1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 50377 13 3 2011

44 1 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

BS EN 50377-13-3:2011 BSI Standards Publication Connector sets and interconnect components to be used in optical fibre communication systems — Product specifications Part 13-3: Type LX.5-APC DUPLEX terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, with full zirconia ferrule category U NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW raising standards worldwide™ BS EN 50377-13-3:2011 BRITISH STANDARD National foreword This British Standard is the UK implementation of EN 50377-13-3:2011 The UK participation in its preparation was entrusted to Technical Committee GEL/86/2, Fibre optic interconnecting devices and passive components A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © BSI 2011 ISBN 978 580 64518 ICS 33.180.20 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2011 Amendments issued since publication Date Text affected BS EN 50377-13-3:2011 EUROPEAN STANDARD EN 50377-13-3 NORME EUROPÉENNE March 2011 EUROPÄISCHE NORM ICS 33.180.20 English version Connector sets and interconnect components to be used in optical fibre communication systems Product specifications Part 13-3: Type LX.5-APC DUPLEX terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, with full zirconia ferrule category U Jeux de connecteurs et composants d'interconnexion utiliser dans les systèmes de communication par fibres optiques Spécifications de produits Partie 13-3: Type LX.5-APC duplex raccordé sur des fibres unimodales de catégorie B1.1 et B1.3 de la CEI 60793-250, avec férule en zircone plein de catégorie U Steckverbindersätze und Verbindungsbauelemente für LichtwellenleiterDatenübertragungssysteme Produktnormen Teil 13-3: Bauart LX.5-APC-Duplex zum Anschluss an Einmodenfasern der Kategorien B1.1 und B1.3 nach IEC 60793-2-50 mit Zirkonium-Ferrule für die Kategorie U This European Standard was approved by CENELEC on 2011-01-02 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels © 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members Ref No EN 50377-13-3:2011 E BS EN 50377-13-3:2011 EN 50377-13-3:2011 –2– Foreword This European Standard was prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic interconnect, passive and connectorised components The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50377-13-3 on 2011-01-02 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CEN and CENELEC shall not be held responsible for identifying any or all such patent rights The following dates were fixed: – – latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-01-02 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-01-02 BS EN 50377-13-3:2011 –3– EN 50377-13-3:2011 Connector sets and interconnect components to be used in optical fibre communication systems – Product specifications Part 13-3: Type LX.5-APC DUPLEX terminated on IEC 60793-2-50 category B1.1 and B1.3 singlemode fibre, with full zirconia ferrule category U Description Performance Coupling mechanism: Latched push-pull Application: For use in EN category U (Uncontrolled environment) Configuration: Plug/adaptor/plug Fibre category: EN 60793-2-50, Types B1.1 and B1.3 Attenuation grades: (random mate) B: ≤ 0,12 dB mean ≤ 0,25 dB for > 97 % of measurements Cable type: see Table C: ≤ 0,25 dB mean ≤ 0,50 dB for > 97 % of measurements Return loss grades: 1: ≥ 60 dB mated ≥ 55 dB unmated Related documents: EN 60794-2, Optical fibre cables – Part 2: Indoor cables – Sectional specification (IEC 60794-2) EN 61300 series, Fibre optic interconnecting devices and passive components – Basic test and measurement procedures (IEC 61300 series) EN 61753-1, Fibre optic interconnecting devices and passive components performance standard – Part 1: General and guidance for performance standards (IEC 61753-1) EN 61754-23, Fibre optic connector interfaces – Part 23: Type LX.5 connector family (IEC 61754-23) EN 61755-1, Fibre optic connector optical interfaces – Part 1: Optical interfaces for single mode non-dispersion shifted fibres – General and guidance (IEC 61755-1) EN 61755-3-2, Fibre optic connector optical interfaces – Part 3-2: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia ferrules for degrees angled-PC single mode fibres (IEC 61755-3-2) ETSI TS 100 671, Transmission and Multiplexing (TM); Passive optical components; Optical fibre connectors for single mode optical fibre communication systems; Common requirements and conformance testing Outline and maximum dimensions: 60 REF R30 0,9 66 REF R30 1,7 BS EN 50377-13-3:2011 EN 50377-13-3:2011 –4– Contents 1 Scope  2 1.1  Product definition  1.2  Intermateability  1.3  Operating environment  1.4  Reliability  1.5  Quality assurance  Normative references  3 Description  4 3.1  General  3.2  Plug  3.3  Duplex adaptor  3.4  Materials  3.5  Dimensions  3.6  Colour and marking  Variants  5 4.1  Terminated plug  4.2  Adaptor 10  Dimensional requirements 10  6 5.1  Outline dimensions 10  5.2  Mating face and other limit dimensions 13 Tests 24  7 6.1  6.2  6.3  6.4  Test 8 Performance requirements 25  8.1  8.2  8.3  8.4  Annex A Sample size 24  Test and measurement methods 25  Test sequence 25  Pass/Fail criteria 25  report 25  Dimensional and marking requirements 25 Optical performance requirements 26  Mechanical performance requirements 28  Environmental performance requirements 33  (informative) Attenuation against reference 35 Annex B (normative) Adaptor matched reference plug details 36 Annex C (normative) Sample size and product sourcing requirements 37 Annex D (informative) Zirconia ferrule response surface 38 Bibliography 39  BS EN 50377-13-3:2011 –5– EN 50377-13-3:2011 Figures Figure – Outline dimensions – Plug 11  Figure – Outline dimensions – Duplex adaptor 12 Figure – Mating face and other limit dimensions of plug connector interface 13  Figure – Ferrule end face geometry – After termination 17 Figure – Positioning of fibre core 18  Figure – Ferrule end face geometry – Allowable undercut 19 Figure – Requirements for the attenuation grades for the plug fibre core connected to the ideal reference 20  Figure – Adaptor mating face and other limit dimensions 21 Figure – Pin gauge for adaptor 24  Figure D.1 – Radius vs undercut and apex offset 38  Tables Table – Ensured level of random attenuation  Table – Preferred colour scheme  Table – Plug variants  Table – Adaptor variants 10  Table – Geometrical parameters 18  Table – Optical performance requirements 26  Table – Mechanical performance requirements 28 Table – Environmental performance requirements 33 Table – Environmental performance requirements 34 Table A.1 35  Table A.2 – Reference connector details 35  Table B.1 36  Table C.1 37  BS EN 50377-13-3:2011 EN 50377-13-3:2011 Scope 1.1 Product definition –6– This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which a terminated and assembled singlemode resilient alignment sleeve LX.5 APC connector set (plug/ adaptor/ plug) should meet in order for it to be categorised as an EN standard product Since different variants and grades of performance are permitted, product marking details are given in 3.6 1.2 Intermateability Although all products conforming to the requirements of this European Standard will intermate, the resulting level of random attenuation performance will only be ensured in accordance with Table The intention is that this will be true irrespective of the manufacturing source(s) of the product When intermating plug variants having different attenuation grades, the resulting level of attenuation cannot be assured to be any better than the worst attenuation grade The intermating of a grade C plug with a grade B plug will result in an uncertain level of random attenuation performance Table – Ensured level of random attenuation 1.3 Plug attenuation grade C B C C C B C B Operating environment The tests selected combined with the severities and durations are representative of a category U environment described in EN 61753-1 1.4 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this specification does not guarantee the reliability of the product This should be predicted using a recognised reliability assessment programme 1.5 Quality assurance Compliance with this specification does not guarantee the manufacturing consistency of the product This should be maintained using a recognised quality assurance programme BS EN 50377-13-3:2011 –7– EN 50377-13-3:2011 Normative references The following referenced documents are indispensable for the application of this document For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies EN 60793-2-50 Optical fibres – Part 2-50: Product specifications – Sectional specification for class B single-mode fibres (IEC 60793-2-50) EN 61300 (series) Fibre optic interconnecting devices and passive components – Basic test and measurement procedures (IEC 61300 series) EN 61300-2-1 Part 2-1: Tests – Vibration (sinusoidal) (IEC 61300-2-1) EN 61300-2-2 Part 2-2: Tests – Mating durability (IEC 61300-2-2) EN 61300-2-4 Part 2-4: Tests – Fibre/cable retention (IEC 61300-2-4) EN 61300-2-5 Part 2-5: Tests – Torsion/twist (IEC 61300-2-5) EN 61300-2-6 Part 2-6: Tests – Tensile strength of coupling mechanism (IEC 61300-2-6) EN 61300-2-7 Part 2-7: Tests – Bending moment (IEC 61300-2-7) EN 61300-2-12:2009 Part 2-12: Tests – Impact (IEC 61300-2-12:2009) EN 61300-2-17 Part 2-17: Tests – Cold (IEC 61300-2-17) EN 61300-2-18 Part 2-18: Tests – Dry heat – High temperature endurance (IEC 61300-2-18) EN 61300-2-22 Part 2-22: Tests – Change of temperature (IEC 61300-2-22) EN 61300-2-26 Part 2-26: Tests – Salt mist (IEC 61300-2-26) EN 61300-2-27 Part 2-27: Tests – Dust – Laminar flow (IEC 61300-2-27) EN 61300-2-42 Part 2-42: Tests – Static side load for connectors (IEC 61300-2-42) EN 61300-2-44 Part 2-44: Tests – Flexing of the strain relief of fibre optic devices (IEC 61300-2-44) EN 61300-2-46 Part 2-46: Tests – Damp heat cyclic (IEC 61300-2-46) EN 61300-3-6:2009 Part 3-6: Examinations and measurements – Return loss (IEC 61300-3-6:2008) EN 61300-3-10 Part 3-10: Examinations and measurements – Gauge retention force (IEC 61300-3-10) EN 61300-3-15 Part 3-15: Examinations and measurements – Dome eccentricity of a convex polished ferrule endface (IEC 61300-3-15) EN 61300-3-16 Part 3-16: Examinations and measurements – Endface radius of spherically polished ferrules (IEC 61300-3-16) EN 61300-3-23 Part 3-23: Examination and measurements – Fibre position relative to ferrule endface (IEC 61300-3-23) EN 61300-3-28 Part 3-28: Examinations and measurements – Transient loss (IEC 61300-3-28) EN 61300-3-34 Part 3-34: Examinations and measurements - Attenuation of random mated connectors (IEC 61300-3-34) EN 61300-3-42 Part 3-42: Examinations and measurements - Attenuation of single mode alignment sleeves and or adaptors with resilient alignment sleeves (IEC 61300-3-42) EN 61753-1 Fibre optic interconnecting devices and passive components performance standard – Part 1: General and guidance for performance standards (IEC 61753-1) EN 61754-23 Fibre optic connector interfaces – Part 23: Type LX.5 connector family (IEC 61754-23) ISO 8015 Technical drawings – Fundamental tolerancing principle BS EN 50377-13-3:2011 EN 50377-13-3:2011 Description 3.1 General –8– The LX.5 APC connector is a single position plug connector set of plug/ adaptor/ plug configuration characterised by cylindrical, spring loaded butting ferrules of 1,25 mm nominal diameter and a latched pushpull coupling mechanism The optical alignment mechanism of the connectors is of a resilient sleeve style 3.2 Plug The plug features a cylindrical zirconia ceramic ferrule and a latched push-pull mechanism It has a single male key which is used to limit and may be used to orientate, the relative rotation between mated connectors A cover (dustcap) to protect the ferrule endface is integrated in the connector 3.3 Duplex adaptor The adaptor has a zirconia ceramic resilient alignment sleeve Alternative materials may be used for the sleeve that have directly compatible material properties with zirconia, but the endface and performance requirements shall be met under all conditions The mounting style can be: a) square flange - hole fixing; b) square flange - clip fixing Covers (dustcaps) are integrated in each port of the adaptor 3.4 Materials Materials which are not specified or which are not specifically described are left to the discretion of the manufacturer 3.5 Dimensions Outline dimensions and other dimensions necessary to ensure intermateability or which affect performance are specified All other dimensions are left to the discretion of the manufacturer Where the mating face limit dimensions are not in agreement with an EN interface standard this is clearly stated 3.6 Colour and marking Marking of the product shall be in the following order of precedence: – identification of manufacturer; – manufacturing date code: year/week; – manufacturers part number; – variant identification number The following colour coding scheme is preferred BS EN 50377-13-3:2011 EN 50377-13-3:2011 8.3 – 28 – Mechanical performance requirements Table – Mechanical performance requirements No Test Vibration (sinusoidal) Requirement Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change Initial and final attenuation shall be ≤ specified for the grade Return loss: ≥ specified for the grade Mating durability Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change Initial and final attenuation shall be ≤ specified for the grade Details Method: EN 61300-2-1 Frequency range: 10 Hz to 55 Hz at octave/min Vibration amplitude: 0,75 mm Duration/axis: 30 No of axes: Specimen optically functioning: Yes Measurements required: Before, during and after test Sampling rate: Max sampling interval shall be ms (according to EN 61300-3-28) Pre-conditioning procedure: Clean plug and adaptor according to manufacturer’s instructions Method: EN 61300-2-2 Mechanism to be cycled: Plug-Adaptor Number of cycles: 500 (Only one plug is subjected to successive engagement and separation.) Not less than s between engagements Return loss: ≥ specified for the grade Specimen optically functioning: Yes Measurements required: After every mating Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Cleaning during test: In the event that the attenuation increases above or the return loss below the allowable limit the connector may be cleaned as necessary but not more than 25 times during the course of the test (The measurement at which the cleaning takes place shall be discounted from the test results.) BS EN 50377-13-3:2011 – 29 – EN 50377-13-3:2011 Table – Mechanical performance requirements (continued) No Test Fibre/cable retention Requirement Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change (Initial and final attenuation shall be within specified grade.) Return loss: ≥ 60 dB mated Details Method: EN 61300-2-4 Magnitude and rate of application of the tensile force: Var 01: (5 ± 0,5) N at 0,5 N/s Var 02: (70 ± 2) N at N/s Var 03 to 04: (100 ± 2) N at N/s Point of application of the load: Var 01: 0,3 m from plug Var 02 to 04 On strength member 0,3 m from plug The connector shall be rigidly mounted such that the load is applied to the fibre/cable retention mechanism and not to the coupling mechanism Strength of coupling mechanism Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change (Initial and final attenuation shall be within specified grade.) Return loss: ≥ 60 dB mated Duration of load: 120 s at 70 N and 100 N; 60 s at N Specimen optically functioning: Yes Measurements required: Before, during (continuous) and after the test (5 recovery period) Sampling rate: Measurements shall be made after the load has been maintained at its maximum level for at least 30 s Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Method: EN 61300-2-6 Magnitude of load: Var 02 to 04: 40 N Duration of the load: 120 s Rate of application of the load: N/s Point of application of the load: 0,3 m from rear of plug Specimen optically functioning: Yes Measurements required: Before, during and after the test (5 recovery period) Sampling rate: Measurements shall be made after the load has been maintained at its maximum level for at least 30 s Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions BS EN 50377-13-3:2011 EN 50377-13-3:2011 – 30 – Table – Mechanical performance requirements (continued) No Test Impact Requirement Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change (Initial and final attenuation shall be within specified grade.) Return loss: ≥ 60 dB mated Torsion Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change (Initial and final attenuation shall be within specified grade.) Return loss: ≥ 60 dB mated Details Method: EN 61300-2-12:2009, Method A Number of drops: Drop height: 1,5 m Specimen optically functioning: No (Specimen shall be unmated during impact test.) Measurements required: Before and after the test Pre-conditioning procedure: Fit dust cap Recovery procedure: Clean plug and adaptor according to manufacturer's instructions Method: EN 61300-2-5 Magnitude and rate of application of the load: Var 01: N at 0,1 N/s No of cycles: 25 cycles ± 180° (not to exceed cable specification) Point of application of the load: 0,2 m from rear of plug body Specimen optically functioning: Yes Measurements required: Before, during (continuous) and after the test Sampling rate: Measurements shall be made after the load has been maintained at its maximum level for at least s Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: recovery period Var 02 to 04: 15 N at N/s BS EN 50377-13-3:2011 – 31 – EN 50377-13-3:2011 Table – Mechanical performance requirements (continued) No 10 Test Flexing of the strain relief Requirement Method: EN 61300-2-44 Magnitude of the load: Var 02 to 04: 5N No of cycles: 100 cycles (± 90°) Point of application of the load: 0,2 m from rear of plug body Specimen optically functioning: Yes Measurements required: Before, during and after test Sampling rate: Max sampling interval shall be ms Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: recovery period Method: EN 61300-2-42 Magnitude of the load: Var 02 to 04: 1N (Initial and final attenuation shall be within specified grade.) Direction of the load: orthogonal axes 90° to fibre axis Point of application of the load: 0,2 m from rear of plug Return loss: Method of mounting: An adaptor shall be mounted rigidly to the mounting fixture Duration of load: Var 02* to 06*: 1h Specimen optically functioning: Yes Measurements required: Before, during (continuous) and after the test Sampling rate: max interval Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change before and after test ≤ 0,30 dB change during test (Initial and final attenuation shall be within specified grade.) Return loss: ≥ 60 dB mated 11 Static side load Details Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change ≥ 60 dB mated BS EN 50377-13-3:2011 EN 50377-13-3:2011 – 32 – Table – Mechanical performance requirements (continued) No 12 Test Bending moment Requirement Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change (Initial and final attenuation shall be within specified grade.) Return loss: ≥ 60 dB mated 13 Gauge retention force (measured on sleeve or adaptor) Allowable gauge retention force: 1,0 N – 2,5 N Details Method: EN 61300-2-7 Magnitude of the load: 10 N smoothly applied Point of application of the load: 25 mm from the centreline of the ferrule axis shown in Figure Method of mounting: An adaptor shall be mounted rigidly to the mounting fixture Specimen optically functioning: Yes Measurements required: Before, during (continuous) and after the test Sampling rate: Measurements shall be made after the load has been maintained at its maximum level for at least s Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Method: EN 61300-3-10 Gauge dimensions and characteristics: See Figure Pre-conditioning procedure: Clean gauge and sleeve or adaptor according to manufacturer's instructions BS EN 50377-13-3:2011 – 33 – 8.4 EN 50377-13-3:2011 Environmental performance requirements Table – Environmental performance requirements No 14 Test Cold Requirement Method: EN 61300-2-17 Temperature: - 25 °C Duration of exposure: 96 h Specimen optically functioning: Yes Measurements required: Before, during (max interval h) and after the test Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: h at normal ambient conditions Method: EN 61300-2-18 Temperature: + 70 °C Duration of exposure: 96 h Specimen optically functioning: Yes Measurements required: Before, during (max interval h) and after the test Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: h at normal ambient conditions Method: EN 61300-2-22 Low temperature: - 25 °C High temperature: + 70 °C Duration at temperature extreme: 1h Rate of change of temperature: °C/min Number of cycles: 12 Specimen optically functioning: Yes Measurements required: Before, during (max interval 10 min) and after the test Return loss: Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions ≥ 60 dB mated Recovery procedure: h at normal ambient conditions Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change (Initial and final attenuation shall be within specified grade.) Return loss: ≥ 60 dB mated 15 Dry heat Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change (Initial and final attenuation shall be within specified grade.) Return loss: ≥ 60 dB mated 16 Change of temperature for connectors and patchcords Details Attenuation at (1 550 ± 30) nm: ≤ 0,2 dB change for pigtails /connectors during and after ≤ 0,5 dB during and ≤ 0,4 after the test for m to m patchcords with both connectors and the cable in the climatic chamber Cable coil inside the chamber not smaller than 30 cm BS EN 50377-13-3:2011 EN 50377-13-3:2011 – 34 – Table – Environmental performance requirements No 17 Test Dust Requirement Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change (Initial and final attenuation shall be within specified grade.) Return loss: ≥ 60 dB mated 18 Salt mist Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change (Initial and final attenuation shall be within specified grade.) Return loss: ≥ 60 dB mated 19 Damp heat (cyclic) Attenuation at (1 550 ± 30) nm: ≤ 0,20 dB change (Initial and final attenuation shall be within specified grade.) Return loss: ≥ 60 dB mated Details Method: EN 61300-2-27 Dust type: Talc Dust particle size: d < 150 µm Dust concentration: (10,6 ± 7,1) g/m³ Duration of exposure: 10 Specimen optically functioning: No Measurements required: Before and after the test Preconditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: h at normal ambient conditions Method: EN 61300-2-26 Atmosphere: Salt solution % NaCl, pH 6,5 to 7,2 Temperature: + 35 °C Duration of exposure: 96 h Specimen optically functioning: No Measurements required: Before and after the test Preconditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: h at normal ambient conditions Method: EN 61300-2-46 High temperature: + 55 °C Low temperature: + 25 °C Relative humidity: > 95 % at low temperature and during temperature rise; > 90 % at high temperature Duration of cycle: 24 h Number of cycles: Specimen optically functioning: Yes Measurements required: Before, during (max interval 10 min) and after the test Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Recovery procedure: h at normal ambient conditions BS EN 50377-13-3:2011 – 35 – EN 50377-13-3:2011 Annex A (informative) Attenuation against reference Attenuation measurement tests against reference connectors (EN 61300-3-4) are intended to be performed should quality conformance be required When these measurements are required the following test details are valid Table A.1 Attenuation (against reference connector) Grade B: ≤ 0,25 dB Grade C: ≤ 0,5 dB Method: EN 61300-3-4:2001, Method B Source type: LED/LD Peak wavelength: (1 310 ± 30) nm and (1 550 ± 30) nm Source stability: ≤ ± 0,01 dB over the measuring period or at least h Detector linearity: Within ± 0,01 dB over the dynamic range to be measured Launch fibre length: > m – Only the fundamental mode shall propagate at the connector interface to be tested and at the detector Pre-conditioning procedure: Clean plug and adaptor according to manufacturer's instructions Table A.2 – Reference connector details Ferrule outer diameter (1,249 ± 0,000 5) mm Eccentricity of fibre core centre to ferrule centre ≤ 0,000 mm Deviation of axis of fibre to axis of ferrule ≤ 0,2° Dome Offset of spherically polished ferrule endface ≤ 30 µm Visual examination of fibre endface with × 200 magnification No defects in core zone Attenuation between two matched reference plugs in a reference adaptor in all eight measuring positions ≤ 0,03 dB Visual examination Every 50 matings BS EN 50377-13-3:2011 EN 50377-13-3:2011 – 36 – Annex B (normative) Adaptor matched reference plug details Table B.1 Ferrule outer diameter (1,249 ± 0,000 5) mm Eccentricity of fibre core centre to ferrule centre ≤ 0,000 mm Deviation of axis of fibre to axis of ferrule ≤ 0,2° Dome offset of spherically polished ferrule endface ≤ 30 µm Visual examination of fibre endface with × 200 magnification No defects in core zone Attenuation between two matched reference plugs in a reference adaptor in all eight measuring positions ≤ 0,03 dB Visual examination Every 50 matings The matched reference plug shall have the same geometrical characteristics as the plug under test and is selected from products meeting the requirements from Annex A The visual examination shall be repeated every 50 matings BS EN 50377-13-3:2011 – 37 – EN 50377-13-3:2011 Annex C (normative) Sample size and product sourcing requirements Table C.1 No Test Sample size Source Plug Adaptor NA Endface geometry all NA New and after all tests are completed NA Dimensional 5 New Adaptor performance (between matched reference plugs) NA 20 New Attenuation (random mate) 20 10 New Return loss (random mate) 10 10 Test Vibration (sinusoidal) Test Mating durability Test Fibre/cable retention Test Strength of coupling mechanism Test 15 Impact Test Torsion Test 10 Flexing Test 11 Static side load Test 12 Bending moment Test 13 Gauge retention force NA Test 14 Cold 2×4 Test 15 Dry heat 2×4 Test 16 Change of temperature 2×4 4 2×4 Test 17 Dust 2×4 Test 18 Salt mist 2×4 Test 19 Damp heat (cyclic) 2×4 Test pigtail patchcord The above tests are intended to be performed individually in any order on products sourced as defined Products from previous tests may be used BS EN 50377-13-3:2011 EN 50377-13-3:2011 – 38 – Annex D (informative) Zirconia ferrule response surface NOTE This graph is a qualitative representation only Figure D.1 – Radius vs undercut and apex offset BS EN 50377-13-3:2011 – 39 – EN 50377-13-3:2011 Bibliography EN 60794-2 Optical fibre cables – Part 2: Indoor cables – Sectional specification (IEC 60794-2) EN 60794-2-50 Optical fibre cables – Part 2-50: Indoor cables – Family specification for simplex and duplex cables for use in terminated cable assemblies (IEC 60794-2-50) EN 61300-3-4:2001 Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 3-4: Examinations and measurements – Attenuation (IEC 61300-3-4:2001) EN 61300-3-35 Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 3-35: Examinations and measurements – Fibre optic connector endface visual and automated inspection (IEC 61300-3-35) EN 61754-15 Fibre optic interconnecting devices and passive components – Fibre optic connector interfaces – Part 15: Type LSH connector family (IEC 61754-15) EN 61755-1 Fibre optic connector optical interfaces – Part 1: Optical interfaces for single mode non-dispersion shifted fibres – General and guidance (IEC 61755-1) EN 61755-2-2 Fibre optic connector optical interfaces – Part 2-2: Optical interface standard single mode angled physically contacting fibres (IEC 61755-2-2) EN 61755-3-2 Fibre optic connector optical interfaces – Part 3-2: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia ferrules for degrees angled-PC single mode fibres (IEC 61755-3-2) ETSI TS 100 671 Transmission and Multiplexing (TM); Passive optical components; Optical fibre connectors for single mode optical fibre communication systems; Common requirements and conformance testing This page deliberately left blank This page deliberately left blank British Standards Institution (BSI) BSI is the independent national body responsible for preparing British Standards and other standards-related publications, information and services It presents the UK view on standards in Europe and at the international level It is incorporated by Royal Charter Revisions Information on standards British Standards are updated by amendment or revision Users of British Standards should make sure that they possess the latest amendments or editions It is the constant aim of BSI to improve the quality of our products and services We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001 BSI provides a wide range of information on national, European and international standards through its Knowledge Centre BSI offers Members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards Tel: +44 (0)20 8996 7669 Fax: +44 (0)20 8996 7001 Email: plus@bsigroup.com Buying standards You may buy PDF and hard copy versions of standards directly using a credit card from the BSI Shop on the website www.bsigroup.com/shop In addition all orders for BSI, international and foreign standards publications can be addressed to BSI Customer Services Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001 Email: orders@bsigroup.com In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested Tel: +44 (0)20 8996 7004 Fax: +44 (0)20 8996 7005 Email: knowledgecentre@bsigroup.com Various BSI electronic information services are also available which give details on all its products and services Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: info@bsigroup.com BSI Subscribing Members are kept up to date with standards developments and receive substantial discounts on the purchase price of standards For details of these and other benefits contact Membership Administration Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: membership@bsigroup.com Information regarding online access to British Standards via British Standards Online can be found at www.bsigroup.com/BSOL Further information about BSI is available on the BSI website at www.bsigroup.com/standards Copyright Copyright subsists in all BSI publications BSI also holds the copyright, in the UK, of the publications of the international standardization bodies Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI This does not preclude the free use, in the course of implementing the standard of necessary details such as symbols, and size, type or grade designations If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained Details and advice can be obtained from the Copyright & Licensing Manager Tel: +44 (0)20 8996 7070 Email: copyright@bsigroup.com BSI Group Headquarters 389 Chiswick High Road London W4 4AL UK Tel +44 (0)20 8996 9001 Fax +44 (0)20 8996 7001 www.bsigroup.com/standards raising standards worldwide™

Ngày đăng: 14/04/2023, 08:32

Xem thêm:

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN