1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 50516 2 1 2011

44 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

BS EN 50516-2-1:2011 BSI Standards Publication Industrial connector sets and interconnect components to be used in optical fibre control and communication systems — Product specifications Part 2-1: Type ODVA PC industrial terminated on EN 60793-2-10 category A1a and A1b multimode fibre to meet the requirements of category I (industrial environments) as specified in EN 50173-1 and IEC 61753-1-3 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW raising standards worldwide™ BS EN 50516-2-1:2011 BRITISH STANDARD National foreword This British Standard is the UK implementation of EN 50516-2-1:2011 The UK participation in its preparation was entrusted to Technical Committee GEL/86/2, Fibre optic interconnecting devices and passive components A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © BSI 2011 ISBN 978 580 69383 ICS 33.040.50; 33.180.10; 33.180.20 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 November 2011 Amendments issued since publication Date Text affected BS EN 50516-2-1:2011 EUROPEAN STANDARD EN 50516-2-1 NORME EUROPÉENNE EUROPÄISCHE NORM November 2011 ICS 33.180.20 English version Industrial connector sets and interconnect components to be used in optical fibre control and communication systems Product specifications Part 2-1: Type ODVA PC industrial terminated on EN 60793-2-10 category A1a and A1b multimode fibre to meet the requirements of category I (industrial environments) as specified in EN 50173-1 and IEC 61753-1-3 Industrie-Steckverbindersätze und Verbindungsbauelemente für Lichtwellenleiter-Steuerungs- und Datenübertragungssysteme Produktnormen Teil 2-1: Industriesteckverbinder der Bauart ODVA-PC zum Anschluss an Mehrmodenfasern der Typen A1a und A1b nach EN 60793-2-10 für die Kategorie I (Industrieumgebung) nach den Festlegungen in EN 50173-1 und IEC 61753-1-3 This European Standard was approved by CENELEC on 2011-07-19 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels © 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members Ref No EN 50516-2-1:2011 E BS EN 50516-2-1:2011 EN 50516-2-1:2011 –2– Contents 1 Scope 7 2 1.1 Product definition 7 1.2 Intermateability 7 1.3 Operating environment 7 1.4 Reliability 7 1.5 Quality assurance 7 Normative references 7 3 Description 9 4 3.1 General 9 3.2 Plug 9 3.3 Adaptor 9 3.4 Materials 9 3.5 Dimensions 9 3.6 Colour and marking 10 Variants 11 5 4.1 Terminated plug 11 4.2 Adaptor 11 4.3 Identification of variants 11 Dimensional requirements 12 6 5.1 Outline dimensions 12 5.2 Mating face and other limit dimensions 15 Tests 23 7 6.1 Sample size 23 6.2 Test and measurement methods 24 6.3 Test sequence 24 6.4 Pass/fail criteria 24 Test report 24 8 Product qualification requirements 24 8.1 Dimensional and marking requirements 24 8.2 Optical performance requirements 25 8.3 Mechanical performance requirements 26 8.4 Environmental performance requirements 30 Annex A (informative) Attenuation against reference 33 A.1 Test details 33 A.2 Reference LC connector details 33 Annex B (normative) Sample size and product sourcing requirements 34 Annex C (normative) Requirements for launch condition (Encircled flux) 35 Annex D (informative) Details of environmental classification out of EN 50173-1 (MICE) 36 Annex E (informative) Details of sample construction 37 Annex F (informative) Patent statement concerning ODVA industrial connectors 38 Bibliography 40 –3– BS EN 50516-2-1:2011 EN 50516-2-1:2011 Figures Figure – Outline dimensions – Plug 12 Figure – Outline dimensions – Fixed adaptor 13 Figure – Cut out for fixed adaptor mounting Variant 01 13 Figure – Cut out for fixed adaptor mounting Variant 02 14 Figure – Plug mating face and other limit dimensions 15 Figure – Variant Bm2, LC connector interface 16 Figure – Ferrule endface geometry – After termination 17 Figure – Positioning of fibre core 17 Figure – Ferrule endface geometry – Allowable undercut 19 Figure 10 – Variant 01, fixed adapter 20 Figure 11 – Variant M 01, LC adapter interface 21 Figure 12 – Pin gauge for adaptor 23 Figure E.1 – Example of test specimen for Tests – 13 37 Figure E.2 – Example of test specimen for Tests 14 – 19 37 Tables Table – Preferred colour scheme 10 Table – Terminated plug – Plug variants 11 Table – Terminated plug – Adaptor variants 11 Table – Identification of plug variants 11 Table – Identification of adaptor variants 11 Table – Geometrical parameters 18 Table – Optical performance requirements 25 Table – Mechanical performance requirements 26 Table – Environmental performance requirements 30 Table A.1 – Attenuation measurement: Test details 33 Table B.1 – Sample size and product sourcing requirements 34 Table C.1 – Requirements for 50 µm fibre core diameter at 850 nm 35 Table D.1 36 BS EN 50516-2-1:2011 EN 50516-2-1:2011 –4– Foreword This European Standard was prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic interconnect, passive and connectorised components The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50516-2-1 on 2011-07-19 The following dates were fixed: – – latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-07-19 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-07-19 CENELEC draws attention to the fact that it is claimed that compliance with this document may involve the use of a patent concerning ODVA industrial connectors (see declaration in Annex F) All potential patent issues concerning this product are covered by IEC patent statement (see EN 61754-24-21) –5– BS EN 50516-2-1:2011 EN 50516-2-1:2011 Introduction CENELEC draws attention to the fact that it is claimed that compliance with this document may involve the use of a patent concerning ODVA industrial connectors given in Annex F CENELEC takes no position concerning the evidence, validity and scope of this patent right The holder of this patent right has assured CENELEC that he/she is willing to negotiate licences under reasonable and non-discriminatory terms and conditions with applicants throughout the world In this respect, the statement of the holder of this patent right is registered with CENELEC Information may be obtained from: The Siemon Company 101 Siemon Company Drive Watertown, CT 06795 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights other than those identified above CENELEC shall not be held responsible for identifying any or all such patent rights BS EN 50516-2-1:2011 EN 50516-2-1:2011 –6– Industrial connector sets and interconnect components to be used in optical fibre control and communication systems – Product specifications Part 2-1: Type ODVA PC industrial terminated on EN 60793-2-10 category A1a and A1b multimode fibre to meet the requirements of category I (industrial environments) as specified in EN 50173-1 and IEC 61753-1-3 Description Performance Coupling mechanism: Twist and lock with sealing Application: For the use in category I (industrial environment) Configuration: Plug / adaptor / with one side of the configuration having a seal and a protective shell Attenuation (random mate): Fibre category: EN 60793-2-10 Type A1a Bm Mean ≤ 0,35 dB and ≤ 0,60 dB for ≥ 97 % of measurements Cable type: See Table Return loss: 2m ≥ 20 dB Related documents: EN 50173-1 Information technology – Generic cabling systems – Part 1: General requirements EN 50173-3 Information technology – Generic cabling systems – Part 3: Industrial premises EN 60529 Degrees of protection provided by enclosures (IP Code) (IEC 60529) EN 60794-3 Optical fibre cables – Part 3: Sectional specification – Outdoor cables (IEC 60794-3) EN 61300 series Fibre optic interconnecting devices and passive components – Basic test and measurement procedures (IEC 61300 series) EN 61753-1 Fibre optic interconnecting devices and passive components performance standard – Part 1: General and guidance for performance standards (IEC 61753-1) EN 61754-20 IEC 61753-1-3 Fibre optic connector interfaces – Part 20: Type LC connector family (IEC 61754-20) 1) Fibre optic interconnecting devices and passive components – Performance standard – Part 1-3: General and guidance for single-mode fibre optic connector performance for harsh industrial operating conditions Outline and maximum dimensions: ODVA connector plug with protective shell in sealed adaptor 1) At draft stage –7– BS EN 50516-2-1:2011 EN 50516-2-1:2011 Scope 1.1 Product definition This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements that an ODVA connector terminated with cylindrical zirconia PC ferrules with one side protected by an industrial housing, an adaptor fitted with resilient alignment sleeve and patchcord shall meet in order for it to be categorised as an EN standard product The product is rated IP67 Since different variants are permitted, product marking details are given in 3.6 1.2 Intermateability Products conforming to the requirements of this specification will intermate and give the specified level of random attenuation and random return loss performance, provided that the same fibre type is used The intention is that this will be true irrespective of the manufacturing source(s) of the product 1.3 Operating environment The tests selected combined with the severities and durations, specified as Category I, are intended to reflect, although they not necessarily satisfy all the requirements of the boundary conditions of M3I3C3E3 1.4 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this specification does not guarantee the reliability of the product This should be predicted using a recognised reliability assessment programme 1.5 Quality assurance Compliance with this specification does not guarantee the manufacturing consistency of the product This should be maintained using a recognised quality assurance programme Normative references The following referenced documents are indispensable for the application of this document For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies EN 60068-2-60 Environmental testing – Part 2: Tests – Test Ke: Flowing mixed gas corrosion test (IEC 60068-2-60) EN 60529 Degrees of protection provided by enclosures (IP Code) (IEC 60529) EN 60874-1 Connectors for optical fibres and cables – Generic specification (IEC 60874-1) EN 61280-1-4 Fibre optic communication subsystem test procedures – Part 1-4: General communication subsystems – Light source encircled flux measurement method (IEC 61280-1-4) EN 61300-1 Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 1: General and guidance (IEC 61300-1) EN 61300-2-1 Part 2-1: Tests – Vibration (sinusoidal) (IEC 61300-2-1) EN 61300-2-2 Part 2-2: Tests – Mating durability (IEC 61300-2-2) EN 61300-2-4 Part 2-4: Tests – Fibre/cable retention (IEC 61300-2-4) EN 61300-2-5 Part 2-5: Tests – Torsion (IEC 61300-2-5) BS EN 50516-2-1:2011 EN 50516-2-1:2011 –8– EN 61300-2-6 Part 2-6: Tests – Tensile strength of coupling mechanism (IEC 61300-2-6) EN 61300-2-7 Part 2-7: Tests – Bending moment (IEC 61300-2-7) EN 61300-2-9 Part 2-9: Tests – Shock (IEC 61300-2-9) EN 61300-2-10 Part 2-10: Tests – Crush resistance (IEC 61300-2-10) EN 61300-2-12 Part 2-12: Tests – Impact (IEC 61300-2-12) EN 61300-2-22 Part 2-22: Tests – Change of temperature (IEC 61300-2-22) EN 61300-2-26 Part 2-26: Tests – Salt mist (IEC 61300-2-26) EN 61300-2-27 Part 2-27: Tests – Dust – Laminar flow (IEC 61300-2-27) EN 61300-2-34 Part 2-34: Tests – Resistance to solvents and contaminating fluids of interconnecting components and closures (IEC 61300-2-34) EN 61300-2-35 Part 2-35: Tests – Cable nutation (IEC 61300-2-35) EN 61300-2-46 Part 2-46: Tests – Damp heat cyclic (IEC 61300-2-46) EN 61300-3-1 Part 3-1: Examinations and measurements – Visual examination (IEC 61300-3-1) EN 61300-3-6 Part 3-6: Examinations and measurements – Return loss (IEC 61300-3-6) EN 61300-3-15 Part 3-15: Examinations and measurements – Dome eccentricity of a convex polished ferrule endface (IEC 61300-3-15) EN 61300-3-16 Part 3-16: Examinations and measurements – Endface radius of spherically polished ferrules (IEC 61300-3-16) EN 61300-3-23 Part 3-23: Examination and measurements – Fibre position relative to ferrule endface (IEC 61300-3-23) EN 61300-3-28 Part 3-28: Examinations and measurements – Transient loss (IEC 61300-3-28) EN 61300-3-34 Part 3-34: Examinations and measurements – Attenuation of random mated connectors (IEC 61300-3-34) EN 61300-3-35 Part 3-35: Examinations and measurements – Fibre optic connector endface visual and automated inspection (IEC 61300-3-35) EN 61754-20 Fibre optic connector interfaces – Part 20: Type LC connector family (IEC 61754-20) BS EN 50516-2-1:2011 EN 50516-2-1:2011 – 28 – Table – Mechanical performance requirements (continued) No Test Torsion Requirement Initial and final requirements: Attenuation: ≤ 0,75 dB Return loss: ≥ 20 dB Requirements during the test: Change in attenuation during the test: ≤ 0,20 dB The specimen has no mechanical damage after the test according to test Cable nutation Initial and final requirements: Attenuation: ≤ 0,75 dB Return loss: ≥ 20 dB Requirements during the test: Change in attenuation before during and after the test: ≤ 0,20 dB The specimen has no mechanical damage after the test according to test 10 Bending moment Initial and final requirements: Attenuation: ≤ 0,75 dB Return loss: ≥ 20 dB Requirements during the test: Change in attenuation during the test: ≤ 0,20 dB The specimen has no mechanical damage after the test according to test Details Method: EN 61300-2-5 Magnitude and rate of application of the load: 10 N at N/s No of cycles: 25 cycles ± 180° (not to exceed cable specification) Point of application of the load: 0,2 m from rear of plug body Specimen optically functioning: Yes Measurements required: Before, during (continuous) and after the test Sampling rate: Measurements shall be made after the load has been maintained at its maximum level for at least s Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: recovery period Method: EN 61300-2-35 Magnitude of the load: 10 N No of cycles: 100 cycles with 360° Point of application of the load: 0,2 m from rear of plug body Specimen optically functioning: Yes Measurements required: Before, during and after test Sampling rate: Max sampling interval shall be ms Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: recovery period Method: EN 61300-2-7 Magnitude of the load: 10 N smoothly applied Method of mounting: An adaptor shall be mounted rigidly to the mounting fixture Point of application of the load: 55 mm from the optical reference plane of the adaptor The load shall be applied in perpendicular axes of the connector housing orientation Duration: 30 s per axis Specimen optically functioning: Yes Measurements required: Before, during (continuous) and after the test Sampling rate: Measurements shall be made after the load has been maintained at its maximum level for at least s Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions BS EN 50516-2-1:2011 – 29 – EN 50516-2-1:2011 Table – Mechanical performance requirements (continued) No 11 Test Shock Requirement Initial and final requirements: Attenuation: ≤ 0,75 dB Return loss: ≥ 20 dB Method: EN 61300-2-9 Acceleration: 250 m/s Duration: ms Shape: Half sine pulse Requirements during the test: Change in attenuation during the test: ≤ 0,20 dB Number of axes: Directions: 3x2 Number of shocks: per direction Specimen optically functioning: Yes Measurements required: Before, during (continuous) and after the test Sampling rate: Measurements shall be made after the load has been maintained at its maximum level for at least s Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Method: EN 61300-2-10 Load: (750 ± 50) N Application area: 50 mm × 50 mm Location of the load: Centre of housing at 0° and 90° along the longitudinal axis Duration of the load: 60 s per location Specimen optically functioning: Yes Measurements required: Before, during (continuous) and after the test Sampling rate: Measurements shall be made after the load has been maintained at its maximum level for at least s Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions The specimen has no mechanical damage after the test according to test 12 Crush resistance Details Initial and final requirements: Attenuation: ≤ 0,75 dB Return loss: ≥ 20 dB Requirements during the test: Change in attenuation during the test: ≤ 0,20 dB The specimen has no mechanical damage after the test according to test BS EN 50516-2-1:2011 EN 50516-2-1:2011 – 30 – 8.4 Environmental performance requirements Table – Environmental performance requirements No 13 Test Change of temperature for connectors and patchcords Requirement Method: EN 61300-2-22 Low temperature: -40 °C High temperature: +70 °C Duration at temperature extreme: 3h Rate of change of temperature: °C/min Number of cycles: Specimen optically functioning: Yes Measurements required: Before, during (max interval 10 min) and after the test The specimen has no mechanical damage after the test according to test Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: h at normal ambient conditions Initial and final requirements: Attenuation: ≤ 0,75 dB Return loss: ≥ 20 dB Method: EN 61300-2-27 Dust type: Talc Dust particle size: d < 150 µm Dust concentration: (10,6 ± 7,1) g/m Requirements during the test: Change in attenuation during the test: ≤ 0,20 dB Duration of exposure: 10 Specimen optically functioning: Yes Measurements required: Before and after the test Preconditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: h at normal ambient conditions Method: EN 61300-2-46 Low temperature: (+25 ± 2) °C High temperature: (+55 ± 2) °C Humidity: (95 ± 3) % RH at the maximum temperature Duration of the cycle: 24 h Number of cycles: Specimen optically functioning: Yes Measurements required: Before, during (max interval 10 min) and after the test Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: h at normal ambient conditions Initial and final requirements: Attenuation: ≤ 0,75 dB Return loss: ≥ 20 dB Requirements during the test: Change in attenuation during the test: ≤ 0,2 dB for connectors and ≤ 0,5 dB when patchcords with both industrial connectors and the cable are in the climatic chamber 14 Dust The specimen has no mechanical damage after the test according to test 15 Damp heat, cyclic Details Initial and final requirements: Attenuation: ≤ 0,75 dB Return loss: ≥ 20 dB Requirements during the test: Change in attenuation during the test: ≤ 0,20 dB The specimen has no mechanical damage BS EN 50516-2-1:2011 – 31 – EN 50516-2-1:2011 Table – Environmental performance requirements (continued) No 16 Test Industrial atmosphere Requirement Method: EN 60068-2-60, Method Duration of exposure: 96 h Concentration: SO2: 500 ppb ± 100 ppb H2S: 100 ppb ± 20 ppb (at (25 ± 2) °C and 75 % RH) Stability of concentration (volume changes per hour): ppb – 10 ppb Specimen optically functioning: No Measurements required: Before and after the test Preconditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: h at normal ambient conditions Method: EN 61300-2-26 Atmosphere: Salt solution % NaCl, pH 6,5 – 7,2 Temperature: +35 °C Duration of exposure: 96 h Specimen optically functioning: No Measurements required: Before and after the test Preconditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: h at normal ambient conditions Initial and final requirements: Attenuation: ≤ 0,75 dB Return loss: ≥ 20 dB Method: EN 61300-2-34 Solvent: NaCl Mineral oil Soap Duration of exposure: 24 h The specimen has no mechanical damage Specimen optically functioning: No Measurements required: Before and after the test Preconditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure h at normal ambient conditions Initial and final requirements: Attenuation: ≤ 0,75 dB Return loss: ≥ 20 dB The specimen has no mechanical damage 17 Salt mist Initial and final requirements: Attenuation: ≤ 0,75 dB Return loss: ≥ 20 dB The specimen has no mechanical damage 18 Resistance to solvents and contaminating fluids Details 0,3 ppm at 30 °C 0,5 ppm at 70 °C × 10 ppm at 30 °C BS EN 50516-2-1:2011 EN 50516-2-1:2011 – 32 – Table – Environmental performance requirements (continued) No 19 Test Durability by water immersion Requirement Details Initial and final requirements: Attenuation: ≤ 0,75 dB Return loss: ≥ 20 dB Method: EN 60529 Depth: Sample shall be m below the surface of the water (IP67) Temperature of the water: (+25 ± 2) °C Requirements during the test: Change in attenuation during the test: ≤ 0,20 dB Duration of exposure: 30 Number of cycles: Specimen optically functioning: Yes Measurements required: Before, during and after the test Preconditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure h at normal ambient conditions The specimen has no mechanical damage BS EN 50516-2-1:2011 – 33 – EN 50516-2-1:2011 Annex A (informative) Attenuation against reference A.1 Test details Attenuation measurement tests against reference connectors (EN 61300-3-4) may be performed if quality conformance is required When these measurements are required, the following test details are valid Table A.1 – Attenuation measurement: Test details Test Attenuation Requirement Grade M: ≤ 0,3 dB (against reference connector) A.2 Details Method: EN 61300-3-4 Source type: LED Peak wavelength: (850 ± 30) nm Source stability: ≤ ± 0,05 dB over the measuring period or at least h Detector linearity: Within ± 0,05 dB over the dynamic range to be measured Launch fibre length: >3m Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Reference LC connector details Ferrule outer diameter 1,249 mm ± 0,000 mm Eccentricity of fibre core centre to ferrule centre ≤ 0,001 mm Deviation of axis of fibre to axis of ferrule ≤ 0,2° Core diameter ≥ 49,6 µm Dome offset of spherically polished ferrule endface ≤ 30 µm Visual examination of fibre endface with ×200 magnification No defects in core zone Attenuation between two reference plugs at 850 nm ≤ 0,10 dB Visual examination Every 50 matings BS EN 50516-2-1:2011 EN 50516-2-1:2011 – 34 – Annex B (normative) Sample size and product sourcing requirements Table B.1 – Sample size and product sourcing requirements No Test Sample size Source Plug Adaptor New n/a Visual examination n/a Visual inspection of polished end face 20 Attenuation (random mate) 20 10 New Return loss (random mate) 20 10 Test Vibration (sinusoidal) Test Mating durability Test Fibre/cable retention Test Strength of coupling mechanism Test Impact Test Torsion Test Cable nutation Test 10 Bending moment Test 11 Shock Test 12 Crush 4 Test 13 Change of temperature 4 Test 14 Dust 4 Test 15 Damp heat, cyclic 4 Test 16 Industrial atmosphere 4 Test 17 Salt mist 4 Test 18 Resistance to solvents and contaminating fluids 4 Test 19 Durability by water immersion 4 Test connector patchcord The above tests in Table B.1 are intended to be performed individually in any order on produced sources as defined Products from previous tests may used BS EN 50516-2-1:2011 – 35 – EN 50516-2-1:2011 Annex C (normative) Requirements for launch condition (Encircled flux) Table C.1 – Requirements for 50 µm fibre core diameter at 850 nm Radial offset µm EF lower bound EF upper bound 10 0,278 0,391 15 0,598 0,711 20 0,910 0,928 22 0,969 0,981 Encircled flux of the launch conditions is to be measured according EN 61280-1-4 BS EN 50516-2-1:2011 EN 50516-2-1:2011 – 36 – Annex D (informative) Details of environmental classification out of EN 50173-1 (MICE) Table D.1 – 37 – BS EN 50516-2-1:2011 EN 50516-2-1:2011 Annex E (informative) Details of sample construction simplex LC connectors ODVA adaptor Figure E.1 – Example of test specimen for Tests – 13 loop back 2x LC simplex connector sealed area ODVA adaptor NOTE The cable loop within the sealed area shall be at least of m length Loop bending radius should not be less than that required by the cable specification Figure E.2 – Example of test specimen for Tests 14 – 19 BS EN 50516-2-1:2011 EN 50516-2-1:2011 – 38 – Annex F (informative) Patent statement concerning ODVA industrial connectors – 39 – BS EN 50516-2-1:2011 EN 50516-2-1:2011 BS EN 50516-2-1:2011 EN 50516-2-1:2011 – 40 – Bibliography EN 50173-1 Information technology – Generic cabling systems – Part 1: General requirements EN 50173-3 Information technology – Generic cabling systems – Part 3: Industrial premises EN 50174-2 Information technology – Cabling installation – Part 2: Installation planning and practices inside buildings EN 60793-2-10 Optical fibres – Part 2-10: Product specifications – category A1 multimode fibres (IEC 60793-2-10) EN 60793-2-50 Optical fibres – Part 2-50: Product specifications – Sectional specification for class B single-mode fibres (IEC 60793-2-50) EN 60794-2-50 Optical fibre cables – Part 2-50: Indoor cables – Family specification for simplex and duplex cables for use in terminated cable assemblies (IEC 60794-2-50) EN 60794-3 Optical fibre cables – Part 3: Sectional specification – Outdoor cables (IEC 60794-3) EN 61300 (series) Fibre optic interconnecting devices and passive components – Basic test and measurement procedures (IEC 61300 series) EN 61300-2-17 Part 2-17: Tests – Cold (IEC 61300-2-17) EN 61300-2-18 Part 2-18: Tests – Dry heat – High temperature endurance (IEC 61300-2-18) EN 61300-3-4 Part 3-4: Examinations and measurements – Attenuation (IEC 61300-3-4) EN 61300-3-10 Part 3-10: Examinations and measurements – Gauge retention force (IEC 61300-3-10) EN 61300-3-42 Part 3-42: Examinations and measurements – Attenuation of single mode alignment sleeves and or adaptors with resilient alignment sleeves (IEC 61300-3-42) EN 61753-1 Fibre optic interconnecting devices and passive components performance standard – Part 1: General and guidance for performance standards (IEC 61753-1) EN 61754-24-21 Fibre optic interconnecting devices and passive components – Fibre optic connector interfaces – Part 24-21: Type SC-RJ connectors with protective housings based on IEC 61076-3-106, variant 06 (IEC 61754-24-21) EN 61755-1 Fibre optic connector optical interfaces – Part 1: Optical interfaces for single mode nondispersion shifted fibres – General and guidance (IEC 61755-1) EN 61755-2-1 Fibre optic connector optical interfaces – Part 2-1: Optical interface standard single mode non-angled physically contacting fibres (IEC 61755-2-1) EN 61755-3-1 Fibre optic connector optical interfaces – Part 3-1: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia PC ferrule, single mode fibre (IEC 61755-3-1) EN ISO 8015 2) At draft stage for 2) Fibre optic interconnecting devices and passive components – Connectors for optical fibres and cables – Part 19-1: Fibre optic patch cord connector type SC-PC (floating duplex) standard terminated on multimode fibre type A1a, A1b – Detail specification Fibre optic interconnecting devices and passive components – Performance standard – Part 1-3: General and guidance for single-mode fibre optic connector performance for harsh industrial operating conditions 2) specification Geometrical product specifications (GPS) – Fundamentals – Concepts, principles and rules (ISO 8015) IEC 60874-19-1 IEC 61753-1-3 Sectional This page deliberately left blank British Standards Institution (BSI) BSI is the independent national body responsible for preparing British Standards and other standards-related publications, information and services It presents the UK view on standards in Europe and at the international level It is incorporated by Royal Charter Revisions Information on standards British Standards are updated by amendment or revision Users of British Standards should make sure that they possess the latest amendments or editions It is the constant aim of BSI to improve the quality of our products and services We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001 BSI provides a wide range of information on national, European and international standards through its Knowledge Centre BSI offers Members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards Tel: +44 (0)20 8996 7669 Fax: +44 (0)20 8996 7001 Email: plus@bsigroup.com Buying standards You may buy PDF and hard copy versions of standards directly using a credit card from the BSI Shop on the website www.bsigroup.com/shop In addition all orders for BSI, international and foreign standards publications can be addressed to BSI Customer Services Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001 Email: orders@bsigroup.com In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested Tel: +44 (0)20 8996 7004 Fax: +44 (0)20 8996 7005 Email: knowledgecentre@bsigroup.com Various BSI electronic information services are also available which give details on all its products and services Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: info@bsigroup.com BSI Subscribing Members are kept up to date with standards developments and receive substantial discounts on the purchase price of standards For details of these and other benefits contact Membership Administration Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: membership@bsigroup.com Information regarding online access to British Standards via British Standards Online can be found at www.bsigroup.com/BSOL Further information about BSI is available on the BSI website at www.bsigroup.com/standards Copyright Copyright subsists in all BSI publications BSI also holds the copyright, in the UK, of the publications of the international standardization bodies Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI This does not preclude the free use, in the course of implementing the standard of necessary details such as symbols, and size, type or grade designations If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained Details and advice can be obtained from the Copyright & Licensing Manager Tel: +44 (0)20 8996 7070 Email: copyright@bsigroup.com BSI Group Headquarters 389 Chiswick High Road London W4 4AL UK Tel +44 (0)20 8996 9001 Fax +44 (0)20 8996 7001 www.bsigroup.com/standards raising standards worldwide™

Ngày đăng: 14/04/2023, 08:35

Xem thêm:

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN