1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Iec 60603 5 1987 scan

53 1 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

NORME INTERNATIONALE INTERNATIONAL STANDARD CEI IEC 603-5 Première édition First edition 1987 Cinquième partie: Connecteurs encartables et connecteurs enfichables pour cartes imprimées double face au pas de 2,54 mm (0,1 in) Connectors for frequencies below MHz for use with printed boards Part 5: Edge-socket connectors and two-part connectors for double-sided printed boards with 2.54 mm (0.1 in) spacing IEC• Numéro de référence Reference number CEI/IEC 603-5: 1987 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Connecteurs pour fréquences inférieures MHz pour utilisation avec cartes imprimées Validité de la présente publication Validity of this publication Le contenu technique des publications de la CEI est constamment revu par la CEI afin qu'il reflète l'état actuel de la technique The technical content of IEC publications is kept under constant review by the IEC, thus ensuring that the content reflects current technology Des renseignements relatifs la date de reconfirmation de la publication sont disponibles auprès du Bureau Central de la CEI Information relating to the date of the reconfirmation of the publication is available from the IEC Central Office Les renseignements relatifs ces révisions, l'établissement des éditions révisées et aux amendements peuvent être obtenus auprès des Comités nationaux de la CEI et dans les documents ci-dessous: Information on the revision work, the issue of revised editions and amendments may be obtained from IEC National Committees and from the following IEC sources: Bulletin de la CEI • IEC Bulletin • Annuaire de la CEI Publié annuellement • IEC Yearbook Published yearly • Catalogue des publications de la CEI Publié annuellement et mis jour régulièrement • Catalogue of IEC publications Published yearly with regular updates Terminologie Terminology En ce qui concerne la terminologie générale, le lecteur se reportera la CEI 50: Vocabulaire Electrotechnique International (VEI), qui se présente sous forme de chapitres séparés traitant chacun d'un sujet défini Des détails complets sur le VEI peuvent être obtenus sur demande Voir également le dictionnaire multilingue de la CEI For general terminology, readers are referred to IEC 50: International Electrotechnical Vocabulary (IEV), which is issued in the form of separate chapters each dealing with a specific field Full details of the IEV will be supplied on request See also the IEC Multilingual Dictionary Les termes et définitions figurant dans la présente publication ont été soit tirés du VEI, soit spécifiquement approuvés aux fins de cette publication The terms and definitions contained in the present publication have either been taken from the IEV or have been specifically approved for the purpose of this publication Symboles graphiques et littéraux Graphical and letter symbols Pour les symboles graphiques, les symboles littéraux et les signes d'usage général approuvés par la CEI, le lecteur consultera: For graphical symbols, and letter symbols and signs approved by the IEC for general use, readers are referred to publications: — la CEI 27: Symboles littéraux utiliser en électro-technique; — IEC 27: Letter symbols to be used in electrical technology; — la CEI 417: Symboles graphiques utilisables sur le matériel Index, relevé et compilation des feuilles individuelles; — IEC 417: Graphical symbols for use on equipment Index, survey and compilation of the single sheets; — la CEI 617: Symboles graphiques pour schémas; — IEC 617: Graphical symbols for diagrams; et pour les appareils électromédicaux, and for medical electrical equipment, — la CEI 878: Symboles graphiques pour équipements électriques en pratique médicale — IEC 878: Graphical symbols for electromedical equipment in medical practice Les symboles et signes contenus dans la présente publication ont été soit tirés de la CEI 27, de la CEI 417, de la CEI 617 et/ou de la CEI 878, soit spécifiquement approuvés aux fins de cette publication The symbols and signs contained in the present publication have either been taken from IEC 27, IEC 417, IEC 617 and/or IEC 878, or have been specifically approved for the purpose of this publication Publications de la CEI établies par le même comité d'études IEC publications prepared by the same technical committee L'attention du lecteur est attirée sur les listes figurant la fin de cette publication, qui énumèrent les publications de la CEI préparées par le comité d'études qui a établi la présente publication The attention of readers is drawn to the end pages of this publication which list the IEC publications issued by the technical committee which has prepared the present publication LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU • NORME INTERNATIONALE INTERNATIONAL STAN DARD CEI IEC 603-5 Première édition First edition 1987 Cinquième partie: Connecteurs encartables et connecteurs enfichables pour cartes imprimées double face au pas de 2,54 mm (0,1 in) Connectors for frequencies below MHz for use with printed boards Part 5: Edge-socket connectors and two-part connectors for double-sided printed boards with 2.54 mm (0.1 in) spacing © CEI 1987 Droits de reproduction réservés — Copyright - all rights reserved Aucune partie de cette publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de l'éditeur No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher Bureau central de la Commission Electrotechnique Internationale 3, rue de Varembé Genève Suisse IEC • Commission Electrotechnique Internationale CODE PRIX International Electrotechnical Commission PRICE CODE MensgyHaponHae 3nenrporexHHVecnaa HOMHCCHri U • Pour prix, voir catalogue en vigueur For price, see current catalogue LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Connecteurs pour fréquences inférieures MHz pour utilisation avec cartes imprimées — — 603-5 © CEI 1987 SOMMAIRE Pages PRÉAMBULE 10 14 PRÉFACE Articles Domaine d'application Désignation de type C E I Caractéristiques communes Dimensions Calibres et montages d'essai 25 32 34 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Caractéristiques Programme des essais 603-5 © I E C 1987 —3— CONTENTS Page FOREWORD PREFACE Clause Scope I E C type designation Common features 10 14 25 33 35 LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Dimensions Gauges and test fixtures Characteristics Test schedule 603-5 © — — CEI 1987 COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE CONNECTEURS POUR FRÉQUENCES INFÉRIEURES À MHz POUR UTILISATION AVEC CARTES IMPRIMÉES Cinquième partie: Connecteurs encartables et connecteurs enfichables pour cartes imprimées double face au pas de 2,54 mm (0,1 in) PRÉAMBULE 2) Ces décisions constituent des recommandations internationales et sont agréées comme telles par les Comités nationaux 3) Dans le but d'encourager l'unification internationale, la CEI exprime le voeu que tous les Comités nationaux adoptent dans leurs règles nationales le texte de la recommandation de la CEI, dans la mesure où les conditions nationales le permettent Toute divergence entre la recommandation de la CEI et la règle nationale correspondante doit, dans la mesure du possible, être indiquée en termes clairs dans cette dernière 4) La CEI n'a fixé aucune procédure concernant le marquage comme indication d'approbation et sa responsabilité n'est pas engagée quand il est déclaré qu'un matériel est conforme l'une de ses recommandations PRÉFACE La présente norme a été établie par le Sous-Comité 48B: Connecteurs, du Comité d'Etudes n° 48, de la CEI: Composants électromécaniques pour équipements électroniques Le texte de cette norme est issu des documents suivants: Règle des Six Mois Rapport de vote 48B(BC)121 48B(BC)129 Pour de plus amples renseignements, consulter le rapport de vote mentionné dans le tableau ci-dessus Les publications suivantes de la CEI sont citées dans la présente norme: 512: Composants électromécaniques pour équipements electroniques: procédures d'essai de base Publications n°' et méthodes de mesure 512-2 (1976): Deuxième partie: Examen général, essais de continuité électrique et de résistance de contact, essais d'isolement et essais de contrainte diélectrique 512-3 (1976): Troisième partie: Essais de courant limite 512-6 (1984): Sixième partie: Essais climatiques et essais de soudure Autre publication citée: Norme ISO 468 (1982): Rugosité de surface — Paramètres, leurs valeurs et les règles générales de la détermination des spécifications LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 1) Les décisions ou accords officiels de la CEI en ce qui concerne les questions techniques, préparés par des Comités d'Etudes où sont représentés tous les Comités nationaux s'intéressant ces questions, expriment dans la plus grande mesure possible un accord international sur les sujets examinés 603-5 © I E C 1987 —5— INTERNATIONAL ELECTROTECHNICAL COMMISSION CONNECTORS FOR FREQUENCIES BELOW MHz FOR USE WITH PRINTED BOARDS Part 5: Edge-socket connectors and two-part connectors for double-sided printed boards with 2.54 mm (0.1 in) spacing FOREWORD 2) They have the form of recommendations for international use and they are accepted by the National Committees in that sense 3) In order to promote international unification, the IEC expresses the wish that all National Committees should adopt the text of the IEC recommendation for their national rules in so far as national conditions will permit Any divergence between the IEC recommendation and the corresponding national rules should, as far as possible, be clearly indicated in the latter 4) The IEC has not laid down any procedure concerning marking as an indication of approval and has no responsibility when an item of equipment is declared to comply with one of its recommendations PREFACE This standard has been prepared by Sub-Committee 48B: Connectors, of IEC Technical Committee No.48: Electromechanical Components for Electronic Equipment The text of this standard is based on the following documents: Six Months' Rule Report on Voting 48B(CO)121 48B(CO)129 Further information can be found in the Report on Voting indicated in the table above The following IEC publications are quoted in this standard: 512: Electromechanical Components for Electronic Equipment: Basic Testing Procedures Publications Nos and Measuring Methods 512-2 (1976): Part 2: General Examination, Electrical Continuity and Contact Resistance Tests, Insulation Tests and Voltage Stress Tests 512-3 (1976): Part 3: Current-carrying Capacity Tests 512-6 (1984): Part 6: Climatic Tests and Soldering Tests Other publication quoted in this standard: ISO Standard 468 (1982): Surface Roughness — Parameters, their Values and General Rules for Specifying Requirements LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU 1) The formal decisions or agreements of the IEC on technical matters, prepared by Technical Committees on which all the National Committees having a special interest therein are represented, express, as nearly as possible, an international consensus of opinion on the subjects dealt with — — 603-5 © CEI 1987 CONNECTEURS POUR FRÉQUENCES INFÉRIEURES À MHz POUR UTILISATION AVEC CARTES IMPRIMÉES Cinquième partie: Connecteurs encartables et connecteurs enfichables pour cartes imprimées double face au pas de 2,54 mm (0,1 in) La présente norme doit être utilisée conjointement avec la Publication 512 de la CE I: Composants électromécaniques pour équipements électroniques; procédures d'essai de base et méthodes de mesure La présente norme concerne une gamme de connecteurs au pas de 2,54 mm (0,1 in) destinés connecter une carte imprimée double face, soit une autre carte imprimée, soit des fils Deux types sont proposés: – Connecteur encartable (en une partie) Le connecteur fixe ou embase (femelle) est destiné s'accoupler avec les contacts d'extrémité de carte imprimée – Connecteur enfichable (en deux parties) Le connecteur fixe ou embase (femelle) est destiné s'accoupler avec le connecteur mobile ou fiche (mâle) relié la carte imprimée Dans ces deux types, les connecteurs fixes ou embases sont les mêmes Les embases sont équipées: soit de sorties souder pour fils, – soit de sorties souder sur carte d'épaisseur maximale 3,44 mm (0,135 in), soit de sorties pour connexions enroulées Les fiches sont sorties plates souder (à cheval) sur carte double face d'épaisseur nominale 1,6 mm (0,063 in) En version connecteurs encartables seulement, la polarisation et le codage sont faits par un dispositif mis la place de deux contacts placés face face LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Domaine d'application 603-5 © I E C 1987 —7— CONNECTORS FOR FREQUENCIES BELOW MHz FOR USE WITH PRINTED BOARDS Part 5: Edge-socket connectors and two-part connectors for double-sided printed boards with 2.54 nun (0.1 in) spacing This standard shall be used in conjunction with IEC Publication 512: Electromechanical Components for Electronic Equipment: Basic Testing Procedures and Measuring Methods This standard covers a range of connectors with 2.54 mm (0.1 in) spacing intended to connect a double sided printed board to another printed board or wires Two kinds of connector are available: – One-part edge-socket connector Fixed connector or (female) receptacle is intended to mate with edge board contacts – Two-part connector Fixed connector or (female) receptacle is intended to mate with free connector of board-mounted (male) connector For these two cases, fixed connectors or (female) receptacles are the same Fixed connectors are available with: – solder terminations for wire, – solder terminations for board up to 3.44 mm (0.135 in), – wrapped terminations Free connectors are provided with flat solder terminations for double sided board of nominal thickness 1.6 mm (0.063 in) For edge-socket connectors only, polarization and coding are available by means of a device mounted instead of two opposite contacts LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Scope — — 603-5 © CEI 1987 Désignation de type C E I Les connecteurs conformes cette publication sont désignés par le système suivant: 603-5 – XXX IEC L N N Référence cette publication Type de connecteur Catégorie climatique Classe = 55/125/56 Classe = 25/085/21 Embase R Type de base des so rties Fiche P D = double rangée (séparée) Sorties de l'embase souder pour fils C pour connexions enroulées W souder sur carte imprimée Y Sorties de la fiche souder cheval sur carte imprimée Note – «L» = lettre «N» = chiffre D LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Nombre total de contacts 38 50 62 74 86 98 7.2 All specimens shall be subjected to the following tests: Test phase Severity or condition of tests IEC Publication 512 Test No Connectors Class Connectors Class Title Visual examination Dimensional examination General examination IEC Publication 512 Test No Connectors Class Connectors Class la There shall be no defect that could affect the normal operation lb The dimensions shall comply with those specified in Sub-clauses 3.1.1: Edge-socket connector, 3.1.2: Two-part connector, 3.1.3: Common values, 4.2.1: Insulating housing, 4.2.2: Terminations of fixed connector, 4.3: Free connector P2 Polarization method 13e n a.* P3 Contact resistance 2a Connection points (according to Sub-clause 5.6) – Six contacts per specimen Edge-socket connector Two-part connector 12 m52 15 m52 12 m52 15 m52 P4 Insulation resistance 3a Test voltage: 500 V Method A, Test gauge (see Sub-clause 5.5) – Five contacts per specimen Edge-socket or free connectors 5000 MS2 1000 MS2 P5 Voltage proof 4a Method A, Test gauge (see Sub-clause 5.5) – Five contacts per specimen Edge-socket or free connectors 750 V r.m.s 750 V r.m.s * n a = not applicable 7.3 The specimens shall then be divided into five groups All connectors in each group shall undergo the tests specified for the relevant group LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Title Pl Requirements Measurement to be performed Test Groupe A Prescriptions Mesures effectuer Essais Ordre des essais Sévérités ou conditions d'essai Titres Connecteurs Classe Connecteurs Classe Titres Publication 512 de la CEI Essais le' Connecteurs Classe AP1 Force de rétention du calibre 16e Méthode A sur l'embase seulement Calibres (voir paragraphe 5.1) – Cinq contacts par échantillon Le calibre doit être retenu AP2 Forces d'insertion et d'extraction 13b Embase sur fiche ou carte d'essai (voir paragraphe 5.2) Par paire de contacts AP3 Soudure 12a Méthode: bain de soudure 230 °C Les sorties sont immergées jusqu'à 1,5 mm de l'isolant Pour la fiche seulement et si nécessaire, méthode: fer souder, dimension B Temps de reprise: h L'étamage doit être continu, régulier et brillant AP4 AP5 Secousses 6b AP6 Vibrations 6d 4a Variation de la résistance de contact 2c Embase ou fiche 750 V valeur efficace n a.* Montage de l'échantillon et câblage (voir paragraphe 5.7) Sévérités des essais 10 Hzà2000Hz 10 Hzà55Hz 0,75 mm 0,75 mm ou 10 g Par direction Par direction 10 cycles 10 cycles 45 2h30min 20 contacts sont parcourus par un courant continu de 100 mA sous 12 V AP7 Chocs 6c n a.* AP8 Accélération 6a n a.* * n a = non applicable Tension de tenue 2,7 N max n a.* Pas de discontinuité supérieure µs Connecteurs Classe 2,7 N max 750 V valeur efficace LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Publication 512 de la CE Essais n° Group A Test phase Requirements Measurement to be performed Test Severity or condition of tests Title IEC Publication 51 Test No Connectors Class Connectors Class Title IEC Publication 512 Test No Connectors Class Connectors Class Gauge retention force 16e Method A on edge-socket connector only Gauges (see Sub-clauses 5.1) — Five contacts per specimen The gauge shall be retained AP2 Insertion and withdrawal forces 13b Edge-socket connector on free connector or test board (see Sub-clause 5.2) Per set of contacts AP3 Soldering 12a Method: solder bath 230°C Termination will be immersed up to 1.5 mm, from the insulating housing For free connector only if necessary, method: soldering iron, size B Recovery time: h The solder coating must be continuous, smooth and bright AP4 AP5 Bump 6b n a.* AP6 Vibration 6d Method of mounting specimen and wire (see Sub-clause 5.7) Severity of tests 10Hz to 2000Hz 10 Hz to 55 Hz 0.75 mm 0.75 mm or 10 g Per direction Per direction 10 cycles 10 cycles 45 2h30min 20 contacts monitored by 12 V 100 mA d.c AP7 Shock 6c n a.* AP8 Acceleration 6a n a.* n a = not applicable 2.7 N max 2.7 N max V:) Voltage proof 4a Variation of contact resistance 2c Edge-socket or free connector 750 V r.m.s n a.* No discontinuity higher than is 750 V r.m.s LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU AP1 Groupe A (suite) Sévérités ou conditions d'essai Titres AP9 Variation rapide de température Publication 512 de la CEI Essais nos lid Connecteurs Classe Connecteurs Classe AP10 AP11 Comme P5 AP12 AP13 AP13 AP13 AP13 AP13 Séquence climatique Chaleur sèche Chaleur humide, cyclique 1°` cycle Froid Basse pression atmosphérique Chaleur humide, cyclique Cycle(s) restant(s) lla Echantillon accouplé lii 11m 125 °C Six cycles 11j 11k —55 °C n a.* 85 °C Deux cycles AP15 Comme P3 AP16 Comme P5 * n a = non applicable Connecteurs Classe 1000 MS2 500 MS2 Résistance d'isolement Tension de tenue Inspection visuelle 3a Embase et fiche 4a Embase et fiche la 750 V valeur 750 V valeur efficace efficace Pas de défaut nuisant au bon fonctionnement Résistance d'isolement haute température 3a Embase et fiche 1000 M62 500 MS2 Résistance d'isolement Résistance de contact 3a Embase et fiche 1000 MS2 500 MS2 2a 12 mS2 15 m62 12 mQ2 15 mQ2 Tension de tenue Forces d'insertion et d'extraction Inspection visuelle 4a Connecteur encartable Connecteur enfichable (en deux parties) Embase et fiche 11m Variante 1: +55 °C Comme P4 AP18 Connecteurs Classe Variante 1: +55 °C —25 °C n a.* AP14 AP17 Publication 512 de la CEI Essais n°s Echantillon accouplé —55 °C 125 °C —25 °C 85 °C Temps de reprise: h Comme P4 AP13 Titres 13b la 750 V valeur 750 V valeur efficace efficace 2,7 N max par paire de contacts Embase sur fiche ou carte d'essai (voir paragraphe 5.2) Pas de défaut nuisant au bon fonctionnement LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Ordre des essais Prescriptions Mesures effectuer Essais Group A (continued) Test phase Severity or condition of tests Rapid change of temperature IEC Publication 51 Test No Connectors Class lid Mated specimen Connectors Class AP10 —55 °C to 125 °C1 —25 °C to 85°C Recovery time: h As P4 AP11 As P5 Title IEC Publication 512 Test No Connectors Class Connectors Class 1000 MQ 500 MS2 Edge-socket and free connectors 750 V r.m.s Edge-socket and 750 V r.m.s free connectors There will be no defects that could affect the normal operation Insulation resistance Voltage proof 3a Visual examination la Insulation resistance at high temperature 3a Edge-socket and free connectors Insulation resistance Contact resistance Voltage proof 3a AP17 Insertion and withdrawal forces 13b AP18 Visual examination la Edge-socket and 1000 MS2 500 MQ free connectors Edge-socket connectors 12 mS2 12 mQ Two-part connector 15 mS2 15 mS2 750 V r.m.s Edge-socket and 750 V r.m.s free connectors 2.7 N max Edge-socket connector on free connector or per set of contacts test board (see Sub-clause 5.2) There will be no defect that could affect the normal operation AP12 AP13 Climatic sequence lla Mated specimen AP13 AP13 Dry heat Damp heat, cyclic lli llm 125 °C Six cycles AP13 AP13 First cycle Cold Low air pressure 11j lk l AP13 Damp heat, cyclic 11m —55 °C n a.* 1000 MS2 500 MS2 Variant 1: +55 °C —25 °C n a.* Variant 1: +55 °C Remaining cycle(s) AP14 As P4 AP15 As P3 AP16 As P5 n a = not applicable 85 °C Two cycles 4a 2a 4a LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Title AP9 Requirements Measurement to be performed Test Groupe B Ordre des essais Sévérités ou conditions d'essai BP2 Forces d'insertion et d'extraction Fonctionnement mécanique Publication 512 de la CEI Essais n°' Connecteurs Classe Connecteurs Classe 13b Embase sur fiche ou carte d'essai (voir paragraphe 5.2) 9a Embase sur fiche ou carte d'essai (voir paragraphe 5.2) Titres Publication 512 de la CEI Essais n°S Connecteurs Classe Connecteurs Classe Par paire de contacts 2,7 N max 2,7 N max Nombre de manoeuvres: 50 I 250 Vitesse: mm/s 10 manoeuvres/min BP3 Chaleur humide, cyclique 11m BP4 BP5 Fonctionnement mécanique 9a Sévérités I Deux cycles Six cycles Variante 1: +55 °C moitié accouplé moitié désaccouplé Comme P3 250 Comme P4 BP7 Comme P5 I BP8 BP9 Comme APi BP11 BP12 Charge statique * n a = non applicable 8b 2a Connecteur encartable connecteur enfichable (en deux parties) 12 mS2 15 m52 12 m52 15 mS2 Résistance d'isolement Tension de tenue Endommagement par sonde d'essai Forces d'insertion et d'extraction Rétention du calibre Inspection visuelle 3a Embase et fiche 1000 MS2 500 MQ 4a Embase et fiche 750 V valeur efficace 750 V valeur efficace Nombre de manoeuvres: BP6 BP10 Résistance de contact n a.* 50 16a n a.* 2,7 N max par paire de contacts 13b Embase sur fiche ou carte d'essai (paragraphe 5.2) 16e Le calibre doit être retenu la Pas de défaut nuisant au bon fonctionnement LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Titres BP1 Prescriptions Mesures effectuer Essais Group B Test Test phase IEC Publication 512 Test No Insertion withdrawal forces 13b BP2 Mechanical operation 9a BP3 Damp heat, cyclic 11m BP4 Mechanical operation 9a Connectors Class Connectors Class Severity Six cycles I Two cycles Variant 1: +55 °C half mated half unmated As P3 250 BP7 As P5 I BP8 BP9 As AP1 BP11 * n a = not applicable 8b Connectors Class Connectors Class Per set of contacts 2.7 N max 2.7 N max Contact resistance 2a Edge-socket connector Two-part connector 12 mS2 15 mS2 12 m5-2 15 m52 Insulation resistance Voltage proof 3a Edge-socket and free connectors Edge-socket and free connectors 1000 MS2 500 MS2 750 V r.m.s 750 V r.m.s Probe damage Insertion and withdrawal forces 16a 13b Gauge retention force Visual examination 16e n a.* Edge-socket connector on free connector or test board (See Sub-clause 5.2) The gauge shall be retained la There shall be no defect that could affect the normal operation Number of operations: As P4 Static load IEC Publication 512 Test No Edge-socket connector on free connector or test board (See Sub-clause 5.2) Edge-socket connector on free connector or test board (See Sub-clause 5.2) Number of operations: 250 I 50 Speed: mm/s 10 operations/min BP6 BP10 Title n a.* 50 4a 2.7 N max per set of contacts LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU BP1 BP12 Requirements Severity or condition of tests Title BP5 Measurement to be performed Ordre des essais Sévérités ou conditions d'essai Titres Publication 512 de la CEI Essais n° Connecteurs Classe Connecteurs Classe CP2 Echantillon non câblé accouplé 21 jours I 56 jours Comme P4 CP3 Comme P3 CP4 Comme P5 CP1 CP5 Prescriptions Mesures effectuer Essais Chaleur humide, essai continu 11c Titres Résistance d'isolement Résistance de contact Tension de tenue Inspection visuelle Publication 512 de la CEI Essais n°s Connecteurs Classe 3a Embase et fiche 2a Connecteur encartable Connecteur en deux parties Embase et fiche 4a la 1000 MQ 12 mQ2 15 m52 750 V valeur efficace Pas de défaut nuisant au bon fonctionnement Connecteurs Classe 500 MQ 12 mQ2 15 m52 750 V valeur efficace LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Groupe C Test Test phase Damp heat, steady state IEC Publication 512 Test No 11c Connectors Class Connectors Class CP2 Specimen unwired and mated 56 days I 21 days As P4 CP3 As P3 CP4 As P5 CP5 Requirements Severity or condition of tests Title CP1 Measurement to be performed Title IEC Publication 512 Test No Connectors Class Connectors Class LA Insulation resistance Contact resistance Voltage proof 3a Visual examination la 2a 4a Edge-socket and 1000 MQ 500 MQ free connectors Edge-socket connector 12 m52 12 mQ Two-part connector 15 mQ 15 mQ2 Edge-socket and 750 V r.m.s 750 V r.m.s free connectors There will be no defect that could affect normal operation LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Group C Ordre des essais Sévérités ou conditions d'essai Titres DP1 Charge électrique et température Publication 512 de la CEI Essais n°' 9b Connecteurs Classe Connecteurs Classe Echantillon câblé avec le fil maximal acceptable par le contact et accouplé: température maximale de fonctionnement 85 °C I 125 °C température de la chambre 60 °C I 90 °C courant appliqué l'échantillon 1,5 A I 1,8 A durée de l'essai: 1000 h temps de reprise: h Comme P3 Courant de mesure: 3A Comme P5 DP2 DP3 DP4 DP5 DP6 Prescriptions Mesures effectuer Essais Sable et poussière DP7 n a = non applicable 11h Titres Publication 512 de la CEI Essais n°s Connecteurs Classe 3a 4b n a.* Inspection visuelle la n a.* 4a la Ch n a.* Résistance d'isolement haute température Résistance de contact Tension de tenue Inspection visuelle Décharges partielles 2b Connecteurs Classe 12 m52 15 m52 750 V valeur efficace Pas de défaut nuisant au bon fonctionnement Connecteur encartable Connecteur deux parties Embase et fiche n a.* 12 m52 15 mS2 750 V valeur efficace LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Groupe D Group D Measurement to be performed Test Title IEC Publication 512 Test No Severity or condition of tests Title Connectors Class DP1 Electrical load and temperature 9b DP2 Connectors Class Specimen wired with maximum wire acceptable by contact and mated: maximum operating temperature 125°C I 85°C temperature of chamber I 90°C 60°C current applied to specimen I 1.8 A 1.5 A duration of test: 1000 h recovery time: h As P3 test current: 3A As P5 DP3 DP4 Connectors Class Insulation resistance at high temperature Contact resistance Voltage proof Visual examination Partial discharge DP5 DP6 Sand and dust DP7 * n a = not applicable 11h IEC Publication 512 Test No 3a 2b 4a la n a.* Edge-socket connector 12 mS2 12 m52 Two-part connector 15 mS2 15 mS2 Edge-socket and 750 V r.m.s 750 V r.m.s free connectors There will be no defect that could affect normal operation 4b n a.* la n a.* n a Visual examination Connectors Class LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Test phase Requirements Mesures effectuer Essais Ordre des essais Prescriptions Sévérités ou conditions d'essai Titres Publication 512 de la CE Essais n EP1 Robustesse des sorties 16f EP2 Rétention du contact dans l'isolant 15a * n a = non applicable Connecteurs Classe Connecteurs Classe Titres Publication 512 de la CEI Essais n°' Connecteurs Classe Connecteurs Classe n a.* Sur l'embase seulement Force axiale de traction: 20 N Force axiale de poussée, sortie souder: 20 N Sortie pour connexion enroulée: 30 N Sortie pour connexion point point par clip: 68 N Après suppression de la force, le déplacement du contact devra être inférieur 0,3 mm LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Groupe E Test Test phase Measurement to be performed Requirements Severity or condition of tests Title IEC Publicaon 512 Test No EP1 Robustness of terminations 16f EP2 Contact retention in insert 15a n a = not applicable Connectors Class Connectors Class Title IEC Publication 512 Test No Connectors Class Connectors Class n a.* On edge-socket connector only Axial pull force: 20 N Axial push force Solder termination: 20 N Wrapped termination: 30 N Clip termination: 68 N After the force is removed, the contact movement will have to be less than 0.3 mm LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU Group E LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU LICENSED TO MECON Limited - RANCHI/BANGALORE FOR INTERNAL USE AT THIS LOCATION ONLY, SUPPLIED BY BOOK SUPPLY BUREAU ICS 31.220.10 Typeset and printed by the IEC Central Office GENEVA, SWITZERLAND

Ngày đăng: 17/04/2023, 10:35

Xem thêm:

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN