... characteristics: CABLE DESIGN - 2 96 fibres. - Operating wavelength at 1310nm and 1550nm. - Non-metallic central member. - Loose buffer tubes (dual layer design) SZ stranded. - Interstices and ... and buffer fully filled. - Dielectric strength member. - Inner PE sheath. - Corrugated steel tape for superior rodent protection. - Outer PE jacket. - Suita...

Ngày tải lên: 16/01/2014, 20:21

6 314 0
Tài liệu Datasheet - FO - Cable - Fibre Distribution Cables docx

Tài liệu Datasheet - FO - Cable - Fibre Distribution Cables docx

... Resistance: EIA-FOTP-41A 400 N/cm 400 N/cm 400 N/cm 400 N/cm 400 N/cm Impact Resistance: EIA-FOTP-25B 50 Impacts 100 Impacts 50 Impacts 500 Impacts 500 Impacts Flexing: EIA-FOTP-104A 1000 Cycles ... Passes @ 0°C and 70°C Cable Twist Test: EIA-FOTP-85A — — — 1000 Cycles 1000 Cycles Operating Temperature: -2 0°C to +70°C -2 0°C to +70°C 0°C to +70°C -2 0°C to +70°C (OFNR) -2 0°C t...

Ngày tải lên: 11/12/2013, 13:15

2 337 0
Tài liệu Datasheet - FO - Cable 10Gbit MM - N004CTSLZH050U docx

Tài liệu Datasheet - FO - Cable 10Gbit MM - N004CTSLZH050U docx

... marking 6.2 Cable Re-marking The re-marking shall be indent-marked, preferably with yellow characters, on the outer cable sheath. Any cable that contains two sets of cable markings shall ... PERFORMANCE AND TESTS 5.1 Temperature Range For the cables covered by this specification, the following temperature ranges apply: Operation : -2 0°C to +60°C Installation...

Ngày tải lên: 20/12/2013, 21:16

7 381 0
Tài liệu Datasheet - FO - Cable 10Gbit MM - N006CTSLZH050U doc

Tài liệu Datasheet - FO - Cable 10Gbit MM - N006CTSLZH050U doc

... PERFORMANCE AND TESTS 5.1 Temperature Range For the cables covered by this specification, the following temperature ranges apply: Operation : -2 0°C to +60°C Installation : -5 °C ... to +50°C Storage/Shipping : -2 5°C to +70°C 5.2 Mechanical and Environmental Performance of the Cable The mechanical and environmental performance of the cable shall be in acc...

Ngày tải lên: 20/12/2013, 21:16

7 269 0
Tài liệu Datasheet - FO - Cable - Highlight loose_tube_SM&MM docx

Tài liệu Datasheet - FO - Cable - Highlight loose_tube_SM&MM docx

... HIGHLIGHT ® Outdoor Loose Tube Multimode & Singlemode Fibre Cable

Ngày tải lên: 16/01/2014, 20:21

2 241 0
Tài liệu Datasheet - FO - Cable - LTS ARM JF Single Armor LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLELSZH jacket docx

Tài liệu Datasheet - FO - Cable - LTS ARM JF Single Armor LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLELSZH jacket docx

... KRSI-JF-510C-GSP Page 1 of 8 TECHNICAL SPECIFICATION LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLE KRSI-JF-510C-GSP Page 2 of 8 1. SCOPE 1.1 ... breakage KRSI-JF-510C-GSP Page 6 of 8 Table 5. The Mechanical and Environmental Performance of the Cable (continued) ITEMS TEST METHOD AND ACCEPTANCE CRITERIA Cable Twist Test # Test method: TIA/EIA-45 5-8 5A .....

Ngày tải lên: 21/12/2013, 19:15

8 415 0
Tài liệu Datasheet - FO - Cable - LTS ARM JF Single Armor docx

Tài liệu Datasheet - FO - Cable - LTS ARM JF Single Armor docx

... KRSI-JF-510C-GSP Page 1 of 8 TECHNICAL SPECIFICATION LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLE KRSI-JF-510C-GSP Page 2 of 8 1. SCOPE 1.1 ... breakage KRSI-JF-510C-GSP Page 6 of 8 Table 5. The Mechanical and Environmental Performance of the Cable (continued) ITEMS TEST METHOD AND ACCEPTANCE CRITERIA Cable Twist Test # Test method: TIA/EIA-45 5-8 5A .....

Ngày tải lên: 24/01/2014, 02:20

8 248 0
Tài liệu Datasheet - FO - Cable - LTS ARM JF Single Armor LSZH jacket docx

Tài liệu Datasheet - FO - Cable - LTS ARM JF Single Armor LSZH jacket docx

... KRSI-JF-510C-GSP Page 1 of 8 TECHNICAL SPECIFICATION LOOSE TUBE DESIGN, SINGLE JACKET/ SINGLE ARMOR, JELLY-FILLED, F/O CABLE KRSI-JF-510C-GSP Page 2 of 8 1. SCOPE 1.1 ... breakage KRSI-JF-510C-GSP Page 6 of 8 Table 5. The Mechanical and Environmental Performance of the Cable (continued) ITEMS TEST METHOD AND ACCEPTANCE CRITERIA Cable Twist Test # Test method: TIA/EIA-45 5-8 5A .....

Ngày tải lên: 24/01/2014, 02:20

8 191 0
Tài liệu Datasheet - FO - Cable - Non-Armor - MM - Technical Spec PE Jacket pdf

Tài liệu Datasheet - FO - Cable - Non-Armor - MM - Technical Spec PE Jacket pdf

... general requirements for fiber optic telecommunication cables used for inter-building backbone in duct installation and lashed aerial use. 1.2 Cable Description 1) Single Jacket/Non Armor Single and ... this section shall be performed at 1550nm for single mode fiber (SM) and at 1300nm for multi mode fiber (MM). Table 5. The Mechanical and Environmental Performance of the Cable ITEMS TES...

Ngày tải lên: 24/01/2014, 02:20

7 264 0
Tài liệu Datasheet - FO - Cable - In & Outdoor Loose Tube - HIGHLIGH doc

Tài liệu Datasheet - FO - Cable - In & Outdoor Loose Tube - HIGHLIGH doc

... HIGHLIGHT ® Outdoor Loose Tube Multimode & Singlemode Fibre Cable

Ngày tải lên: 09/12/2013, 15:15