1. Trang chủ
  2. » Tất cả

Astm a 861 04 (2013)

26 1 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Nội dung

Designation A861 − 04 (Reapproved 2013) Standard Specification for High Silicon Iron Pipe and Fittings1 This standard is issued under the fixed designation A861; the number immediately following the d[.]

Designation: A861 − 04 (Reapproved 2013) Standard Specification for High-Silicon Iron Pipe and Fittings1 This standard is issued under the fixed designation A861; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision A number in parentheses indicates the year of last reapproval A superscript epsilon (´) indicates an editorial change since the last revision or reapproval Scope Quarter Bends Sixth Bends Return Bends Double-Branch Quarter Bend Eighth Bends Sixteenth Bends Long-Sweep Quarter Bends Sanitary Y Branches Double-Branch Sanitary Y Sanitary Combination Y and 1⁄8 Bend Double-Branch Sanitary Combination Y and 1⁄8 Bend Sanitary T Branches Double Branch Sanitary T Sanitary Running Traps Sanitary P Traps Swivel Trap P-Style Short Swivel Trap P-Style Long Swivel Trap S-Style Long Centrifugal Drum Trap P Swivel Type Centrifugal Drum Trap S Swivel Type Combination Cleanout and Test Tees Coupling Pipe Plugs Cleanout Plugs No-hub (MJ) Adapter Reducers—Increasers Sink Outlet Sink Overflows Threaded Adapters Trap Cleanout Details No-hub (MJ) Adapter (MJ) (No-hub) to Lead Adapter Floor Drains 1.1 This specification covers high-silicon iron pipe and pipe fittings intended for corrosion-resistant service for both aboveand below-grade construction 1.2 The values stated in inch-pound units are to be regarded as standard The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard 1.3 Pipe and pipe fittings shall be the no-hub (MJ) or the hub and plain end design 1.4 Pipe and pipe fittings shall be of the sizes specified in Table and Table and Figs 1-71 or other sizes that shall be permitted to conform to the requirements given herein 1.4.1 Pipe: 1.4.1.1 No-hub (MJ) (Fig 1): Size (in.) 11⁄2 Length (ft) 7 7 1.4.1.2 Hub/Plain End (Fig.35): Size (in.) 10 12 15 Length (ft) 7 7 5 Figs 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 1.4.3 Fitting (Hub/Plain End): Hub Plain End Pipe Straight Tees Sanitary T Branches Sanitary Y Branches Double-Branch Sanitary Tee Double-Branch Sanitary Y Double-Branch Sanitary Combination Y and 1⁄8 Bend (T-Y) Short-Sweep Quarter Bends Long-Sweep Quarter Bends Sanitary Combination Y and 1⁄8 Bend (T-Y) Quarter Bends 1.4.2 Fitting (No-hub) (MJ): This specification is under the jurisdiction of ASTM Committee A04 on Iron Castings and is the direct responsibility of Subcommittee A04.12 on Pipes and Tubes Current edition approved May 1, 2013 Published July 2013 Originally approved in 1986 Last previous edition approved in 2008 as A861 – 04 (2008) DOI: 10.1520/A0861-04R13 Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959 United States Figs 35 36 37 38 39 40 41 42 43 44 45 A861 − 04 (2013) Sixth Bends Eighth Bends Sixteenth Bends Sanitary Increasers Hub Strainers Sanitary Reducers Double Hubs Pipe Plugs Cleanout Plugs Adapter—Plain end to Split Flange Adapter—Hub to-Split Flange Combination Cleanout and Test Tees Insertable Joints Backwater Valves Sanitary P Traps Sanitary S Traps Sanitary Running Traps Floor Drains Floor Drains Floor Drains/Installation—Funnel Attachment Overflow Sink Outlet Detailed Cross Section of Cleanout Chemical Composition Transverse Bend Test Minimum Requirements TABLE Tolerances for High-Silicon Iron Fittings 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63, 64, 65 66 67, 68 69 70 71 Table Table S1.1 NOTE 1—1 in = 25.4 mm Size, in 11⁄2 1⁄ 2 2× 2× 3× 3× 3× 4× 4× 4× 4× × 1⁄ 11⁄2 11⁄2 11⁄2 ID Tolerance, in OD Tolerance, in Stop Lug Depth Tolerance, in ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 ±1⁄16 TABLE Chemical Composition Composition, Weight % Element Referenced Documents Carbon Manganese Silicon Chromium Molybdenum Copper 2.1 ASTM Standards:2 A518/A518M Specification for Corrosion-Resistant HighSilicon Iron Castings E350 Test Methods for Chemical Analysis of Carbon Steel, Low-Alloy Steel, Silicon Electrical Steel, Ingot Iron, and Wrought Iron E351 Test Methods for Chemical Analysis of Cast Iron—All Types 2.2 Other Standards: Uniform Classification Rules3 National Motor Freight Classification3 Grade Grade 0.65–1.10 1.50 max 14.20–14.75 0.50 max 0.50 max 0.50 max 0.75–1.15 1.50 max 14.20–14.75 3.25–5.00 0.40-0.60 0.50 max Terminology 3.1 Definitions of Terms Specific to This Standard: 3.1.1 hubless—a pipe or fitting without a hub, sometimes called no-hub, joined by a coupling 3.1.2 MJ—an abbreviation for mechanical joint 3.1.3 no-hub—a pipe or fitting without a hub, sometimes described as hubless joined by a coupling 16 ⁄ ⁄ 5⁄16 5⁄16 16 4.1 Ordering for material under this specification shall include as a minimum the following information: 4.1.1 ASTM designation, grade (see Table 3) and year of issue 4.1.2 Description of the casting by figure number (see Figs through 71) or by manufacturer’s drawings or catalog number, or both 4.1.3 Length, diameter, and type of pipe and size and shape of fittings 4.1.4 Quantity 4.1.5 Certification requirements 4.1.6 Special packaging requirements (see Section 14) Wall Thickness, in ID Tolerance, in OD Tolerance, in ±1⁄32 ±1⁄32 ±1⁄32 ±1⁄32 ± 1⁄ ± 1⁄ ± 1⁄ ± 1⁄ t, in 84 84 84 84 Ordering Information NOTE 1—1 in = 25.4 mm ±1⁄32 ±1⁄32 ±1⁄32 ±1⁄32 ±1⁄32 ±1⁄8 ±1⁄8 ±1⁄8 F, in 23⁄16 (2.19) 211⁄16 (2.69) 349⁄64 (3.77) 449⁄64 (4.77) FIG No-Hub Pipe (MJ) TABLE Tolerances for High-Silicon Iron Hub/Plain-End Pipe 10 12 15 J, in 1⁄ 2 NOTE 1—1 in = 25.4 mm For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org For Annual Book of ASTM Standards volume information, refer to the standard’s Document Summary page on the ASTM website Available from American Trucking Association, 950 North Glebe Road, Suite 210, Arlington, VA 22203-4181 Size, in Size, in ±1⁄32 ±1⁄32 ±1⁄32 ±3⁄64 ± 1⁄ ± 1⁄ ± 1⁄ ± 1⁄ A861 − 04 (2013) 5.2 The castings shall be true to pattern, reasonably smooth, and free from defects that would make the castings unfit for the use for which they are intended Chemical Composition Size, in 1⁄ 2 × 11⁄2 D, in ID, in 1⁄ 41 ⁄ 43⁄16 × 41⁄2 51 ⁄ 1⁄ 2 × 11⁄2 6.1 An analysis of each heat shall be made by the manufacturer from a test sample that is representative of the heat and that is taken during the heat A heat shall consist of all castings poured from a furnace or crucible melt without recharging new metal into the furnace The chemical composition thus determined shall conform to the requirements for the grade selected specified in Table Stop Lug Depth (P), in OD, in 23⁄16 (2.19) 25⁄8 (2.62) 25⁄8 × 23⁄16 33⁄4 (3.75) 43⁄4 (4.75) 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 6.2 A product analysis shall be permitted to be made by the purchaser from material representing the heat The chemical composition thus determined shall meet the requirements specified in Table or shall be subject to rejection by the purchaser NOTE 1—1 in = 25.4 mm FIG Quarter Bends 6.3 Spectrometric or other instrumental methods and wet laboratory methods are acceptable for routine control determinations Any method employed shall give essentially the same results as reference methods listed in Test Methods E350 (For selected detailed methods of analysis, see Specification A518/ A518M, paragraph 6.4) Heat Treatment Size, in 1⁄ 2 D, in ID, in 3 ⁄4 ⁄2 3 ⁄4 1⁄ 2 7.1 All centrifugally cast high-silicon iron pipe shall be supplied in the as-cast condition All other pipe and fittings shall be supplied in the stress-relieved condition Stop Lug Depth (P), in OD, in 23⁄16 25⁄ 33⁄ 43⁄ 11⁄32 11⁄32 11⁄32 11⁄32 7.2 Stress relieving shall be performed as follows: 7.2.1 Hold the casting at 1650°F (870°C) minimum for h plus an additional hour per inch of section thickness for castings over in in thickness 7.2.2 Cool the castings to 400°F (205°C) maximum at a rate not to exceed 100°F (55°C)/15 7.2.3 From 400°F (205°C) to ambient, the castings shall be permitted to be cooled in still, ambient air NOTE 1—1 in = 25.4 mm FIG Sixth Bends Joints 8.1 Acid-proof joints for hub/plain-end pipe shall require the use of an acid-proof rope packing Size, in C, in D, in F, in R, in ID, in 11⁄2 4 3⁄ 2 53⁄32 511⁄16 2 3⁄ 1 ⁄2 OD, in 23⁄16 5⁄ 8.2 No-hub pipe and fittings shall require a special acid resistant mechanical joint (MJ) coupling One satisfactory coupling consists of an inner PTFE sleeve surrounded by neoprene The two-bolt coupling is made of 300 series stainless steel Stop Lug Depth (P), in 11⁄32 11⁄32 8.3 High-silicon iron pipe can be cut with either manual or hydraulic snap cutters Field cuts shall be permitted to be readily used with mechanical joint couplings to provide acceptable leak-proof joints NOTE 1—1 in = 25.4 mm FIG Return Bends Dimensions and Permissible Variations 9.1 Pipe: 9.1.1 Hub/plain-end pipe shall have a hub at one end and a plain end at the other and shall be cast in one piece (see Fig 35) 9.1.2 Individual length of hub/plain-end pipe shall be either or ft nominal laying lengths as shown in Fig 35 4.1.7 Supplemental requirements desired, if any Materials and Manufacture 5.1 The castings shall be produced by any established commercial practice applicable to high-silicon iron A861 − 04 (2013) Size, in D, in E, in ID, in OD, in Stop Lug Depth (P), in 1⁄ 7⁄ 3⁄ 1 ⁄2 23⁄16 11⁄32 NOTE 1—1 in = 25.4 mm FIG Double-Branch Quarter Bend Size, in D, in ID, in OD, in Stop Lug Depth (P), in 1⁄ 2 1⁄ 2 3⁄ 3 1⁄ 1⁄ 2 23⁄16 25⁄ 33⁄4 43⁄ 11⁄32 11⁄32 11⁄32 11⁄32 NOTE 1—1 in = 25.4 mm FIG Eight Bends Size, in D, in ID, in OD, in Stop Lug Depth (P), in 1⁄ 2 2 1⁄ 1⁄ 3⁄ 1⁄ 2 23⁄16 25⁄ 33⁄ 43⁄ 11⁄32 11⁄32 11⁄32 11⁄32 NOTE 1—1 in = 25.4 mm FIG Sixteenth Bends 9.1.3 Any deflections in the barrel of a single length of pipe shall not exceed 3⁄16 in 9.1.4 No-hub pipe shall be cast in a single piece and conform to nominal dimensions shown in Fig 9.1.5 No dimension of hub/plain-end pipe shall exceed the tolerances specified in Table A861 − 04 (2013) FIG Long-Sweep Quarter Bends Size, in D, in F, in G, in ⁄ 2 3 4 4 ⁄8 ⁄8 45⁄8 5 ⁄8 57⁄8 63⁄8 ⁄8 65⁄8 71⁄8 75⁄8 1⁄2 1⁄2 3⁄8 1⁄2 1⁄8 5⁄8 1⁄2 1⁄2 3⁄4 101⁄4 7⁄8 5⁄8 1⁄4 1⁄2 1⁄4 3⁄8 3⁄8 3⁄4 5⁄8 × 1⁄ × 11⁄2 ×2 × 11⁄2 ×2 ×3 × 11⁄2 ×2 ×3 ×4 12 OD, in Stop Lug Depth (P), in 23⁄16 × 23⁄16 25⁄8 × 23⁄16 25⁄8 × 25⁄8 33⁄4 × 23⁄16 33⁄4 × 25⁄8 33⁄4 × 33⁄4 43⁄4 × 23⁄16 43⁄4 × 25⁄8 43⁄4 × 33⁄4 43⁄4 × 43⁄4 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 ID, in 1 ⁄2 2× 2× 3× 3× 3× 4× 4× 4× 4× × 1⁄ 11⁄2 11⁄2 11⁄2 NOTE 1—1 in = 25.4 mm FIG Sanitary Y Branches duced and furnished in accordance with this specification Foundry inspection by the purchaser shall not interfere unnecessarily with the manufacturer’s operations 9.2 Fittings—All fittings shall conform to the nominal dimensions specified in applicable figures and be within the tolerances specified in Table for fittings listed in Figs through 34 or in Table for fittings listed in Figs 36 through 39 11 Rejection and Rehearing 11.1 Material that shows unacceptable discontinuities as determined by the acceptance standards specified in the order, subsequent to its acceptance at the manufacturer’s works, shall be rejected and the manufacturer shall be notified within 30 days unless otherwise agreed upon 10 Inspection 10.1 Inspection and Test by the Manufacturer—Pipe and fittings shall be inspected by the manufacturer prior to shipment Inspection by the manufacturer shall include all tests as specified herein All tests and inspection with the exception of product analysis shall be made at the place of manufacture unless otherwise agreed upon 12 Certification 12.1 Upon request of the purchaser, the manufacturer shall certify that his product conforms to the requirements of this specification The results of tests shall be furnished to the purchaser upon request as mutually agreed upon 10.2 Inspection and Test by the Purchaser—The manufacturer shall afford the purchaser’s inspector all reasonable facilities necessary to satisfy that the material is being pro5 A861 − 04 (2013) 1 ⁄2 2× 2× 3× 3× 3× 4× 4× 4× Size, D, F, G, ID, OD, in in in in in in × 1⁄ 11⁄2 11⁄2 3 4 ⁄8 ⁄8 45⁄8 5 ⁄8 57⁄8 63⁄8 65⁄8 71⁄8 75⁄8 ⁄2 ⁄2 ⁄8 ⁄2 ⁄8 ⁄8 ⁄2 ⁄4 101⁄4 ⁄8 ⁄8 1 ⁄4 1 ⁄2 ⁄4 ⁄8 ⁄4 ⁄8 1 ⁄2 2× 2× 3× 3× 3× 4× 4× 4× × 1⁄ 11⁄2 11⁄2 3 23⁄16 × 23⁄16 25⁄8 × 23⁄16 5⁄ × 5⁄ 33⁄4 × 23⁄16 3⁄ × 5⁄ 3⁄ × 3⁄ 4 3⁄ × 5⁄ 3⁄ × 3⁄ 4 3⁄ × 3⁄ Stop Lug Depth (P), in 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 NOTE 1—1 in = 25.4 mm FIG 10 Double-Branch Sanitary Y Size, in 1⁄ 2× 2× 3× 3× 3× 4× 4× 4× 4× × 1⁄2 11⁄2 11⁄2 11⁄2 D, E, in F, in G, in ID, in 3⁄ 4 3⁄ 5 61⁄4 45⁄16 73⁄8 3⁄ 3⁄ 57⁄8 1⁄ 61⁄4 1⁄ 63⁄8 71⁄4 1⁄ 1⁄ 5⁄ 1⁄ 1⁄ 8 1⁄ 5⁄ 3⁄ 8 3⁄ 101⁄4 7⁄8 5⁄8 7⁄8 5⁄8 1⁄2 1⁄4 3⁄8 3⁄8 3⁄4 5⁄8 1⁄ × 1 ⁄ 2 × 11⁄2 2×2 × 11⁄2 3×2 3×3 × 11⁄2 4×2 4× 4× in OD, in 23⁄16 × 23⁄16 25⁄8 × 23⁄16 25⁄8 × 25⁄8 33⁄4 × 23⁄16 33⁄4 × 25⁄8 33⁄4 × 33⁄4 43⁄4 × 23⁄16 43⁄4 × 25⁄8 43⁄4 × 33⁄4 43⁄4 × 43⁄4 Stop Lug Depth (P), in 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 NOTE 1—1 in = 25.4 mm FIG 11 Sanitary Combination Y and 1⁄8 Bend 13 Product Marking 14 Packaging 13.1 Each length of pipe and fitting shall be identified by the manufacturer’s name or identification mark Marking shall be as not to impair the usefulness of the part 14.1 Unless otherwise specified, the material shall be packaged in accordance with the supplier’s standard practice and acceptable to the carrier at the lowest rates Containers and packing shall comply with Uniform Classification Rules or National Motor Freight Classification Rules 13.2 Samples that represent rejected material shall be preserved for a minimum of weeks from the date of transmission of the rejection report In case of dissatisfaction with the results of the tests, the manufacturer shall be permitted to make claim for a rehearing within that time 15 Keywords 15.1 corrosion resistant; fittings; high-silicon iron; hubless; hub/plain-end; no-hub; plain-end A861 − 04 (2013) Size, in 1⁄ 2× 2× 3× 3× 3× 4× 4× 4× × 1⁄ 11⁄2 11⁄2 3 D, in E, F, in G, in 3⁄8 3⁄4 57⁄8 1⁄4 61⁄4 63⁄8 71⁄4 1⁄ 1⁄ 5⁄ 1⁄ 1⁄ 8 1⁄ 3⁄ 8 3⁄ 101⁄4 7⁄ 5⁄ 5⁄ 5⁄ 1⁄ 2 1⁄ 3⁄ 3⁄ 5⁄ in 3⁄ 4 3⁄ 1⁄ 61⁄4 73⁄8 ID, in 1⁄ 2× 2× 3× 3× 3× 4× 4× 4× OD, in × 1 ⁄2 11⁄2 11⁄2 3 23⁄16 × 23⁄16 25⁄8 × 23⁄16 25⁄8 × 25⁄8 33⁄4 × 23⁄16 33⁄4 × 25⁄8 33⁄4 × 33⁄4 43⁄4 × 25⁄8 43⁄4 × 33⁄4 43⁄4 × 43⁄4 Stop Lug Depth (P), in 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 NOTE 1—1 in = 25.4 mm FIG 12 Double-Branch Sanitary Combination Y and 1⁄8 Bend Size, in 1 ⁄2 2× 2× 2× 3× 3× 3× 4× 4× 4× 4× × 1 ⁄2 11⁄2 11⁄2 × 11⁄2 11⁄2 11⁄2 E, in F, in G, in 1⁄ 4 1⁄ 1⁄ 41⁄2 5 59⁄16 51⁄2 51⁄2 51⁄2 3⁄ 3⁄ 3⁄ 7⁄ 63⁄4 71⁄4 83⁄8 7⁄ 1⁄ 1⁄ 3⁄ 1⁄4 1⁄4 1⁄4 1⁄2 1⁄4 1⁄2 47⁄32 1⁄2 5 1⁄2 ID, in 1⁄ × 1⁄ 2 × 11⁄2 × 11⁄2 × 11⁄2 2×2 × 11⁄2 3×2 3× 4× 11⁄2 4×2 4×3 4×4 NOTE 1—1 in = 25.4 mm FIG 13 Sanitary T Branches OD, in Stop Lug Depth (P), in 23⁄16 × 23⁄16 25⁄8 × 23⁄16 25⁄8 × 23⁄16 × 23⁄16 5⁄ × 5⁄ 33⁄4 × 23⁄16 33⁄4 × 5⁄8 33⁄4 × 33⁄4 43⁄4 × 23⁄16 43⁄4 × 25⁄8 43⁄4 × 33⁄4 43⁄4 × 43⁄4 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 A861 − 04 (2013) Size, in E, in F, in G, in ID, in OD, in Stop Lug Depth (P), in × 1⁄ 11⁄2 11⁄2 3 4 1⁄ 4 1⁄ 41⁄2 5 51⁄2 51⁄2 51⁄2 3⁄ 3⁄ 7⁄ 3⁄ 71⁄4 83⁄8 1⁄ 1⁄ 3⁄ 1⁄ 4 1⁄ 4 1⁄ 1⁄ 4 1⁄ 1⁄ 5 1⁄ 1 ⁄2 × 1⁄ 2 × 11⁄2 2×2 ×11⁄2 3×2 3×3 4×2 4×3 4×4 23⁄16 × 23⁄16 25⁄8 × 23⁄16 25⁄8 × 25⁄8 33⁄4 × 23⁄16 33⁄4 × 25⁄8 33⁄4 × 33⁄4 43⁄8 × 25⁄8 43⁄4 × 33⁄4 43⁄8 × 43⁄8 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 11⁄32 1⁄ 2× 2× 3× 3× 3× 4× 4× 4× Size, in A, in B, in C, in D, in J, in R, in ID, in 11⁄2 3⁄4 4 1⁄2 5⁄ 115⁄16 25⁄16 3 ⁄2 6 ⁄4 ⁄2 101⁄2 4 1⁄2 1⁄2 13⁄ 2 1⁄ 1⁄ 2 OD, in 23⁄16 25⁄8 33⁄ 4 3⁄ Stop Lug Depth (P), in 11⁄32 11⁄32 11⁄32 11⁄32 NOTE 1—1 in = 25.4 mm FIG 16 Sanitary P Traps NOTE 1—1 in = 25.4 mm FIG 14 Double-Branch Sanitary T Size, in A, in B, in C, in D, in J, in R, in ID, in OD, Stop Lug in Depth (P), in 1⁄2 3⁄4 1⁄2 4 1⁄2 5⁄ 115⁄16 25⁄16 5 1⁄2 1⁄2 1⁄2 10 11 13 15 4 ⁄2 ⁄2 ⁄4 2 ⁄2 1 ⁄2 23⁄16 25⁄8 3⁄ 4 3⁄ Size, C, in in D, in E, in F, in G, in H, in ID, in OD, in Stop Lug Depth (P), in 3⁄4 3⁄4 4 ⁄2 615⁄16 3⁄ 57⁄16 3⁄4 13⁄32 3⁄ 121⁄2 12 1⁄ 2 23⁄16 5⁄8 11⁄32 11⁄32 1⁄ 2 11⁄32 11⁄32 11⁄32 11⁄32 NOTE 1—1 in = 25.4 mm FIG 17 Swivel Trap P-Style Short NOTE 1—1 in = 25.4 mm FIG 15 Sanitary Running Traps A861 − 04 (2013) Size, CA , in in D, in E, in F, in G, in HA , in ID, in OD, in Stop Lug Depth (P), in 1⁄ 615⁄16 57⁄16 13⁄32 121⁄2 1⁄ 23⁄16 11⁄32 123⁄4 A For shorter C or H dimension, snap-cut to desired length FIG 20 Centrifugal Drum Trap P Swivel Type NOTE 1—1 in = 25.4 mm FIG 18 Swivel Trap P-Style Long Size, in C, in F, in G, in H, in ID, in OD, in Stop Lug Depth (P), in 1⁄ 2 6 3⁄8 101⁄2 143⁄8 12 223⁄4 175⁄8 1 ⁄2 23⁄16 ⁄8 11⁄32 11⁄32 NOTE 1—1 in = 25.4 mm Size, in C, in D, in E, in F, in J, in ID, in OD, in Stop Lug Depth (P), in 1⁄ 1⁄ 2 4 ⁄4 53⁄32 1515⁄32 511⁄16 ⁄4 ⁄4 79⁄16 123⁄4 123⁄4 141⁄4 4 3⁄4 1⁄2 1⁄2 1⁄8 1⁄8 11⁄32 11⁄32 11⁄32 NOTE 1—1 in = 25.4 mm FIG 19 Swivel Type-S Style Long FIG 21 Centrifugal Drum Trap S Swivel Type A861 − 04 (2013) Size, in Size, in B, in E, in 27⁄16 33 ⁄ 37 ⁄ 3⁄ 411⁄16 57⁄16 F, in 1⁄ 2 G, in 7⁄ 8 3⁄ 3⁄ 37⁄16 43⁄16 411⁄16 A, in 23⁄16 221⁄32 3⁄ 4 3⁄ D, in 1⁄ 1⁄ 1⁄ 2 3⁄ E, in 15⁄16 15⁄16 3⁄ 17⁄16 F, in 39⁄16 39⁄16 7⁄ 43⁄16 NOTE 1—1 in = 25.4 mm FIG 25 Cleanout Plugs NOTE 1—1 in = 25.4 mm FIG 22 Combination Cleanout and Test Tees Size, in Size, in A, in 1⁄ 2 3⁄ 47⁄16 415⁄16 B, in 1⁄ 1⁄ 1⁄ 1⁄ 2× 2× 2× 3× 4× 7⁄ 33⁄8 43⁄16 53⁄16 NOTE 1—1 in = 25.4 mm FIG 23 Coupling × × × × 4 1⁄ 2 A, in 323⁄32 313⁄16 313⁄16 313⁄16 45⁄16 45⁄16 45⁄16 55⁄16 69⁄32 B, in 1⁄ 221⁄32 313⁄16 413⁄16 223⁄32 313⁄16 413⁄16 313⁄16 7⁄ E, in ⁄ 9⁄16 9⁄16 9⁄16 ⁄8 ⁄8 ⁄8 11⁄16 11⁄16 16 NOTE 1—1 in = 25.4 mm FIG 26 Adapter/Hub to No-Hub Size, in F, in ⁄ 2 ⁄2 21⁄2 21⁄2 12 NOTE 1—1 in = 25.4 mm FIG 24 Pipe Plugs 10 F, in 5⁄ 5⁄ 5⁄ 7⁄ 1⁄ 3⁄ 5 3⁄ 59⁄16 A861 − 04 (2013) Size, in A, in J, in 53 ⁄ 1⁄ NOTE 1—Flange dimensions are 150 lb ANSI standard NOTE 2—1 in = 25.4 mm FIG 32 Adapter—No-Hub and Split Flange Type AD-11 AD-12 Size, in 11 ⁄ 2 B, in ⁄4 223⁄32 C, in 1 ⁄2 1 ⁄2 NOTE 1—1 in = 25.4 mm FIG 33 MJ to Lead Adapter NOTE 1—1 in = 25.4 mm FIG 34 Floor Drains 12 D, in 125⁄32 29⁄32 A861 − 04 (2013) Size, in Size, in 10 12 15 A, in B, in C, in D, in E, in F, in 43⁄16 53⁄16 63⁄16 811⁄32 103⁄4 133⁄4 16 193⁄4 35⁄16 45⁄16 55⁄16 75⁄16 5⁄ 121⁄4 141⁄2 173⁄4 21⁄32 1⁄ 1⁄ 515⁄16 1⁄ 10 12 15 211⁄16 325⁄32 425⁄32 611⁄16 111⁄4 131⁄4 163⁄4 ⁄8 ⁄8 ⁄8 3 ⁄8 4 ⁄8 49⁄16 55⁄16 3⁄ 817⁄32 111⁄4 141⁄4 163⁄4 201⁄4 Size, in t, in Weight, lb Working Length, ft 0.31 0.31 0.31 0.40 0.40 0.62 0.62 0.75 7 7 7 5 ⁄ ⁄ 5⁄16 13⁄32 13⁄32 5⁄8 5⁄8 7⁄8 10 12 15 16 16 × 11⁄2 2×2 × 1 ⁄2 3×2 3×3 × 1 ⁄2 4×2 4×3 4×4 6×2 6×3 6×4 6×6 8×4 8×6 8×8 10 × 10 × 10 12 × Overall Length 7 7 7 5 ft ft ft ft ft ft ft ft 25⁄8 in 25⁄8 in 25⁄8 in in in 37⁄8 in in 41⁄8 in 2 3 4 × × × × × × × 1⁄ 2 3 11 12 17 19 20 221⁄2 26 A, in 1⁄ 9 10 10 11 B, in 7⁄ 21⁄2 21⁄2 3 B, in 1⁄ 31⁄2 4 4 1⁄ 41⁄2 41⁄2 41⁄2 51⁄2 51⁄2 51⁄2 51⁄2 1⁄ 5⁄ 65⁄8 5⁄ 73⁄4 83⁄4 FIG 37 Sanitary T Branches FIG 35 Hub and Plain End Pipe Weight, lb A, in 1⁄ 1⁄ 10 1⁄ 10 11 10 11 13 105⁄8 141⁄2 19 141⁄4 21 19 NOTE 1—1 in = 25.4 mm NOTE 1—1 in = 25.4 mm Size, in Weight, lb 11 12 16 18 20 18 19 26 28 31 33 35 50 62 65 113 130 180 187 C, in 5⁄ 613 ⁄16 1⁄ 7 1⁄ NOTE 1—1 in = 25.4 mm FIG 36 Straight Tees 13 C, in 3⁄ 3⁄ 71⁄2 3⁄ 7 1⁄ 7 1⁄ 101⁄2 131⁄2 101⁄2 141⁄2 131⁄2 A861 − 04 (2013) Size, in 2 3 4 4 6 6 8 8 10 10 10 10 12 12 12 12 12 15 × × × × × × × × × × × × × × × × × × × × × × × × × × × × 11⁄2 11⁄2 1 ⁄2 4 6 8 10 10 12 15 Weight, lb 11 12 16 17 21 17 21 26 30 28 35 45 60 60 63 65 79 117 160 165 170 180 173 196 200 275 288 455 A, in 5⁄ 85⁄8 101⁄2 91⁄8 101⁄2 12 101⁄2 121⁄4 143⁄4 167⁄8 121⁄8 131⁄2 161⁄2 191⁄2 131⁄2 165⁄8 193⁄4 221⁄2 181⁄4 181⁄4 233⁄8 27 251⁄2 321⁄8 B, in ⁄8 41⁄4 51⁄16 5 ⁄2 513⁄16 53⁄4 ⁄4 63⁄4 71⁄8 ⁄8 ⁄4 ⁄8 9 10 11 121⁄4 111⁄2 131⁄2 143⁄8 15 153⁄16 161⁄2 151⁄2 191⁄2 183⁄8 223⁄4 Size, in C, in 2 3 4 4 6 6 8 3⁄ 3⁄ 7⁄ 43⁄16 7⁄ 311⁄16 1⁄ 1⁄ 211⁄16 1⁄ 1⁄ 3⁄ 41⁄2 33⁄4 41⁄2 61⁄16 1⁄ 1⁄ 7⁄ 3⁄ 75⁄8 1⁄ 1⁄ 1⁄ 1⁄ × × × × × × × × × × × × × × × 11⁄2 11⁄2 1⁄ 2 4 6 Weight, lb A, in 14 15 19 20 28 21 23 26 33 31 46 52 65 71 86 85⁄8 85⁄8 101⁄2 91⁄8 101⁄2 12 101⁄2 12 143⁄4 131⁄2 161⁄2 B, in C, in 3⁄ 41⁄4 51⁄16 5 1⁄ 513⁄16 53⁄4 1⁄ 63⁄4 71⁄8 5⁄ 81⁄8 1⁄ 10 11 3⁄ 3⁄ 7⁄ 43⁄16 7⁄ 311⁄16 1⁄ 1⁄ 211⁄16 1⁄ 1⁄ 3⁄ 101⁄2 61⁄16 NOTE 1—1 in = 25.4 mm FIG 40 Double-Branch Sanitary Y NOTE 1—1 in = 25.4 mm FIG 38 Sanitary Y Branches Size, in 2 3 4 4 6 × × × × × × × × × × × × 1⁄ 2 11⁄2 11⁄2 4 Weight, lb 15 17 17 22 27 24 24 28 40 45 57 83 A, in 85 ⁄ 85 ⁄ 101⁄2 91 ⁄ 101⁄2 12 101⁄2 12 15 B and B, in ⁄4 101⁄2 101⁄4 111⁄2 13 113⁄4 121⁄2 14 151⁄2 16 171⁄2 201⁄2 C, in 3⁄ 3⁄ 7⁄ 43⁄16 7⁄ 311⁄16 41 ⁄ 1⁄ 31 ⁄ 1⁄ 3⁄ E, in 3⁄ 8 1⁄ 3⁄ 83⁄16 99⁄16 1⁄ 83⁄16 99⁄16 1013⁄16 99⁄16 1013⁄16 137⁄16 NOTE 1—1 in = 25.4 mm FIG 41 Double-Branch Sanitary Combination Y and 1⁄8 Bend (T-Y) FIG 39 Double-Branch Sanitary Tee 14 A861 − 04 (2013) Size, in Size, in Weight, lb B, in C, in 11 20 25 ⁄4 6 ⁄2 10 2 3 4 4 6 6 10 10 NOTE 1—1 in = 25.4 mm FIG 42 Short-Sweep Quarter Bends × × × × × × × × × × × × × × × Weight, lb 1⁄ 2 11⁄2 11⁄2 4 6 11 13 14 18 24 17 21 23 31 33 37 47 63 185 192 A, in 5⁄ 5⁄ 101⁄2 1⁄ 101⁄2 12 101⁄2 12 15 163⁄4 213⁄8 B, in C, in 5⁄ 51⁄4 1⁄ 53⁄4 1⁄ 7⁄ 61⁄4 73⁄4 71⁄4 83⁄4 101⁄4 121⁄2 151⁄8 E, in 3⁄ 3⁄ 7⁄ 43⁄16 7⁄ 311⁄16 1⁄ 1⁄ 211⁄16 1⁄ 1⁄ 3⁄ 47⁄16 1⁄ 3⁄8 1⁄4 3⁄8 83⁄16 99⁄16 1⁄8 83⁄16 99⁄16 103⁄16 83⁄16 99⁄16 1013⁄16 137⁄16 3⁄8 181⁄2 NOTE 1—1 in = 25.4 mm FIG 44 Sanitary Combination Y and 1⁄8 Bend (T-Y) Size, in Weight, lb 14 24 29 47 98 B, in 81⁄2 91⁄2 101⁄2 111⁄8 C, in 12 121⁄2 13 14 15 NOTE 1—1 in = 25.4 mm FIG 43 Long-Sweep Quarter Bends Size, in Weight, lb 10 12 16 20 36 54 116 195 B, in 31⁄2 41⁄ 1⁄ 1⁄ 8 5⁄ 103⁄8 NOTE 1—1 in = 25.4 mm FIG 45 Quarter Bends 15 C, in 7 ⁄2 10 12 14 A861 − 04 (2013) Size, in Size, in Weight, lb 8 11 15 27 71 B, in 1⁄4 1⁄2 23⁄16 33⁄8 41⁄8 2 3 4 C, in ⁄4 65⁄16 ⁄8 × × × × × × × × × Weight, lb 6 8 10 A, in 13 17 17 16 17 33 50 85 9 9 9 115⁄8 117⁄8 16 NOTE 1—1 in = 25.4 mm FIG 46 Sixth Bends NOTE 1—1 in = 25.4 mm FIG 49 Sanitary Increasers Size, in Weight, lb 10 12 13 16 25 46 95 132 B, in 1⁄ 115⁄16 23⁄16 29⁄16 311⁄16 41⁄4 C, in 5⁄ 57⁄16 511⁄16 61⁄16 813⁄16 ⁄4 95⁄8 34 Size, in Weight, lb 21⁄2 10 18 14 NOTE 1—1 in = 25.4 mm FIG 50 Hub Strainers NOTE 1—1 in = 25.4 mm FIG 47 Eighth Bends Size, in Size, in Weight, lb 10 11 21 44 80 B, in 1 ⁄8 13⁄16 15⁄16 11⁄2 21⁄16 × 11⁄2 3×2 × 1 ⁄2 4×2 4×3 6×2 6×3 6×4 8×4 8×6 10 × 10 × 12 × 12 × 12 × 10 15 × 15 × 12 C, in 5⁄ 411⁄16 413⁄16 1⁄ 67⁄8 NOTE 1—1 in = 25.4 mm FIG 48 Sixteenth Bends Weight, lb A, in 7 11 12 13 14 22 25 39 51 55 65 83 79 109 5 5 5 5 6 6 61⁄2 6 6 NOTE 1—1 in = 25.4 mm FIG 51 Sanitary Reducers 16 A861 − 04 (2013) Size, in Weight, lb A, in 10 1⁄ 12 18 40 82 1 1 2 Size, in Weight, lb A, in J, in 11 12 22 44 53⁄4 91⁄2 103⁄4 ⁄2 11 131⁄2 NOTE 1—1 in = 25.4 mm NOTE 1—1 in = 25.4 mm FIG 55 Adapter—Plain-End and Split Flange FIG 52 Double Hubs Size, in Weight, lb 12 10 17 56 NOTE 1—1 in = 25.4 mm FIG 53 Pipe Plugs Size, in Weight, lb 10 31⁄2 61⁄2 11 14 26 39 NOTE 1—1 in = 25.4 mm FIG 54 Cleanout Plugs 17 A861 − 04 (2013) Size, in Weight, lb A, in J, in 12 16 36 21⁄2 1⁄ 23⁄4 3 1⁄ 1⁄ 11 131⁄2 NOTE 1—1 in = 25.4 mm FIG 56 Adapter—Hub and Split Flange Size, in Weight, lb 12 22 29 A, in 21⁄2 27⁄8 39⁄16 B, in C, i n 10 11 313⁄16 57⁄16 D, in ⁄8 45⁄8 5 ⁄8 E, in 31⁄16 1⁄4 1⁄2 F, in 7⁄ 313⁄16 413⁄16 NOTE 1—1 in = 25.4 mm FIG 57 Combination Cleanout and Test Tees Plate No Size, in Weight, lb 5045 5070 5095 5144 11 17 21 37 A, in 73⁄4 83⁄8 91⁄8 91⁄8 NOTE 1—1 in = 25.4 mm FIG 58 Insertable Joints 18 B, in ⁄2 ⁄8 7 ⁄8 7 ⁄8 A861 − 04 (2013) Size, in NOTE 1—1 in = 25.4 mm FIG 59 Backwater Valves Size, in Without Vent Weight, lb Hub Vent Weight, lb A, in B, in C, in D, in E, in G, in H, in Vent, in 12 25 37 68 16 32 45 80 11 121⁄2 14 17 1⁄4 1⁄2 1⁄2 61⁄4 ⁄4 1⁄ 1⁄ 1⁄ 1⁄ 2 ⁄4 3 ⁄4 313⁄16 41⁄2 53⁄16 61⁄2 5⁄8 25⁄16 315⁄16 4 Vent, in NOTE 1—Depth of seal on all traps shall be 21⁄2 in NOTE 2—1 in = 25.4 mm FIG 60 Sanitary P Traps Size, in Without Vent, Weight, lb Hub Vent, Weight, lb A, in B, in C, in D, in E, in F, in G, in H, in 16 24 33 82 18 29 39 89 91⁄4 101⁄2 111⁄4 14 1⁄4 1⁄2 1⁄2 10 12 16 ⁄2 ⁄2 ⁄2 ⁄2 3 ⁄4 ⁄4 ⁄4 ⁄4 ⁄4 313⁄16 ⁄2 53⁄16 61⁄2 5⁄ 25⁄16 315⁄16 NOTE 1—Depth of seal on all traps shall be 21⁄2 in NOTE 2—1 in = 25.4 mm FIG 61 Sanitary S Traps 19 4 A861 − 04 (2013) Size, in Without Vent, Weight, lb Single Hub Vent, Weight, lb Double Hub Vent, Weight, lb A, in B, in D, in E, in F, in G, in H, in 10 14 29 41 78 162 330 17 36 49 87 165 334 22 42 57 168 208 346 131⁄2 151⁄2 171⁄2 211⁄2 267⁄8 317⁄8 ⁄2 3 ⁄2 ⁄2 ⁄2 ⁄8 ⁄2 ⁄2 ⁄2 ⁄2 11 13 ⁄2 ⁄4 ⁄2 ⁄4 37 ⁄8 ⁄8 ⁄4 ⁄4 ⁄4 ⁄4 12 16 85⁄16 10 1111⁄16 15 187⁄16 221⁄4 5⁄ 25⁄16 315⁄16 1⁄ 611⁄16 NOTE 1—Single hub vent is located on the inlet side Depth of seal on and 10-in traps is in All others 21⁄2 in NOTE 2—1 in = 25.4 mm FIG 62 Sanitary Running Traps Plate No Outlet Size, in 2, 2, 2, 2, 2, 2, 2, 2, 3, 3, 3, 3, 3, 3, 3, 3, 4 4 4 4 and and and and and and and and Weight, lb 6 6 6 6 NOTE 1—1 in = 25.4 mm FIG 63 Outside Caulk 20 45 45 53 53 41 42 48 49 Vent, in 4 6

Ngày đăng: 03/04/2023, 14:41

TÀI LIỆU CÙNG NGƯỜI DÙNG

  • Đang cập nhật ...

TÀI LIỆU LIÊN QUAN