1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 50086 2 3 1996 (2002) scan

14 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Printing BRITISH STANDARD Specification for Conduit svstelTIS for ~ cable lTIanagelTIent Part 2 Particular requirements Section 2 3 Flexible conduit systerns The European Standard EN 50086 2 3 1995 wi[.]

BRITISH STANDARD BSEN 50086-2-3: 1996 Jnc011Jorating Amendment No.1 and Currigendutn l'1u Specification for Conduit svstelTIS for ~ cable lTIanagelTIent Part 2: Particular requirements Section 2.3: Flexible conduit systerns The European Standard EN 50086-2-3:1995 with the incorporation of amendment All:1998 has the status ofa British Standard This British Standard should be read in conjunction with BS EN 50086-1: 1994 ICS 29.120.10 ~~»~>:;~>-:;»-:;»-:;»», -'~»»»»»»»»>, ::~~::~~::::~'-'-"::::~::;:~::;:~: ]\"{J COI'YL"G WITHOUT BSI PEIUllSSI0l\" EXCEPT AS PEIUllTTED BY COI'YIUGHT LAW - :;»-:;»-:;>: "":'~::~~::~~::~~::: ;::::~::::~:::: BS EN 50086-2-3:1996 COllllnittees responsible for this British Standard The preparation of this British Standard was entrusted to Technical Committee PELf I 13, Cable management, upon which the following bodies were represented: ASTA Certification Services British Electrical Systems Association (BEAMA Ltd.) British Telecolll1IlUnicatiollS pIc Electrical Installation Equipinent ~v1anufaeturers'Association Electricity Association Gland Manufacturers' Technical Committee Institution of Electrical Engineers Institution oflncorporated Executive Engineers This British Standard, having been prepared under the direction of thl;; Elcetroteehnieal Sector Board was pnhlished under the aut110ri!y or t11C Standards Board and cornes into erlect on i5 Aprii i996 ,t;, !lSI 2() Fehruary 2002 Amcndmcnts issucd sincc public8.tion The tl11lowing BSI references relate to the \\'ork Oil th is standard: CO!l1!l1 i!lee re leren ee PELIi i3 Uratllor C0!l1!l1en[lJ2/04071 IX' ISBN 5XO 25529 X Amd.No Date Comments 10515 Jan uary 2000 Deletion frOlll i~->o.lllleX i~-".LA->o of A-deviations for Finland 13549 26 February 2002 Correction to title of standard Corrigendum No BS EN 50086-2-3:1996 Contents Committees responsible National foreword Foreword Text of EN 50086-2-3 ~: nST 2(, Pebruary 2002 Page Inside front cover 11 BS EN 50086-L-3:i 996 l~ ational foreword This British Standard has been prepared by Technical Committee PELII 13 and is the English language version of EN 50086-2-3: 1995, Conduit systemsfor cable fnunugefneni - Purl 2-3: Purliculur l~eljuirefnenl.";J(}/~jle.,\ihlec (}tuluii ,~:,.v,,,,'iefn ,·, including amendment All: 1998 and corrigendum February 200 I, published by the European Committee for Electrotechnical Standardization (CENELEC) This British Standard is to be read in conjunction with BS EN 50086-1: 1994 Spec(!icationfor conduit systemsfor cable management - Palt J: General requirements The references to Part I should be read as references to BS E1'"~ 50086-1: 1994 \vhich is the English language version ofE1'".J 50086-1: 1993 A British Standard does not purport to include all the necessary prOVISIons ofa contract Users of British Standards are responsible for their correct application Compiiancc with a British Standard docs not ofitscif confer immunity froll1 legal obligations Summary of pages This docmnent comprises a front cover, an inside front cover, pages i and ii, the EN title page, pages to 8, an inside back cover and a back cover The BST copyright notice displayed in this document indicates when the docurnent was last issued ii CBSI 26 February 2002 EUROPEAN STANDARD E~J 50086-2-3 Ivlay 1995 NORME E1JROPEENNE + All EUROP AISCHE NORM December 1998 res 29.120.10 Incorporating corrigendum February 2001 l)cscriptors: Electric 1.viring SystClTI, flexible condl1it Incchanical characteristics electrical characteristics, test English version Conduit systems for cable management Part 2-3: Particular requirements for flexible conduit systems (includes amendment A II: 1998) Systemes de conduits pour la gestion du Installationsrohrsysteme zum FLihren von cfrblage Partie 2-3: Regles particulieres pour les systemes de conduits souples (inclut l' amendement A 11: 1998) Leitungen fiir elektrische Energie und fur Information Teil 2-3: Besondere Anforderungen fur flexible Elektroinstallationsrohrsysteme (enthalt A.ndenmg All: 1998) This European Standard "vas approved by CE1'-~ELEC 011 1994-12-06 CEl'~ELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status ofa national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEJ'.~ELEC lnelnber This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CEI~ELEC lllenlber into its own language and notified to the Central Secretariat has the sanle status as the official versions CENELEC members are the national e!ectrotec!mica! committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom CENELEC EUiopean Committee [Oi Electiotechnical Standaidization Comite Europeen de l'Jorlnalisation Electrotechnique Europaisches Komitee ftir Elektrotechnische Normullg Ccntral Sccrctariat: ruc dc Stassart 35, B-l050 Brussels © 1995 Copyright reserved to CENELEC members Ref No EN 50086-2-3: i 995 + Al i:i 998 E EN 50086-2-3:1995 Foreword The following dates were fixed: latest date by which the existence of the a-rnenchnent has to be announced at national level latest date by which the amendment has to be implemented at national level by publication of an identical national standard or by endorsement This European Standard has been prepared by CENELEC Technical Committee TC 113, Cable Management Systems The text of the draft was submitted to the formal vote and was approved by CENELEC as E1'"~ 50086-2-3 on 1994-12-06 This Part 2-3 specifies particular requirements for flexible conduit syste!TIs A conduit systenl vvhich conlplles vvith this standard is deemed safe for use (doa) 1999-03-16 (dop) 1999-06-16 The following dates were fixed: Contents latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement ldop) 1995-12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 1996-12-0 I For products which have complied with the relevant national standard before 1996-12-01, as shown by the manufacturer or by a certification body, this previous standard !TIay continue to apply for production until 2001-12-01 This Part 2-3 supplements or modifies the corresponding clauses ofEN 50086-1: 1993, Conduit s:vstemsfor cable management - Part 1: General requirement~ Where a particular clause or sub-clause of Part is not mentioned in this Part 2-3, that clause or sub-clause applies as far as is reasonable Where this Part 2~3 states "addition", "lTIodification" or "replacement", the relevant text of Part I is to be adapted accordingly Sub-elauses, tables and figures which are in addition to those in Part are numbered starting with 101 Annexes which are in addition to those in Part ! are labelled AA, BB, etc Page Foreword Scope Normative references 3 Definitions General requirements General conditions for tests Classification Marking and docLUnentation Dimensimls Construction 10 Mechanical properties 11 Electrical properties 12 Thermal properties 13 Fire effects 14 External influences 15 Electromagnetic compati bility AnnexA Annex AA (infortnati ve) A-deviations Figure 101 - Flexing test apparatus Figure l02-Gauge for checking the minimum inside diameter after resistance to heat test Figure 103 -Assembly ofconduit and terminating fitting for bonding test 3 4 5 5 8 7 Foreword to amendment Ai i At the request of the Finnish electrotechnical committee, a draft for an amendment to El'-~ 50086-2-3: 1995 vvas subtnitted to the CENELEC members for acceptance in October 1998 The text of the draft was accepted by CENELEC as amendment A II to EN 50086-2-3: 1995 on 1998-12-16 :CBSI 26 February 2002 EN 50086-2-3:1995 Scope This clause of Part I is applicable, except as follows i~ ddi ti on: This standard specifies the TequireUlents for flexible conduit systeuls Conduit systems which are used as an integral part of other equipment also have to be tested according to the relevant standard for that equipnlent Normative references This clause of Part is applicable Definitions This clause of Part is applicable Genera requirements This clause of Part is applicable GeneraJ conditions for tests This clause of Part I is applicable Classification This clause of Part is applicable, except as follows 6.1.3.1, 6.1.3.2 and 6.1.3.3 are not applicable 71'v1arking and docunlentation This clause of Part is applicable, except as follows Addition: 7.1.101 The conduit shall be marked in accordance with 7.1 at regular intervals along its length of preferably m but not longer than m Where this is technically impractical, the mark shall be on a label attached to the product at each end Compliance il· checked by inl]7ectio11 7.1.102 The manufacturer shall document for the system the minimum inside diameter, the minimum bend radius and the classification in accordance with clause COn1j7/iance L) checked by' ins/JcctiOl1 Dimensions Rcplaccmcnt: 8.1 Threads shall comply with EN 60423 ClJn1}J!iance l:r;; checked h)/' mean.') qf the gauges slJcctfied in ElY 60423 8.2 The IIlllllmum inside diameter of the conduit system shall be declared by the manufacturer Compliance i, checked by measurement Construction This clause of Part I is applicable ~: nST 2(, Pebruary 2002 EN 50086-2-3:1995 10 Mechanical properties This clause of Part I is applicable, except as follows 10.1 Ivicchanical strength 10.1.1 Addition: NOTE Very light ilexible conduits should not be considered as providing adequate mechanical protection and should not be used \vithin the construction of buildings lOA Bending test This sub-clause of Part is not applicable 10.5 Flexing test 10 5.101 An assemhly of conduit with a terminating fitting, assemhled in accordance with the manufacturer's instructions, shall be subjected to a flexing test by means of the apparatus shown in Figure 10I 10.5.102 The test shall be made on six samples of conduit of an appropriate length Three of the samples shall be tested at the declared transport, permanent application and installation temperature in accordance with Table with a tolerance of±2 DC The other three sarnples shall be tested at the declared permanent application and installation temperature in accordance with Table with a tolerance of ±2°C 10.5.103 The smnple shall be fixed to the oscillating member by means ofthe terminating fitting as shown in Figure 101, sothat when the conduit is at the middle of its travel, the axis of the conduit is vertical and passes through the axis of the oscillation The apparatus with the sample shall be conditioned for h or until the sample has attained the declared temperature, whichever period is the longer 10.5.104 The oscillating member shall be moved backwards and forwards through a total angle of 180° divided equally about the vertical axis The assembly shall be subjected to 000 flexings at a rate of 40 ± fiexings per minute A flexing constitutes starting from the vertical position, one continuous cycle of lll0venlent of essentially sinusoidal fOlln 10.5.105 After the test, the sample shaH show no sign ofdisintegration, nor shaH there be any cracks visible to nonnal or corrected vision 'vvithout Inagnificatioll 10.6 Coiiapsc test This sub-clause of Part is not applicable 10.7 Terlsile strength This sub-clause of Part is applicable, except as foiiows 10.7.3 Replacement: For conduit systems where tensile strength is not declared, the tensile strength of the joint shall comply with classification I in Table 11 Electrical properties This clause of Part I is applicable, except as follows 1.5 Bonding lcsl Rcplaccment: A sample of conduit and terminating fitting shall be assembled in accordance with the manufacturer's Instructions and Figure 103 A current of25 A, having a ftequency of 50 Hz to 60 Hz, derived fronl an a.c source having a no-load voltage not exceeding 12 V, sha!! be passed through the assembly for I I ~ S, after which the voltage drop shall be measured between the points shown in Figure 103 and the resistal1ce calculated from the current and this voltage drop The resistance shall not exceed 0,05 Q Where special devices are required for the coupling ofconduit and terminating fitting, it shall be sufficient to remove the protective coating from the conduit, or the protective finish shall be removed in accordance with the manufacturer's instructions before the voltage is applied :CBSI 26 February 2002 EN 50086-2-3:1995 12 Thermal properties This clause of Part I is applicable, except as follows 12.2.4 Rcplaccrncnt: The load is then removed and immediately after its removal it shall be possible to pass the appropriate gauge, in accordance vvith Figure 102, through the conduit under its Ow'll weight and \vithout any initial speed, with the sample in the vertical position 13 Fire effects This clause of Part I is applicable 14 External influences This clause of Part is applicable, except as follovvs 14.1.1.2 AddItIOn: When tested for first numeral or 6, the assembly shall be tested as a category enclosure 14.1.2.2 Addition: When tested for second numeral or 4, the assembly shall be tested using the oscillating tube 15 Electromagnetic compatibility This clause of Part I is applicable ~: nST 2(, Pebruary 2002 EN 50086-2-3:1995 .-J-I_-~ ~ _ -. // I o,~ / / ,II , / n / I J ~+ I I ~ I \ ! i //8 / I ~,

Ngày đăng: 14/04/2023, 08:34

Xem thêm:

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN