1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 12058 2015

48 0 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 48
Dung lượng 1,15 MB

Nội dung

BS EN 12058:2015 BSI Standards Publication Natural stone products — Slabs for floors and stairs — Requirements BS EN 12058:2015 BRITISH STANDARD National foreword This British Standard is the UK implementation of EN 12058:2015 It supersedes BS EN 12058:2004 which is withdrawn The UK participation in its preparation was entrusted to Technical Committee B/545, Natural stone A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © The British Standards Institution 2015 Published by BSI Standards Limited 2015 ISBN 978 580 76928 ICS 91.100.15 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2015 Amendments/corrigenda issued since publication Date Text affected EN 12058 EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM March 2015 ICS 91.100.15 Supersedes EN 12058:2004 English Version Natural stone products - Slabs for floors and stairs Requirements Produits en pierre naturelle - Dalles de revêtement de sol et d'escalier - Exigences Natursteinprodukte - Bodenplatten und Stufenbeläge Anforderungen This European Standard was approved by CEN on January 2015 CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels © 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members Ref No EN 12058:2015 E BS EN 12058:2015 EN 12058:2015 (E) Contents Page Foreword Scope Normative references Terms and definitions 4.1 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.1.6 4.1.7 4.2 4.2.1 4.2.2 4.2.3 4.2.4 4.2.5 4.2.6 4.2.7 4.2.8 4.2.9 4.2.10 4.2.11 4.2.12 4.2.13 4.2.14 4.2.15 4.2.16 4.2.17 4.2.18 Characteristics of natural stone slabs Geometrical characteristics General Dimensions .7 Flatness Length and width Special shapes .8 Commercial sizes of slabs for floors and stairs Surface finish Physical and mechanical characteristics General Denomination Visual appearance Flexural strength 11 Bond strength/adhesion 11 Water absorption at atmospheric pressure 11 Reaction to fire 11 Water absorption by capillarity 11 Apparent density and open porosity 11 Durability 12 Thermal shock resistance 12 Water vapour permeability 12 Slip resistance 12 Skid resistance 12 Tactility 13 Direct airborne sound insulation 13 Thermal conductivity 13 Release of dangerous substances 13 5.1 5.2 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5 5.2.6 5.2.7 5.2.8 Testing, assessment and sampling methods 13 Testing 13 Sampling 13 General 13 Principles of sampling 14 Taking bulk samples 14 Preparing a sampling plan 14 Sampling apparatus 14 Sampling methods 14 Marking, packaging and dispatch of the samples 16 Sampling report 16 6.1 6.2 6.2.1 6.2.2 Assessment and verification of constancy of performance - AVCP 17 General 17 Type Testing 18 General 18 Test samples, testing and compliance criteria 18 BS EN 12058:2015 EN 12058:2015 (E) 6.2.3 6.2.4 6.2.5 6.3 6.3.1 6.3.2 6.3.3 6.3.4 6.3.5 Test reports 19 Shared other party results 20 Cascading determination of the product type results 20 Factory production control (FPC) 21 General 21 Requirements 22 Product specific requirements 25 One-off products, pre-production products (e.g prototypes) and products produced in very low quantity 26 Procedure for modifications 27 Marking and packaging 27 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation 29 ZA.1 Scope and relevant characteristics 29 ZA.2 Procedure for AVCP of natural stone for floorings and stairs 32 ZA.2.1 System(s) of AVCP 32 ZA.2.2 Declaration of performance (DoP) 35 ZA.2.2.1 General 35 ZA.2.2.2 Content 36 ZA.2.2.3 Example of DoP 36 ZA.2.2.3.1 Example of DoP for slabs for internal use 36 ZA.2.2.3.2 Example of DoP for slabs for external use 38 ZA.3 CE marking and labelling 40 Bibliography 44 BS EN 12058:2015 EN 12058:2015 (E) Foreword This document (EN 12058:2015) has been prepared by Technical Committee CEN/TC 246 “Natural stones”, the secretariat of which is held by UNI This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2015, and conflicting national standards shall be withdrawn at the latest by December 2016 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights This document supersedes EN 12058:2004 EN 12058:2015 includes the following significant technical changes with respect to EN 12058:2004: − nominal thickness tolerances changed; − durability, skid resistance, direct airborne sound insulation, thermal conductivity, release of dangerous substances added to requirements; − sampling at the point of delivery added to the sampling; − assessment and verification of constancy of performance added; − Annex ZA substantially changed This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports basic requirements for construction works of Regulation (EU) No.305/2011 on Construction Products For relationship with the Regulation, see informative Annex ZA, which is an integral part of this document This European Standard is one of a series of standards for specifications of natural stone products which includes the following: — EN 1467, Natural stone — Rough blocks — Requirements; — EN 1468, Natural stone — Rough slabs — Requirements; — EN 1469, Natural stone products — Slabs for cladding — Requirements; — EN 12057, Natural stone products — Modular tiles — Requirements; — EN 12058, Natural stone products — Slabs for floors and stairs — Requirements; — EN 12059, Natural stone products — Dimensional stone work — Requirements According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom BS EN 12058:2015 EN 12058:2015 (E) Scope This European Standard specifies requirements for flat natural stone slabs used as paving units for internal (including enclosed public transport premises) and/or external uses in floors and stairs including skirtings This European Standard does not cover mineral aggregates and artificial agglomerated stone material and does not cover installation Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies EN 1745, Masonry and masonry products - Methods for determining thermal properties EN 1925, Natural stone test methods - Determination of water absorption coefficient by capillarity EN 1936, Natural stone test methods - Determination of real density and apparent density, and of total and open porosity EN 12371, Natural stone test methods - Determination of frost resistance EN 12372, Natural stone test methods - Determination of flexural strength under concentrated load EN 12407, Natural stone test methods - Petrographic examination EN 12440, Natural stone - Denomination criteria EN 12670:2001, Natural stone - Terminology EN 13373, Natural stone test methods - Determination of geometric characteristics on units EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification using data from reaction to fire tests EN 13755, Natural stone test methods - Determination of water absorption at atmospheric pressure EN 14066, Natural stone test methods - Determination of resistance to ageing by thermal shock EN 14157, Natural stone test methods - Determination of the abrasion resistance CEN/TS 16165:2012, Determination of slip resistance of pedestrian surfaces - Methods of evaluation EN ISO 10456, Building materials and products - Hygrothermal properties -Tabulated design values and procedures for determining declared and design thermal values (ISO 10456) EN ISO 12572, Hygrothermal performance of building materials and products - Determination of water vapour transmission properties (ISO 12572) Terms and definitions For the purposes of this document, the terms and definitions given in EN 12670:2001 and the following apply 3.1 slab for floors flat piece of natural stone obtained by cutting or splitting at a nominal thickness > 12 mm BS EN 12058:2015 EN 12058:2015 (E) 3.2 slab for stairs flat piece of natural stone obtained by cutting or splitting at a nominal thickness > 12 mm to form the horizontal part of a stair step (tread) or the vertical part of a stair step (riser) 3.3 dimensions of rectangular slabs for floors length l, width b and thickness d are the dimensions of a slab for floors, given in the stated sequences in millimetres (see Figure 1) Figure — Dimensions of slabs for floors 3.4 dimensions of rectangular slabs for stairs length l, width b and thickness d are the dimensions of a slab for stairs, separated for treads and risers, given in the stated sequences in millimetres (see Figure 2) Key tread riser Figure — Dimensions of slabs for stairs BS EN 12058:2015 EN 12058:2015 (E) 3.5 lower expected value lower expected value (EL) corresponds to the %-quantile of a logarithmic normal distribution for a confidence level of 75 % 3.6 higher expected value higher expected value (EH) corresponds to the 95 %-quantile of a logarithmic normal distribution for a confidence level of 75 % 3.7 skirting flat piece of natural stone obtained by cutting or splitting at a nominal thickness larger than 12 mm, laid on each wall surrounding a flooring and in contact with it Characteristics of natural stone slabs 4.1 4.1.1 Geometrical characteristics General All measurements shall be carried out in accordance with EN 13373 and all measured values of individual units shall fall within the required tolerances 4.1.2 Dimensions The thickness shall be measured in accordance with EN 13373 and the measured values shall not deviate from the nominal thickness by more than the tolerances given in Table Table — Tolerances on the nominal thickness Nominal thickness in mm Tolerance More than 12 Up to and including 30 ±10 % More than 30 Up to and including 80 ±3 mm More than 80 ±5 mm Stricter deviations may be declared by the manufacturer NOTE If the slab is to be fixed by adhesives or a thin mortar bed, stricter deviations may be needed The required thickness of slabs for floors and stairs shall result from a structural analysis or similar procedure which takes into account the technical and physical properties of the stone and the intended application Visible edges shall be gauged For natural cleft/riven faces, Table does not apply and the deviations shall be set out by the manufacturer 4.1.3 Flatness The deviation from flatness of the surface (except for natural cleft faces) when measured in accordance with EN 13373 shall not exceed 0,2 % of the slab length, and shall not exceed mm For natural cleft faces, the deviation on flatness shall be set out by the manufacturer BS EN 12058:2015 EN 12058:2015 (E) 4.1.4 Length and width The length or width shall not deviate from the nominal size by more than given in Table Table — Tolerances on length and width Nominal length or width < 600 mm ≥ 600 mm Sawn edges thickness ≤ 50 mm ±1 mm ±1,5 mm Sawn edges thickness > 50 mm ±2 mm ±3 mm Stricter deviations may be declared by the manufacturer For natural cleft/riven edges, Table does not apply and the tolerances on length, width and squareness shall be set out by the manufacturer 4.1.5 Special shapes The permissible deviation at any point shall be as stated in Table (see Figure 3) Each slab angle shall be in accordance with the agreed geometry Pieces of special or irregular shape shall be checked for compliance with the required shape by use of a suitable template, the permissible tolerance at any point shall be as stated in Table (see Figure 3) Stricter deviations may be declared by the manufacturer Dimensions in millimetres Key nominal size the slab sides shall fall within the two dotted lines indicating the tolerances of length and width according to Table Figure — Example of tolerances on angles 4.1.6 Commercial sizes of slabs for floors and stairs Commercial sizes shall be based on the area of the smallest possible circumscribed rectangle measured in square metres accurate to two decimal places BS EN 12058:2015 EN 12058:2015 (E) ZA.2 Procedure for AVCP of natural stone for floorings and stairs ZA.2.1 System(s) of AVCP The AVCP system(s) of natural stone slabs for floorings and stairs indicated in Tables ZA.1.1 to ZA.1.2, established by Decision 97/808/EC of 20 November 1997(OJ L331 of 3.12.1997) as amended firstly by Commission Decision 99/453/EC, of 18 June 1999 (OJ L178 of 14.7.1999), secondly by Commission Decision 2001/596/EC, of January 2001 (O.J L209 of 2.8.2001) and thirdly by Commission Decision 2006/190/EC, March 2006 (OJ L66 of 8.3.2006) is shown in Table ZA.2 for the indicated intended use(s) and relevant level(s) or class(es) of performance Table ZA.2 — System(s) of AVCP Product(s) Intended use(s) Level(s) or class(es) of performance A1FL(*), A2FL(*), BFL(*), CFL(*) “Rigid flooring products (A) Components: paving units For internal uses including enclosed public transport premises Rigid flooring products: Paving units(with flat or tactile surface) For internal uses and road finishes to cover pedestrian and vehicular circulation areas AVCP system(s) A1FL(**), A2FL(**), BFL(**), CFL(**), DFL, EFL (A1FL to EFL) (***) and FFL - (*) Products/materials for which a clearly identifiable stage in the production process which results in an improvement of the reaction to fire classification (e.g no addition of fire retardants nor a limiting, during the production process, of organic material) (**) Products/materials not covered by footnote (*) (***) Products/materials that not require to be tested for reaction to fire (e.g products/materials of Class A1 according to Commission Decision 96/603/EC, as amended) System 1: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.2 System 3: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.4 System 4: See Regulation (EU) No 305/2011 (CPR) Annex V, 1.5 NOTE For the purpose of this standard natural stone slabs for floors and stairs are considered as paving units The AVCP of the natural stone slabs for floors and stairs in Tables ZA.1.1 to ZA.1.2 shall be according to the AVCP procedures indicated in Tables ZA.3.1 to ZA.3.3 resulting from application of the clauses of this or other European Standard indicated therein The content of tasks of the notified body shall be limited to those essential characteristics as provided for, if any, in Annex III of the relevant mandate and to those that the manufacturer intends to declare 32 BS EN 12058:2015 EN 12058:2015 (E) Table ZA.3.1— Assignment of AVCP tasks for slabs of natural stone for floors and stairs which are made for internal and external use under systems (RtoF), 3(DS), (rest) Tasks Content of the task AVCP clauses to apply Tasks for the manufacturer Factory production (FPC) control Parameters related to essential characteristics of Tables ZA.1.1 or ZA.1.2 relevant for the intended use, which are declared 6.1 and 6.3 Further testing of samples taken at factory according to the prescribed test plan Essential characteristics of Tables ZA.1.1 or ZA.1.2 relevant for the intended use which are declared, namely reaction to fire (for classes A1FL(*), A2FL(*), BFL(*), CFL(*) (for internal floors and stairs)) 6.1 and 6.3 Determination of the product type on the basis of type testing (including sampling), type calculation, tabulated values or descriptive documentation of the product Essential characteristics of Tables ZA.1.1 or ZA.1.2 relevant for the intended use indicated, namely - Braking strength (for internal and external floors and stairs) - Slipperiness (for internal and external floors and stairs) - Skid resistance (for external floors and stairs) - Tactility (for internal and external floors and stairs); and - Thermal conductivity (for external floors and stairs) 6.1 and 6.2 Tasks for a notified Testing laboratory Determination of the product type on the basis of type testing (based on sampling carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the product Essential characteristics of Tables ZA.1.1, or ZA.1.2 relevant for the intended use indicated in Annex III of the mandate, namely - Emission of radioactivity (for internal floors and stairs); and - Release of other dangerous substances (for internal floors and stairs) 6.1 and 6.2 Tasks for the notified product certification body Determination of the product type on the basis of type testing (including sampling), type calculation, tabulated values or descriptive documentation of the product Essential characteristics of Tables ZA.1.1 or ZA.1.2 relevant for the intended use indicated, namely reaction to fire (for classes A1FL(*), A2FL(*), BFL(*), CFL(*) (for internal floors and stairs)) 6.1 and 6.2 Initial inspection of manufacturing plant and of FPC Parameters related to essential characteristics of Tables ZA.1.1 or ZA.1.2 relevant for the intended use, which are declared, namely reaction to fire (for A1FL(*), A2FL(*), BFL(*), CFL(*) (for internal floors and stairs)) Documentation of the FPC 6.1 and 6.3 Continuous surveillance, assessment and evaluation of FPC Parameters related to essential characteristics of Tables ZA.1.1 or ZA.1.2 relevant for the intended use, which are declared, namely reaction to fire (for classes A1FL(*), A2FL(*), BFL(*), CFL(*) (for internal floors and stairs)) Documentation of FPC 6.1 and 6.3 (*) See Table ZA.2 33 BS EN 12058:2015 EN 12058:2015 (E) Table ZA.3.2— Assignment of AVCP tasks for slabs of natural stone for floors and stairs which are made for internal and external use under systems (RtoF and DS for internal floors), and (rest) Tasks Tasks for the manufacturer Tasks for a notified testing laboratory Content of the task AVCP clauses to apply Factory production control (FPC) Parameters related to essential characteristics of Tables ZA.1.1 or ZA.1.2 relevant for the intended use which are declared 6.1 and 6.3 Determination of the product type on the basis of type testing (including sampling), type calculation, tabulated values or descriptive documentation of the product Essential characteristics of Tables ZA.1.1 or ZA.1.2 relevant for the intended use indicated, namely - Braking strength (for internal and external floors and stairs) - Slipperiness (for internal and external floors and stairs) - Skid resistance (for external floors and stairs) - Tactility (for internal and external floors and stairs); and - Thermal conductivity (for external floors and stairs) - Emission of radioactivity (for external floors and stairs); and - Release of other dangerous substances (for external floors and stairs); 6.1 and 6.2 Determination of the product type on the basis of type testing (based on sampling carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the product Essential characteristics of Table ZA.1.1 or Table ZA.1.2 relevant for the intended use indicated in Annex III of the mandate, namely - Reaction to fire (for classes A1FL(**), A2FL(**), BFL(**), CFL(**), DFL and EFL) (for internal floors and stairs); - Emission of radioactivity (for internal floors and stairs); and - Release of other dangerous substances (for internal floors and stairs); 6.1 and 6.2 (**) See Table ZA.2 34 BS EN 12058:2015 EN 12058:2015 (E) Table ZA.3.3 — Assignment of AVCP tasks for slabs of natural stone for floorings and stairs which are made for internal and external use under system Tasks Tasks for the manufacturer Content of the task AVCP clauses to apply Factory production control (FPC) Parameters related to essential characteristics of Tables ZA.1.1 or ZA.1.2 relevant for the intended use which are declared 6.1 and 6.3 Determination of the product type on the basis of type testing (including sampling), type calculation, tabulated values or descriptive documentation of the product Essential characteristics of Tables ZA.1.1 or ZA.1.2 relevant for the intended use indicated, namely - Reaction to fire (for classes (A1FL to EFL)(***)) (for internal floors and stairs) - Braking strength (for internal and external floors and stairs) - Slipperiness (for internal and external floors and stairs) - Skid resistance (for external floors and stairs) - Tactility (for internal and external floors and stairs); and - Thermal conductivity (for external floors and stairs) 6.1 and 6.2 (***) See Table ZA.2 ZA.2.2 Declaration of performance (DoP) ZA.2.2.1 General The manufacturer draws up the DoP and affixes the CE marking on the basis of the different AVCP systems set out in Annex V of the Regulation (EU) No 305/2011: In case of products under system — the factory production control and further testing of samples taken at the factory according to the prescribed test plan, carried out by the manufacturer; and — the certificate of constancy of performance issued by the notified product certification body on the basis of determination of the product type on the basis of type testing (including sampling), type calculation, tabulated values or descriptive documentation of the product; initial inspection of the manufacturing plant and of factory production control and continuous surveillance, assessment and evaluation of factory production control In case of products under system — the factory production control carried out by the manufacturer; and — the determination of the product-type on the basis of type testing (based on sampling carried out by the manufacturer), type calculation, tabulated values or descriptive documentation of the product, carried out by the notified testing laboratory 35 BS EN 12058:2015 EN 12058:2015 (E) In case of products under system — the factory production control carried out by the manufacturer — the determination by the manufacturer of the product-type on the basis of type testing, type calculation, tabulated values or descriptive documentation of the product ZA.2.2.2 Content The model of the DoP is provided in Annex III of the Regulation (EU) No 305/2011 According to this Regulation, the DoP shall contain, in particular, the following information: — the reference of the product-type for which the declaration of performance has been drawn up; — the AVCP system or systems of the construction product, as set out in Annex V of the CPR; — the reference number and date of issue of the harmonized standard which has been used for the assessment of each essential characteristic; — where applicable, the reference number of the Specific Technical Documentation used and the requirements with which the manufacturer claims the product complies The DoP shall in addition contain: (a) the intended use or uses for the construction product, in accordance with the applicable harmonized technical specification; (b) the list of essential characteristics, as determined in the harmonized technical specification for the declared intended use or uses; (c) the performance of at least one of the essential characteristics of the construction product, relevant for the declared intended use or uses; (d) where applicable, the performance of the construction product, by levels or classes, or in a description, if necessary based on a calculation in relation to its essential characteristics determined in accordance with the Commission determination regarding those essential characteristics for which the manufacturer shall declare the performance of the product when it is placed on the market or the Commission determination regarding threshold levels for the performance in relation to the essential characteristics to be declared (e) the performance of those essential characteristics of the construction product which are related to the intended use or uses, taking into consideration the provisions in relation to the intended use or uses where the manufacturer intends the product to be made available on the market; (f) for the listed essential characteristics for which no performance is declared, the letters “NPD” (No Performance Determined); Regarding the supply of the DoP, article of the Regulation (EU) No 305/2011 applies The information referred to in Article 31 or, as the case may be, in Article 33 of Regulation (EC) No 1907/2006, (REACH) shall be provided together with the DoP ZA.2.2.3 Example of DoP ZA.2.2.3.1 Example of DoP for slabs for internal use The following gives an example of a filled-in DoP for internal uses for slabs for floors and stairs 36 BS EN 12058:2015 EN 12058:2015 (E) DECLARATION OF PERFORMANCE No 003CPR2014-04 Unique identification code of the product type: Type Code SEG 4549 Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11(4): SEEBACH GRANIT (Type 1234) granite light grey near Achern, Schwarzwald, Baden-Württemberg, Germany Intended use or uses of the construction product, in accordance with the applicable harmonized technical specification, as foreseen by the manufacturer: Natural stone slabs used as internal flooring and stairs Name, registered trade name or registered trade mark and contact address of the manufacturer as required under Article 11(5): AnyCo SA, PO Box 21 B-1050 Brussels, Belgium Tel +32987654321 Fax: +32123456789 Email: anyco.sa@provider.be Where applicable, name and contact address of the authorized representative whose mandate covers the tasks specified in Article 12(2): Not applicable System or systems of assessment and verification of constancy of performance of the construction product as set out in CPR, Annex V: System and In case of the declaration of performance concerning a construction product covered by a harmonized standard: 8765 In case of the declaration of performance concerning a construction product covered by a European Technical Assessment has been issued: Not relevant 37 BS EN 12058:2015 EN 12058:2015 (E) Declared performance Essential characteristics Performance Resistance to fire Class A 1FL Breaking strength as flexural strength - lower expected value - mean value - standard deviation 11 MPa 14 MPa 1,4 MPa Slip resistance - sawn surface (SRV “wet”,“dry“) - honed surface (C 120) “wet”,“dry“) 65, 85 55, 75 Harmonized specification (SRV technical EN 12058:2015 Tactility None Direct airborne sound insulation - mean value 2750 kg/m Thermal conductivity - mean value W/(mK) Release of radioactivity - Release of dangerous substances - 10 The performance of the product identified in points and is in conformity with the declared performance in point This declaration of performance is issued under the sole responsibility of the manufacturer identified in point Signed for and on behalf of the manufacturer by: ……………………………………………………………………………………………………………………………… (name and function) ………………………………… …………… ………………………………… …………… (place and date of issue) (signature) ZA.2.2.3.2 Example of DoP for slabs for external use The following gives an example of a filled-in DoP for external uses for slabs for floors and stairs DECLARATION OF PERFORMANCE No 004CPR2014-04 Unique identification code of the product type: Type Code SEG 4549 Type, batch or serial number or any other element allowing identification of the construction product as required under Article 11(4): SEEBACH GRANIT (Type 1234) 38 BS EN 12058:2015 EN 12058:2015 (E) granite light grey near Achern, Schwarzwald, Baden-Württemberg, Germany Intended use or uses of the construction product, in accordance with the applicable harmonized technical specification, as foreseen by the manufacturer: Natural stone slabs used as external flooring and stairs Name, registered trade name or registered trade mark and contact address of the manufacturer as required under Article 11(5): AnyCo SA, PO Box 21 B-1050 Brussels, Belgium Tel +32987654321 Fax: +32123456789 Email: anyco.sa@provider.be Where applicable, name and contact address of the authorized representative whose mandate covers the tasks specified in Article 12(2): Not applicable System or systems of assessment and verification of constancy of performance of the construction product as set out in CPR, Annex V: System and In case of the declaration of performance concerning a construction product covered by a harmonized standard: 8765 In case of the declaration of performance concerning a construction product covered by a European Technical Assessment has been issued: Not relevant 39 BS EN 12058:2015 EN 12058:2015 (E) Declared performance Essential characteristics Performance Breaking strength as flexural strength - lower expected value - mean value - standard deviation 11 MPa 14 MPa 1,4 MPa Slip resistance - sawn surface (SRV “wet”, “dry“) - honed surface (C 120) (SRV “wet”, “dry“) 65, 85 55, 75 Tactility None Durability of flexural strength against freeze thaw mean value before freeze thaw mean value after freeze thaw 14 MPa 13 MPa Harmonized specification technical EN 12058:2015 10 The performance of the product identified in points and is in conformity with the declared performance in point This declaration of performance is issued under the sole responsibility of the manufacturer identified in point Signed for and on behalf of the manufacturer by: ……………………………………………………………………………………………………………………………… (name and function) ………………………………… …………… ………………………………… …………… (place and date of issue) (signature) ZA.3 CE marking and labelling The CE marking symbol shall be in accordance with the general principles set out in Article 30 of Regulation (EC) No 765/2008 and shall be affixed visibly, legibly and indelibly — to the natural stone for cladding or — to a label attached to it Where this is not possible or not warranted on account of the nature of the product, it shall be affixed: — o the packaging or — to the accompanying documents The CE marking shall be followed by: — 40 the last two digits of the year in which it was first affixed, BS EN 12058:2015 EN 12058:2015 (E) — the name and the registered address of the manufacturer, or the identifying mark allowing identification of the name and address of the manufacturer easily and without any ambiguity, — the unique identification code of the product-type, — the reference number of the declaration of performance, — the level or class of the performance declared, — the dated reference to the harmonized technical specification applied, — the identification number of the notified body (only for products under system 3), — the intended use as laid down in the harmonized technical specification applied The CE marking shall be affixed before the construction product is placed on the market It may be followed by a pictogram or any other mark notably indicating a special risk or use Figures ZA.1 to ZA.2 give examples of the information related to products subject to AVCP under system 41 BS EN 12058:2015 EN 12058:2015 (E) The following gives an example of a filled-in CE-Mark for slabs of granite named SEEBACH GRANIT (Type 1234) for internal uses for slabs for floors and stairs, produced by the manufacturer AnyCo SA CE marking, consisting of the “CE”-symbol Identification number of the notified test laboratory 8765 AnyCo Ltd, PO Box 21, B-1050 Brussels 15 003CPR2014–04 name and the registered address of the manufacturer, or identifying mark Last two digits of the year in which the marking was first affixed Reference number of the DoP EN 12058:2015 SEG 4549 Natural stone slabs used as internal flooring and stairs Reaction to fire: Class A 1FL Flexural strength: - lower expected value: 11 MPa - mean value: 14 MPa - standard deviation: 1,4 MPa Slip resistance - sawn surface (SRV “wet”,“dry“): 65, 85 - honed surface (C 120) (SRV “wet”,“dry“):55, 75 Tactility: None Direct airborne sound insulation - mean value: 2750 kg/m Thermal conductivity - mean value: W/(mK) Release of radioactivity: Release of dangerous substances: - No of European Standard applied, as referenced in OJEU Unique identification code of the producttype Intended use of the product as laid down in the European Standard applied Level or class of the performance declared Figure ZA.1 — Example CE marking information of products for internal use under AVCP system 42 BS EN 12058:2015 EN 12058:2015 (E) The following gives an example of a filled-in CE-Mark for slabs of granite named SEEBACH GRANIT (Type 1234) for external uses for slabs for floors and stairs, produced by the manufacturer AnyCo SA CE marking, consisting of the “CE”-symbol Identification number of the notified test laboratory 8765 AnyCo Ltd, PO Box 21, B-1050 Brussels 15 004CPR2014–04 name and the registered address of the manufacturer, or identifying mark Last two digits of the year in which the marking was first affixed Reference number of the DoP EN 12058:2015 SEG 4549 Natural stone slabs used as external flooring and stairs Flexural strength: - lower expected value: 11 MPa - mean value: 14 MPa - standard deviation: 1,4 MPa Slip resistance - sawn surface (SRV “wet”,“dry“): 65, 85 - honed surface (C 120) (SRV “wet”,“dry“): 55, 75 Tactility: None Durability of flexural strength against freeze thaw - mean value before freeze thaw: 14 MPa - mean value after freeze thaw: 13 MPa No of European Standard applied, as referenced in OJEU Unique identification code of the producttype Intended use of the product as laid down in the European Standard applied Level or class of the performance declared Figure ZA.2 — Example CE marking information of products for external use under AVCP system 43 BS EN 12058:2015 EN 12058:2015 (E) Bibliography [1] EN 771-6, Specification for masonry units - Part 6: Natural stone masonry units [2] EN 1341, Slabs of natural stone for external paving - Requirements and test methods [3] EN 1342, Setts of natural stone for external paving - Requirements and test methods [4] EN 1343, Kerbs of natural stone for external paving - Requirements and test methods [5] EN 12326-1, Slate and stone for discontinuous roofing and external cladding - Part 1: Specifications for slate and carbonate slate [6] EN 12326-2, Slate and stone for discontinuous roofing and external cladding - Part 2: Methods of test for slate and carbonate slate [7] EN 13161, Natural stone test methods - Determination of flexural strength under constant moment [8] EN 14158, Natural stone test methods - Determination of rupture energy [9] CEN/TS 15209, Tactile paving surface indicators produced from concrete, clay and stone [10] CEN/TS 00351014 5, Construction products — Assessment of release of dangerous substances — Measurement of activity concentrations of gamma radiation) [11] Commission Decision 96/603/EC of October 1996 establishing the list of products belonging to Classes A 'No contribution to fire' provided for in Decision 94/611/EC implementing Article 20 of Council Directive 89/106/EEC on construction products, OJ L 267, 19.10.1996, p 23–26 [12] ASTM D5873, Standard Test Method for Determination of Rock Hardness by Rebound Hammer Method 5) 44 under preparation This page deliberately left blank NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW British Standards Institution (BSI) BSI is the national body responsible for preparing British Standards and other standards-related publications, information and services BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited About us Revisions We bring together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions Our British Standards and other publications are updated by amendment or revision The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process Organizations of all sizes and across all sectors choose standards to help them achieve their goals Information on standards We can provide you with the knowledge that your organization needs to succeed Find out more about British Standards by visiting our website at bsigroup.com/standards or contacting our Customer Services team or Knowledge Centre Buying standards You can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at bsigroup.com/shop, where hard copies can also be purchased If you need international and foreign standards from other Standards Development Organizations, hard copies can be ordered from our Customer Services team Subscriptions Our range of subscription services are designed to make using standards easier for you For further information on our subscription products go to bsigroup.com/subscriptions With British Standards Online (BSOL) you’ll have instant access to over 55,000 British and adopted European and international standards from your desktop It’s available 24/7 and is refreshed daily so you’ll always be up to date You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single copy and subscription format, by becoming a BSI Subscribing Member PLUS is an updating service exclusive to BSI Subscribing Members You will automatically receive the latest hard copy of your standards when they’re revised or replaced To find out more about becoming a BSI Subscribing Member and the benefits of membership, please visit bsigroup.com/shop With a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet Licences can cover as few or as many users as you wish With updates supplied as soon as they’re available, you can be sure your documentation is current For further information, email bsmusales@bsigroup.com BSI Group Headquarters 389 Chiswick High Road London W4 4AL UK We continually improve the quality of our products and services to benefit your business If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please inform the Knowledge Centre Copyright All the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that owns copyright in the information used (such as the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means – electronic, photocopying, recording or otherwise – without prior written permission from BSI Details and advice can be obtained from the Copyright & Licensing Department Useful Contacts: Customer Services Tel: +44 845 086 9001 Email (orders): orders@bsigroup.com Email (enquiries): cservices@bsigroup.com Subscriptions Tel: +44 845 086 9001 Email: subscriptions@bsigroup.com Knowledge Centre Tel: +44 20 8996 7004 Email: knowledgecentre@bsigroup.com Copyright & Licensing Tel: +44 20 8996 7070 Email: copyright@bsigroup.com

Ngày đăng: 14/04/2023, 00:24

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN