1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Astm g 192 08 (2014)

10 0 0

Đang tải... (xem toàn văn)

THÔNG TIN TÀI LIỆU

Nội dung

Designation G192 − 08 (Reapproved 2014) Standard Test Method for Determining the Crevice Repassivation Potential of Corrosion Resistant Alloys Using a Potentiodynamic Galvanostatic Potentiostatic Tech[.]

Designation: G192 − 08 (Reapproved 2014) Standard Test Method for Determining the Crevice Repassivation Potential of Corrosion-Resistant Alloys Using a PotentiodynamicGalvanostatic-Potentiostatic Technique1 This standard is issued under the fixed designation G192; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision A number in parentheses indicates the year of last reapproval A superscript epsilon (´) indicates an editorial change since the last revision or reapproval Scope Determine the Precision of a Test Method G1 Practice for Preparing, Cleaning, and Evaluating Corrosion Test Specimens G5 Reference Test Method for Making Potentiodynamic Anodic Polarization Measurements G15 Terminology Relating to Corrosion and Corrosion Testing (Withdrawn 2010)3 G48 Test Methods for Pitting and Crevice Corrosion Resistance of Stainless Steels and Related Alloys by Use of Ferric Chloride Solution G61 Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements for Localized Corrosion Susceptibility of Iron-, Nickel-, or Cobalt-Based Alloys G78 Guide for Crevice Corrosion Testing of Iron-Base and Nickel-Base Stainless Alloys in Seawater and Other Chloride-Containing Aqueous Environments 1.1 This test method covers a procedure for conducting anodic polarization studies to determine the crevice repassivation potential for corrosion–resistant alloys The concept of the repassivation potential is similar to that of the protection potential given in Reference Test Method G5 1.2 The test method consists in applying successively potentiodynamic, galvanostatic, and potentiostatic treatments for the initial formation and afterward repassivation of crevice corrosion 1.3 This test method is a complement to Test Method G61 1.4 The values stated in SI units are to be regarded as the standard The values given in parentheses are for information only 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use Terminology 3.1 Definitions—For definitions of corrosion-related terms used in this test method, see Terminology G15 Summary of Test Method Referenced Documents 4.1 This anodic polarization test method combines techniques such as potentiodynamic, galvanostatic, and potentiostatic polarization methods This test method is called the Tsujikawa-Hisamatsu Electrochemical (THE) test method to honor the two precursors of this technique (see and 2).4 The new technique will be called the THE test method This new THE test method is more time-consuming than the already well-established cyclic potentiodynamic polarization (CPP) described in Test Method G61 2.1 ASTM Standards:2 B575 Specification for Low-Carbon Nickel-ChromiumMolybdenum, Low-Carbon Nickel-ChromiumMolybdenum-Copper, Low-Carbon Nickel-ChromiumMolybdenum-Tantalum, Low-Carbon Nickel-ChromiumMolybdenum-Tungsten, and Low-Carbon NickelMolybdenum-Chromium Alloy Plate, Sheet, and Strip D1193 Specification for Reagent Water E691 Practice for Conducting an Interlaboratory Study to 4.2 The THE test method can be used with any corrosion–resistant alloy, but it was developed by studying Alloy 22 (UNS N06022) The composition and other properties of Alloy 22 are given in Specification B575 Alloy 22 is a nickel–based alloy containing approximately 22wt% Cr, 13wt% Mo, 3wt% This test method is under the jurisdiction of ASTM Committee G01 on Corrosion of Metals and is the direct responsibility of Subcommittee G01.11 on Electrochemical Measurements in Corrosion Testing Current edition approved Nov 1, 2014 Published November 2014 Originally approved in 2008 Last previous edition approved in 2008 as G192–08 DOI: 10.1520/G0192-08R14 For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org For Annual Book of ASTM Standards volume information, refer to the standard’s Document Summary page on the ASTM website The last approved version of this historical standard is referenced on www.astm.org The boldface numbers in parentheses refer to a list of references at the end of this standard Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959 United States G192 − 08 (2014) other test methods to measure localized corrosion resistance such as Test Method G61 and Test Methods G48 The results from this test method are not intended to correlate in a quantitative manner with the rate of propagation that one might observe in service when localized corrosion occurs W and 3wt% Fe The THE test method is a complement to the cyclic potentiodynamic polarization (CPP) described in Test Method G61 CPP may be used as a first fast screening method and THE test method for fine-tuning the repassivation potential for crevice corrosion when the environment is not highly aggressive (3-6) The THE test method has also been applied to other highly corrosion–resistant alloys, such as Titanium grade (Ref 7) 5.3 This test method may be used to rank several alloys by using the same testing electrolyte and temperature It can also be used to determine the response of a given alloy when the environmental conditions (such as electrolyte composition and temperature) change 4.3 The THE test method can be used with any electrolyte solution A standard M NaCl solution at 90°C or lower temperature may be used to compare alloys of interest The round robin described in Section 15 was carried out in M NaCl solution at 90°C Apparatus 6.1 Cell—The polarization cell should be similar to the one described in Reference Test Method G5 and Test Method G61 Other polarization cells may be equally suitable The cell should have a capacity of about L and should have suitable necks or seals to permit the introduction of electrodes, gas inlet and outlet tubes, and a thermometer or thermocouple The Luggin probe-salt bridge separates the bulk solution from the saturated calomel or saturated silver chloride reference electrode 4.4 The test involves in polarizing the test electrode in three steps: 4.4.1 Step 1—The test electrode is polarized potentiodynamically at a rate of 0.168 mV/s (as in Test Method G61) starting at or slightly below the corrosion potential until a preset current (or current density) is reached (for example, µA ⁄cm2) After this initial potentiodynamic polarization, the polarization control is changed to galvanostatic mode (Step 2) 4.4.2 Step 2—The preset current of µA/cm2 is kept constant for a 2-h period to develop and grow a crevice corroded area (if any develops) During the galvanostatic Step 2, the potential output is monitored 4.4.3 Step 3—The polarization control is shifted to the potentiostatic mode The potential at the end of the galvanostatic hold (Step 2) is read, and then 10 mV are subtracted The resulting value of potential is applied for a 2-h period while the current output is monitored Then successive potentiostatic treatments are applied, each time at 10 mV lower than the previous treatment A total of 10-15 potentiostatic treatments are usually required to finish Step 6.2 Test Electrode (Specimen) Holder—The test electrode holder and the mounting rod should be similar to the one described in Figure in Reference Test Method G5 (reproduced in Fig 1) A leakproof PTFE compression gasket, as described in subsection 4.6.1 in Reference Test Method G5, is also necessary 6.3 Potentiostat and Output Potential and Current Measuring Instruments—The potentiostat and other instruments should be similar to the ones specified in Test Method G61 Most commercial potentiostat and related instruments meet the specific requirements for these types of measurements 6.4 Electrodes—The standard recommended working or testing electrode is shown in Fig 1, which is a prismatic measuring 0.75 by 0.75 by 0.375-in thick (approximately 20 by 20 by 10 mm) It has a drilled and tapped hole on top for the connecting rod (as in Reference Test Method G5) The electrodes also have a 7-mm diameter hole in the center for mounting two crevice formers, one at each side using a bolt The test electrode could be cut from any plate or extruded bar It is recommended that the creviced faces of the test electrode correspond to the rolling or extruded direction In certain tested conditions the test electrode may show end grain attack in the short transverse direction, but generally the crevice former provides a more active path for corrosion than the freely exposed surfaces 4.5 The crevice repassivation potential (ER,CREV) is the highest potential in Step for which current density does not increase as a function of time It is understood that at a potential below ER,CREV the alloy will not develop crevice corrosion under the tested conditions Significance and Use 5.1 The THE test method is designed to provide highly reproducible crevice repassivation potentials for corrosion–resistant alloys (for example, Alloy 22) in a wide range of environments from non-aggressive to highly aggressive In conditions of low environmental aggressiveness (such as low temperature or low chloride concentration), corrosion–resistant alloys such as Alloy 22 will resist crevice corrosion initiation and the cyclic potentiodynamic polarization test (Test Method G61) may fail to promote crevice corrosion mainly because it drives the alloy into transpassive dissolution instead of nucleating crevice corrosion The THE test method provides a more controlled way of applying the electrical charge to the test electrode, which may induce crevice corrosion without moving it into transpassive potentials 6.5 Crevice Former or Crevice Washer—The crevice former is a multiple crevice assembly (MCA), and it is described in subsection 5.4 of Test Methods G48, in subsection 9.2.2 in Guide G78, and in Ref This MCA crevice former should be fabricated using a hard non-conductive ceramic material such as alumina or mullite (Fig 2) Before mounting on the test electrode (specimen), the crevice washers should be covered with a PTFE tape This tape is 1.5-in wide and 0.003-in thick (standard military grade MIL-T-27730A) A corrosion–resistant fastener is used to secure the two MCA washers, one on each side of the test electrode Crevice formers made of solid 5.2 The more noble this crevice corrosion repassivation potential (ER,CREV) value, the more resistant the alloy is to crevice corrosion in the tested electrolyte This is similar to G192 − 08 (2014) FIG Prismatic Test Electrode (0.75 by 0.75 by 0.375 in or approximately 20 by 20 by 10 mm) to a platinum foil, which could be curved to adapt to the cell geometry It is recommended that the area of the platinum counter electrode be twice as large as the one of the working electrode (test electrode or specimen) 6.7 Reference Electrode—Reference electrodes could be commercially available saturated calomel or silver-silver chloride These electrodes are durable and reliable; however, they should be maintained in the proper conditions The potential of the reference electrodes should be checked at periodic intervals to ensure their accuracy PTFE such as in Test Methods G48 or Guide G78 are not as effective, since they not form a crevice gap tight enough for certain high end corrosion–resistant materials This may result in higher and poorly reproducible repassivation potential values Two standard metal washers are used as well (Figs and 2) The standard pressure on the MCA crevice formers may vary (depending of the study underway) but a minimum of 30-in.·lb (3.4-N·m) torque may be needed to form a tight crevice Use a calibrated torque wrench to apply the torque Electrical contact between the bolt and the test electrode should be avoided Effective insulation may be provided by the use of nonmetallic sleeves or by wrapping the assembly bolt with PTFE tape Reagents and Materials 7.1 Purity of Reagents—Reagent grade chemicals should be used in all tests 7.2 Purity of Water—The water should be distilled or deionized conforming to the requirements of Specification D1193, Type IV reagent water 6.6 Counter Electrode—The counter electrodes may be prepared as in Reference Test Method G5 or may be prepared from high-purity platinum flat stock and wire Counter electrodes could be easily fabricated by spot welding platinum wire G192 − 08 (2014) FIG Prismatic Test Electrode (0.75 by 0.75 by 0.375 in or approximately 20 by 20 by 10 mm) (continued) 7.3 Sodium Chloride (NaCl)—To prepare L of M NaCl solution, dissolve 58.45 g of NaCl in purified water to obtain a total volume of solution of L of maintaining parallel/prismatic surfaces cannot be overstated with regard to reproducing crevice conditions and the prevention of possible fracture of the ceramic devices 7.4 Purging Gas—If deaeration is necessary, nitrogen gas of a minimum 99.99 purity should be used Tests could also be run under normal aeration conditions or under any other atmosphere 9.3 The test electrodes could be prepared using wrought or cast material, or machined weld metal 9.4 The bolt, nut, and flat washer must be made of a corrosion–resistant material It is recommended to use Ti Gr (UNS R52400) Fastening devices can also be fabricated using other readily available materials such as Alloys C-276 and 625 (UNS N10276 and N06625, respectively) The crevice former is manufactured using a ceramic material according to the 12-tooth design in Test Methods G48, Guide G78, and Ref (Fig 2) The ceramic washer is covered by a wide PTFE tape 1.5-in wide and 0.003-in thick (standard military grade MIL-T-27730A) 7.5 Prismatic-Shaped Test Electrodes of the Corrosion–Resistant Alloy—Other type of creviced test electrodes may also be used, depending on the specific study being performed Hazards 8.1 Normal precautions for handling hot liquids should be observed 8.2 Personal protective equipment for handling hot liquids should be used 10 Preparation of Apparatus Sampling, Test Electrodes, and Test Units 10.1 The testing cell and test electrode holder are described in Reference Test Method G5 9.1 Recommended test electrodes (specimens) are prismatic-shaped as shown in Fig The thickness of the material for the test electrodes is not essential, but it should be enough to handle the mounting rod mechanism Thicker materials are easier to prepare (polish) A fresh (or h prior to testing) finish wet grinding of 600 grit silicon carbine paper is recommended If surface effects are being studied, other surface finishing may be considered 10.2 The potentiostat and other instruments should be similar to the ones specified in Test Method G61 Most commercial potentiostat and related instruments meet the specific requirements for these types of measurements 11 Calibration and Standardization 11.1 The potentiostat and its software should be calibrated in accordance with user calibration procedures The good operating conditions of the potentiostat can also be assessed using the Reference Test Method G5 procedure 9.2 If other than mill finishes are investigated, the test electrodes may be reused after remachining or grinding to remove all traces of previously incurred attack The importance G192 − 08 (2014) NOTE 1—Includes Fig from Reference Test Method G5 to describe how the test electrode is attached to the specimen holder FIG Crevice Formers for the Test Electrode G192 − 08 (2014) 12.13 The highest potential step for which the current does not increase as a function of time is the Crevice Repassivation Potential, ER,CREV 12 Procedure 12.1 Test electrode preparation, cleaning and mounting Practice G1 is to be followed where applicable, unless otherwise stated in this procedure 12.14 Fig shows an example of the representation of the current and potential values as a function of the testing time, outlining the potentiodynamic, galvanostatic, and potentiostatic sections of the test 12.2 Wet grind the test electrode to a surface finish of 600 grit silicon carbide paper (Other variations may be used if the studied variable, for example, is surface finish.) 12.15 After the test is complete, carefully remove the test electrode from the cell, remove the crevice former, and rinse in running water Let it dry in air 12.3 Surface finishing should be carried out not longer than h prior to testing The test electrode should be then degreased in alcohol or other solvents and rinsed in deionized water and air-dried After degreasing, handle the test electrode with clean gloves, soft clean tongs, or equivalent preventive measures to avoid surface contamination 12.16 Inspect the test electrode for crevice corrosion or other type of localized attack under at least a 20× magnification stereomicroscope 12.4 Mount the crevice formers on the test electrode using a calibrated wrench with torque indicator The ceramic crevice formers should be pre-coated with the PTFE tape Apply the specified torque (for example, 30-in.·lb or 3.4-N·m) to the securing bolts avoiding the crevice former to slide (rotate) across the surface of the test electrode 13 Calculation or Interpretation of Results 13.1 The inspection of the test electrode should show if it suffered crevice corrosion or other type of localized attack 13.2 The value of the Crevice Repassivation Potential (ER,CREV) should be interpreted according to the evidence that the test electrode suffered or did not suffer crevice corrosion according to 13.1 The value of ER,CREV is the average value of all the creviced spots on the tested specimen, for example, if 24 sites corroded, the value of ER,CREV will represent a composed value of the 24 sites 12.5 Add 900 mL of the M NaCl solution (or other testing electrolyte) to the cell and if necessary purge for h with nitrogen while the cell is being brought to temperature (for example, 90°C) The purging gas rate is commonly set at 100 cc/min 14 Report 12.6 Insert the test electrode into the cell, and connect the leads to the potentiostat 14.1 At a minimum, report the following information: 14.1.1 Alloy tested, common denomination, and UNS number, if available Also report alloy (metal) composition 14.1.2 Metallurgical condition (for example, welded, thermally aged, wrought, or non-welded, etc.) and type of surface condition or finish (for example, fresh 600 grit paper or high temperature oxidized) 14.1.3 Torque applied to the test electrodes (see 12.4) 14.1.4 Potentiostat and software used, report also date and procedure of calibration (see 11.1) 14.1.5 Type of reference electrode used and how the reference electrode was checked for accuracy (calibrated) 14.1.6 Testing electrolyte and temperature (for example, deaerated M NaCl at 90°C) Report if the electrolyte was deaerated or not (see 7.4) 14.1.7 Initial pH of the electrolyte 14.1.8 The value of the applied current in the galvanostatic step and the duration of application (see 12.9) 14.1.9 Attach to the report a graph of potential and current versus time similar to Fig at the end of this test method 14.1.10 Report the value of the Crevice Repassivation Potential (ER,CREV) in millivolts (mV) specifying the reference electrode used (see 6.7) 14.1.11 Characteristics of the corroded test electrode (for example, type of attack, if crevice corrosion, how many of the 24 creviced sites were attacked, etc.) It would be useful to include an image of the corroded test electrode 12.7 Monitor the open circuit potential for h while nitrogen is purged through the electrolyte (Other monitoring times, for example, 24 h or week, could also be used for other test purposes or electrolytes.) 12.8 After the 1-h nitrogen treatment, apply a potentiodynamic anodic polarization at a scan rate of 0.167 mV/s starting 100 mV below the open-circuit potential and progressing anodically until a pre-specified current (or current density) is reached The threshold current density is set at µA/cm2, but other values may be used depending on the type of alloy and aggressiveness of the electrolyte 12.9 Switch the anodic polarization control mode to galvanostatic and apply the end current (for example, µA/cm2 ) for h to grow the crevice corroded area Monitor the output potential values 12.10 Switch the anodic polarization control mode to potentiostatic mode and apply the end potential in the previous step minus 10 mV That is, if at the end of step 12.9 the potential was 400 mV, in step 12.10 apply 390 mV and monitor the evolution of the current for h 12.11 If the current increases with time during the step 12.10, apply another potentiostatic period of h subtracting another 10 mV to the previously applied potential Following the example in 12.10, in this second step apply 380 mV This treatment could be preset using commercial software for electrochemical testing 15 Precision and Bias 12.12 Repeat decreasing steps of 10 mV until the output current decreases with time in the 2-h period (Fig 3) 15.1 Under some testing conditions results from this method may be comparable to results from Test Method G61 The G192 − 08 (2014) NOTE 1—ER,CREV is the potential at which the current density decreases as function of time The top image is from FIG Example of a THE Representation current THE test method is meant to be a complement to Test Method G61 (see also Refs 3-6) The THE test method may produce crevice corrosion in conditions where Test Method G61 has limitations results Ten laboratories initially agreed to participate in this round-robin test to which the testing protocol and test electrodes were sent At the end, five laboratories returned the results Results from the round robin are in Ref 15.2 An interlaboratory study (ILS) test program (roundrobin) was completed to determine repeatability of the test 15.3 For the round-robin tests, Alloy 22 was exposed in deaerated M NaCl solution at 90°C The corrosion potential G192 − 08 (2014) FIG Repassivation Potential from the Five Laboratories that Reported Values from the Round Robin test reproducible Fig shows the corroded test electrode THE51 from Laboratory Crevice corrosion developed under the crevice formers NOTE 1—The drop in current at the sixth potentiostatic step clearly shows that the repassivation potential for this test was -100 mV FIG Repassivation Potential for Specimen THE30 from Laboratory 15 15.6 The precision of the procedure in the THE test method was determined in an inter laboratory test program with five laboratories running tests with one lot of Alloy 22 These laboratories ran replicate tests with three to six tests as shown in Table The precision was calculated using a modification of the procedure shown in Practice E691 to account for the fact that different numbers of replicates were used 15.6.1 Precision consists of two components: 15.6.1.1 Repeatability—is the agreement that occurs when identical test electrodes are run sequentially with the same test method by the same laboratory and the same operator and equipment 15.6.1.2 Reproducibility—refers to the agreement that occurs when identical test electrodes are run with the same test method but in different laboratories was waited for h The total applied current in the galvanostatic step was µA/cm2 (30 µA for a 14.06 cm2 surface area test electrode) The test electrode was the prismatic shape (Fig 1) with freshly wet ground surface The applied torque to the crevice formers was 70 in.·lb (7.9 N·m) 15.4 Prismatic test electrodes were ordered from a single supplier and were distributed five test electrodes to each of the ten different laboratories Hardware for mounting the test electrodes (Fig 2) were also supplied to the laboratories Five laboratories returned the results from the round robin test Fig shows one of the typical results from the tests This corresponded to Specimen THE30 from Laboratory 15 Fig shows the repassivation potential for the 6th potentiostatic step for which the current dropped The repassivation potential for this test was -100 mV SSC 15.7 The interlaboratory test program produced repeatability statistics consisting of the repeatability standard deviation sr and the 95% confidence interval r, where r = 2.8 sr These values were found to be as shown below for the Alloy 22 test electrodes tested: sr = 610.2 mV r = 628.6 mV 15.5 The results from all five laboratories are listed in Table and Fig The overall crevice repassivation potential for Alloy 22 in M NaCl at 90°C from the five laboratories was -107 mV SSC and the standard deviation was 10.0 mV This low standard deviation shows that the measurement of the repassivation potential using the THE test method is highly 15.8 The interlaboratory program produced reproducibility statistics including the reproducibility standard deviation SR, and the 95% confidence interval for reproducibility, R, where R = 2.8 SR These values were found to be as shown below for the Alloy 22 test electrodes: sR = 610.6 mV R = 629.7 mV TABLE Repassivation Potential Results from the Round Robin Individual Repassivation Potential Values (mV, Saturated Silver Chloride Scale) Average Standard Deviation Lab Lab Lab 15 Lab 13 Lab Overall (all labs) –111 –106 –116 –112 –119 –114 –135 –110 –112 –112.8 –117.8 11.6 –82 –82 –97 –94 –102 –95 –102 –125 –100 –106 –91 –110 –92 –109 –102.3 –106.8 8.2 13.9 10.0 10.0 15.9 The procedure in the THE test method has no bias because the repassivation potential determined by this method is defined only in terms of this method NOTE 1—Test Method G61 also produces a repassivation potential value However, the magnitude of the repassivation potential values obtained in Test Method G61 may vary significantly depending upon the G192 − 08 (2014) NOTE 1—Attack occurred under all of the twelve footprints of the MCA White areas around the footprints (mainly at and o’clock) are deposits of salts or corrosion products The letters THE51 represent the specimen ID FIG Example of Crevice Corrosion affecting Alloy 22 test electrodes in the THE Round Robin Test scan rate and other factors In some cases significantly higher repassivation potentials were found with Test Method G61 than with the THE test method 16 Keywords 16.1 corrosion–resistant alloys; crevice repassivation potential; electrochemical test REFERENCES Galvanostatic-Potentiostatic Method,” Paper NN3.13, Proceedings of the Materials Research Society Fall Meeting, Vol 985, Boston, Massachusetts, Nov 27 through Dec 1, 2006, pp 313-220 (6) Evans, K J., and Rebak, R B., “Measuring the Repassivation Potential of Alloy 22 Using the Potentiodynamic-GalvanostaticPotentiostatic Method,” Journal of ASTM International, Vol 4, No 9, Paper ID JAI101230, October 2007 (From the proceedings of the ASTM symposium on “Advances in Electrochemical Techniques for Corrosion Monitoring and Measurement,” Norfolk, Virginia, May 22 through 23.) (7) Evans, K J., and Rebak, R B., “Anodic Polarization Behavior of Titanium Gr in Dust Deliquescence Salt Environments,” Paper PVP200726161, Proceedings of the ASME Pressure Vessels and Piping Conference, Vol 7, San Antonio, Texas, July 22 through 27, 2007, pp 387–394 (1) Tsujikawa, S., and Hisamatsu, Y., Corrosion Engineering, Japan, 29, 37, 1980 (2) Akashi, M., Nakayama, G., and Fukuda, T., Corrosion/98, Paper 98158, NACE International, Houston, Texas, 1998 (3) Evans, K J., Wong, L L., and Rebak, R B., “Determination of the Crevice Repassivation Potential of Alloy 22 by a PotentiodynamicGalvanostatic-Potentiostatic Method,” Proceedings of the ASME, Pressure Vessel and Piping Conference, Vol 483, American Society of Mechanical Engineers, New York, NY, 2004, pp 137-149 (4) Evans, K J., Yilmaz, A., Day, S D., Wong, L L., Estill, J C., and Rebak, R B., “Using Electrochemical Methods to Determine Alloy 22’s Crevice Repassivation Potential,” Journal of Metals, January 2005, pp 56-61 (5) Evans, K J., and Rebak, R B., “Repassivation Potential of Alloy 22 in Chloride plus Nitrate Solutions Using the Potentiodynamic- G192 − 08 (2014) (8) Kain, R M., “Evaluating Crevice Corrosion,” Corrosion: Fundamentals, Testing and Protection, Vol 13A, ASM Handbook, ASM International, 2003, pp 549-561 ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website (www.astm.org) Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222 Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http://www.copyright.com/ 10

Ngày đăng: 12/04/2023, 16:30

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN