1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 13162 2012 + a1 2015

52 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 52
Dung lượng 1,45 MB

Nội dung

BS EN 13162:2012+A1:2015 BS EN 13162:2012 BSI Standards Publication Thermal insulation products for buildings — Factory made mineral wool (MW) products — Specification BS EN 13162:2012+A1:2015 BRITISH STANDARD National foreword This British Standard is the UK implementation of EN 13162:2012+A1:2015 It supersedes BS EN 13162:2012, which is withdrawn The start and finish of text introduced or altered by amendment is indicated in the text by tags Tags indicating changes to CEN text carry the number of the CEN amendment For example, text altered by CEN amendment A1 is indicated by  The UK participation in its preparation was entrusted to Technical Committee B/540, Energy performance of materials components and buildings A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © The British Standards Institution 2015 Published by BSI Standards Limited 2015 ISBN 978 580 86752 ICS 91.100.60 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 February 2013 Amendments/corrigenda issued since publication Date Text affected 31 March 2015 Implementation of CEN amendment A1:2015 EUROPEAN STANDARD EN 13162:2012+A1 NORME EUROPÉENNE EUROPÄISCHE NORM February 2015 ICS 91.100.60 Supersedes EN 13162:2012 English Version Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification Produits isolants thermiques pour le bâtiment - Produits manufacturés en laine minérale (MW) - Spécification Wärmedämmstoffe für Gebäude - Werkmäßig hergestellte Produkte aus Mineralwolle (MW) - Spezifikation This European Standard was approved by CEN on October 2012 and includes Amendment approved by CEN on 15 December 2014 CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels © 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members Ref No EN 13162:2012+A1:2015 E BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) Contents Page Foreword Scope Normative references Terms, definitions, symbols, units and abbreviated terms .8 Requirements 11 Test methods 18 Designation code 20 Assessment and Verification of the Constancy of Performance (AVCP) 21 Marking and labelling 22 Annex A (normative) Determination of the declared values of thermal resistance and thermal conductivity 23 Annex B (normative) !Product type determination" (!PTD") and factory production control (FPC) 26 Annex C (normative) MW multi-layered insulation products 31 Annex D (informative) Examples for the determination of the declared values of thermal resistance and thermal conductivity for a product or a product group 33 Annex ZA (informative) !Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation 36 Bibliography 47 Tables Table — Level and classes for thickness tolerances 12 Table — Dimensional stability under specified temperature and humidity conditions 14 Table — Classes for thickness tolerances 16 Table — Levels for compressibility 16 Table — Test methods, test specimens and conditions 19 Table A.1 — Values for k for one sided 90 % tolerance interval with a confidence level of 90 % 25 Table B.1 — Minimum number of tests for !PTD" and minimum product testing frequencies 26 Table B.2 — Minimum product testing frequencies for the reaction to fire characteristics 28 Table D.1 — λ test results 33 Table D.2 — R test results 34 Table ZA.1 — Relevant clauses for factory made mineral wool and intended use 36 Table ZA.2 — Systems of AVCP 38 Table ZA.3.1 — Assignment of AVCP tasks for factory made mineral wool products under system for reaction to fire and system (see Table ZA.2) 38 Table ZA.3.2 — Assignment of AVCP tasks for factory made mineral wool products under system (see Table ZA.2) 40 BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) Table ZA.3.3 — Assignment of AVCP tasks for factory made mineral wool products under combined system for reaction to fire and system (see Table ZA.2) 41 Figures Figure ZA.1 — Example CE marking information of products under AVCP system and system 3" 46 BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) Foreword This document (EN 13162:2012+A1:2015) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2015, and conflicting national standards shall be withdrawn at the latest by November 2016 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s) !For relationship with EU Construction Products Regulation (CPR), see informative Annex ZA, which is an integral part of this standard." This document includes Amendment approved by CEN on 2014-12-15 The start and finish of text introduced or altered by amendment is indicated in the text by tags !" This document supersedes !EN 13162:2012" Compared with EN 13162:2008, the main changes are: a) better harmonisation between the individual standards of the package (EN 13162 to EN 13171) on definitions, requirements, classes and levels; b) new normative annex on multi-layered products; c) changes of some editorial and technical content and addition of information on some specific items such as for MW: lamella, compressibility…; d) addition to links to EN 15715, Thermal insulation products — Instructions for mounting and fixing for reaction to fire testing — Factory made products; e) changes to Annex ZA !Amendment modifies EN 13162:2012 identifying those clauses of the standard which are needed for the compliance of the European Standard with the Construction Products Regulation (CPR) This amendment introduces f) an addition to the foreword; g) an addition in 3.2; h) an addition in 4.3.10.2; i) a new subclause 4.3.13; j) modification of Clause 7; k) modification of Clause 8; BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) l) modification of Annex B; m) a new Annex ZA." This standard is one of a series of standards for thermal insulation products used in buildings but this standard may be used in other areas where appropriate In pursuance of Resolution BT 20/1993 revised, CEN/TC 88 have proposed defining the standards listed below as a package of documents The package of standards comprises the following group of interrelated standards for the specifications of factory made thermal insulation products, all of which come within the scope of CEN/TC 88: EN 13162, Thermal insulation products for buildings — Factory made mineral wool (MW) products — Specification EN 13163, Thermal insulation products for buildings — Factory made expanded polystyrene (EPS) products — Specification EN 13164, Thermal insulation products for buildings — Factory made extruded polystyrene foam (XPS) products — Specification EN 13165, Thermal insulation products for buildings — Factory made rigid polyurethane foam (PU) products — Specification EN 13166, Thermal insulation products for buildings — Factory made phenolic foam (PF) products — Specification EN 13167, Thermal insulation products for buildings — Factory made cellular glass (CG) products — Specification EN 13168, Thermal insulation products for buildings — Factory made wood wool (WW) products — Specification EN 13169, Thermal insulation products for buildings — Factory made expanded perlite board (EPB) products — Specification EN 13170, Thermal insulation products for buildings — Factory made products of expanded cork (ICB) — Specification EN 13171, Thermal insulation products for buildings — Factory made wood fibre (WF) products — Specification The reduction in energy used and emissions produced during the installed life of insulation products exceeds by far the energy used and emissions made during the production and disposal processes According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) Scope This European Standard specifies the requirements for factory made mineral wool products, with or without facings or coatings, which are used for the thermal insulation of buildings The products are manufactured in the mat blankets, boards or slabs Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application The levels required for a given application are to be found in regulations or non-conflicting standards Products with a declared thermal resistance lower than 0,25 m2⋅K/W or a declared thermal conductivity greater than 0,060 W/(m⋅K) at 10 °C are not covered by this standard This standard does not cover in situ insulation products (covered by EN 14064 parts and 2) and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14303) Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies EN 822, Thermal insulating products for building applications — Determination of length and width EN 823, Thermal insulating products for building applications — Determination of thickness EN 824, Thermal insulating products for building applications — Determination of squareness EN 825, Thermal insulating products for building applications — Determination of flatness EN 826, Thermal insulating products for building applications — Determination of compression behaviour EN 1604, Thermal insulating products for building applications — Determination of dimensional stability under specified temperature and humidity conditions EN 1606, Thermal insulating products for building applications — Determination of compressive creep EN 1607, Thermal insulating products for building applications — Determination of tensile strength perpendicular to faces EN 1609, Thermal insulating products for building applications — Determination of short term water absorption by partial immersion EN 12086:1997, Thermal insulating products for building applications — Determination of water vapour transmission properties EN 12087, Thermal insulating products for building applications — Determination of long term water absorption by immersion BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) EN 12089, Thermal insulating products for building applications — Determination of bending behaviour EN 12090, Thermal insulating products for building applications — Determination of shear behaviour EN 12430, Thermal insulating products for building applications — Determination of behaviour under point load EN 12431, Thermal insulating products for building applications — Determination of thickness for floating floor insulation products EN 12667, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Products of high and medium thermal resistance EN 12939, Thermal performance of building materials and products — Determination of thermal resistance by means of guarded hot plate and heat flow meter methods — Thick products of high and medium thermal resistance EN 13172:2012, Thermal insulation products — Evaluation of conformity EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire tests EN 13820, Thermal insulating materials for building applications — Determination of organic content EN 13823, Reaction to fire tests for building products — Building products excluding floorings exposed to the thermal attack by a single burning item EN 15715:2009, Thermal insulation products — Instructions for mounting and fixing for reaction to fire testing — Factory made products EN 29052-1, Acoustics — Determination of dynamic stiffness — Part 1: Materials used under floating floors in dwellings (ISO 9052-1) EN 29053, Acoustics — Materials for acoustical applications — Determination of air flow resistance (ISO 9053) EN ISO 354, Acoustics — Measurement of sound absorption in a reverberation room(ISO 354) EN ISO 1182, Reaction to fire tests for products — Non-combustibility test (ISO 1182) EN ISO 1716, Reaction to fire tests for products — Determination of the gross heat of combustion (calorific value) (ISO 1716) EN ISO 9229:2007, Thermal insulation — Vocabulary (ISO 9229:2007) EN ISO 11654, Acoustics — Sound absorbers for use in buildings — Rating of sound absorption (ISO 11654) EN ISO 11925-2, Reaction to fire tests — Ignitability of products subjected to direct impingement of flame — Part 2: Single-flame source test (ISO 11925-2) !EN ISO 13790:2008, Energy performance of buildings — Calculation of energy use for space heating and cooling (ISO 13790:2008)" ISO 16269-6:2005, Statistical interpretation of data — Part 6: Determination of statistical tolerance intervals BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) 3.1 Terms, definitions, symbols, units and abbreviated terms Terms and definitions For the purposes of this document, the terms and definitions given in EN ISO 9229:2007 apply with exception or in addition of the following 3.1.1 mineral wool insulation wool manufactured from molten rock, slag or glass 3.1.2 level value which is the upper or lower limit of a requirement and given by the declared value of the characteristic concerned 3.1.3 class combination of two levels of the same property between which the performance shall fall 3.1.4 mat, blanket flexible fibrous insulation product supplied rolled or flat, which may be faced or enclosed 3.1.5 board; slab rigid or semi-rigid (insulation) product of rectangular shape and cross section in which the thickness is uniform and substantially smaller than the other dimensions Note to entry: Board is usually thinner than slab They may also be supplied in tapered form 3.1.6 facing functional or decorative surface layer with a thickness of less than mm, e.g paper, plastic film, fabric or metal foil, which is not considered as separate thermal insulation layer to be added to the thermal resistance of the product 3.1.7 coating functional or decorative surface layer with a thickness of less than mm usually applied by painting, spraying, pouring or trowelling, which is not considered as separate thermal insulation layer to be added to the thermal resistance of the product 3.1.8 composite insulation product product which can be faced or coated made from two or more layers bonded together by chemical or physical adhesion consisting of at least one factory made thermal insulation material layer 3.1.9 multi-layered insulation product product which can be faced or coated made from two or more layers of a thermal insulation material from the same European Standard, which are bonded together horizontally by chemical or physical adhesion 3.2 Symbols, units and abbreviated terms For the purposes of this document, the following symbols and units apply BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) Annex ZA (informative) !Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation ZA.1 Scope and relevant characteristics This European Standard has been prepared under Mandate M/103 1) "Thermal insulation products" given to CEN by the European Commission and the European Free Trade Association If this European standard is cited in the Official Journal of the European Union (OJEU), the clauses of this standard, shown in this annex, are considered to meet the provisions of the relevant mandate, under the Regulation (EU) No 305/2011 This annex deals with the CE marking of the factory made mineral wool intended for the use indicated in Table ZA.1 and shows the relevant clauses applicable This annex has the same scope as Clause of this standard related to the aspects covered by the mandate and is defined by Table ZA.1 Table ZA.1 — Relevant clauses for factory made mineral wool and intended use Product: Factory made mineral wool (MW) products Intended use: Thermal insulation for buildings Essential Characteristics Clauses in this and other European standard(s) related to essential characteristicsf Notes — Declared RD and λD if possible Thickness — Declared d and T 4.2.6 Reaction to fire Euroclasses — 4.2.7 Durability characteristics a Euroclasses — 4.2.1 Thermal resistance thermal conductivity — Declared RD and λD if possible b 4.2.1 Thermal resistance thermal conductivity 4.2.3 Reaction to fire Durability of reaction to fire against heat, weathering, ageing/degradation Thermal resistance Durability of thermal resistance against heat, weathering, ageing/degradation Regulatory classes 4.2.7 and and Durability characteristics — DS(70,-) DS(23,90) or DS(70,90) c 4.3.3 Compressive stress compressive strength 4.3.5 Point load Compressive strength 1) As amended by mandates M126, M130 and M367 36 or — Declared CS — Declared PL or BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) Tensile/Flexural strength Durability of compressive strength against ageing/degradation Water permeability Water vapour permeability Impact noise transmission index (for floors) Acoustic absorption index Direct index airborne sound insulation Release of dangerous substances to the indoor environment Continuous glowing combustion a 4.3.4 Tensile strength perpendicular to facesd — Declared TR 4.3.6 Compressive creep — Declared CC 4.3.7.1 or Short term water absorption 4.3.7.2 Long term water absorption 4.3.8 Water vapour transmission — Declared MU or Z 4.3.9 Dynamic stiffness — Declared SD 4.3.10.2 Thickness, dL — Declared dL or class 4.3.10.4 Compressibility, c — Declared CP 4.3.12 Air flow resistivity — Declared AFr 4.3.11 Sound absorption — Declared AP and AW 4.3.12 Air flow resistivity — Declared AFr 4.3.13 Release of dangerous substances e — — 4.3.15 Continuous glowing combustion e — — — Declared WS or Declared WL(P) No change in reaction to fire properties for MW products The fire performance of MW does not deteriorate with time The Euroclass classification of the product is related to the organic content, which cannot increase with time b Thermal conductivity of MW products does not change with time, experience has shown the fibre structure to be stable and the porosity contains no other gases than atmospheric air c For dimensional stability thickness only d This characteristic also covers handling and installation e European test methods are under development f Also valid and applicable for multilayers The declaration of the product performance related to certain essential characteristics is not required in those Member States (MS) where there are no regulatory requirements on these essential characteristics for the intended use of the product In this case, manufacturers placing their products on the market of these MS are not obliged to determine nor declare the performance of their products with regard to these essential characteristics and the option “No performance determined” (NPD) in the information accompanying the CE marking and in the declaration of performance (see ZA.3) may be used for those essential characteristics ZA.2 Procedures for AVCP of factory made mineral wool products ZA.2.1 Systems of AVCP The AVCP systems of factory made mineral wool products indicated in Table ZA.1, established by EC Decision 95/204/EC of 31.05.95 (OJ L 129) revised by decision 99/91/EC of 25.01.99 (OJ L 29) amended by th the decision 01/596/EC of January 2001 (OJ L 209) is shown in Table ZA.2 for the indicated intended use and relevant level(s) or class(es) of performance 37 BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) Table ZA.2 — Systems of AVCP Product(s) Level(s) or class(es) Intended use(s) AVCP system(s) (reaction to fire) Thermal insulation products For uses subject to regulations on reaction to fire (Factory made products) (A1, A2, B, C)a (A1, A2, B, C)b, D, E (A1 to E)c, F — Any System 1: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.2 System 3: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.4 System 4: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.5 a Products/materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g an addition of fire retardants or a limiting of organic material) b a Products/materials not covered by footnote ( ) c Products/materials that not require to be tested for reaction to fire (e.g products/materials of classes A1 according to Commission Decision 96/603/EC, as amended) The AVCP of the factory made mineral wool products in Table ZA.1 shall be according to the AVCP procedures indicated in Table ZA.3.1, Table ZA.3.2 and Table ZA.3.3 resulting from application of the clauses of this or other European Standard indicated therein The content of tasks of the notified body shall be limited to those essential characteristics as provided for, if any, in Annex III of the relevant mandate and to those that the manufacturer intends to declare Table ZA.3.1 — Assignment of AVCP tasks for factory made mineral wool products under system for reaction to fire and system (see Table ZA.2) Tasks Content of the task AVCP clauses to apply EN 13172:2012, Clause 5, Annex B Parameters related to essential and Annex C Factory Production characteristics of Table ZA.1 relevant for Control (FPC) and the intended use which are declared 7.3 of this standard Further testing of samples taken at Essential characteristics of Table ZA.1 Annex B factory according to relevant for the intended use which are standard Tasks for the the prescribed test declared manufacturer plan Determination of the product-type on the basis of type testing (including sampling), type calculation, tabulated values or descriptive documentation of the product 38 Essential characteristics of Table ZA.1 relevant for the intended use which are declared and not tested by the notified testing laboratory and by the product certification body involved with reaction to fire of this EN 13172:2012, Clause and 7.2 of this standard BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) Tasks Determination of the product-type on the basis of type testing (including sampling Tasks for notified carried out by the testing laboratory manufacturer), type calculation, tabulated values or descriptive documentation of the product AVCP clauses to apply Content of the task — Thermal resistance; — Release of dangerous substancesa; — Compressive strength bearing applications); — Water permeability (if relevant) Determination of the product-type on the basis of type testing (including sampling), type calculation, — tabulated values or Tasks for the descriptive of the notified product documentation b certification body product (for load and Reaction to fire Parameters related to essential Initial inspection of characteristics of Table ZA.1, relevant for manufacturing plant the intended use which are declared, namely reaction to fire and of FPC Documentation of the FPC Parameters related to essential Continuous characteristics of Table ZA.1, relevant for surveillance, the intended use which are declared, assessment and namely reaction to fire evaluation of FPC Documentation of the FPC a No test method available yet b Sampling shall be carried out as defined in 5.1 EN 13172:2012, Clause 7.2 of this standard EN 13172:2012, Clause and 7.2 of this standard EN 13172:2012, Annex B and Annex C and 7.3 of this standard EN 13172:2012, Annex B and Annex C and 7.3 of this standard 39 BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) Table ZA.3.2 — Assignment of AVCP tasks for factory made mineral wool products under system (see Table ZA.2) Content of the task Tasks AVCP clauses to apply EN 13172:2012 Parameters related to essential Clause 5, Annex C Factory Production Control characteristics of Table ZA.1 and Annex D (FPC) relevant for the intended use which and are declared 7.3 of this standard Tasks for the Determination of the manufacturer product-type on the basis of type testing (including sampling), type calculation, tabulated values or descriptive documentation of the product EN 13172:2012, Essential characteristics of Table Clause ZA.1 relevant for the intended use which are declared and not tested by and the notified testing laboratory 7.2 of this standard — Reaction to fire; Determination of the — product type on the basis of — Tasks for a type testing (based on notified testing sampling carried out by the laboratory manufacturer) or tabulated — values Compressive strength (for load bearing applications); — Water permeability (if relevant) a 40 No test method available yet Thermal resistance; Release of dangerous substancesa; EN 13172:2012, Clause and 7.2 of this standard BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) Table ZA.3.3 — Assignment of AVCP tasks for factory made mineral wool products under combined system for reaction to fire and system (see Table ZA.2) Tasks Factory Production Control (FPC) Tasks for the manufacturer Tasks for a notified testing laboratory a Determination of the product-type on the basis of type testing (including sampling), type calculation, tabulated values or descriptive documentation of the product Determination of the product type on the basis of type testing (based on sampling carried out by the manufacturer) or tabulated values Content of the task Parameters related to essential characteristics of Table ZA.1 relevant for the intended use which is declared AVCP clauses to apply EN 13172:2012, Clause 5, Annex C and Annex D and 7.3 of this standard EN 13172:2012, Essential characteristics of Table Clause ZA.1 relevant for the intended use which are declared and not tested by and the notified testing laboratory 7.2 of this standard — — Thermal resistance; Release of dangerous substancesa; — Compressive strength (for load bearing applications); — Water permeability (if relevant) EN 13172:2012, Clause and 7.2 of this standard No test method available yet ZA.2.2 Declaration of Performance (DoP) ZA.2.2.1 General The manufacturer draws up the DoP and affixes the CE marking on the basis of the different AVCP systems set out in Annex V of the Regulation (EU) No 305/2011: In case of products under system — the factory production control and further testing of samples taken at the factory according to the prescribed test plan, carried out by the manufacturer; and — the certificate of constancy of performance issued by the notified product certification body on the basis of determination of the product type on the basis of type testing (including sampling), type calculation, tabulated values or descriptive documentation of the product; initial inspection of the manufacturing plant and of factory production control and continuous surveillance, assessment and evaluation of factory production control In case of products under system — the factory production control carried out by the manufacturer; and — the determination of the product-type on the basis of type testing (based on sampling carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the carried out by the notified testing laboratory 41 BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) In case of products under system — the factory production control carried out by the manufacturer — the determination by the manufacturer of the product-type on the basis of type testing, type calculation, tabulated values or descriptive documentation of the product ZA.2.2.2 Content The model of the DoP is provided in Annex III of the Regulation (EU) No 305/2011 According to this Regulation, the DoP shall contain, in particular, the following information: — the reference of the product-type for which the declaration of performance has been drawn up; — the AVCP system or systems of the construction product, as set out in Annex V of the CPR; — the reference number and date of issue of the harmonised standard which has been used for the assessment of each essential characteristic; — where applicable, the reference number of the Specific Technical Documentation used and the requirements with which the manufacturer claims the product complies The DoP shall in addition contain: a) the intended use or uses for the construction product, in accordance with the applicable harmonized technical specification; b) the list of essential characteristics, as determined in the harmonized technical specification for the declared intended use or uses; c) the performance of at least one of the essential characteristics of the construction product, relevant for the declared intended use or uses; d) where applicable, the performance of the construction product, by levels or classes, or in a description, if necessary based on a calculation in relation to its essential characteristics determined in accordance with the Commission determination regarding those essential characteristics for which the manufacturer shall declare the performance of the product when it is placed on the market or the Commission determination regarding threshold levels for the performance in relation to the essential characteristics to be declared; e) the performance of those essential characteristics of the construction product which are related to the intended use or uses, taking into consideration the provisions in relation to the intended use or uses where the manufacturer intends the product to be made available on the market; f) for the listed essential characteristics for which no performance is declared, the letters "NPD" (No Performance Determined) Regarding the supply of the DoP, article of the Regulation (EU) No 305/2011 applies The information referred to in Article 31 or, as the case may be, in Article 33 of Regulation (EC) No 1907/2006, (REACH) shall be provided together with the DOP 42 BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) ZA.2.2.3 Example of DoP The following gives an example of a filled-in DoP for factory made mineral wool for EN 13162 DECLARATION OF PERFORMANCE No 0123-DoP-2013/10/07 Unique identification code of the product-type: ABCD Roofboard Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11(4) of the CPR: see product label Intended use or uses of the construction product, in accordance with the applicable harmonized technical specification, as foreseen by the manufacturer: Thermal insulation for buildings Name, registered trade name or registered trade mark and contact address of the manufacturer as required under Article 11(5): Any Co Ltd, PO Box 21, B-1050 Where applicable, name and contact address of the authorized representative whose mandate covers the tasks specified in Article 12(2): not relevant System or systems of assessment and verification of constancy of performance of the construction product as set out in CPR, Annex V: Systems and In case of the declaration of performance concerning a construction product covered by a harmonized standard: Notified certification body No 4567 performed, carried out the determination of the product type, the initial inspection of the manufacturing plant and of factory production control and the continuous surveillance, assessment and evaluation of factory production control and issued the certificate of constancy of performance for reaction to fire Notified testing laboratory No 7456 performed the test reports for the other relevant declared characteristics Declared performance Essential characteristics Thermal resistance Reaction to fire Performance Harmonized technical specification Thermal resistance and RD 2,5 m2⋅K/W thermal conductivity λD 0,040 W/m⋅K thickness dN 100 mm, T5 Reaction to fire A1 Durability of reaction to fire against heat, Durability weathering, ageing/ characteristics degradation A1 EN 13162:2012+A1:2015 Thermal resistance and RD 2,5 m2⋅K/W Durability of thermal resistance against heat, thermal conductivity λD 0,040 W/m⋅K weathering, ageing/ Durability degradation DS(70,90) characteristics 43 BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) Essential characteristics Compressive strength Compressive stress CS(10)70 Point load PL(5)100 Tensile/ strength Flexural Tensile strength NPD perpendicular to faces Durability compressive against degradation of strength Compressive creep ageing/ Long term absorption Water permeability NPD water WL(P) Water vapour vapour transmission, MU1 Water vapour diffusion resistance factor, Water permeability Dynamic stiffness NPD Impact noise Thickness transmission index (for Compressibility floors) Acoustic index Harmonized technical specification Performance absorption Direct airborne insulation index sound NPD NPD Air flow resistivity NPD Sound absorption NPD Air flow resistivity NPD Release of dangerous Release of dangerous substances to the indoor NPD substances environment Continuous combustion glowing Continuous combustion glowing NPD NPD No Performance Determined The performance of the product identified in points and is in conformity with the declared performance in point This declaration of performance is issued under the sole responsibility of the manufacturer identified in point Signed for and on behalf of the manufacturer by: ………………………………………………………………………………………………………………………… (Name and function) ………………………………… …………… ……………………………… ……………………… (Place and date of issue) (Signature) NOTE For characteristics where e.g the declaration is different for different thickness a table is needed instead of a single value in the table above 44 BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) ZA.3 CE Marking and labelling The CE marking symbol shall be in accordance with the general principles set out in Article 30 of Regulation (EC) No 765/2008 and shall be affixed visibly, legibly and indelibly: — to the factory made mineral wool (MW) product or — to a label attached to it Where this is not possible or not warranted on account of the nature of the product, it shall be affixed to the packaging or to the accompanying documents The CE marking shall be followed by: — the last two digits of the year in which it was first affixed; — the name and the registered address of the manufacturer, or the identifying mark allowing identification of the name and address of the manufacturer easily and without any ambiguity; — the unique identification code of the product-type; — the reference number of the declaration of performance; — the level or class of the performance declared; — the dated reference to the harmonized technical specification applied; — the identification number of the notified body [only for products under systems 1and 3]; — the intended use as laid down in the harmonized technical specification applied The CE marking shall be affixed before the construction product is placed on the market It may be followed by a pictogram or any other mark notably indicating a special risk or use Figure ZA.1 gives an example of the information related to products subject to AVCP systems and to be given on the product or to a label attached to it 45 BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) CE marking, consisting of the “CE”-symbol 4567 1234/ 7456 Identification number of the product certification body Identification number of the notified test laboratory/ laboratories AnyCo Ltd, PO Box 21, B-1050 name and the registered address of the manufacturer, or identifying mark 15 Last two digits of the year in which the marking was first affixed 0123 – DoP – 2013/10/07 reference number of the DoP EN 13162:2012+A1:2015 No of European standard applied, as referenced in OJEU ABCD Roofboard Unique identification code of the product-type ThIB RD Intended use of the product as laid down in the European standard applied dN 2,5 m2⋅K/W RtF A1 RD 2,5 m2⋅K/W λD 100 mm 0,040 W/(m⋅K) DS(70,90) CS(10)70; PL(5)100 WL(P) Thermal resistance Reaction to fire – Euroclass Durability of thermal resistance against heat, weathering, ageing/ degradation Durability thickness Compressive strength – Point load Water permeability Water vapour permeability MU1 MW – EN 13162 — T5 – DS(70,90) – CS(10)70 – PL(5)100 – MU1 Designation code (in accordance with Clause for the relevant characteristics according to Table ZA.1) Level or class of the performance declared Figure ZA.1 — Example CE marking information of products under AVCP system and system 3" 46 BS EN 13162:2012+A1:2015 EN 13162:2012+A1:2015 (E) EN 13162:2012+A1:2015 (E) Bibliography [1] EN 1991-1-1, Eurocode 1: Actions on structures — Part 1-1: General actions — Densities, self-weight, imposed loads for buildings [2] EN 1608, Thermal insulating products for building applications — Determination of tensile strength parallel to faces [3] EN 14064-1, Thermal insulation products for buildings — In-situ formed loose-fill mineral wool (MW) products — Part 1: Specification for the loose-fill products before installation [4] EN 14064-2, Thermal insulation products for buildings — In-situ formed loose-fill mineral wool (MW) products — Part 2: Specification for the installed products [5] EN 14303, Thermal insulation products for building equipment and industrial installations — Factory made mineral wool (MW) products — Specification [6] EN ISO 10456, Building materials and products — Hygrothermal properties —Tabulated design values and procedures for determining declared and design thermal values (ISO 10456) 47 This page deliberately left blank This page deliberately left blank NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW British Standards Institution (BSI) BSI is the national body responsible for preparing British Standards and other standards-related publications, information and services BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited About us Revisions We bring together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions Our British Standards and other publications are updated by amendment or revision The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process Organizations of all sizes and across all sectors choose standards to help them achieve their goals Information on standards We can provide you with the knowledge that your organization needs to succeed Find out more about British Standards by visiting our website at bsigroup.com/standards or contacting our Customer Services team or Knowledge Centre Buying standards You can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at bsigroup.com/shop, where hard copies can also be purchased If you need international and foreign standards from other Standards Development Organizations, hard copies can be ordered from our Customer Services team Subscriptions Our range of subscription services are designed to make using standards easier for you For further information on our subscription products go to bsigroup.com/subscriptions With British Standards Online (BSOL) you’ll have instant access to over 55,000 British and adopted European and international standards from your desktop It’s available 24/7 and is refreshed daily so you’ll always be up to date You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single copy and subscription format, by becoming a BSI Subscribing Member PLUS is an updating service exclusive to BSI Subscribing Members You will automatically receive the latest hard copy of your standards when they’re revised or replaced To find out more about becoming a BSI Subscribing Member and the benefits of membership, please visit bsigroup.com/shop With a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet Licences can cover as few or as many users as you wish With updates supplied as soon as they’re available, you can be sure your documentation is current For further information, email bsmusales@bsigroup.com BSI Group Headquarters 389 Chiswick High Road London W4 4AL UK We continually improve the quality of our products and services to benefit your business If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please inform the Knowledge Centre Copyright All the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that owns copyright in the information used (such as the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI Details and advice can be obtained from the Copyright & Licensing Department Useful Contacts: Customer Services Tel: +44 845 086 9001 Email (orders): orders@bsigroup.com Email (enquiries): cservices@bsigroup.com Subscriptions Tel: +44 845 086 9001 Email: subscriptions@bsigroup.com Knowledge Centre Tel: +44 20 8996 7004 Email: knowledgecentre@bsigroup.com Copyright & Licensing Tel: +44 20 8996 7070 Email: copyright@bsigroup.com

Ngày đăng: 14/04/2023, 00:55

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN