1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 50565 2 2014

64 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Nội dung

BS EN 50565-2:2014 BSI Standards Publication Electric cables — Guide to use for cables with a rated voltage not exceeding 450/750 V (U0 / U) Part 2: Specific guidance related to EN 50525 cable types BRITISH STANDARD BS EN 50565-2:2014 National foreword This British Standard is the UK implementation of EN 50565-2:2014 It supersedes BS 7540-2:2005, which is withdrawn National Annex NA (informative) gives guidance on standard United Kingdom cable reference codes The UK participation in its preparation was entrusted by Technical Committee GEL/20, Electric cables, to Subcommittee GEL/20/17, Electric Cables - Low voltage A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © The British Standards Institution 2014 Published by BSI Standards Limited 2014 ISBN 978 580 77325 ICS 29.060.20 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2014 Amendments/corrigenda issued since publication Date Text affected BS EN 50565-2:2014 EN 50565-2 EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM April 2014 ICS 29.060.20 English version Electric cables Guide to use for cables with a rated voltage not exceeding 450/750 V (U0/U) Part 2: Specific guidance related to EN 50525 cable types Câbles électriques Guide d’emploi des câbles avec une tension assignée n'excédant pas 450/750 V (U0/U) Partie 2: Lignes directrices spécifiques concernant les types de câbles de l'EN 50525 Kabel und Leitungen Leitfaden für die Verwendung von Kabeln und isolierten Leitungen mit einer Nennspannung nicht über 450/750 V (U0/U) - Teil 2: Aufbaudaten und Einsatzbedingungen der Kabel- und Leitungsbauarten nach EN 50525 This European Standard was approved by CENELEC on 2014-02-17 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels © 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members Ref No EN 50565-2:2014 E BS EN 50565-2:2014 EN 50565-2:2014 Contents –2– Page Foreword Introduction Scope Normative references Terms and definitions Specific cable types Annex A (informative) Clarification of terms used in tables not defined elsewhere 54 Annex B (informative) Relationship between cable product standards, cable codes and this European Standard 56 Table 1A – Cables conforming to EN 50525-2-11 – Constructional details and limiting conditions Table 1B – Cables conforming to EN 50525-2-11 – Specific guidance for use 10 Table 2A – Cables conforming to EN 50525-2-12 – Constructional details and limiting conditions 11 Table 2B – Cables conforming to EN 50525-2-12 – Specific guidance for use 12 Table 3A – Cables conforming to EN 50525-2-21, Clauses and – Constructional details and limiting conditions 13 Table 3B – Cables conforming to EN 50525-2-21, Clauses and – Specific guidance for use 15 Table 4A – Cables conforming to EN 50525-2-21, Clauses 6, and – Constructional details and limiting conditions 16 Table 4B – Cables conforming to EN 50525-2-21, Clauses 6, and – Specific guidance for use 18 Table 5A – Cables conforming to EN 50525-2-22 – Constructional details and limiting conditions 20 Table 5B – Cables conforming to EN 50525-2-22 – Specific guidance for use 21 Table 6A – Cables conforming to EN 50525-2-31, Clause – Constructional details and limiting conditions 22 Table 6B – Cables conforming to EN 50525-2-31, Clause – Specific guidance for use 23 Table 7A – Cables conforming to EN 50525-2-31, Clause – Constructional details and limiting conditions 24 Table 7B – Cables conforming to EN 50525-2-31, Clause – Specific guidance for use 25 Table 8A – Cables conforming to EN 50525-2-41 – Constructional details and limiting conditions 26 Table 8B – Cables conforming to EN 50525-2-41 – Specific guidance for use 27 Table 9A – Cables conforming to EN 50525-2-42 – Constructional details and limiting conditions 28 Table 9B – Cables conforming to EN 50525-2-42 – Specific guidance for use 29 Table 10A – Cables conforming to EN 50525-2-51 – Constructional details and limiting conditions 30 Table 10B – Cables conforming to EN 50525-2-51 – Specific guidance for use 32 Table 11A – Cables conforming to EN 50525-2-71 – Constructional details and limiting conditions 33 –3– BS EN 50565-2:2014 EN 50565-2:2014 Table 11B – Cables conforming to EN 50525-2-71 – Specific guidance for use 34 Table 12A – Cables conforming to EN 50525-2-72 – Constructional details and limiting conditions 35 Table 12B – Cables conforming to EN 50525-2-72 – Specific guidance for use 36 Table 13A – Cables conforming to EN 50525-2-81 – Constructional details and limiting conditions 37 Table 13B – Cables conforming to EN 50525-2-81 – Specific guidance for use 38 Table 14A – Cables conforming to EN 50525-2-82 – Constructional details and limiting conditions 39 Table 14B – Cables conforming to EN 50525-2-82 – Specific guidance for use 40 Table 15A – Cables conforming to EN 50525-2-83 – Constructional details and limiting conditions 41 Table 15B – Cables conforming to EN 50525-2-83 – Specific guidance for use 43 Table 16A – Cables conforming to EN 50525-3-11 – Constructional details and limiting conditions 44 Table 16B – Cables conforming to EN 50525-3-11 – Specific guidance for use 46 Table 17A – Cables conforming to EN 50525-3-21 – Constructional details and limiting conditions 47 Table 17B – Cables conforming to EN 50525-3-21 – Specific guidance for use 49 Table 18A – Cables conforming to EN 50525-3-31 – Constructional details and limiting conditions 50 Table 18B – Cables conforming to EN 50525-3-31 – Specific guidance for use 51 Table 19A – Cables conforming to EN 50525-3-41 – Constructional details and limiting conditions 52 Table 19B – Cables conforming to EN 50525-3-41 – Guide to use 53 Table B.1 – Cross-reference by cable standard 56 Table B.2 – Cross-reference by harmonised cable code 58 BS EN 50565-2:2014 EN 50565-2:2014 –4– Foreword This document (EN 50565-2:2014) has been prepared by CLC/TC 20 "Electric cables" The following dates are fixed: • latest date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-02-17 • latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2017-02-17 This document together with Part supersedes HD 516 S2:1997 EN 50565-1:2014 and EN 50565-2:2014 includes the following significant technical changes with respect to HD 516 S2:1997: Both parts of EN 50565 refer to cable types specified in EN 50525, replacing the reference to the HD21 and HD22 cable types Part provides general recommendations and guidance, Part covers specific guidance for each cable type in EN 50525, like designation, constructional details, recommendations for installation, conditions and limits of operation, temperature limits and recommended use/suitability This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD 2006/95/EC) Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights –5– BS EN 50565-2:2014 EN 50565-2:2014 Introduction This European Standard provides guidance for equipment manufacturers, installers and endusers on the properties of low voltage electric cables, and the limitations that are deemed to be necessary in order to safeguard life, buildings, and goods It also gives a reasonable certainty on cable life time expectation relevant to its application, i.e the duration of acceptable performance considered as reasonable for a cable used in a fixed installation for the distribution of electricity in a building is more than that for flexible cable The information is given in the form of limiting values and is illustrated by examples, which are not exhaustive but which indicate ways by which safety can be obtained It is not possible to cover all the uses for which the installers or users may wish to use a specific type of cable The use other than the recommended ones could result in a lowering of safety and/or in a reduction in the expected life of the cable If a cable is intended to be used outside of the recommended uses, the cable manufacturer should be consulted for advice This European Standard is to be read in conjunction with EN 50565-1:2014, which gives general recommendations and guidance Additional information on installation practice is given in the HD 384/HD 60364 series of specifications, and national regulations/codes of practice BS EN 50565-2:2014 EN 50565-2:2014 –6– Scope This European Standard provides guidance to help installers, cabling designers and end users to understand the characteristics of electric cables with a rated voltage not exceeding 450/750 V ( U /U ) or equivalent d.c voltages, so that the cable can be selected, installed and operated in a safe way It is applicable to those cable types that are specified in EN 50525 (all parts) Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies EN 50525 (all parts), Electric cables – Low voltage energy cables of rated voltages up to and including 450/750 V ( U / U ) EN 50565-1:2014 , Electric cables – Guide to use for cables with a rated voltage not exceeding 450/750 V – Part 1: General guidance HD 384/HD 60364 (all parts), Electrical installations of buildings / Low-voltage electrical installations (IEC 60364, all parts) IEC 60050-461, International Electrotechnical Vocabulary – Electric cables Terms and definitions For the purposes of this document, the terms and definitions given in EN 50565-1:2014, IEC 60050-461 and HD 384/HD 60364 series apply Further information on the terms used in the following tables may be found in Annex A Specific cable types Specific guidance for each cable type is organised in tabular format There are two tables for each cable type a) b) Table A for each relevant cable shows: – harmonised designations, – constructional details for the cable, – recommendations for installation (fixed cable types) or conditions and limits of operation (flexible cables), – recommended temperature limits Table B for each relevant cables shows: – recommended use, – comments about limitations and suitability, –7– BS EN 50565-2:2014 EN 50565-2:2014 The information is given in the form of limiting values and is illustrated by examples, which are not exhaustive but which indicate ways by which safety can be obtained It is not possible to cover all the uses for which the installers or users may wish to use a specific type of cable The use other than the recommended ones could result in a lowering of safety and/or in a reduction in the expected life of the cable If a cable is intended to be used outside of the recommended uses, the cable manufacturer should be consulted for advice BS EN 50565-2:2014 EN 50565-2:2014 –8– Table 1A – Cables conforming to EN 50525-2-11 – Constructional details and limiting conditions Parameter Unit Clause 4.1 Clause 4.2 Clause 5.1 Clause 5.2 Clause 5.3 H03VV-F H03VVH2-F H05VV-F H05VVH2-F H03V2V2-F H03V2V2H2-F H05V2V2-F H05V2V2H2-F H05V2V2D3-F 300/300 300/300 300/500 300/500 300/300 300/300 300/500 300/500 300/500 5 5 5 5 to 2 to 2 to 2 to 0,75 to 0,75 to 1,5 0,75 Constructional details Nominal voltage rating V Conductor class Number of cores Cross-sectional area size range to mm 0,5 to 0,75 a 0,5 to 0,75 a 0,75 to 0,75 to 1,5 0,5 to a 0,75 0,5 to 0,75 a Duty Extra light + + + + + + + + + Light + + + + + + + + + Ordinary — — + + — — + + + Heavy — — — — — — — — — Condition AD1 + + + + + + + + + Condition AD2 — — + + — — + + + Condition AD6 — — — — — — — — — Condition AD7 — — — — — — — — — Condition AD8 — — — — — — — — — Corrosive or polluting substances condition AF3 — — + + — — + + + Impact condition AG2 — — — — — — — — — Vibrations condition AH3 — — — — — — — — — Intermittent and temporary periods of short duration — — + + — — + + + Permanent — — — — — — — — — Presence of water Outdoor use BS EN 50565-2:2014 EN 50565-2:2014 – 48 – Table 17A – Cables conforming to EN 50525-3-21 – Constructional details and limiting conditions (concluded) Parameter Unit Clause 4.1 Clause 4.2 H07ZZ-F H07ZZ-F Temperature Maximum conductor operating temperature normal °C 90 90 Maximum conductor operating temperature short circuit (Maximum allowable time s) °C 250 250 Maximum cable surface °C 80 80 Maximum storage °C 40 40 Minimum installation and handling °C -5 -5 Key “+” = Acceptable “—” = Not suitable a Where the manufacturer has demonstrated suitable UV protection, permanent outdoor usage is permitted b When installed in conduit or similar closed systems, the cable is suitable for use at voltages up to and including 000 V a.c or up to 750 V d.c to earth BS EN 50565-2:2014 EN 50565-2:2014 – 49 – Table 17B – Cables conforming to EN 50525-3-21 – Specific guidance for use Cable type Heavy duty flexible cable, insulated and sheathed with crosslinked polymer and having low emission of smoke and corrosive gases H07ZZ-F Clause reference Clause 4.1 Recommendation for use locations where a low level of emission of smoke and corrosive gases are required in case of fire or burning; Comments These cables are not intended to provide circuit integrity in case of fire use in industrial and agricultural workshops, building sites, for heavy duty applications and supplying industrial and agricultural machines and appliances where cables are subject to medium mechanical stresses (e.g heating plates, inspection lamps, electric tools such as drills, circular saws, and domestic electric tools) use in dry, humid or moist rooms; fixed installations e.g on rough-cast in temporary buildings and huts for accommodation purposes Heavy duty flexible cable, insulated and sheathed with crosslinked polymer and having low emission of smoke and corrosive gases H07ZZ-F Clause 4.2 As for EN 50525-3-21, 4.1 (above) In addition the cables are especially suitable for use as connection to machine tools As for EN 50525-3-21, 4.1 (above) BS EN 50565-2:2014 EN 50565-2:2014 – 50 – Table 18A – Cables conforming to EN 50525-3-31 – Constructional details and limiting conditions Parameter Unit Clause 4.1 Clause 4.2 Clause 4.3 Clause 4.4 H07Z1-U H07Z1-R H07Z1-K H05Z1-U H05Z1-R H05Z1-K 450/750 450/750 450/750 300/500 300/500 300/500 2 1 1 1 1,5 to 10 1,5 to 630 1,5 to 240 0,5 to 0,5 to 0,5 to + + + — — — a a Constructional details Nominal voltage rating V Conductor class Number of cores Cross-sectional area size range Method of installation mm c In conduit + + a In cable trunking + + + + In cable ducting + + + — — — In cable wiring of electric appliances and equipment + + + + + + 70 70 70 70 70 70 160 160 160 160 Temperature Maximum continuous conductor operating °C b Maximum conductor short circuit (Maximum allowable time s) °C 160 160 Maximum cable surface °C 70 70 70 70 70 70 Maximum storage °C 40 40 40 40 40 40 Minimum installation and handling °C 5 5 5 Key “+” = Acceptable “—” = Not suitable a Signalling and control circuit only b For conductor sizes above 300 mm2 this temperature is reduced to 140 °C c The presence of water in contact with cable is not acceptable BS EN 50565-2:2014 EN 50565-2:2014 – 51 – Table 18B – Cables conforming to EN 50525-3-31 – Specific guidance for use Cable type Clause reference Single core non-sheathed cables with halogen free thermoplastic insulation and low emission of smoke with rated voltage of 450/750 V H07Z1-U H07Z1-R Clause 4.1 Single core non-sheathed cables with halogen free thermoplastic insulation and low emission of smoke with rated voltage of 450/750 V H07Z1-K Clause 4.2 Comments locations where a low level of emission of smoke and corrosive gases are required in case of fire or burning; Suitable for fixed protected installation in, lighting and control gear for voltages up to and including 000 V a.c or up to 750 V d.c to earth installation in surface-mounted or embedded conduits, or similar closed systems Clause 4.3 Single core non-sheathed cables with halogen free thermoplastic insulation and low emission of smoke with rated voltage of 300/500 V H05Z1-U H05Z1-R Single core non-sheathed cables with halogen free thermoplastic insulation and low emission of smoke with rated voltage of 300/500 V H05Z1-K Recommendations for use Clause 4.4 Type cables are for use where special fire performance is necessary, or where local conditions or regulations require increased levels of public safety They are especially suitable where cables are installed in bunches locations where a low level of emission of smoke and corrosive gases are required in case of fire or burning; fixed protected installation inside appliances and in lighting fittings The defined tests for smoke and halogen free gases relates only to the cables, and not to cable and conduit together These cables are not intended to provide circuit integrity in case of fire The defined tests for smoke and halogen free gases relates only to the cables, and not to cable and conduit together The cables are suitable for installation in surface-mounted or embedded conduits when used only for signalling or control circuits These cables are not intended to provide circuit integrity in case of fire BS EN 50565-2:2014 EN 50565-2:2014 – 52 – Table 19A – Cables conforming to EN 50525-3-41 – Constructional details and limiting conditions Parameter Unit Clause 4.1 Clause 4.2 Clause 4.3 Clause 4.4 H07Z-U H07Z-R H07Z-K H05Z-U H05Z-K 450/750 450/750 450/750 300/500 300/500 5 1 1 1,5 to 10 1,5 to 630 1,5 to 240 0,5 to 0,5 to + + + — — a Constructional details Nominal voltage rating V Conductor class Number of cores Cross-sectional area size range Method of installation mm b In conduit + a In cable trunking + + + + In cable ducting + + + — — In cable wiring of electric appliances and equipment + + + + + Temperature Maximum continuous conductor operating °C 90 90 90 90 90 Maximum conductor short circuit (Maximum allowable time s) °C 250 250 250 250 250 Maximum cable surface °C 90 90 90 90 90 Maximum storage °C 40 40 40 40 40 Minimum installation and handling °C -5 -5 -5 -5 -5 Key “+” = Acceptable “—” = Not suitable a Signalling and control circuit only b The presence of water in contact with cable is not acceptable – 53 – BS EN 50565-2:2014 EN 50565-2:2014 Table 19B – Cables conforming to EN 50525-3-41 – Guide to use Cable type Clause reference Single core non-sheathed halogen free cables with cross-linked insulation and low emission of smoke with rated voltage 450/750 V H07Z-U H07Z-R Clause 4.1 Single core non-sheathed halogen free cables with cross-linked insulation and low emission of smoke with rated voltage 450/750 V H07Z-K Clause 4.2 Single core non-sheathed halogen free cables with cross-linked insulation and low emission of smoke with rated voltage 300/500 V H05Z-U H05Z-R Clause 4.3 Single core non-sheathed halogen free cables with cross-linked insulation and low emission of smoke with rated voltage 300/500 V H05Z-K Clause 4.4 Recommendations for use locations where a low level of emission of smoke and corrosive gases are required in case of fire or burning; installation in surface-mounted or embedded conduits, or similar closed systems Comments Suitable for fixed protected installation in, lighting and control gear for voltages up to and including 000 V a.c or up to 750 V d.c to earth The defined tests for smoke and halogen free gases relates only to the cables, and not to cable and conduit together These cables are not intended to provide circuit integrity in case of fire locations where a low level of emission of smoke and corrosive gases are required in case of fire or burning; installation inside appliances and in lighting fittings The cables are suitable for installation in surface-mounted or embedded conduits when used only for signalling or control circuits The defined tests for smoke and halogen free gases relates only to the cables, and not to cable and conduit together These cables are not intended to provide circuit integrity in case of fire BS EN 50565-2:2014 EN 50565-2:2014 – 54 – Annex A (informative) Clarification of terms used in tables not defined elsewhere A.1 Conductor classification Class 1: Solid conductor (-U) Class 2: Stranded conductor (-R) Class 5: Flexible stranded conductor (for fixed installation cables: -K; for flexible cables; -F) A.2 Classes of external influence A.2.1 General The terms covering, presence of water, presence of corrosive or polluting substances, impact/mechanical stress, vibration, presence of flora and/or mould growth, presence of fauna have all been extracted from HD 60364-5-51:2009 A.2.2 Presence of water AD1 Negligible Probability of presence of water is negligible Location in which the walls not generally show traces of water but may so for short periods, for example in the form of vapour which good ventilation dries rapidly AD2 Free falling drops Probability of vertically falling drops Location in which water vapour occasionally condenses as drops or where steam may occasionally be present AD6 Waves Possibility of water waves Seashore locations such as piers, beaches, quays, etc AD7 AD8 Immersion Submersion Locations which may be flooded and/or where the equipment is immersed as follows: – Equipment with a height of less than 850 mm is located in such a way that its lowest point is not more than 000 mm below the surface of the water – Equipment with a height equal to or greater than 850 mm is located in such a way that its highest point is not more than 150 mm below the surface of the water Possibility of permanent and total covering by water Locations such as swimming pools where electrical equipment is permanently and totally covered with water – 55 – A.2.3 Presence of corrosive or polluting substances AF3 Intermittent or accidental BS EN 50565-2:2014 EN 50565-2:2014 Intermittent or accidental subjection to corrosive or polluting substances being used or produced Locations where some chemicals products are handled in small quantities and where these products may come only accidentally into contact with electrical equipment; such as conditions are found in factory laboratories, other laboratories or in locations where hydrocarbons are used (boiler-rooms, garages, etc.) A.2.4 Impact/Mechanical stress AG2 Medium severity A.2.5 Vibration AH3 High severity Standard industrial equipment Industrial installations subject to severe conditions A.3 Maximum continuous conductor operating temperature The maximum continuous conductor operating temperature at which a particular cable shall operate also depends upon the limiting temperature of the other cables and accessories with which it is in contact A.4 Recommended use The only possible recommended use according to this guide, generally known, for which the cable has been designed for the safeguard of life and the lifetime expectation A.5 Recommended temperatures and recommendations for installation Values and specifications that, if respected, will ensure that the cable operates safely, and for the intended duration, in accordance with the design data BS EN 50565-2:2014 EN 50565-2:2014 – 56 – Annex B (informative) Relationship between cable product standards, cable codes and this European Standard Table B.1 identifies, for each cable product standard covered by this European Standard, the location of specific guidance for the cables covered Table B.1 – Cross-reference by cable standard Cable standard EN 50525-2-11 Harmonised cable code H03VV-F, H03VVH2-F Table no in this European Standard Tables 1A and 1B H05VV-F,H05VVH2-F H03V2V2-F, H03V2V2H2-F H05V2V2-F,H05V2V2H2-F H05V2V2D3-F EN 50525-2-12 H03VVH8-F, H03VVH2H8-F Tables 2A and 2B H05VVH8-F,H05VVH2H8-F EN 50525-2-21, H05RR-F, H05RN-F Tables 3A and 3B H07RN-F H07RN8-F EN 50525-2-21, H05BB-F, H07BB-F Tables 4A and 4B H05BN4-F, H07BN4-F H05BQ-F, H07BQ-F H05GG-F, H05GGH2-F EN 50525-2-22 H03RT-H Tables 5A and 5B EN 50525-2-31, H07V-U, H07V-R Tables 6A and 6B Clause H07V-K H05V-U, H05V-R H05V-K EN 50525-2-31, H07V2-U, H07V2-R Clause H07V2-K Tables 7A and 7B H05V2-U, H05V2-R H05V2-K EN 50525-2-41 H05S-U, H05S-K H03S-K H05SJ-U, H05SJ-K H05SS-K Tables 8A and 8B – 57 – BS EN 50565-2:2014 EN 50565-2:2014 Table B.1 – Cross-reference by cable standard (concluded) Cable standard EN 50525-2-42 Harmonised cable code H07G-U, H07G-R Table no in this European Standard Tables 9A and 9B H07G-K H05G-U, H05G-K EN 50525-2-51 H05VV5-F, H05VVC4V5-K Tables 10A and 10B EN 50525-2-71 H03VH-Y Tables 11A and 11B EN 50525-2-72 H03VH7H-Y Tables 12A and 12B EN 50525-2-81 H01N2-D, H01N2-E Tables 13A and 13B EN 50525-2-82 H03RN-F Tables 14A and 14B H05RN-F, H05RNH2-F EN 50525-2-83 H05SS-F, H05SST-F Tables 15A and 15B H05SSD3-F, H05SSD3T-F EN 50525-3-11 H03Z1Z1-F, H03Z1Z1H2-F Tables 16A and 16B H05Z1Z1-F, H05Z1Z1H2-F EN 50525-3-21 H07ZZ-F Tables 17A and 17B EN 50525-3-31 H07Z1-U,H07Z1-R Tables 18A and 18B H07Z1-K H05Z1-U, H05Z1-R H05Z1-K EN 50525-3-41 H07Z-U, H07Z-R H07Z-K H05Z-U, H05Z-K Tables 19A and 19B BS EN 50565-2:2014 EN 50565-2:2014 – 58 – Table B.2 identifies, for each cable code the location of specific guidance for the cables covered Table B.2 – Cross-reference by harmonised cable code Harmonised cable code Table no in this European Standard Cable specification number Harmonised cable code Table no in this European Standard Cable specification number H01N2-D 13 EN 50525-2-81 H05V2V2-F EN 50525-2-11 H01N2-E 13 EN 50525-2-81 H05V2V2H2-F EN 50525-2-11 H03RN-F 14 EN 50525-2-82 H05VVH8-F EN 50525-2-12 H03RT-H EN 50525-2-22 H05V-K EN 50525-2-31 H03S-K EN 50525-2-41 H05V-R EN 50525-2-31 H03V2V2-F EN 50525-2-11 H05V-U EN 50525-2-31 H03V2V2H2-F EN 50525-2-11 H05VV5-F 10 EN 50525-2-51 H03VH7H-Y 12 EN 50525-2-72 H05VVC4V5-K 10 EN 50525-2-51 H03VH-Y 11 EN 50525-2-71 H05VV-F EN 50525-2-11 H03VV-F EN 50525-2-11 H05VVH2-F EN 50525-2-11 H03VVH2-F EN 50525-2-11 H05VVH2H8-F EN 50525-2-12 H03VVH2H8-F EN 50525-2-12 H05Z1-K 18 EN 50525-3-31 H03VVH8-F EN 50525-2-12 H05Z1-R 18 EN 50525-3-31 H03Z1Z1-F 16 EN 50525-3-11 H05Z1-U 18 EN 50525-3-31 H03Z1Z1H2-F 16 EN 50525-3-11 H05Z1Z1-F 16 EN 50525-3-11 H05BB-F EN 50525-2-21 H05Z1Z1H2-F 16 EN 50525-3-11 H05BN4-F EN 50525-2-21 H05Z-K 19 EN 50525-3-41 H05BQ-F EN 50525-2-21 H05Z-U 19 EN 50525-3-41 H05GG-F EN 50525-2-21 H07BB-F EN 50525-2-21 H05GGH2-F EN 50525-2-21 H07BN4-F EN 50525-2-21 H05G-K EN 50525-2-42 H07BQ-7 EN 50525-2-21 H05G-U EN 50525-2-42 H07G-K EN 50525-2-42 H05RN-F EN 50525-2-21 H07G-R EN 50525-2-42 H05RN-F 14 EN 50525-2-82 H07G-U EN 50525-2-42 H05RNH2-F 14 EN 50525-2-82 H07RN8-F EN 50525-2-21 H05RR-F EN 50525-2-21 H07RN-F EN 50525-2-21 H05SJ-K EN 50525-2-41 H07V2-K EN 50525-2-31 H05SJ-U EN 50525-2-41 H07V2-R EN 50525-2-31 H05S-K EN 50525-2-41 H07V2-U EN 50525-2-31 H05SSD3-F 15 EN 50525-2-83 H07V-K EN 50525-2-31 H05SSD3T-F 15 EN 50525-2-83 H07V-R EN 50525-2-31 H05SS-F 15 EN 50525-2-83 H07V-U EN 50525-2-31 H05SS-K EN 50525-2-41 H07Z1-K 18 EN 50525-3-31 H05SST-F 15 EN 50525-2-83 H07Z1-R 18 EN 50525-3-31 H05S-U EN 50525-2-41 H07Z1-U 18 EN 50525-3-31 H05V2-K EN 50525-2-31 H07Z-K 19 EN 50525-3-41 H05V2-R EN 50525-2-31 H07Z-R 19 EN 50525-3-41 H05V2-U EN 50525-2-31 H07Z-U 19 EN 50525-3-41 H05V2V2D3-F EN 50525-2-11 H07ZZ-F 17 EN 50525-3-21 BS EN 50565-2:2014 National Annex NA (informative) Standard United Kingdom reference codes The United Kingdom has used its own cable reference system for many decades, as well as using the new European coding system As an aid to users of BS EN 50565-2, a cross-reference table follows in order to limit confusion in the future This table covers only those cables with a current UK cable code All other cable types covered by BS EN 50565-2 have only the relevant CENELEC code, which should be used for all identification purposes Table NA.1 – Cable types with a recognized UK cable code Table number BS EN number Clause number Harmonized code United Kingdom cable code Former BS number Former table number 50525-2-11 4.1 H03VV-F 218nY BS 6500 26 50525-2-11 4.1 H03VVH2-F 2192Y BS 6500 26 50525-2-11 4.2 H05VV-F 318nY BS 6500 27 50525-2-11 4.2 H05VVH2-F 3192Y BS 6500 27 50525-2-21 4.1 H05RR-F 318n BS 6500 12 50525-2-21 4.2 H05RN-F 318nP – – 50525-2-21 4.3 H07RN-F 638nP BS 7919 14 50525-2-21 4.4 H07RN-F 638nP BS 7919 15 50525-2-31 4.1 H07V-R 6491X BS 6004 4a 50525-2-31 4.1 H07V-U 6491X BS 6004 4a 50525-2-31 4.2 H07V-K 6491X BS 6004 4a 50525-2-31 4.3 H05V-R 2491X BS 6004 50525-2-31 4.3 H05V-U 2491X BS 6004 50525-2-31 4.4 H05V-K 2491X BS 6004 50525-2-31 5.1 H07V2-R 6491X HR BS 6004 11a 50525-2-31 5.1 H07V2-U 6491X HR BS 6004 11a 50525-2-31 5.2 H07V2-K 6491X HR BS 6004 11b 50525-2-31 5.3 H05V2-R 2491X HR BS 6004 12 50525-2-31 5.3 H05V2-U 2491X HR BS 6004 12 50525-2-31 5.4 H05V2-K 2491X HR BS 6004 12 14 50525-2-82 4.2 H05RN-F 318nP BS 6500 13 19 50525-3-41 4.1 H07Z-R 6491B BS 7211 3a 19 50525-3-41 4.1 H07Z-U 6491B BS 7211 3a 19 50525-3-41 4.2 H07Z-K 6491B BS 7211 3b 19 50525-3-41 4.3 H05Z-U 2491B BS 7211 4a 19 50525-3-41 4.4 H05Z-K 2491B BS 7211 4b This page deliberately set blank This page deliberately left blank NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW British Standards Institution (BSI) BSI is the national body responsible for preparing British Standards and other standards-related publications, information and services BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited About us Revisions We bring together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions Our British Standards and other publications are updated by amendment or revision The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process Organizations of all sizes and across all sectors choose standards to help them achieve their goals Information on standards We can provide you with the knowledge that your organization needs to succeed Find out more about British Standards by visiting our website at bsigroup.com/standards or contacting our Customer Services team or Knowledge Centre Buying standards You can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at bsigroup.com/shop, where hard copies can also be purchased If you need international and foreign standards from other Standards Development Organizations, hard copies can be ordered from our Customer Services team Subscriptions Our range of subscription services are designed to make using standards easier for you For further information on our subscription products go to bsigroup.com/subscriptions With British Standards Online (BSOL) you’ll have instant access to over 55,000 British and adopted European and international standards from your desktop It’s available 24/7 and is refreshed daily so you’ll always be up to date You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single copy and subscription format, by becoming a BSI Subscribing Member PLUS is an updating service exclusive to BSI Subscribing Members You will automatically receive the latest hard copy of your standards when they’re revised or replaced To find out more about becoming a BSI Subscribing Member and the benefits of membership, please visit bsigroup.com/shop With a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet Licences can cover as few or as many users as you wish With updates supplied as soon as they’re available, you can be sure your documentation is current For further information, email bsmusales@bsigroup.com BSI Group Headquarters 389 Chiswick High Road London W4 4AL UK We continually improve the quality of our products and services to benefit your business If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please inform the Knowledge Centre Copyright All the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that owns copyright in the information used (such as the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI Details and advice can be obtained from the Copyright & Licensing Department Useful Contacts: Customer Services Tel: +44 845 086 9001 Email (orders): orders@bsigroup.com Email (enquiries): cservices@bsigroup.com Subscriptions Tel: +44 845 086 9001 Email: subscriptions@bsigroup.com Knowledge Centre Tel: +44 20 8996 7004 Email: knowledgecentre@bsigroup.com Copyright & Licensing Tel: +44 20 8996 7070 Email: copyright@bsigroup.com

Ngày đăng: 14/04/2023, 08:35

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN