1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 60317 47 2014

14 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 14
Dung lượng 1,31 MB

Nội dung

BS EN 60317-47:2014 BSI Standards Publication Specifications for particular types of winding wires Part 47: Aromatic polyimide enamelled rectangular copper wire, class 240 BRITISH STANDARD BS EN 60317-47:2014 National foreword This British Standard is the UK implementation of EN 60317-47:2014 It is identical to IEC 60317-47:2013 It supersedes BS EN 60317-47:1997 which is withdrawn The UK participation in its preparation was entrusted to Technical Committee GEL/55, Winding wires A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © The British Standards Institution 2014 Published by BSI Standards Limited 2014 ISBN 978 580 75959 ICS 29.060.10 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 February 2014 Amendments/corrigenda issued since publication Date Text affected EN 60317-47 EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM February 2014 ICS 29.060.10 Supersedes EN 60317-47:1997 English version Specifications for particular types of winding wires Part 47: Aromatic polyimide enamelled rectangular copper wire, class 240 (IEC 60317-47:2013) Spécifications pour types particuliers de fils de bobinage Partie 47: Fil de section rectangulaire en cuivre émaillé avec polyimide aromatique, classe 240 (CEI 60317-47:2013) Technische Lieferbedingungen für bestimmte Typen von Wickeldrähten Teil 47: Flachdrähte aus Kupfer, lackisoliert mit aromatischen Polyimiden, Klasse 240 (IEC 60317-47:2013) This European Standard was approved by CENELEC on 2013-11-18 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels © 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members Ref No EN 60317-47:2014 E BS EN 60317-47:2014 EN 60317-47:2014 Foreword The text of document 55/1421/FDIS, future edition of IEC 60317-47, prepared by IEC/TC 55 "Winding wires" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60317-47:2014 The following dates are fixed: • latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-08-18 • latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2016-11-18 This document supersedes EN 60317-47:1997 EN 60317-47:2014 includes EN 60317-47:1997: the following significant technical changes with respect to – deletion of the “in some countries” statement in the scope; – new subclause containing general notes on winding wire, formerly a part of the scope; – new subclause containing requirements for appearance; – revision to the notes in Clause 19, Dielectric dissipation factor; – new Clause 23, Pin hole test This standard is to be read in conjunction with EN 60317-0-2:2014 The numbering of clauses in this standard is not continuous from Clauses 20 and 30 in order to reserve space for possible future wire requirements prior to those for wire packaging Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights Endorsement notice The text of the International Standard IEC 60317-47:2013 was approved by CENELEC as a European Standard without any modification In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60264 Series NOTE Harmonized as EN 60264 Series (not modified) IEC 60317 Series NOTE Harmonized as EN 60317 Series (not modified) IEC 60851 Series NOTE Harmonized as EN 60851 Series (not modified) BS EN 60317-47:2014 EN 60317-47:2014 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies Publication Year Title EN/HD IEC 60317-0-2 2013 Specifications for particular types EN 60317-0-2 of winding wires Part 0-2: General requirements - Enamelled rectangular copper wire Year 2014 BS EN 60317-47:2014 EN 60317-47:2014 –2– 60317-47 © IEC:2013 CONTENTS INTRODUCTION Scope Normative reference Terms, definitions, general notes, and appearance 3.1 3.2 Terms and definitions General notes 3.2.1 Methods of test 3.2.2 Winding wire 3.3 Appearance Dimensions Electrical resistance Elongation 7 Springiness Flexibility and adherence Heat shock 10 Cut-through 11 Resistance to abrasion 12 Resistance to solvents 13 Breakdown voltage 14 Continuity of insulation 15 Temperature index 16 Resistance to refrigerants 17 Solderability 18 Heat or solvent bonding 19 Dielectric dissipation factor 20 Resistance to transformer oil 21 Loss of mass 23 Pin hole test 30 Packaging Bibliography 60317-47 © IEC:2013 –5– BS EN 60317-47:2014 EN 60317-47:2014 INTRODUCTION This part of IEC 60317 is one of a series of standards which deals with insulated wires used for windings in electrical equipment The series has three groups describing: 1) Winding wires – Test methods (IEC 60851); 2) Specifications for particular types of winding wires (IEC 60317); 3) Packaging of winding wires (IEC 60264) BS EN 60317-47:2014 EN 60317-47:2014 –6– 60317-47 © IEC:2013 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES – Part 47: Aromatic polyimide enamelled rectangular copper wire, class 240 Scope This part of IEC 60317 specifies the requirements of enamelled rectangular copper winding wire of class 240 with a sole coating of aromatic polyimide resin The range of nominal conductor dimensions covered by this standard is: – width: 2,0 mm max 16,0 mm; – thickness: 0,80 mm max 5,60 mm Wires of grade and grade are included in this specification and apply to the complete range of conductors The specified combinations of width and thickness, as well as the specified width/thickness ratio, are given in IEC 60317-0-2 Normative reference The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies IEC 60317-0-2:2013, Specifications for particular types of winding wires – Part 0-2: General requirements – Enamelled rectangular copper wire Terms, definitions, general notes, and appearance 3.1 Terms and definitions Subclause 3.1 of IEC 60317-0-2:2013 applies 3.2 3.2.1 General notes Methods of test Subclause 3.2.1 of IEC 60317-0-2:2013 applies In case of inconsistencies between IEC 60317-0-2: 2013 and this standard, the latter shall prevail 3.2.2 Winding wire Class 240 is a thermal class that requires a minimum temperature index of 240 and heat shock temperature of at least 260 °C The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be used, and this will depend on many factors, including the type of equipment involved 60317-47 © IEC:2013 3.3 –7– BS EN 60317-47:2014 EN 60317-47:2014 Appearance Subclause 3.3 of IEC 60317-0-2:2013 applies Dimensions Clause of IEC 60317-0-2:2013 applies Electrical resistance Clause of IEC 60317-0-2:2013 applies Elongation Clause of IEC 60317-0-2:2013 applies Springiness Clause of IEC 60317-0-2:2013 applies Flexibility and adherence Clause of IEC 60317-0-2:2013 applies For 8.2, the wire for the adherence test shall be stretched by 10 % Heat shock Clause of IEC 60317-0-2:2013 applies The minimum heat shock temperature shall be 260 °C 10 Cut-through Clause 10 of IEC 60317-0-2:2013 applies 11 Resistance to abrasion Test inappropriate 12 Resistance to solvents Clause 12 of IEC 60317-0-2:2013 applies 13 Breakdown voltage Clause 13 of IEC 60317-0-2:2013 applies The elevated temperature shall be 240 °C BS EN 60317-47:2014 EN 60317-47:2014 –8– 60317-47 © IEC:2013 14 Continuity of insulation Test inappropriate 15 Temperature index Clause 15 of IEC 60317-0-2:2013 applies The minimum temperature index shall be 240 16 Resistance to refrigerants Test inappropriate 17 Solderability Test inappropriate 18 Heat or solvent bonding Test inappropriate 19 Dielectric dissipation factor The dielectric dissipation factor tan δ shall not exceed 60 × 10 –4 at a frequency of 000 Hz NOTE Test under consideration 20 Resistance to transformer oil Test appropriate, but no requirements specified 21 Loss of mass Test appropriate, but no requirements specified 23 Pin hole test Test inappropriate 30 Packaging Clause 30 of IEC 60317-0-2:2013 applies 60317-47 © IEC:2013 –9– Bibliography IEC 60264 (all parts), Packaging of winding wires IEC 60317 (all parts), Specifications for particular types of winding wires IEC 60851 (all parts), Winding wires – Test methods _ BS EN 60317-47:2014 EN 60317-47:2014 This page deliberately left blank This page deliberately left blank NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW British Standards Institution (BSI) BSI is the national body responsible for preparing British Standards and other standards-related publications, information and services BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited About us Revisions We bring together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions Our British Standards and other publications are updated by amendment or revision The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process Organizations of all sizes and across all sectors choose standards to help them achieve their goals Information on standards We can provide you with the knowledge that your organization needs to succeed Find out more about British Standards by visiting our website at bsigroup.com/standards or contacting our Customer Services team or Knowledge Centre Buying standards You can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at bsigroup.com/shop, where hard copies can also be purchased If you need international and foreign standards from other Standards Development Organizations, hard copies can be ordered from our Customer Services team Subscriptions Our range of subscription services are designed to make using standards easier for you For further information on our subscription products go to bsigroup.com/subscriptions With British Standards Online (BSOL) you’ll have instant access to over 55,000 British and adopted European and international standards from your desktop It’s available 24/7 and is refreshed daily so you’ll always be up to date You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single copy and subscription format, by becoming a BSI Subscribing Member PLUS is an updating service exclusive to BSI Subscribing Members You will automatically receive the latest hard copy of your standards when they’re revised or replaced To find out more about becoming a BSI Subscribing Member and the benefits of membership, please visit bsigroup.com/shop With a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet Licences can cover as few or as many users as you wish With updates supplied as soon as they’re available, you can be sure your documentation is current For further information, email bsmusales@bsigroup.com BSI Group Headquarters 389 Chiswick High Road London W4 4AL UK We continually improve the quality of our products and services to benefit your business If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please inform the Knowledge Centre Copyright All the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that owns copyright in the information used (such as the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI Details and advice can be obtained from the Copyright & Licensing Department Useful Contacts: Customer Services Tel: +44 845 086 9001 Email (orders): orders@bsigroup.com Email (enquiries): cservices@bsigroup.com Subscriptions Tel: +44 845 086 9001 Email: subscriptions@bsigroup.com Knowledge Centre Tel: +44 20 8996 7004 Email: knowledgecentre@bsigroup.com Copyright & Licensing Tel: +44 20 8996 7070 Email: copyright@bsigroup.com

Ngày đăng: 14/04/2023, 14:34

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN