NIST NCSTAR 1-3D
Federal Building and Fire Safety Investigation of the
World Trade Center Disaster
Mechanical PropertiesofStructural
Steels
William E. Luecke
J. David McColskey
Christopher N. McCowan
Stephen W. Banovic
Richard J. Fields
Timothy Foecke
Thomas A. Siewert
Frank W. Gayle
NIST NCSTAR 1-3D
Federal Building and Fire Safety Investigation of the
World Trade Center Disaster
Mechanical PropertiesofStructural
Steels
William E. Luecke
J. David McColskey
Christopher N. McCowan
Stephen W. Banovic
Richard J. Fields*
Timothy Foecke
Thomas A. Siewert
Frank W. Gayle
Materials Science and Engineering Laboratory
National Institute of Standards and Technology
*Retired
September 2005
U.S. Department of Commerce
Carlos M. Gutierrez, Secretary
Technology Administration
Michelle O’Neill, Acting Under Secretary for Technology
National Institute of Standards and Technology
William Jeffrey, Director
Disclaimer No. 1
Certain commercial entities, equipment, products, or materials are identified in this document in order to describe a
procedure or concept adequately or to trace the history of the procedures and practices used. Such identification is
not intended to imply recommendation, endorsement, or implication that the entities, products, materials, or
equipment are necessarily the best available for the purpose. Nor does such identification imply a finding of fault or
negligence by the National Institute of Standards and Technology.
Disclaimer No. 2
The policy of NIST is to use the International System of Units (metric units) in all publications. In this document,
however, units are presented in metric units or the inch-pound system, whichever is prevalent in the discipline.
Disclaimer No. 3
Pursuant to section 7 of the National Construction Safety Team Act, the NIST Director has determined that certain
evidence received by NIST in the course of this Investigation is “voluntarily provided safety-related information” that is
“not directly related to the building failure being investigated” and that “disclosure of that information would inhibit the
voluntary provision of that type of information” (15 USC 7306c).
In addition, a substantial portion of the evidence collected by NIST in the course of the Investigation has been
provided to NIST under nondisclosure agreements.
Disclaimer No. 4
NIST takes no position as to whether the design or construction of a WTC building was compliant with any code
since, due to the destruction of the WTC buildings, NIST could not verify the actual (or as-built) construction, the
properties and condition of the materials used, or changes to the original construction made over the life of the
buildings. In addition, NIST could not verify the interpretations of codes used by applicable authorities in determining
compliance when implementing building codes. Where an Investigation report states whether a system was
designed or installed as required by a code provision, NIST has documentary or anecdotal evidence indicating
whether the requirement was met, or NIST has independently conducted tests or analyses indicating whether the
requirement was met.
Use in Legal Proceedings
No part of any report resulting from a NIST investigation into a structural failure or from an investigation under the
National Construction Safety Team Act may be used in any suit or action for damages arising out of any matter
mentioned in such report (15 USC 281a; as amended by P.L. 107-231).
National Institute of Standards and Technology National Construction Safety Team Act Report 1-3D
Natl. Inst. Stand. Technol. Natl. Constr. Sfty. Tm. Act Rpt. 1-3D, 322 pages (September 2005)
CODEN: NSPUE2
U.S. GOVERNMENT PRINTING OFFICE
WASHINGTON: 2005
_________________________________________
For sale by the Superintendent of Documents, U.S. Government Printing Office
Internet: bookstore.gpo.gov — Phone: (202) 512-1800 — Fax: (202) 512-2250
Mail: Stop SSOP, Washington, DC 20402-0001
NIST NCSTAR 1-3D, WTC Investigation
iii
ABSTRACT
This report provides five types ofmechanicalproperties for steels from the World Trade Center (WTC):
elastic, room-temperature tensile, room-temperature high strain rate, impact, and elevated-temperature
tensile. Specimens of 29 different steels representing the 12 identified strength levels in the building as
built were characterized. Elastic properties include modulus, E, and Poisson’s ratio, ν, for temperatures up
to 900 °C. The expression for E(T) for T < 723 °C is based on measurements of WTC perimeter column
steels. Behavior for T > 723 °C is estimated from literature data. Room temperature tensile properties
include yield and tensile strength and total elongation for samples of all grades of steel used in the towers.
The report provides model stress-strain curves for each type of steel, estimated from the measured stress-
strain curves, surviving mill test reports, and historically expected values. With a few exceptions, the
recovered steels, bolts, and welds met the specifications they were supplied to. In a few cases, the
measured yield strengths of recovered steels were slightly lower than specified, probably because of a
combination ofmechanical damage, natural variability, and differences in testing methodology. High-
strain-rate properties for selected perimeter and core column steels include yield and tensile strength, total
elongation and strain rate sensitivity for rates up to 400 s
-1
. Measured properties were consistent with
literature reports on other structural steels. Impact properties were evaluated with Charpy testing.
Properties for perimeter and core column steels were consistent with other structuralsteelsof the era. The
impact toughness at room temperature of nearly all WTC steels tested exceeded 15 ft·lbf at room
temperature. Elevated-temperature stress-strain curves were collected for selected perimeter and core
column and truss steels. The report presents a methodology for estimating high-temperature stress-strain
curves for the steels not characterized based on room-temperature behavior and behavior of other
structural steels from the literature. The measured elevated-temperature stress-strain behavior of WTC
steels is consistent with other structuralsteels from that era. For the truss steels, the report presents a
complete constitutive law for creep deformation based on experimental measurements. For the steels not
characterized, the report presents a methodology for estimating the creep deformation law.
Keywords: Creep, high strain rate, high temperature, impact, modulus, tensile strength, yield strength,
World Trade Center.
Abstract
iv
NIST NCSTAR 1-3D, WTC Investigation
This page intentionally left blank.
NIST NCSTAR 1-3D, WTC Investigation
v
TABLE OF CONTENTS
Abstract iii
List of Figures ix
List of Tables xv
List of Acronyms and Abbreviations xvii
Preface xix
Acknowledgments xxix
Executive Summary xxxi
Chapter 1
Introduction 1
1.1
Overview of Report 1
1.1.1
Elastic Properties (Chapter 2) 1
1.1.2
Room Temperature Tensile Properties (Chapter 3) 1
1.1.3
High-Strain-Rate Properties (Chapter 4) 3
1.1.4
Impact Properties (Chapter 5) 3
1.1.5
Elevated-Temperature Properties (Chapter 6) 3
1.2
Description of the Major Building Components 4
1.2.1
Perimeter Columns 4
1.2.2
Core Columns 6
1.2.3
Flooring System 6
1.3
Specimen Nomenclature 7
1.4
Symbols and Abbreviations 8
Chapter 2
Elastic Properties 11
2.1
Introduction 11
2.2
Experimental Procedure 11
2.3
Elastic Properties (E, ν, G) for 0<T<723 °C 11
2.4
Elastic Properties (E, ν, G) for T>910 °C 13
2.5
Elastic Properties (E, ν, G) for 723 °C<T<910 °C 13
2.6
Uncertainties 14
2.7
References 14
Table of Contents
vi
NIST NCSTAR 1-3D, WTC Investigation
Chapter 3
Room-Temperature Tensile Properties 19
3.1
Introduction 19
3.2
Test Procedures 19
3.2.1
Steel 19
3.2.2
Bolts 20
3.2.3
Welds 26
3.3
Results 28
3.3.1
Steel 28
3.3.2
Bolts 28
3.3.3
Welds 28
3.4
Comparison with Engineering Specifications 33
3.4.1
Steel 33
3.4.2
Bolts 60
3.4.3
Welds 60
3.5
Recommended Values 63
3.5.1
Steel 63
3.5.2
Bolts 67
3.5.3
Welds 74
3.6
Summary 75
3.7
References 75
3.7.1
References Available from Publicly Available Sources 75
3.7.2
References Available from Nonpublic Sources 76
Chapter 4
High-Strain-Rate Properties 79
4.1
Introduction 79
4.2
Test Procedures 79
4.2.1
High Strain-Rate Tension Tests 79
4.2.2
Analysis of High-Strain-Rate Tension Test Data 81
4.2.3
Kolsky Bar Tests 82
4.2.4
Quasi-Static Compression Tests 84
4.3
Results 84
4.3.1
High Strain-Rate Tension Tests 84
4.3.2
High Strain-Rate Kolsky Bar Tests 86
4.3.3
Quasi-Static Compression Tests 88
Table of Contents
NIST NCSTAR 1-3D, WTC Investigation
vii
4.4
Discussion 90
4.4.1
Calculation of Strain-Rate Sensitivity for Tension Tests 91
4.4.2
Calculation of Strain-Rate Sensitivity for Kolsky Tests 92
4.5
High-Strain-Rate Data Provided to the Investigation 94
4.6
Comparison with Literature Data 95
4.7
Summary 97
4.8
References 99
Chapter 5
Impact Properties 103
5.1
Introduction 103
5.2
Procedures 103
5.3
Results 105
5.3.1
Perimeter Columns 105
5.3.2
HAZ Materials from Perimeter Columns 106
5.3.3
Core Columns 106
5.3.4
Trusses 107
5.3.5
Truss Seats 107
5.3.6
Bolts 107
5.4
Discussion 107
5.4.1
Perimeter Columns 107
5.4.2
HAZ Materials from Perimeter Columns 109
5.4.3
Core Columns 109
5.4.4
Trusses 109
5.4.5
Truss Seats 110
5.4.6
Expected Values of Impact Toughness 110
5.5
Summary 111
5.6
References 111
Chapter 6
Elevated Temperature Properties 129
6.1
Introduction 129
6.2
Test procedures 129
6.2.1
Tensile Tests 129
6.2.2
Creep Tests 130
6.3
Results 130
Table of Contents
viii
NIST NCSTAR 1-3D, WTC Investigation
6.3.1
Tensile Tests 130
6.3.2
Creep Tests 130
6.4
Recommended values for steels 134
6.4.1
A Universal Curve for Elevated-Temperature Tensile Properties 134
6.4.2
Analysis of Tensile Data 136
6.4.3
Estimating Elevated-Temperature Stress-Strain Curves 137
6.4.4
Analysis of Creep Data 149
6.4.5
Recommended Values for Bolts 155
6.5
Summary 157
6.6
References 158
Chapter 7
Summary and Findings 161
7.1
Summary 161
7.2
Findings 162
Appendix A
Data Tables and Supplemental Figures 163
Appendix B
Effects of Deformation of Wide-Flange Core Columns on Measured Yield Strength 253
Appendix C
Provisional Analysis of High-Rate Data 263
Appendix D
Deformation ofSteels Used in WTC 7 273
Appendix E
Specimen Geometry Effects on High-Rate Tensile Properties 279
[...]... Investigation of the World Trade Center Disaster: Mechanical Propertiesof Structural Steels NIST NCSTAR 1-3D National Institute of Standards and Technology Gaithersburg, MD, September Banovic, S W., C N McCowan, and W E Luecke 2005 Federal Building and Fire Safety Investigation of the World Trade Center Disaster: Physical PropertiesofStructuralSteels NIST NCSTAR 1-3E National Institute of Standards... strengths of the Fy = 36 ksi wide-flange core columns are lower than expected from historical measurements of other structuralsteels The strain rate sensitivities of the yield and tensile strengths of perimeter and core columns are similar to other structuralsteels from the WTC construction era The impact propertiesof the steels, evaluated by Charpy testing, are similar to structuralsteels from... in characterizing the mechanicalpropertiesof the structural steels, bolts and welds recovered from the World Trade Center (WTC) site The first was to compare the measured propertiesof the steels with the requirements of the specifications that they were purchased under The second was to determine whether their properties were consistent with the properties and quality of other structural steel from... 32 Table 3–5 Summary ofmechanicalproperties and chemical compositions for steels from low-strength perimeter columns 40 Table 3–6 Summary ofmechanicalproperties and chemical compositions for steels from highstrength perimeter columns 43 Table 3–7 Summary ofmechanical properties, chemical compositions, and relevant ASTM and Yawata specifications for steels from high-strength... columns 45 Table 3–8 Summary ofmechanicalproperties and chemical compositions for steels from core column wide-flange shapes 49 Table 3–9 Summary ofmechanicalproperties and chemical compositions for steels from core box columns 51 Table 3–10 Common truss component dimensions and standards 57 Table 3–11 Summary ofmechanicalproperties and chemical compositions,... tests of core column steels 50 Figure 3–20 Yield behavior in tests of webs of four wide-flange core columns specified as Fy = 36 ksi 52 Figure 3–21 Section of C-88c that is the source of the specimens 56 Figure 3–22 Ratio of measured yield strength to specified minimum yield strength for all longitudinal tests of truss steels 59 Figure 3–23 Ratio of measured... ductile-to-brittle transition temperatures of the perimeter and core column steels are at or below room temperature The behavior of the yield and tensile strengths of WTC steels with temperature is similar to that of other structuralsteels from the WTC construction era xxxii NIST NCSTAR 1-3D, WTC Investigation Chapter 1 INTRODUCTION 1.1 OVERVIEW OF REPORT National Institute of Standards and Technology (NIST)... mechanical propertiesof the steels, bolts and welds were consistent with both the specifications that they were delivered to, and the expected propertiesofstructuralsteels from the construction era The experimentally determined mechanical property data can be divided into five groups: Elastic properties as a function of temperature were determined from recovered perimeter column steels Room temperature... results of investigations into the mechanicalpropertiesof the WTC steels Chapter 2 covers the temperature dependence of the elastic properties Chapter 3 covers the room-temperature, quasi-static stress-strain behavior Chapter 4 details investigations into the propertiesof the steel at high strain-rate, which are relevant for modeling the airplane impact Chapter 5 summarizes the results of Charpy... Values of the parameters of Eqs 6–5 and 6–6 for steels with Fy = 36 ksi 141 Table 6–6 Property data for the A 242 Laclede truss steel tested as part of the Investigation 142 Table 6–7 Individual Ki and ni used for steels with Fy > 36 ksi 142 Table 6–8 Values of the parameters of Eqs 6–5 and 6–6 for steels with Fy > 36 ksi 144 Table 6–9 Scaling parameters (Eq 6–4) for all WTC steels . Summary of mechanical properties and chemical compositions for steels from low-strength perimeter columns 40 Table 3–6. Summary of mechanical properties and chemical compositions for steels. Summary of mechanical properties and chemical compositions, and specifications for truss steels tested. 58 Table 3–12. Summary of mechanical properties, chemical compositions for truss seat steels. Summary of mechanical properties, chemical compositions, and relevant ASTM and Yawata specifications for steels from high-strength perimeter columns. 45 Table 3–8. Summary of mechanical properties