1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 60076 16 2011

40 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

BS EN 60076-16:2011 BSI Standards Publication Power transformers Part 16: Transformers for wind turbines applications BRITISH STANDARD BS EN 60076-16:2011 National foreword This British Standard is the UK implementation of EN 60076-16:2011 It is identical to IEC 60076-16:2011 The UK participation in its preparation was entrusted to Technical Committee PEL/14, Power transformers A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © BSI 2011 ISBN 978 580 64167 ICS 29.180 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 November 2011 Amendments issued since publication Amd No Date Text affected BS EN 60076-16:2011 EUROPEAN STANDARD EN 60076-16 NORME EUROPÉENNE EUROPÄISCHE NORM October 2011 ICS 29.180 English version Power transformers Part 16: Transformers for wind turbines applications (IEC 60076-16:2011) Transformateurs de puissance Partie 16: Transformateurs pour applications éoliennes (CEI 60076-16:2011) Leistungstransformatoren Teil 16: Transformatoren für Windenergieanlagen-Anwendungen (IEC 60076-16:2011) This European Standard was approved by CENELEC on 2011-09-29 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels © 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members Ref No EN 60076-16:2011 E BS EN 60076-16:2011 EN 60076-16:2011 -2- Foreword The text of document 14/690/FDIS, future edition of IEC 60076-16, prepared by IEC/TC 14 "Power transformers", was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60076-16:2011 The following dates are fixed: • • latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement latest date by which the national standards conflicting with the document have to be withdrawn (dop) 2012-06-29 (dow) 2014-09-29 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights Endorsement notice The text of the International Standard IEC 60076-16:2011 was approved by CENELEC as a European Standard without any modification In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60071-1:2006 NOTE Harmonized as EN 60071-1:2006 (not modified) IEC 60071-2:1996 NOTE Harmonized as EN 60071-2:1997 (not modified) IEC 60137:2008 NOTE Harmonized as EN 60137:2008 (not modified) IEC 60270:2000 NOTE Harmonized as EN 60270:2001 (not modified) IEC 62271-100:2008 NOTE Harmonized as EN 62271-100:2009 (not modified) IEC 62271-202:2006 NOTE Harmonized as EN 62271-202:2007 (not modified) BS EN 60076-16:2011 EN 60076-16:2011 -3- Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies Publication Year Title EN/HD Year IEC 60076-1 2011 Power transformers Part 1: General EN 60076-1 2011 IEC 60076-2 2011 Power transformers EN 60076-2 Part 2: Temperature rise for liquid-immersed transformers 2011 IEC 60076-3 + corr December 2000 2000 Power transformers Part 3: Insulation levels, dielectric tests and external clearances in air EN 60076-3 2001 IEC 60076-5 2006 Power transformers Part 5: Ability to withstand short circuit EN 60076-5 2006 IEC 60076-7 2005 Power transformers Part 7: Loading guide for oil-immersed power transformers - IEC 60076-8 1997 Power transformers Part 8: Application guide - - IEC 60076-11 2004 Power transformers Part 11: Dry-type transformers EN 60076-11 2004 IEC 60076-12 2008 Power transformers Part 12: Loading guide for dry-type power transformers - - IEC 60076-13 2006 Power transformers Part 13: Self-protected liquid-filled transformers EN 60076-13 2006 IEC 61100 - Classification of insulating liquids according to fire point and net calorific value EN 61100 - IEC 61378-1 2011 Convertor transformers EN 61378-1 Part 1: Transformers for industrial applications 2011 IEC 61378-3 2006 Convertor transformers Part 3: Application guide - - IEC 61400-1 2005 Wind turbines Part 1: Design requirements EN 61400-1 2005 ISO 12944 Series Paints and varnishes - Corrosion protection of steel structures by protective paint systems - BS EN 60076-16:2011 –2– 60076-16 © IEC:2011 CONTENTS INTRODUCTION Scope Normative references Terms and definitions Service conditions 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 Normal service conditions Altitude Temperature of cooling air Content of harmonic currents in the transformer Wave-shape of supply voltage Transient over and under voltages Humidity and salinity 10 Special electrical and environmental conditions around the transformer 10 Level of vibration 11 Provision for unusual service conditions for transformers for wind turbine applications 11 4.11 Transportation and storage conditions 11 4.12 Corrosion protection 11 Electrical characteristics 11 5.1 Rated power 11 5.2 Highest voltage for equipment 11 5.3 Tappings 12 5.4 Connection group 12 5.5 Dimensioning of neutral terminal 12 5.6 Short circuit impedance 12 5.7 Insulation levels for high voltage and low voltage windings 12 5.8 Temperature rise guaranteed at rated conditions 12 5.9 Overload capability 13 5.10 Inrush current 13 5.11 Ability to withstand short circuit 13 5.12 Operation with forced cooling 13 Rating plate 13 Tests 13 7.1 7.2 7.3 7.4 List and classification of tests (routine, type and special tests) 13 Routine tests 13 Type tests 14 Special tests 14 7.4.1 General 14 7.4.2 Chopped wave test 14 7.4.3 Electrical resonance frequency test 14 7.4.4 Climatic tests 14 7.4.5 Environmental test E3 14 7.4.6 Fire behavior test 15 Annex A (informative) Calculation method and tables 16 Bibliography 36 BS EN 60076-16:2011 60076-16 © IEC:2011 –3– Figure A.1 – Heat dissipation in a natural ventilated room 17 Figure A.2 – Schematic diagram of power frequency current injection apparatus 30 Figure A.3 – Switched transformer winding voltage responses with capacitor injection 31 Figure A.4 – HV Injection test figure 32 Figure A.5 – Example of measurement device 33 Table – Insulation levels 10 Table A.1 – Impact of harmonics content on liquid-immersed transformer losses 23 Table A.2 – Impact of harmonics content on dry type transformers losses 26 Table A.3 – Example of voltage harmonic order 29 BS EN 60076-16:2011 –6– 60076-16 © IEC:2011 INTRODUCTION This part of IEC 60076 is intended to specify the additional requirements for the transformers for installation in wind turbine applications Wind turbines use generator step-up transformers to connect the turbines to a network These transformers can be installed in the nacelle or in the tower or outside close to the wind turbine This standard covers transformers for wind turbine applications or wind farms where the constraints on transformers exceed the requirement of the present IEC 60076 series The constraints are not often known or recognized by the transformer manufacturers, wind turbine manufacturers and operators and as a result the level of reliability of these transformers can be lower than those used for conventional applications The transformers for wind turbine applications are not included in the present list of IEC 60076 standard series The purpose of this standard is help to obtain the same level of reliability as transformers for more common applications This standard deals particularly with the effects of repeated high frequency transient overvoltages, electrical, environmental, thermal, loading, installation and maintenance conditions that are specific for wind turbines or wind farms On site measurements, investigations and observations in wind turbines have detected risks for some different kind of installations: – repeated high frequency transient over or under voltages in the range of kHz; – over and under frequency due to turbine control; – values of over voltage; – over voltage or under voltage coming from LV side; – high level of transient over voltages due to switching; – presence of partial discharge around the transformer; – harmonic contents current and voltage; – overloading under ambient conditions; – fast transient overload; – clearances not in compliance with the minimum prescribed; – installation conditions and connections; – restricted conditions of cooling; – water droplets; – humidity levels that exceed the maximum permissible values; – salt and dust pollution and extreme climatic conditions; – high levels of vibration; – mechanical stresses Therefore it is necessary to take into account in the design of the transformer the constraints of this application, or to define some protective devices to protect the transformer Additional or improved routine, type or special tests for these transformers have to be specified to be in compliance with the constraints on the network BS EN 60076-16:2011 60076-16 © IEC:2011 –7– POWER TRANSFORMERS – Part 16: Transformers for wind turbine applications Scope This part of IEC 60076 applies to dry-type and liquid-immersed transformers for rated power 100 kVA up to 10 000 kVA for wind turbine applications having a winding with highest voltage for equipment up to and including 36 kV and at least one winding operating at a voltage greater than 1,1 kV Transformers covered by this standard comply with the relevant requirements prescribed in the IEC 60076 standards Normative references The following referenced documents are indispensable for the application of this document For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies IEC 60076-1:2011, Power transformers – Part 1: General IEC 60076-2:2011, Power transformers – Part 2: Temperature rise for liquid-immersed transformers IEC 60076-3:2000, Power transformers – Part 3: Insulation levels, dielectric tests and external clearances in air IEC 60076-5:2006, Power transformers – Part 5: Ability to withstand short circuit IEC 60076-7:2005, Power transformers – Part 7: Loading guide for oil-immersed power transformers IEC 60076-8:1997, Power transformers – Application guide IEC 60076-11:2004, Power transformers – Part 11: Dry-type transformers IEC 60076-12:2008, Power transformers – Part 12: Loading guide for dry-type power transformers IEC 60076-13:2006, Power transformers – Part 13: Self-protected liquid-filled transformers IEC 61100, Classification of insulating liquids according to fire-point and net calorific value IEC 61378-1:2011, Converter transformers – Part 1: Transformers for industrial applications IEC 61378-3:2006, Converter transformers – Part 3: Application guide IEC 61400-1:2005, Wind turbines – Part 1: Design requirements BS EN 60076-16:2011 –8– 60076-16 © IEC:2011 ISO 12944 (all parts), Paints and varnishes – Corrosion protection of steel structures by protective paint systems Terms and definitions For the purposes of this document, the following terms and definitions apply 3.1 wind turbine transformer generator step up transformer connecting the wind turbine to the power collection network of the wind farm 3.2 tower part of the supporting structure of wind turbine on top of which the nacelle with generator and other equipments are located 3.3 nacelle housing that contains the drive-train and other elements on top of a horizontal-axis wind turbine tower 4.1 Service conditions Normal service conditions Unless otherwise stated in this standard, the service conditions in IEC 60076-11 and IEC 60076-1 apply 4.2 Altitude IEC 60076 series applies 4.3 Temperature of cooling air The installation of transformers inside an enclosure without active cooling systems increases the transformer temperature The purchaser shall specify the maximum cooling air temperatures if they are different from those stated in IEC 60076-2 The transformer shall be designed according to real ambient temperatures and installation real conditions as described by the purchaser at enquiry stage Clause A.1 provides considerations for transformers installed in a naturally ventilated area like at the rear of the nacelle or in a separate enclosure installed outside the tower and equipped with air inlet and outlet In case of transformer installed in the tower or in an enclosure where natural ventilation is not provided the formula in A.1 is not applicable For transformers operating under these conditions, the effects of air inlet and outlet, cooling conditions, efficiency of air cooling and ventilation shall be considered The purchaser shall prescribe the air ambient temperature and air flow inside the tower at the enquiry stage If no temperature or air flow is specified, an internal ambient temperature inside the tower of 10 K higher than external temperature shall be assumed and not limited air circulation around the transformers BS EN 60076-16:2011 – 24 – 60076-16 © IEC:2011 Mean winding temperature rise = 65 K Low voltage winding Calculated losses at fundamental current Ι R losses at 75 °C = 000 W Eddy losses (4 %) = 160 W Total losses at 75 °C = 000 + 160 = 160 W LV winding gradient = 18 K Stray losses = 320 W Calculated losses in service with non sinusoidal currents Ι R losses = 000 × (1,038 2) = 312 W Eddy losses = 160 × 3,808 = 609 W Total LV winding losses = 312 + 609 = 921 W Calculated LV winding gradient = 18 × (4 921/4 160) 0,5 × 1,6 = 20,6 K Total in service stray losses = 320 × 1,308 = 419 W High voltage winding Calculated losses at fundamental current Ι R losses at 75 °C= 300 W Eddy losses (12 %) = 636 W Total losses at 75 °C = 300 + 636 = 936 W HV winding gradient = 17 K Stray losses = 40 W Calculated losses in service with non sinusoidal currents Ι R losses = 300 × (1,038 2) = 710 W Eddy losses = 636 × 3,808 = 421 W Total HV winding losses = 710 + 421 = 131 W Calculated HV winding gradient = 17 × (8 131/5 936) 0,5 × 1,6 = 21,9 K BS EN 60076-16:2011 60076-16 © IEC:2011 – 25 – Total in service stray losses = 40 × 1,308 = 52 W Transformer total losses ( Ttl ) at fundamental current Ttl = no load losses ( NLl ) + total load losses ( Ll ) Ttl = 100 + 000 + 160 + 320 + 300 + 636 + 40 = 11 556 W Transformer Total losses Ttl s in service with non sinusoidal current Ttl s = 100 + 312 + 609 + 419 + 710 + 421 + 52 = 14 623 W pu increased top oil temperature rise with non sinusoidal currents TOi / Tor = (14 623/11 556) 0,8 = 1,21 (+21 %) Derating of the transformer shall be approximately: Permissible loading for the transformer = Rated power × (11 556/14 623) 0,5 Permissible loading for the transformer = Rated power × 0,89 Derating of the transformer shall be approximately 11 % A.2.12.2.2 Conclusion The 000 kVA transformer taken as an example is not appropriate for the service described and • transformer shall be designed with reduced winding temperatures and top oil temperature rises, or • purchaser has to select a transformer with a higher rated power (e.g 000/0,89 kVA), or • the transformer rated power is not adequate for such load profile and the user shall reduce transformer loading by a factor of 0,89 NOTE In the case where the (ohmic and eddy) losses are known in both LV and HV windings, then the specific losses of the considered winding should be considered for an accuracy value of derating based on winding hot spot BS EN 60076-16:2011 – 26 – A.2.12.3 A.2.12.3.1 60076-16 © IEC:2011 Example for a dry type transformer Calculation of the permissible loading of the transformer Table A.2 – Impact of harmonics content on dry type transformers losses Harmonic order (h) Magnitude (%) Ι h /I ( Ι h /I )² enhancement factor Eddy losses enhancement factor Stray losses enhancement factor 100 1 1,000 1,000 26,2 0,262 0,068 64 1,716 0,248 11,0 0,110 0,012 10 0,593 0,057 11 8,1 0,081 0,006 56 0,794 0,044 13 5,8 0,058 0,003 36 0,569 0,026 17 4,2 0,042 0,001 76 0,510 0,017 19 2,6 0,026 0,000 68 0,244 0,007 23 1,9 0,019 0,000 36 0,191 0,004 25 1,6 0,016 0,000 26 0,160 0,003 29 1,2 0,012 0,000 14 0,121 0,002 31 0,8 0,008 0,000 06 0,062 0,001 ∑ 1,093 5,960 1,412 RMS current THD 1,046 30,65 % THD is the total harmonic distortion rate (%) THD according to IEC 60076-1:2011, 3.13.2 Calculation of the equivalent current I r2 = h=n Σ I h2 h =1 I r2 = 1,093 K factor = PEL = 5,960 Pf Rated power = 000 kVA No load losses = 300 W Load losses at 120 °C = 11 000 W Frequency = 50 Hz Mean winding temperature rise = 100 K BS EN 60076-16:2011 60076-16 © IEC:2011 – 27 – Low voltage winding Calculated losses at fundamental current Ι R losses at 120 °C = 100 W Eddy losses (2,9 %) = 120 W Total losses at 120 °C = 100+120 = 220 W LV winding gradient = 100 K Stray losses = 320 W Calculated losses in service with non sinusoidal currents Ι R losses = 100 × (1,046) = 485 W Eddy losses = 120 × 5,959 = 715 W Total LV winding losses = 485 + 715 = 200 W Calculated LV winding gradient = 100 × ( 200 / 220 ) 0,5 × 1,6 = 118,1 K Total in service stray losses = 320 × 1,412 = 452 W High voltage winding Calculated losses at fundamental current Ι R losses at 120 °C= 000 W Eddy losses (7,5 %) = 450 W Total losses at 120 °C = 000 + 450 = 450 W HV winding gradient = 100 K Calculated losses in service with non sinusoidal currents Ι R losses = 000 × (1,046) = 563 W Eddy losses = 450 × 5,959 = 682 W Total HV winding losses = 563 + 682 = 245 W Calculated HV winding gradient = 100 × (9 245/6 450) 0,5 × 1,6 = 133,4 K Transformer total losses ( Ttl ) at fundamental current Ttl = no load losses ( Nll ) + total load losses ( Ll ) BS EN 60076-16:2011 – 28 – 60076-16 © IEC:2011 Ttl = 300 + 100 + 123 + 320 + 000 + 450 = 13 293 W Transformer total losses Ttl s in service with non sinusoidal currents Ttl s = 300 + 485 + 715 + 452 + 563 + 682 = 17 197 W Derating of transformer shall be approximately: Permissible loading for the transformer = Rated power × (13 293 /17 197) 0,5 Permissible loading for the transformer = Rated power × 0,88 Derating of transformer shall be approximately 12 % A.2.12.3.2 Conclusion The 000 kVA transformer taken as example is not appropriate for the service described and • transformer shall be designed with reduced winding temperatures, or • purchaser has to select a transformer with a higher rated power (eg 000/0,88 kVA), or • the transformer rated power is not adequate for such load profile and the user shall reduce transformer loading by a factor of 0,88 A.3 Effects of voltage harmonics The effect of this voltage distortion leads to an increasing of: – magnetic flux density; – no load losses; – no load current; – noise level; – magnetic core temperature; Bh: Flux density corresponding to harmonic h (T) Bn: Flux density at nominal voltage (T) Vh: Voltage harmonic components (V) V1: Rated voltage (V) BS EN 60076-16:2011 60076-16 © IEC:2011 – 29 – Table A.3 – Example of voltage harmonic order Harmonic order (h) Magnitude (%) Vh/V1 (Vh/V1)² Bh/Bn (Bh/Bn)² 100 1 1 0,04 0,001 0,02 0,000 16 0,16 0,025 0,053 333 0,002 844 44 0,06 0,003 0,015 0,000 225 20 0,2 0,04 0,04 0,001 6 0,02 0,000 0,003 333 1,1111 × 10 –5 11 0,11 0,012 0,015 714 0,000 246 94 0,02 0,000 0,002 0,000 006 25 5,8 0,058 0,003 36 0,006 444 4,1531 × 10 –5 10 4,2 0,042 0,001 76 0,004 0,000 017 64 11 2,6 0,026 0,000 68 0,002 364 5,5868 × 10 –6 13 1,9 0,019 0,000 36 0,001 462 2,1361 × 10 –6 15 1,6 0,016 0,000 26 0,001 067 1,1378 × 10 –6 29 1,2 0,012 0,000 14 0,000 414 1,7122 × 10 –7 31 0,8 0,008 0,000 06 0,000 258 6,6597 × 10 –8 Σ 1,090 RMS voltage 1,044 THD (voltage) 30,05 % RMS flux density 1,003 THD (flux density) 7,35 % 1,005 402 014 THD according to IEC60076-1:2011, 3.13.2 RMS voltage is the square root of the sum of (Vh/V1)² RMS flux density is the square root of the sum of (Bh/Bn)² The consequences of this high voltage distortion (THD

Ngày đăng: 14/04/2023, 14:32

Xem thêm:

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN