BS EN 61784-5-11:2013 BSI Standards Publication Industrial communication networks — Profiles Part 5-11: Installation of fieldbuses — Installation profiles for CPF 11 BRITISH STANDARD BS EN 61784-5-11:2013 National foreword This British Standard is the UK implementation of EN 61784-5-11:2013 It is identical to IEC 61784-5-11:2013 It supersedes BS EN 61784-5-11:2012 which is withdrawn The UK participation in its preparation was entrusted to Technical Committee AMT/7, Industrial communications: process measurement and control, including fieldbus A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © The British Standards Institution 2014 Published by BSI Standards Limited 2014 ISBN 978 580 84198 ICS 25.040.40; 35.100.40 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2014 Amendments/corrigenda issued since publication Date Text affected BS EN 61784-5-11:2013 EN 61784-5-11 EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM December 2013 ICS 25.040.40; 35.100.40 Supersedes EN 61784-5-11:2012 English version Industrial communication networks Profiles Part 5-11: Installation of fieldbuses Installation profiles for CPF 11 (IEC 61784-5-11:2013) Réseaux de communication industriels Profils Partie 5-11: Installation des bus de terrain - Profils d'installation pour CPF 11 (CEI 61784-5-11:2013) Industrielle Kommunikationsnetze Profile Teil 5-11: Feldbusinstallation Installationsprofile für die Kommunikationsprofilfamilie 11 (IEC 61784-5-11:2013) This European Standard was approved by CENELEC on 2013-10-22 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels © 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members Ref No EN 61784-5-11:2013 E BS EN 61784-5-11:2013 EN 61784-5-11:2013 -2- Foreword The text of document 65C/738/FDIS, future edition of IEC 61784-5-11, prepared by SC 65C "Industrial networks" of IEC/TC 65 "Industrial-process measurement, control and automation" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61784-5-11:2013 The following dates are fixed: • latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-07-22 • latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2016-10-22 This document supersedes EN 61784-5-11:2012 EN 61784-5-11:2013 includes EN 61784-5-11:2012: the following significant technical changes with respect to – addition of a new Annex C (normative) This standard is to be used in conjunction with EN 61918:2013 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights Endorsement notice The text of the International Standard IEC 61784-5-11:2013 was approved by CENELEC as a European Standard without any modification BS EN 61784-5-11:2013 EN 61784-5-11:2013 -3- Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies Annex ZA of EN 61918:2013 applies, except as follows: Publication Year Title EN/HD Year EN 61918 2013 Addition to Annex ZA of EN 61918:2013: IEC 61918 2013 Industrial communication networks Installation of communication networks in industrial premises –2– BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 CONTENTS INTRODUCTION 10 Scope 11 Normative references 11 Terms, definitions and abbreviated terms 11 CPF 11: Overview of installation profiles 11 Installation profile conventions 11 Conformance to installation profiles 12 Annex A (normative) CP 11/1 (TCnet-star) specific installation profile 14 A.1 Installation profile scope 14 A.2 Normative references 14 A.3 Installation profile terms, definitions, and abbreviated terms 14 A.4 Installation planning 14 A.4.1 General 14 A.4.2 Planning requirements 14 A.4.2.1 Safety 14 A.4.2.2 Security 14 A.4.2.3 Environmental considerations and EMC 14 A.4.2.4 Specific requirements for generic cabling in accordance with ISO/IEC 24702 14 A.4.3 Network capabilities 14 A.4.3.1 Network topology 14 A.4.3.2 Network characteristics 15 A.4.4 Selection and use of cabling components 17 A.4.4.1 Cable selection 17 A.4.4.2 Connecting hardware selection 18 A.4.4.3 Connections within a channel/permanent link 20 A.4.4.4 Terminators 20 A.4.4.5 Device location and connection 20 A.4.4.6 Coding and labelling 20 A.4.4.7 Earthing and bonding of equipment and devices and shielded cabling 20 A.4.4.8 Storage and transportation of cables 20 A.4.4.9 Routing of cables 20 A.4.4.10 Separation of circuit 20 A.4.4.11 Mechanical protection of cabling components 21 A.4.4.12 Installation in special areas 21 A.4.5 Cabling planning documentation 21 A.4.6 Verification of cabling planning specification 21 A.5 Installation implementation 21 A.5.1 General requirements 21 A.5.2 Cable installation 21 A.5.2.1 General requirements for all cabling types 21 A.5.2.2 Installation and routing 22 A.5.2.3 Specific requirements for CPs 22 BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 –3– A.5.2.4 Specific requirements for wireless installation 22 A.5.2.5 Specific requirements for generic cabling in accordance with ISO/IEC 24702 22 A.5.3 Connector installation 22 A.5.4 Terminator installation 22 A.5.5 Device installation 22 A.5.6 Coding and labelling 22 A.5.7 Earthing and bonding of equipment and devices and shield cabling 22 A.5.8 As-implemented cabling documentation 22 A.6 Installation verification and installation acceptance test 22 A.6.1 General 22 A.6.2 Installation verification 22 A.6.2.1 General 22 A.6.2.2 Verification according to cabling planning documentation 22 A.6.2.3 Verification of earthing and bonding 22 A.6.2.4 Verification of shield earthing 22 A.6.2.5 Verification of cabling system 22 A.6.2.6 Cable selection verification 22 A.6.2.7 Connector verification 23 A.6.2.8 Connection verification 23 A.6.2.9 Terminators verification 23 A.6.2.10 Coding and labelling verification 23 A.6.2.11 Verification report 23 A.6.3 Installation acceptance test 23 A.6.3.1 General 23 A.6.3.2 Acceptance test of Ethernet-based cabling 23 A.6.3.3 Acceptance test of non-Ethernet-based cabling 23 A.6.3.4 Specific requirements for wireless installation 23 A.6.3.5 Acceptance test report 23 A.7 Installation administration 23 A.8 Installation maintenance and installation troubleshooting 23 Annex B (normative) CP 11/2 (TCnet-loop 100) specific installation profile 24 B.1 Installation profile scope 24 B.2 Normative references 24 B.3 Installation profile terms, definitions, and abbreviated terms 24 B.4 Installation planning 24 B.4.1 General 24 B.4.2 Planning requirements 24 B.4.2.1 Safety 24 B.4.2.2 Security 24 B.4.2.3 Environmental considerations and EMC 24 B.4.2.4 Specific requirements for generic cabling in accordance with ISO/IEC 24702 24 B.4.3 Network capabilities 24 B.4.3.1 Network topology 24 B.4.3.2 Network characteristics 24 B.4.4 Selection and use of cabling components 27 B.4.4.1 Cable selection 27 –4– BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 B.4.4.2 B.4.4.3 B.4.4.4 B.4.4.5 B.4.4.6 B.4.4.7 Connecting hardware selection 28 Connections within a channel/permanent link 30 Terminators 30 Device location and connection 30 Coding and labelling 30 Earthing and bonding of equipment and devices and shielded cabling 30 B.4.4.8 Storage and transportation of cables 30 B.4.4.9 Routing of cables 30 B.4.4.10 Separation of circuit 30 B.4.4.11 Mechanical protection of cabling components 31 B.4.4.12 Installation in special areas 31 B.4.5 Cabling planning documentation 31 B.4.6 Verification of cabling planning specification 31 B.5 Installation implementation 31 B.5.1 General requirements 31 B.5.2 Cable installation 31 B.5.2.1 General requirements for all cabling types 31 B.5.2.2 Installation and routing 32 B.5.2.3 Specific requirements for CPs 32 B.5.2.4 Specific requirements for wireless installation 32 B.5.2.5 Specific requirements for generic cabling in accordance with ISO/IEC 24702 32 B.5.3 Connector installation 32 B.5.4 Terminator installation 32 B.5.5 Device installation 32 B.5.6 Coding and labelling 32 B.5.7 Earthing and bonding of equipment and devices and shield cabling 32 B.5.8 As-implemented cabling documentation 33 B.6 Installation verification and installation acceptance test 33 B.6.1 General 33 B.6.2 Installation verification 33 B.6.2.1 General 33 B.6.2.2 Verification according to cabling planning documentation 33 B.6.2.3 Verification of earthing and bonding 33 B.6.2.4 Verification of shield earthing 33 B.6.2.5 Verification of cabling system 33 B.6.2.6 Cable selection verification 33 B.6.2.7 Connector verification 33 B.6.2.8 Connection verification 33 B.6.2.9 Terminators verification 33 B.6.2.10 Coding and labelling verification 33 B.6.2.11 Verification report 33 B.6.3 Installation acceptance test 33 B.6.3.1 General 33 B.6.3.2 Acceptance test of Ethernet-based cabling 33 B.6.3.3 Acceptance test of non-Ethernet-based cabling 33 B.6.3.4 Specific requirements for wireless installation 33 B.6.3.5 Acceptance test report 34 BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 –5– B.7 Installation administration 34 B.8 Installation maintenance and installation troubleshooting 34 Annex C (normative) CP 11/3 (TCnet-loop 1G) specific installation profile 35 C.1 Installation profile scope 35 C.2 Normative references 35 C.3 Installation profile terms, definitions, and abbreviated terms 35 C.4 Installation planning 35 C.4.1 General 35 C.4.2 Planning requirements 35 C.4.2.1 Safety 35 C.4.2.2 Security 35 C.4.2.3 Environmental considerations and EMC 35 C.4.2.4 Specific requirements for generic cabling in accordance with ISO/IEC 24702 35 C.4.3 Network capabilities 35 C.4.3.1 Network topology 35 C.4.3.2 Network characteristics 35 C.4.4 Selection and use of cabling components 37 C.4.4.1 Cable selection 37 C.4.4.2 Connecting hardware selection 37 C.4.4.3 Connections within a channel/permanent link 38 C.4.4.4 Terminators 38 C.4.4.5 Device location and connection 39 C.4.4.6 Coding and labelling 39 C.4.4.7 Earthing and bonding of equipment and devices and shielded cabling 39 C.4.4.8 Storage and transportation of cables 39 C.4.4.9 Routing of cables 39 C.4.4.10 Separation of circuit 39 C.4.4.11 Mechanical protection of cabling components 39 C.4.4.12 Installation in special areas 39 C.4.5 Cabling planning documentation 39 C.4.6 Verification of cabling planning specification 39 C.5 Installation implementation 40 C.5.1 General requirements 40 C.5.2 Cable installation 40 C.5.2.1 General requirements for all cabling types 40 C.5.2.2 Installation and routing 40 C.5.2.3 Specific requirements for CPs 40 C.5.2.4 Specific requirements for wireless installation 40 C.5.2.5 Specific requirements for generic cabling in accordance with ISO/IEC 24702 40 C.5.3 Connector installation 40 C.5.4 Terminator installation 40 C.5.5 Device installation 40 C.5.6 Coding and labelling 40 C.5.7 Earthing and bonding of equipment and devices and shield cabling 40 C.5.8 As-implemented cabling documentation 41 –6– BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 C.6 Installation verification and installation acceptance test 41 C.6.1 General 41 C.6.2 Installation verification 41 C.6.2.1 General 41 C.6.2.2 Verification according to cabling planning documentation 41 C.6.2.3 Verification of earthing and bonding 41 C.6.2.4 Verification of shield earthing 41 C.6.2.5 Verification of cabling system 41 C.6.2.6 Cable selection verification 41 C.6.2.7 Connector verification 41 C.6.2.8 Connection verification 41 C.6.2.9 Terminators verification 41 C.6.2.10 Coding and labelling verification 41 C.6.2.11 Verification report 41 C.6.3 Installation acceptance test 41 C.6.3.1 General 41 C.6.3.2 Acceptance test of Ethernet-based cabling 41 C.6.3.3 Acceptance test of non-Ethernet-based cabling 41 C.6.3.4 Specific requirements for wireless installation 41 C.6.3.5 Acceptance test report 42 C.7 Installation administration 42 C.8 Installation maintenance and installation troubleshooting 42 Figure – Standards relationships 10 Table A.1 – Network characteristics for balanced cabling based on Ethernet 15 Table A.2 – Network characteristics for optical fibre cabling 16 Table A.3 – Information relevant to copper cable: fixed cables 17 Table A.4 – Information relevant to copper cable: cords 17 Table A.5 – Information relevant to optical fibre cables 18 Table A.6 – Connectors for balanced cabling CPs based on Ethernet 19 Table A.7 – Optical fibre connecting hardware 19 Table A.8 – Relationship between FOC and fibre types (CP 11/1) 19 Table A.9 – Recommended minimum distances specific for CP 11/1 20 Table A.10 – Parameters for balanced cables 21 Table A.11 – Parameters for silica optical fibre cables 21 Table B.1 – Network characteristics for balanced cabling based on Ethernet 25 Table B.2 – Network characteristics for optical fibre cabling 26 Table B.3 – Information relevant to copper cable: fixed cables 27 Table B.4 – Information relevant to copper cable: cords 27 Table B.5 – Information relevant to optical fibre cables 28 Table B.6 – Connectors for balanced cabling CPs based on Ethernet 29 Table B.7 – Optical fibre connecting hardware 29 Table B.8 – Relationship between FOC and fibre types (CP 11/2) 29 Table B.9 – Recommended minimum distances specific for CP 11/2 31 Table B.10 – Parameters for balanced cables 31 – 30 – B.4.4.2.7 BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 Specific requirements for generic cabling in accordance with ISO/IEC 24702 B.4.4.3 Connections within a channel/permanent link B.4.4.4 Terminators Subclause 4.4.4.2 is not applicable B.4.4.5 Device location and connection Subclause 4.4.5.2 is not applicable B.4.4.6 Coding and labelling Subclause 4.4.6.3 has addition: The planner shall request to use redundancy cables of different colours and identify each of the two cables with labelling B.4.4.7 Earthing and bonding of equipment and devices and shielded cabling B.4.4.7.1 Common description B.4.4.7.2 Bonding and earthing of enclosures and pathways B.4.4.7.3 Earthing methods B.4.4.7.4 Shield earthing Subclause 4.4.7.4.1 is not applicable Subclause 4.4.7.4.2 is not applicable Subclause 4.4.7.4.3 has addition: The communication shields shall be directly earthed at the one end of the channel (see IEC 61918:2013, Figure 35) B.4.4.7.5 Specific requirements for CPs Not applicable B.4.4.7.6 B.4.4.8 Specific requirements for generic cabling in accordance with ISO/IEC 24702 Storage and transportation of cables Subclause 4.4.8.2 is not applicable B.4.4.9 Routing of cables B.4.4.10 Separation of circuit Addition: The cabling outside of enclosure should be separated at the distance of m from the power cables and the apparatuses that generate the electro-magnetic field If the separation of m is difficult, the minimum distance shall be assured according to the Table B.9 BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 – 31 – Table B.9 – Recommended minimum distances specific for CP 11/2 Minimum distances for the specified current m Specified voltage V B.4.4.11 < 10 A ≥ 10 A ≥ 50 A < 50 A < 100 A ≥ 100 A < 60 0,15 0,3 0,5 ≥ 60 < 110 0,3 0,5 0,6 ≥ 110 < 220 0,5 0,6 0,6 ≥ 220 < 440 0,6 0,6 0,6 ≥ 440 2 2 Mechanical protection of cabling components Subclause 4.4.11.2 is not applicable B.4.4.12 Installation in special areas Subclause 4.4.12.2 is not applicable B.4.5 Cabling planning documentation B.4.6 Verification of cabling planning specification B.5 Installation implementation B.5.1 General requirements B.5.2 Cable installation B.5.2.1 General requirements for all cabling types Subclause 5.2.1.2 has replacement: Table B.10 provides values based on the template given in IEC 61918:2013, Table 18 Table B.10 – Parameters for balanced cables Characteristic Minimum bending radius, single bending (mm) Bending radius, multiple bending (mm) Mechanical force Pull forces (N) a Value 21 (after installation) 52 (during installation) ≥ 21 – a Permanent tensile forces (N) – a Maximum lateral forces (N/cm) – a Temperature range during installation (°C) – a Depending on cable type; see manufacturer’s data sheet Table B.11 provides values based on the template given in IEC 61918:2013, Table 19 – 32 – BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 Table B.11 – Parameters for silica optical fibre cables Characteristic Minimum bending radius, single bending (mm) Bending radius, multiple bending (mm) Mechanical force Pull forces (N) a Value 170 (after installation) 340 (during installation) ≥ 170 – a Permanent tensile forces (N) – a Maximum lateral forces (N/cm) – a Temperature range during installation (°C) – a Depending on cable type; see manufacturer’s data sheet B.5.2.2 Installation and routing B.5.2.3 Specific requirements for CPs Not applicable B.5.2.4 Specific requirements for wireless installation Not applicable B.5.2.5 B.5.3 Specific requirements for generic cabling in accordance with ISO/IEC 24702 Connector installation Subclause 5.3.4 is not applicable B.5.4 Terminator installation Subclause 5.4.2 is not applicable B.5.5 Device installation Subclause 5.5.2 is not applicable B.5.6 Coding and labelling Subclause 5.6.2 is not applicable B.5.7 Earthing and bonding of equipment and devices and shield cabling Subclause 5.7.5 is not applicable BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 B.5.8 B.6 – 33 – As-implemented cabling documentation Installation verification and installation acceptance test B.6.1 General B.6.2 Installation verification B.6.2.1 General B.6.2.2 Verification according to cabling planning documentation B.6.2.3 Verification of earthing and bonding Subclause 6.2.3.2 is not applicable B.6.2.4 Verification of shield earthing B.6.2.5 Verification of cabling system B.6.2.6 Cable selection verification Subclause 6.2.6.2 is not applicable B.6.2.7 Connector verification Subclause 6.2.7.2 is not applicable B.6.2.8 Connection verification B.6.2.9 Terminators verification Subclause 6.2.9.2 is not applicable B.6.2.10 Coding and labelling verification Subclause 6.2.10.2 is not applicable B.6.2.11 B.6.3 Verification report Installation acceptance test B.6.3.1 General B.6.3.2 Acceptance test of Ethernet-based cabling Subclause 6.3.2.2.2 is not applicable B.6.3.3 Acceptance test of non-Ethernet-based cabling Not applicable B.6.3.4 Specific requirements for wireless installation Not applicable – 34 – B.6.3.5 B.7 BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 Acceptance test report Installation administration Subclause 7.8 is not applicable B.8 Installation maintenance and installation troubleshooting Subclause 8.4 is not applicable BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 – 35 – Annex C (normative) CP 11/3 (TCnet-loop 1G) specific installation profile C.1 Installation profile scope Addition: This standard specifies the installation profile for Communication Profile CP 11/3 (TCnetloop 1G) The CP 11/3 is specified in IEC 61784-2 C.2 Normative references C.3 Installation profile terms, definitions, and abbreviated terms Subclause 3.3 is not applicable C.4 Installation planning C.4.1 General Subclause 4.1.4 is not applicable C.4.2 C.4.2.1 Planning requirements Safety Subclause 4.2.1.3 is not applicable Subclause 4.2.1.4 is not applicable C.4.2.2 Security Not applicable C.4.2.3 Environmental considerations and EMC C.4.2.4 Specific requirements for generic cabling in accordance with ISO/IEC 24702 C.4.3 C.4.3.1 Network capabilities Network topology Subclause 4.3.1.4 is not applicable Subclause 4.3.1.5 has addition: Ring topology applies to CP 11/3 network C.4.3.2 C.4.3.2.1 Network characteristics General BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 – 36 – C.4.3.2.2 Network characteristics for balanced cabling not based on Ethernet Not applicable C.4.3.2.3 Network characteristics for balanced cabling based on Ethernet Not applicable C.4.3.2.4 Network characteristics for optical fibre cabling Replacement: Table C.1 provides values based on the template given in IEC 61918:2013, Table Table C.1 – Network characteristics for optical fibre cabling CP 11/3 Optical fibre type Single mode silica Multimode silica Description Bandwidth (MHz) or equivalent at λ (nm) Minimum length (m) Maximum length a (m) 000 Maximum channel Insertion loss/optical power budget (dB) 6,5 Connecting hardware See C.4.4.2.5 Modal bandwidth (MHz × km) at λ (nm) – Minimum length (m) – Maximum POF (m) – – Connecting hardware – Modal bandwidth (MHz × 100 m) at λ (nm) – Minimum length (m) – length a (m) – Maximum channel Insertion loss/optical power budget (dB) – Connecting hardware – Modal bandwidth (MHz × km) at λ (nm) – Minimum length (m) – Maximum a length a Maximum channel Insertion loss/optical power budget (dB) Maximum Hard clad silica 500 length a (m) – Maximum channel Insertion loss/optical power budget (dB) – Connecting hardware – This value is reduced by connections, splices and bends in accordance with formula (1) in 4.4.3.4.1 of IEC 61918:2013 BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 C.4.3.2.5 – 37 – Specific network characteristics Not applicable C.4.3.2.6 C.4.4 Specific requirements for generic cabling in accordance with ISO/IEC 24702 Selection and use of cabling components C.4.4.1 Cable selection C.4.4.1.1 Common description C.4.4.1.2 Copper cables Not applicable C.4.4.1.3 Cables for wireless installation C.4.4.1.4 Optical fibre cables Replacement: Table C.2 provides values based on the template given in IEC 61918:2013, Table Table C.2 – Information relevant to optical fibre cables Characteristic 50/125 µm multimode silica 10/125 µm single mode silica 62,5/125 µm multimode silica 980/1 000 µm step index POF 200/230 µm step index hard clad silica Standard IEC 60793-2-50 Type B1.1 – – – – Attenuation per km (650 nm) – – – – – Attenuation per km (820 nm) – – – – – Attenuation per km (1 310 nm) 0,5 dB/km – – – – Number of optical fibres – – – – Jacket colour requirements – – – – – Jacket material – – – – – Resistance to harsh environment (e.g UV, oil resist, LS0H) – – – – – C.4.4.1.5 Special purpose balanced and optical fibre cables C.4.4.1.6 Specific requirements for CPs Not applicable C.4.4.1.7 C.4.4.2 C.4.4.2.1 Specific requirements for generic cabling in accordance with ISO/IEC 24702 Connecting hardware selection Common description BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 – 38 – C.4.4.2.2 Connecting hardware for balanced cabling CPs based on Ethernet Not applicable C.4.4.2.3 Connecting hardware for copper cabling CPs not based on Ethernet Not applicable C.4.4.2.4 C.4.4.2.5 Connecting hardware for wireless installation Connecting hardware for optical fibre cabling Replacement: Table C.3 provides values based on the template given in IEC 61918:2013, Table Table C.3 – Optical fibre connecting hardware IEC 61754-2 IEC 61754-4 IEC 61754-24 BFOC 2.5 SC SC-RJ LC F-SMA No No No Yes No CP 11/3 IEC 61754-20 IEC 61754-22 Others No NOTE IEC 61754 series defines the optical fibre connector mechanical interfaces; performance specifications for optical fibre connectors terminated to specific fibre types are standardised in IEC 61753 series Replacement: Table C.4 provides values based on the template given in IEC 61918:2013, Table 10 Table C.4 – Relationship between FOC and fibre types (CP 11/3) Fibre type FOC 10/125 µm single mode silica 50/125 µm multimode silica 62,5/125 µm multimode silica 980/1 000 µm step index POF 200/230 µm step index hard clad silica Others BFOC/2,5 No No No No No No SC No No No No No No SC-RJ No No No No No No LC Yes No No No No No F-SMA No No No No No No C.4.4.2.6 Specific requirements for CPs Not applicable C.4.4.2.7 Specific requirements for generic cabling in accordance with ISO/IEC 24702 C.4.4.3 Connections within a channel/permanent link C.4.4.4 Terminators Subclause 4.4.4.2 is not applicable BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 C.4.4.5 – 39 – Device location and connection Subclause 4.4.5.2 is not applicable C.4.4.6 Coding and labelling Subclause 4.4.6.3 has addition: The planner shall request to use redundancy cables of different colours and identify each of the two cables with labelling C.4.4.7 Earthing and bonding of equipment and devices and shielded cabling C.4.4.7.1 Common description C.4.4.7.2 Bonding and earthing of enclosures and pathways C.4.4.7.3 Earthing methods C.4.4.7.4 Shield earthing Subclause 4.4.7.4.1 is not applicable Subclause 4.4.7.4.2 is not applicable Subclause 4.4.7.4.3 has addition: The communication shields shall be directly earthed at the one end of the channel (see IEC 61918:2013, Figure 35) C.4.4.7.5 Specific requirements for CPs Not applicable C.4.4.7.6 C.4.4.8 Specific requirements for generic cabling in accordance with ISO/IEC 24702 Storage and transportation of cables Subclause 4.4.8.2 is not applicable C.4.4.9 Routing of cables C.4.4.10 Separation of circuit C.4.4.11 Mechanical protection of cabling components Subclause 4.4.11.2 is not applicable C.4.4.12 Installation in special areas Subclause 4.4.12.2 is not applicable C.4.5 Cabling planning documentation C.4.6 Verification of cabling planning specification – 40 – C.5 BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 Installation implementation C.5.1 General requirements C.5.2 Cable installation C.5.2.1 General requirements for all cabling types Subclause 5.2.1.2 has replacement: Table C.5 provides values based on the template given in IEC 61918:2013, Table 19 Table C.5 – Parameters for silica optical fibre cables Characteristic Minimum bending radius, single bending (mm) Mechanical Bending radius, multiple bending (mm) force Pull forces (N) a Value 170 (after installation) 340 (during installation) ≥ 170 – a Permanent tensile forces (N) – a Maximum lateral forces (N/cm) – a Temperature range during installation (°C) – a Depending on cable type; see manufacturer’s data sheet C.5.2.2 Installation and routing C.5.2.3 Specific requirements for CPs Not applicable C.5.2.4 Specific requirements for wireless installation Not applicable C.5.2.5 C.5.3 Specific requirements for generic cabling in accordance with ISO/IEC 24702 Connector installation Subclause 5.3.4 is not applicable C.5.4 Terminator installation Subclause 5.4.2 is not applicable C.5.5 Device installation Subclause 5.5.2 is not applicable C.5.6 Coding and labelling Subclause 5.6.2 is not applicable C.5.7 Earthing and bonding of equipment and devices and shield cabling Subclause 5.7.5 is not applicable BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 C.5.8 C.6 – 41 – As-implemented cabling documentation Installation verification and installation acceptance test C.6.1 General C.6.2 Installation verification C.6.2.1 General C.6.2.2 Verification according to cabling planning documentation C.6.2.3 Verification of earthing and bonding Subclause 6.2.3.2 is not applicable C.6.2.4 Verification of shield earthing C.6.2.5 Verification of cabling system C.6.2.6 Cable selection verification Subclause 6.2.6.2 is not applicable C.6.2.7 Connector verification Subclause 6.2.7.2 is not applicable C.6.2.8 Connection verification C.6.2.9 Terminators verification Subclause 6.2.9.2 is not applicable C.6.2.10 Coding and labelling verification Subclause 6.2.10.2 is not applicable C.6.2.11 C.6.3 Verification report Installation acceptance test C.6.3.1 General C.6.3.2 Acceptance test of Ethernet-based cabling Subclause 6.3.2.2.2 is not applicable C.6.3.3 Acceptance test of non-Ethernet-based cabling Not applicable C.6.3.4 Specific requirements for wireless installation Not applicable – 42 – C.6.3.5 C.7 BS EN 61784-5-11:2013 61784-5-11 © IEC:2013 Acceptance test report Installation administration Subclause 7.8 is not applicable C.8 Installation maintenance and installation troubleshooting Subclause 8.4 is not applicable _ This page deliberately left blank NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW British Standards Institution (BSI) BSI is the national body responsible for preparing British Standards and other standards-related publications, information and services BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited About us Revisions We bring together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions Our British Standards and other publications are updated by amendment or revision The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process Organizations of all sizes and across all sectors choose standards to help them achieve their goals Information on standards We can provide you with the knowledge that your organization needs to succeed Find out more about British Standards by visiting our website at bsigroup.com/standards or contacting our Customer Services team or Knowledge Centre Buying standards You can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at bsigroup.com/shop, where hard copies can also be purchased If you need international and foreign standards from other Standards Development Organizations, hard copies can be ordered from our Customer Services team Subscriptions Our range of subscription services are designed to make using standards easier for you For further information on our subscription products go to bsigroup.com/subscriptions With British Standards Online (BSOL) you’ll have instant access to over 55,000 British and adopted European and international standards from your desktop It’s available 24/7 and is refreshed daily so you’ll always be up to date You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single copy and subscription format, by becoming a BSI Subscribing Member PLUS is an updating service exclusive to BSI Subscribing Members You will automatically receive the latest hard copy of your standards when they’re revised or replaced To find out more about becoming a BSI Subscribing Member and the benefits of membership, please visit bsigroup.com/shop With a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet Licences can cover as few or as many users as you wish With updates supplied as soon as they’re available, you can be sure your documentation is current For further information, email bsmusales@bsigroup.com BSI Group Headquarters 389 Chiswick High Road London W4 4AL UK We continually improve the quality of our products and services to benefit your business If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please inform the Knowledge Centre Copyright All the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that owns copyright in the information used (such as the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI Details and advice can be obtained from the Copyright & Licensing Department Useful Contacts: Customer Services Tel: +44 845 086 9001 Email (orders): orders@bsigroup.com Email (enquiries): cservices@bsigroup.com Subscriptions Tel: +44 845 086 9001 Email: subscriptions@bsigroup.com Knowledge Centre Tel: +44 20 8996 7004 Email: knowledgecentre@bsigroup.com Copyright & Licensing Tel: +44 20 8996 7070 Email: copyright@bsigroup.com