Tài liệu KRONE - White paper - Switchboard Cable - 2003 pdf
... Solution Category 3 All-Weather CMR/CMX Cable Phone: 80 0-7 75 -KRONE 1 Web: www .KRONE. com No part of this document may be reproduced without permission. MK01 6-1 4 2003 KRONE, Inc. Switchboard Cable Shielded ... smaller cable assemblies, KRONE developed the 2 5-/ 5 0-/ 100-Pair Unshielded High Performance Switchboard (HPS) Cables. These cables, which are even smaller...
Ngày tải lên: 20/12/2013, 22:15
... regarding cable management within local area network com- munities, is how well cables and patch cords are managed at the rack or cable tray. Even though conductor management, as a part of overall cable management, ... pairs at all cable termination points. The engineers at KRONE recognized this new demand early and set out to create a system for managing the way individual conduct...
Ngày tải lên: 16/01/2014, 21:20
... problems. 1 www.kroneamericas.com 80 0-7 75 -KRONE This document may not be reproduced in whole or in part without written permission. © 2003 KRONE, Inc. White Paper ADSL Service Delivery January 21, 2003 A ... 2 www.kroneamericas.com 80 0-7 75 -KRONE This document may not be reproduced in whole or in part without written permission. © 2003 KRONE, Inc. Preface This whit...
Ngày tải lên: 10/12/2013, 02:15
Tài liệu KRONE - White paper - TrueNET - Do Standards Go Far Enough - 2003 pdf
... information on this issue can be obtained on the KRONE and Prestolite web sites at www .krone. com.au or www.prestolitewire.com. WHITE PAPER WHITE PAPER 1 of 4 pages Do the Standards go ... WHITE PAPER WHITE PAPER 3 of 4 pages loss therefore less signal degradation, significantly improving network performance. Even the match of the Network Interface Card...
Ngày tải lên: 16/01/2014, 21:20
Tài liệu KRONE - White paper - TrueNET - Improving Bit by Bit - 2003 docx
... Frequency 92.8 83.3 73.9 64.4 -0 .0 -4 .4 1.0 28.6 56.3 84.0 111.7 139.3 167.0 194.7 222.3 250.0 -8 .9 -1 3.3 No Deviation -1 7.8 dB Frequency (MHz) Attenuation vs. Frequency -2 2.2 -2 6.7 -3 1.1 -3 5.6 -4 0.0 Impedance* Impedance ... the channel. KRONE: 80 0-7 75 -KRONE www.kroneamericas.com www.truenet-system.com. No part of this document may be reproduced...
Ngày tải lên: 16/01/2014, 21:20
Tài liệu KRONE - White paper - TrueNET - Moisture Ingress - 2003 docx
... area of the cable. Although Attenuation, NEXT and Return Loss were effected slightly by the moist environment, the AirES cable tested passed Category 6 requirements. This white paper will focus ... competitor cable to separate the pairs (which makes the cable larger). This allows for more "free space" within the cable. Therefore, more fluid to be absorbed. The AirES c...
Ngày tải lên: 16/01/2014, 21:20
Tài liệu KRONE - White Paper - 10GBase-T Impossible is possible doc
... this works well within the cable, it doesn’t do much for cable- to -cable crosstalk (Alien Crosstalk). Alien Crosstalk is quite simply the amount of noise measured on a pair within a cable induced from ... 1. Example of a centre cable being impacted by the adjacent 6 cables in the bundle. Figure 2. Example of how cables with same twist lays impact one another. KRONE facts KRONE (Au...
Ngày tải lên: 10/12/2013, 02:15
Tài liệu KRONE - White Paper - A-Tick, the new ACA Standard Compliance pptx
... www .krone. com.au JNo.5548 - 1293 KRONE (N.Z.) Technique Limited PO Box 3 8-1 77 Wellington Mail Centre Wellington, New Zealand Tel: 0800 657 663 Fax: 0800 355 100 Email: sales @krone. co.nz Voltage With-stand Testing the ... the sheath of the cable with the company identifier, the product identifier, and the A- Tick, if practicable. KRONE s customer cabling and related customer e...
Ngày tải lên: 10/12/2013, 02:15
Tài liệu KRONE - White Paper - Catching up with Truenet pptx
... KRONE: 80 0-7 75 -KRONE www.kroneamericas.com www.truenet-system.com No part of this document may be reproduced without permission ©2001 KRONE, Inc. Catching Up With TrueNet TM of the KRONE ® ... 56 MB file used KRONE: 80 0-7 75 -KRONE www.kroneamericas.com www.truenet-system.com No part of this document may be reproduced without permission ©2001 KRONE, Inc. Testing the KRONE T...
Ngày tải lên: 10/12/2013, 02:15
Tài liệu KRONE - White paper - Limitation of RJ21 in Ethernet pptx
... capacity. KRONE recommends an impedance matched system using RJ-45 connectors instead. Figure 3: An RJ- 21 Assembly Figure 4: An RJ- 21 Assembly Figure 5: An RJ- 21 Assembly Figure 6: An RJ- 21 Assembly ... type of problem with a different RJ-21 assembly at another site. The effects of the mismatch on the frequency trace are the same. The inherent problem with the RJ-21 connector is that i...
Ngày tải lên: 10/12/2013, 02:15