Improvement.Retrieved from Hatanaka, M., &amp; Uchida, A. (1996) . Empirical Correlation between Penetration Resistance and Internal Friction Angle of Sandy Soils. SOILS AND FOUNDATIONS, 36, 1–9 Khác
[15] Helwany, S. (2007). Applied Soil Mechanics with ABAQUS Applications Khác
[16] Holtz, R. (1991). Stress Distribution and Settlement of Shallow Foundations. 64 Khác
[17] J. Wardle, L., &amp; A. Fraser, R. (1976). Numerical analysis of rafts on layered foundations. Geotechnique, 26, 613–630 Khác

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN

w