power system stability and control by prabha kundur

power system stability and control chuong (1)

power system stability and control chuong (1)

... examples of disturbance data in books such as The BMI Handbook of Power Signatures, Second Edition, and the Dranetz Field Handbook for Power Quality Analysis ß 2006 by Taylor & Francis Group, ... be used in conjunction with power quality monitors to find a solution to the problem 33.4 Summary Most power quality problems can be solved with simple hand-tools and attention to detail S...

Ngày tải lên: 21/03/2014, 12:11

8 524 4
power system stability and control chuong (2)

power system stability and control chuong (2)

... Distribution System Modeling and Analysis William H Kersting 22 Power System Operation and Control George L Clark and Simon W Bowen 23 Hard to Find Information (on Distribution System Characteristics and ... transmission, distribution, and utilization of electric power and energy as well as the modeling, analysis, planning, design, monitoring, and control of electr...

Ngày tải lên: 21/03/2014, 12:11

14 499 6
power system stability and control chuong (3)

power system stability and control chuong (3)

... Oklahoma, and Texas), the winds are strongest in the spring (March and April) and weakest in the summer (July and August) Utilities here are summer peaking, and hence need the most power when ... 1-4 Land Rights The wind is a free, clean, and inexhaustible energy source It has served humankind well for many centuries by propelling ships and driving wind turbines to grind grain...

Ngày tải lên: 21/03/2014, 12:11

10 613 4
power system stability and control chuong (4)

power system stability and control chuong (4)

... a result, the compressor and the expander must operate at the same time and must have the same air mass flow rate In the case of a CAES plant, the compressor and the expander can be sized independently ... Group, LLC systems are quiet and non-polluting, and can be installed near load centers and existing suburban substations These have round-trip AC–AC efficiencies in the range of...

Ngày tải lên: 21/03/2014, 12:11

8 329 1
power system stability and control chuong (5)

power system stability and control chuong (5)

... of their total customer demand Some of these systems have been residential and commercial rooftop systems and other systems have been larger ground-mounted systems PV systems are generally classified ... Stand-alone PV systems are used when it is impractical to connect to the utility grid Common standalone systems include PV-powered fans, water pumping systems, portable highway signs, and...

Ngày tải lên: 21/03/2014, 12:11

8 482 1
power system stability and control chuong (6)

power system stability and control chuong (6)

... machine, for damping power system dynamic oscillations [see Power System Stability and Control, Kundur (1994) and Section of title Power System Stability and Control of this handbook.] Various auxiliary ... acceleration during system fault conditions [see Power System Stability and Control, Kundur (1994) and Section of title Power System Stability...

Ngày tải lên: 21/03/2014, 12:11

14 449 1
power system stability and control chuong (7)

power system stability and control chuong (7)

... at a fixed value, or is controlled to regulate power factor, motor current, or system stability In addition, the rotor also has shaft-mounted fans or blowers for cooling and heat removal from the ... these criteria, and the knowledge of the stator current and cooling system effectiveness, the manufacturer can project the motor component heating, and thus insulation life, and...

Ngày tải lên: 21/03/2014, 12:11

8 358 2
power system stability and control chuong (8)

power system stability and control chuong (8)

... DC Auxiliary Power Systems for Generating Stations Switchgear IEEE Standards Collection: Power and Energy-Switchgear, 1998 Edition Auxiliary Transformers IEEE Distribution, Power and Regulating ... DC system is supplied for circuit breaker and protective relaying The system voltage may collapse to close to zero during fault conditions and would not be capable of supplying re...

Ngày tải lên: 21/03/2014, 12:11

8 372 1
power system stability and control chuong (9)

power system stability and control chuong (9)

... automotive and transportation markets These experiments later expanded into markets associated with military and commercial aircraft and mobile systems Microturbines are typically defined as systems ... possibility of ‘‘islanding’’ a portion of the system Small: Between large and extremely small Extremely small: Generation less than 100 kVA Location on the system and individual...

Ngày tải lên: 21/03/2014, 12:11

10 393 1
power system stability and control chuong (10)

power system stability and control chuong (10)

... the system through a switch is the most frequently used voltage control method The capacitor reduces lagging -power- factor reactive power and improves the power factor This increases voltage and ... line, and consists of several thyristor-controlled capacitors in series or parallel, and may include thyristor-controlled inductors Medium- and low-voltage systems use several o...

Ngày tải lên: 21/03/2014, 12:11

14 399 1
power system stability and control chuong (11)

power system stability and control chuong (11)

... consideration as an International Standard References Carton, T and Peyrot, A., Computer Aided Structural and Geometric Design of Power Lines, IEEE Trans on Power Line Syst., 7(1), 1992 Dreyfuss, ... Valley, Electric Light and Power Magazine, 48(vii), 55–58, 1971 12 Pohlman, J and Lummis, J., Flexible Structures Offer Broken Wire Integrity at Low Cost, Electric Light and Powe...

Ngày tải lên: 21/03/2014, 12:11

12 339 1
power system stability and control chuong (12)

power system stability and control chuong (12)

... Lines and Substations Transmission line and substation insulation integrity is one of the most dominant factors in power system reliability We will describe typical transmission lines and substations ... energization and resonance, cause power frequency, or close-to -power frequency, and relatively long duration overvoltages The duration is from sec to several minutes The exp...

Ngày tải lên: 21/03/2014, 12:11

20 899 1
power system stability and control chuong (13)

power system stability and control chuong (13)

... realized and maximum safety of personnel is attained, properly designed and constructed tools and equipment are tantamount to a successful job Because the initial cost of these tools and equipment ... conductors being strung and pulling cables being used, or fully insulating equipment and operator, isolating equipment and personnel All equipment, conductors, anchors, and struc...

Ngày tải lên: 21/03/2014, 12:11

8 302 1
power system stability and control chuong (14)

power system stability and control chuong (14)

... Radial system and (B) looped system A radial system has the lowest initial cost, because a looped system requires the additional facilities to the second source Outage restoration on a radial system ... direct buried low-voltage power cables 12.4 Medium- and High-Voltage Power Cables Medium- and high-voltage power cables, in addition to being insulated, are shielded to c...

Ngày tải lên: 21/03/2014, 12:11

10 367 1
power system stability and control chuong (15)

power system stability and control chuong (15)

... Devices and Power Systems, John Wiley and Sons, Inc., New York, 1994 Glover, J.D and Sarma, M.S., Power System Analysis and Design, 3rd ed., Brooks=Cole, 2002 Stevenson, W.D Jr., Elements of Power System ... H., Power System Analysis, McGraw-Hill, Boston, MA, 1999 Gross, Ch.A., Power System Analysis, John Wiley and Sons, New York, 1979 Gungor, B.R., Power Systems...

Ngày tải lên: 21/03/2014, 12:11

28 531 1
w