Microsoft Word 2 2E Errata Date of Issue November 11, 2009 Affected Publication API MPMS Chapter 2 2E, Petroleum and Liquid Petroleum Products—Calibration of Horizontal Cylindrical Tanks, Part 1 Manua[.]
Date of Issue: November 11, 2009 Affected Publication: API MPMS Chapter 2.2E, Petroleum and Liquid Petroleum Products—Calibration of Horizontal Cylindrical Tanks, Part 1: Manual Methods, First Edition, April 2004 ERRATA Page 8, Clause 15 At the end of the first sentence, replace “can be neglected” with “can be neglected if E/D is less than 0,012” At the end of the paragraph, replace “normative annex A” with “Annex A” Page 14, Figure A.1: Replace items and in the key with the following: Key Value of H/D: 0,5 to 0,999 — subtract volume correction when the tank is more than half full Value of H/D: 0,001 to 0,5 — add volume correction when the tank is less than half full